Loading...
HomeMy WebLinkAboutR-40280800 N O 0 W I— Z O I— O Z W �fr V J 0 J W_ 1 a I..L J O O 2 U J 0 C� Z U 0 to ao C4 w Q z w DRIVEWAYS SHALL BE PAVED TO THE EDGE GROPD / OF R-O-W PRIOR TO INSTALLATION OF THE AVOID DAMAGING OF THE ROADWAY IT IS RECOMMENDED THAT THE R = 25' MIN. ENTRANCE BE CROWNED SO THAT RUNOFF DRAINS OFF THE PAD INSTALL DRIVEW1 IS A ROADSIDE DI PER CITY ROAD E 5�• 12" MIN. THICKNESS PROVIDE FULL WIDTH OF NOTES INGRESS/EGRESS AREA 1. CONDITION OF USE 1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE GRABTENSILE STREBNGTH(ASTM D4751) 1200 PSI MIN. GRAB TENSILE ELONGATION (ASTM D4632) 130%MAX. MULLEN BURSTSTRENGTH (ASTM D3786-80A) 1400 PSI MIN. AOS (ASTM D4751) 20-45 (U.S. STANDARD SIEVE SIZE) 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN ARES THAT WILL BOT BE USED FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY AT ANYTIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT. 2.2. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE. 2.3. WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SUBSTANTIALLY INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE. 3. MAINTENANCE STANDARDS 3.1- QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS. 3.2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE, OR THE INSTALLATION OF THE WHEEL WASH- IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASHED WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND. 3.3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS ATHREAT TO PUBLIC SAFETY. IF IT NECESSARY TO WASH THE STREETS, A SMALL SUMP MUST BE CONDUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND DISCHARGED APPROPRIATELY. 3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. 3.5- IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE INSTALLED TO CONTROL TRAFFIC. O~ Y O STD. PLAN - 215.10 PUBLIC WORKS STABILIZED DEPARTMENT CONSTRUCTION ENTRANCE MARCH 2O08 N CONSTRUCTION ENTRANCE (COR STD. PLAN 215.10) NOT TO SCALE BASE BID - DRAINAGE GRATE _ rTRIM GRATE FRAME e d p - SEDIMENTANDDEBRIS v OVERFLOW BYPASS r D P p BELOW INLET GRATE DEVICE FILTERED WATER e A A SECTION VIEW REC" DRAINAGE GRATE - ISOMETRIC VIEW NOTES 1. Size the Below Inlet Grate Device (BIGD)forthe storm watershucture itwill service. 2. The BIGD shall have a built-in high -flow relief system (overflow bypass). 3. The retrieval system must allow removal of tits BIGD without spilling the collected material. 4. Perform maintenance in accordance With Standard Specification 8-01.3(15). 1 Y�O PUBLIC WORKS DEPARTMENT =M (TYP.) CATCH BASIN FILTER STD. PLAN — 216.30 MARCH 2O08 CATCH BASIN FILTER (COR STD. PLAN 216.30) NOT TO SCALE JOINTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS. USE STAPLES, WIRE RINGS, OR FDI IIVAI FNT T ATTM.H FARRI(: Tr] P(VgT 6' MAX. u � POST SPACING MAY BE INCREASED TO F IF WIRE BACKING IS USED 2'S2" BY 14 G.. WIRE OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FA MINIMUM 411' TRENCH BACKFILL TRENCH WITH NATIVE SOIL 2W WOOD POSTS, STEEL FENCE / POSTS, REBAR, OR EQUIVALENT NOTES 1. CONDITION OF USE 1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. 