Loading...
HomeMy WebLinkAboutR-40280100 I 1 w z O Q > O z W �rr V i 0 w a J n J O O U 0 w J C0 G 0 z CU G LO 0 a2 N lil Q Z w \-POINT 369 n �OINT 57 N GRAPHIC SCALE 0 50 100 200 1" = 100 FEET SITE MAP SCALE: 1 "=100' y� J , py tPA,Sgj��l,1 1306 SHEET INDEX SHEET NUMBER SHEET TITLE C1.0 COVER SHEET C1.1 STUDENT ACCESS C2.0 TESC & DEMOLITION PLAN C2.1 TESC & DEMOLITION PLAN C2.2 TESC & DEMOLITION PLAN C2.3 TESC & DEMOLITION PLAN C2.4 TESC NOTES & LEGEND C2.5 TESC NOTES & DETAILS C2.6 TESC NOTES & DETAILS C3.0 DRAINAGE PLAN C3.1 DRAINAGE PLAN C3.2 DRAINAGE PLAN C3.3 DRAINAGE PLAN C3.4 STORM DRAINAGE PROFILES C3.5 NOTES & DETAILS C3.6 NOTES & DETAILS C3.7 NOTES & DETAILS C3.8 NOTES & DETAILS C3.9 UNDERDRAIN DETAILS C4.0 GRADING, PAVING & HORIZONTAL CONTROL PLAN C4.1 GRADING, PAVING & HORIZONTAL CONTROL PLAN C4.2 GRADING, PAVING & HORIZONTAL CONTROL PLAN C4.3 PAVEMENT NOTES & DETAILS C4.4 DRAINAGE NOTES AND DETAILS L1.0 PLANTING PLAN L1.1 PLANTING PLAN L1.2 PLANTING PLAN L2.0 IRRIGATION DEMO L2.1 IRRIGATION PLAN L2.2 IRRIGATION PLAN L2.3 IRRIGATION PLAN L2.4 IRRIGATION DETAILS AS -BUILT 4v ■_ �.� EGISTEg� 1� I CERTIFY THAT THE INFORMATION SHOWN HEREON IONAL • WHICH WAS AS -BUILT BY AHBL, AND MAY INCLUDE 1/07/2019 0 LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING - - ALTERATAIN OF THIS DMENT SHALL INVXMTE THE FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY ONMSEAL AND SNHATURE.PUBUTATIONOF THIS DOMWW DOES NOT DEROGATE HIM RESERVED Know what'sbelOW. DIRECT SUPERVISION ON THIS DATE: 11/7/2019. 0011ERSHIP WM IN ff. THIS DOWN7 � TACOMA SEATTLE•SPOKANE•TRI-CITIESONLY WINE PRUW DENIM WINE 1 AND IS NOT TO BE USED FOR REPAIR R0100EL OR call before you dig. AHBL PROJECT NO.2180059 ADDTRON TO THAT PROkECT OR FOR ANY OTHER PRo M. 1200 6th Avenue, Suite 1620 Seattle, WA 98101 N0, 206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB TEMPORARY BENCHMARK TBM #1 AHBL #100 NAIL AND WASHER N:186930.6371 E:1306766.9234 ELEV:356.63 TBM #2 AHBL #101 NAIL AND WASHER N:187118.1267 E:1306675.4727 ELEV: 354.06 TBM #3 AHBL #102 NAIL AND WASHER N:186990.8120 E:1306488.4359 ELEV:351.91 TBM #4 AHBL #103 REBAR AND CAP N:187112.9252 E:1306223.8651 ELEV:343.64 UTILITIES / SERVICES WATER: CITY OF RENTON PHONE: (425)-430-7210 SANITARY SEWER: CITY OF RENTON PHONE: (425)-430-7332 STORMWATER: CITY OF RENTON PHONE: (425)-430-7332 POWER: PUGET SOUND ENERGY PHONE: 1-888-321-7779 GAS: PUGET SOUND ENERGY PHONE: 1-888-321-7779 PHONE: CENTURY LINK PHONE: 1-800-244-1111 ONE CALL: 1-800-424-5555 LEGAL DESCRIPTION TBM #5 AHBL #104 REBAR AND CAP N:186922.5518 E:1306223.5816 ELEV:338.86 POR S 1/2 OF NW 1/4 OF SW 1/4 OF SW 1/4 & SW 1/4 OF SW 1/4 OF SW 1/4 LESS RDS GENERAL NOTE 1. CONSTRUCTION SURVEY SHALL BE PROVIDED BY THE CONTRACTOR. TRENCH NOTE IF WORKERS ENTER ANY TRENCH OR OTHER EXCAVATION FOUR OR MORE FEET IN DEPTH THAT DOES NOT MEET THE OPEN PIT REQUIREMENTS OF WSDOT SECTION 2-09.3(3)B, IT SHALL BE SHORED AND CRIBBED. THE CONTRACTOR ALONE