Loading...
HomeMy WebLinkAboutR-402811W N O 0 W z O Q > O z w rr 0 LLJ LL J n J O O U J C0 G I- z U G O to N lil zz w P - 137, 11 LF O8 f\ � _ IJ P - 90, 87 LF D CB 05 O 2 P-138,93LF C3.4 ■ ",P - 91,104 LF D P - 92, 120 LF 11 D D pp- ■ P - 93, 137 LF D D ■ P - 94, 153 LF D D• P - 95, 142 LI ■ P - 96, 131 LF D P - 97, 120 LF D D ■ ■ P - 98, 108 LF D 7 TYP. P - 99, 98 LF L D P-101,74LFD \\ / 1`13 if),) co 1 17 0 LL J / LL 00 J � � � M JILL. U � co N ' � r � ^� r 2 C3.4 ■ ■ /r 0 Uj -Y_Y- BENCH: : ; \ ■ ■ ■ A'T ft ■ (0 � ■ G A A r\ ■ ■ ■ ■ T LL J r 11 oil D �g- D - / P - 128 203 LF ILL LL J co r i \ J N N r r r LL r 00 r i J r r r o r r r C r ` � I � 11' I. TYP. • WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY Know what's beIOW. DIRECT SUPERVISION ON THIS DATE: 11/7/2019. Call before you dig. AHBL PROJECT NO.2180059 P-129,70LF O �CB 07 O 9 / P - 133, 77 LF O8 0 0 1 PIN /07/2019 �r ■rr r r TA C O M A• SEATTLE • SPOKANE •TRI-CITIES 1200 6th Avenue, Suite 1620 Seattle, WA 98101 I NO. 206.267.2425 TEL 206.267.2429 FAX www.ahbl.com wEE Pipe Table PIPE NAME SIZE (in) UPPER INVERT ELEVATION SLOPE P - 90 4 352.57 2.84% P - 91 4 352.76 2.18% P - 92 4 352.92 1.43% P - 93 4 353.08 1.01 % P - 94 4 353.28 0.72% P - 95 4 353.47 0.78% P - 96 4 353.64 0.81 % P - 97 4 353.84 0.88% P - 98 4 354.05 1.00% P - 99 4 354.25 1.12% P - 100 4 354.42 1.26% P - 101 4 354.50 1.29% P - 102 4 354.51 1.15% P - 103 4 354.57 1.15% P - 104 4 354.64 1.17% P - 111 4 354.60 1.08% P - 112 4 354.57 1.16% P - 113 4 354.54 1.19% P - 114 4 354.51 1.23% P - 115 4 354.33 1.1 1 % STORM STRUCTURE TABLE STRUCTURE NAME STRUCTURE DETAILS CB 05 RIM =2- 48" TYPE 2 CB IE =349.95-(8" E) N 187170.87 IE =395 (8" SW) E 1306773.24 IE =349.95-(8" W) CB 06 RIM =354.17 54" TYPE 2 CB IE=346.99-(36" SW) N 187129.26 IE =347-95 (8" NE) E 1306689.88 RIM = 354.19 CB 07 IE =352.99 (8" SE) 48" TYPE 2 CB IE =352+7 (4" SE) N 187162.12 IE=352-1-(4" SW) E 1306842.53 IE =352.99 (8" S) IE =362.99 (8" W) CB 08 CB TYPE 1 RIM = 853.49- N 186925.91 IE=349.29-(8" SW) E 1306875.15 LEGEND: ■ STORM CATCH BASIN Q■ STORM MANHOLE ® DETENTION TANK ACCESS RISER GRADE BREAK D STORM LINE PERFORATED PIPE STORM LINE DETENTION TANK 1 2 C3.4 C3.4 XXX CONTOUR LINE PROPERTY/RIGHT-OF-WAY LINE FLOW DIRECTION n ADS N-12 S-P, 4" CAP N GRAPHIC SCALE 0 10 20 40 I=i mmllll - 1" = 20 FEET Pipe Table PIPE NAME SIZE (in) UPPER INVERT ELEVATION SLOPE P - 116 4 354.12 0.95% P - 117 4 353.90 0.84% P - 118 4 