1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MOST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. THE GEOTEXTILE USED MOST MET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MOST BE AVAILABLE ON SITE. ail: SIEVE SIZE(Q60-0.15KMF FOR SILT FILM ADS (ASTM D4751) 50-100SIEVE SIZE a.300.15 FOR OTHER FABRICS WATER PERMITRVITY ASTM D491 0.02 SECII MINIMUM 180 LBS' MIN. FOR EXTRA STRENGH FABRIC GRAB TENSILE STRENCHT(ASTM D4632) 100 LBS. MIN. FOR STANDARD STRENGHr FABRIC GRABTENSILE ELONGATION ASTM D4632 30%MAX. ULTRAVIOLATE RESISTANCE(ASTM D4355) 70%MIN. 2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. 2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1 V 2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4X4 TRENCH MAY NOT BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 3. MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIR IMMEDIATELY. 3.2. IF CONCENTRATED FLOES ARE EVIDENT UPHILL OD THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVED THE TRAP SEDIMENT. 3.4. SEDIMENT MOST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH. 3.5. IF THE FILTER FABRIC (GEOTE)CTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. PUBLIC WORKS + i DEPARTMENT SILT FENCE SILT FENCE (COR STD. PLAN 214.00) NOT TO SCALE 4' 4 BERM BERM TOP _OF_BERM =_35616 ?51 0 — — — — EMERGENCY OVERFLOW = 355.16 — — — — — — — — — 55 — EXISTING EXISTING \ �1 1 GROUND GROUND — BOTTOM OF POND 351.66 MIN. BASEBALL FIELD SEDIMENT TRAP -SECTION (COR STD. PLAN 211.00) NOT TO SCALE AS -BUILT /" EGISTEg� ��s10NAL I CERTIFY THAT THE INFORMATION SHOWN HEREON MLOCATIONS, WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE 1/07/2019 0 ELEVATIONS, DEPTHS, PIPE SIZES, AND AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING - - FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY ALTERATION OF THIS DMOIT SHALL INVM IMTE THE lSE&MSIWIURE.Pueuc70OF Knowwhatrs belOW. DIRECT SUPERVISION ON THIS DATE: 11/7/2019. THIS DOD11QlT DOES NOT DEROGATE FROM RESOM TACO MA SEATTLE SPOKANE TRI-CITIES 1 call before dig. AHBL PROJECT NO.2180059 AND IS NOT TO BE USED FOR REPAIR 1110100EL OR ADDITION TO THAT PROECT OR FOR ANY OM PRo M. 1200 6th Avenue, Suite 1620 Seattle, WA 98101 you N0. 206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB STD. PLAN — 214.00 MARCH 2O08 rl MIN 1'-;O�ERFLONTOEPTM T E�TylytlYtl)rlJF —� [II �iONSTRUCTEDAY F1W SEDIMENT. BTORAGE Y VDEPTN3147'=1,`--YMd WASH=PGRAVEL CRclift, SECTI6W HIM NOT& MAY' BE CONSTRUCTED BY' EXCVA]lON OR -B,Y' $�Qk_D_tN9,A BERM A� SE01ME--NT `1 "P 7T► 1 ` I I SEDIMENT TRAP (COR STD. PLAN 211.00) NOT TO SCALE FALTER FABRIC FENCING M. PLAN G "00- ��i�REIT �IrYEi 4' 4 BERM BERM ? �0 TOP OF BERM=_3500_0 ?�1 0 1 0�\ — — — — EMERGENCY OVERFLOW = 349.00 — — — — — — — — — 49 — 3 3 /�/ EXISTING EXISTING \ 1 GROUND GROUND— BOTTOM OF POND 345.50 MIN. SOCCER FIELD SEDIMENT TRAP -SECTION (COR STD. PLAN 211.00) NOT TO SCALE CONSTRUCTION RECORD DRAWINGS SURVEYED: SCALE NAD 1983/1991 DESIGNED: AS SHOWN HORIZONTAL STORM DRAINAGE REVISIONS AMT 09/20/2019 ACB DRAWN• AMT ONE INCH DATU M ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS AMT 01 28 2019 ACB CHECKED,,. AT FULL SCALE IF NOT ONE INCH REVISION BY DATE A P P R APPROVED: SCALE ACCORDINGLY WJF CITY OF RENTON Planning/Building/Public Works Dept. ALTERNATE BID NO O ^ 'N L J C) MO W T co 0 0 I .1 Z O Q O Z 0 w 0� Cn 0 w H Q J O IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0 McKNIGHT MIDDLE SCHOOL FIELD IMPROVEMENTS RENTON SCHOOL DISTRICT TESC NOTES & DETAILS U U) J 0 = DATE 1/15/2019 FIELDBOOK: PAGE _ Z DRAWING NO:— C2.5 SHEET: OF. g 32