SHALL BE RESPONSIBLE FOR WORKER SAFETY AND AHBL ASSUMES NO RESPONSIBILITY. ALL TRENCH SAFETY SYSTEMS SHALL MEET THE REQUIREMENTS OF THE WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT, CHAPTER 49.17 RCW. AUTOCAD FILE AN AUTOCAD DRAWING FILE IS AVAILABLE TO ASSIST WITH SITE LAYOUT. PLEASE NOTE THAT ELECTRONIC FILES ARE PROVIDED FOR CONTRACTOR'S CONVENIENCE AND SHALL NOT REPLACE NOR BE USED TO SUBSTITUTE THE CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR PROJECT LAYOUT ACCORDING TO CONTRACT DOCUMENTS AND COST FOR ELECTRONIC AUTOCAD FILES. PHONE: (253) 383-2422 FAX: (253) 383-2572 CONTACT: WILLIAM FIERST, P.E. FILL SPECIFICATION FILL MATERIAL SHALL NOT CONTAIN PETROLEUM PRODUCTS, OR SUBSTANCES WHICH ARE HAZARDOUS, DANGEROUS, TOXIC, OR WHICH OTHERWISE VIOLATE ANY STATE, FEDERAL, OR LOCAL LAW, ORDINANCE, CODE, REGULATION, RULE, ORDER, OR STANDARD. EARTHWORK INFORMATION :1 LaKe arenas 00 Lake Washington Apartments WE x Gene Coulon Memorial Pinnacle 01) Lake Beach Park Washbgton Apartments W �pa�kpr THE LANDING N t S4 Fry's Electronics APPROX. 286 CUBIC YARDS CUT APPROX. 2208 CUBIC YARDS FILL NET: APPROX. 1,922 CUBIC YARD FILL NOTE: THE ABOVE QUANTITIES ARE ESTIMATES ONLY INTENDED FOR THE PERMITTING PROCESS AND ARE NOT TO BE USED BY THE CONTRACTOR FOR BIDDING PURPOSES. THE CONTRACTOR SHALL MAKE THEIR OWN EARTHWORK DETERMINATION. ONSITE SOILS SHALL BE RE -USED TO THE MAXIMUM EXTENT FEASIBLE. CONTRACTOR SHALL OBTAIN IMPORT MATERIALS AND DISPOSE OF EXPORT MATERIALS AT APPROVED LOCATIONS TO BE DETERMINED PRIOR TO THE START OF CONSTRUCTION ACTIVITIES. INSPECTION NOTIFICATION CITY OF RENTON DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT, DEVELOPMENT SERVICES 1055 SOUTH GRADY WAY RENTON, WA. 98057 PH: (425) 430-7200 PRECONSTRUCTION A1^TC1�+ 1. THE CONTRACTOR IS REQUIRED TO NOTIFY THE DEVELOPMENT SERVICES DIVISION, LAND USE INSPECTION SECTION (425) 430-7200, THREE DAYS PRIOR TO THE BEGINNING OF CONSTRUCTION FOR A PRECONSTRUCTION CONFERENCE AND SPECIFICALLY REQUEST INSPECTION BEFORE BEGINNING: A. INSTALLING SILTATION AND EROSION CONTROL MEASURES B. CLEARING AND GRUBBING C. EARTHWORK D. INSTALLATION OF ANY UNDERGROUND UTILITY E. BEFORE PLACING SUBBASE, BASE OR PAVING SURFACES F. INSTALLATION OF ANY FORMS OR PLACING ANY CONCRETE OWNER RENTON SCHOOL DISTRICT 7812 S 124TH ST SEATTLE, WA 98178 PH: (425) 204-4479 CONTACT: STEWART SHUSTERMAN BASIS OF BEARING VERTICAL DATUM NAD 83/91 CITY OF RENTON CONTROL NETWORK HOLDING POINT NUMBERS 57 AND 369. POINT 57 - 3" BRASS DISC IN CASE AT INTERSECTION OF NE 12TH STREET AND EDMONDS AVENUE NE. N=186452.8651 E=1306190.3942 POINT 369 - BRASS DISC IN CASE LYING IN CENTER OF EDMONDS AVENUE NE APPROXIMATELY 185 FEET NORTHERLY OF INTERSECTION WITH NE 20TH STREET. N=189092.0330 E=1306215.3062 NAVD 88 CITY OF RENTON CONTROL NETWORK HOLDING POINT NUMBERS 57 AND 369. POINT 57 - 3" BRASS DISC IN CASE AT INTERSECTION OF NE 12TH STREET AND EDMONDS AVENUE NE. ELEVATION=326.43' POINT 369 - BRASS DISC IN CASE LYING IN CENTER OF EDMONDS AVENUE NE APPROXIMATELY 185 FEET NORTHERLY OF INTERSECTION WITH NE 20TH STREET. ELEVATION = 332.57' CIVIL ENGINEER / LANDSCAPE ARCH / SURVEYOR AHBL, INC. 2215 NORTH 30TH STREET SUITE 300 TACOMA, WA 98403 PH. (253) 383-2422 FAX (253) 383-2572 CIVIL CONTACT: ADAM BRAUN, P.E. OR ANNE TURPIN, P.E. LANDSCAPE ARCH CONTACT: KRISTIN GLANDON, P.L.A. SURVEY CONTACT: DAVID FOLLANSBEE, P.L.S. CONSTRUCTION RECORD DRAWINGS SURVEYED: DESIGNED: STORM DRAINAGE REVISIONS AMT 09/20/2019 ACB DRAWN: AMT ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS AMT 01 28 2019 ACB CHECKED: BJS REVISION BY DATE APPR APPROVED: WJF SCALE: AS SHOWN ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 19M HORIZONTAL NAD 1983/1991 DATUM SITE NF J14d M LOCATION .f SE 104e ar CL z S• C1~ McKnight Middle a0 m toodwill Denton h s rt � z NE 131h PI � r°r e m � m Nf 171h st ME 121h st Tree • )011ar ] p�tk Ar yg -15 NF 11thpi 6t�- W'j x 11 a m t NE 1 lth St 9 t r�i , a z NE I h1h PI a a hif s et C r NE Tfllh P! NF. 1DIh St NE loth I n ° iw NE A 3 m INC 19th SI N!: 9111 PI NE 7th S! z ° m NF 'S ? w 4 kJr •r VICINITY MAP SCALE: 1" = 1,000' SITE INFORMATION SITE ADDRESS: 1200 EDMONDS AVENUE NE, RENTON, WA 98056 PARCEL NUMBER: 7227801860,0423059048 SECTION, TOWNSHIP, RANGE: SW 1/4, SECTION 4, TOWNSHIP 23 NORTH, RANGE 05 EAST, WILLAMETTE MERIDIAN PARCEL AREA: 20.39 ACRES N PROJECT AREA: 3.34 ACRES UTILITY NOTES 1. SURFACE UTILITY FACILITIES ARE SHOWN HEREON PER FIELD LOCATED VISIBLE EVIDENCE. THERE MAY BE UTILITIES THAT EXIST ON THIS SITE OTHER THAN THOSE GRAPHICALLY DEPICTED HEREON. 2. UNDERGROUND (BURIED) UTILITIES SHOWN HEREON ARE BASED ON COMBINATIONS OF VISIBLE SURFACE EVIDENCE, UTILITY LOCATOR MARKINGS AND RECORD DATA (SUCH AS AS -BUILT OR UTILITY DESIGN DRAWINGS). ALL UNDERGROUND UTILITIES SHOWN HEREON ARE APPROXIMATE AND, IN SOME CASES, ARE SHOWN AS STRAIGHT LINES BETWEEN FIELD LOCATED SURFACE UTILITY FACILITIES. UNDERGROUND UTILITIES MAY HAVE BENDS, CURVES OR CONNECTIONS WHICH ARE NOT SHOWN. 3. ALTHOUGH LOCATIONS OF UNDERGROUND UTILITIES BASED ON UTILITY LOCATOR MARKINGS AND RECORD DATA (SUCH AS AS -BUILT OR UTILITY DESIGN DRAWINGS) ARE DEEMED RELIABLE, AHBL, INC ASSUMES NO LIABILITY FOR THE ACCURACY OF SAID DATA C) Lo co T �� O 0 I rr z 4. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE APPROXIMATE ONLY AND HAVE NOT O BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND Q AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES THAT HAPPEN DUE TO THE CONTRACTOR'S FAILURE TO LOCATE EXACTLY AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. Q 5. CALL 1-800-424-5555 BEFORE ANY CONSTRUCTION. z w CITY OF 1;R] RENTON Planning/Building/Public Works Dept. 0 J W LL Q J R-402801 a 0 IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0 McKNIGHT MIDDLE SCHOOL FIELD IMPROVEMENTS RENTON SCHOOL DISTRICT COVER SHEET vJ Ljj 0 0 = DATE 1/15/2019 FIELDBOOK: PAGE _ z DRAWING NO:- C1.0 2 SHEET: OF. 1 32