353.63 0.70% P - 119 4 353.50 0.69% P - 120 4 353.49 0.78% P - 121 4 353.09 0.59% P - 122 4 352.97 0.50% P - 123 4 352.98 0.50% P - 124 4 353.00 0.50% P - 125 4 353.01 0.50% P - 128 8 354.51 1.24% P - 129 8 352.00 2.94% P - 133 8 352.38 0.50% P - 137 8 350.08 1.22% P - 138 8 349.95 2.15% P - 139 36 345.00 0.00% P - 169 8 350.50 1.14% RIM = 354.21 IE = 349.89 (8" E) IE = 349.89 (8" SW) IE = 349.89 (8" W) RIM = 354.35 IE = 344.89 (36" SW) IE = 347.73 (8" NE) IE = 351.94 (8" SE) IE = 352.09 (4" SE) IE = 352.09 (4" SW) IE = 351.94 (8" S) IE = 351.94 (8" W) RIM = 353.20 IE = 350.85 (8" SW) CONSTRUCTION RECORD DRAWINGS SURVEYED: DESIGNED: STORM DRAINAGE REVISIONS AMT 09/20/2019 ACB DRAwN. AMT ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS AMT 01 28 2019 ACB CHECKED: Bis REVISION BY DATE APPR APPROVED: WJF SCALE: AS SHOWN ONE INCH AT FULL SCALE IF NOT ONE IN SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL NAD 1983/1991 DATU M � � L \\\\ \\\\\ \ CITY OF 1;R] RENTON NUF Planning/Building/Public Works Dept. KEYNOTES: OWITH TYPE 1 CATCH BASIN HERRINGBONE 1 2 O GRATE C3.5 C3.6 TYPE 1 CATCH BASIN 1 1 O WITH SOLID COVER C3.5 C3.6 O TYPE 2 CATCH BASIN 2 2 O3 WITH HERRINGBONE C3.5 C3.6 O GRATE O TYPE 2 CATCH BASIN WITH ROUND SOLID LID 2 3 C3.5 C3.6 10 FLOW CONTROL 1 O5 MANHOLE C3.8 11 COLLECTOR DRAIN 2 OCLEANOUT C3.9 4" PERFORATED 3 UNDERDRAIN, TYP. C3.9 8" COLLECTOR DRAIN 4 C3.9 CONNECTION TO COLLECTOR 1 DRAIN, TYP. C3.9 DETENTION TANK 4 ACCESS RISER, TYP. C3.8 CONVEYANCE PIPE O Lo O 00 � u NOTES: 1. SEE SHEETS C3.5 FOR GENERAL STORM DRAINAGE NOTES. 2. CONTRACTOR SHALL FIELD VERIFY EXISTING INVERT ELEVATION PRIOR TO CONSTRUCTION WHERE NOTED. 3. UNDERDRAIN LINES SHALL BE ADS N-12 S-P AND ARE DESIGNED TO MAINTAIN A MINIMUM 18" DEPTH FROM FINISH GRADE. 4. ALL CONVEYANCE PIPE SHALL BE PVC. MINIMUM REQUIRED O COVER FOR PVC PIPE IS 3 FEET. OO 5. ALL COLLECTOR PIPE SHALL BE ADS N-12 S-P. 00 6. ALL DETENTION TANK SHALL BE ALUMINIZED TYPE 2, MEETING SECTION 5.1.2 OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL. 7. PROVIDE CDF ABOVE THE EXISTING WATERLINE PER DETAIL 6 ON SHEET C3.9. ALL PROPOSED PIPE SHOWN ON THIS SHEET WILL BE PRIVATE z O Q GRAPHIC SCALE O 0 10 20 40 z w 1" = 20 FEET vJ 0 w LL J R-40281 1 _jO IN COMPLIANCE WITH CITY OF RENTON STANDARDS U cn LLJ J 0 0 2 McKNIGHT MIDDLE SCHOOL DA1/15/2019 ~ = FIELD IMPROVEMENTS FlELDBOOK: RENTON SCHOOL DISTRICT PAGE - DRAVANG NO: z C3.1 DRAINAGE PLAN SHEET:1 1 OF.