\-POINT 369
n
�OINT 57
N
GRAPHIC SCALE
0 50 100 200
1" = 100 FEET
SITE MAP
SCALE: 1 "=100'
y� J ,
py tPA,Sgj��l,1
1306
SHEET INDEX
SHEET
NUMBER
SHEET TITLE
C1.0
COVER SHEET
C1.1
STUDENT ACCESS
C2.0
TESC & DEMOLITION PLAN
C2.1
TESC & DEMOLITION PLAN
C2.2
TESC & DEMOLITION PLAN
C2.3
TESC & DEMOLITION PLAN
C2.4
TESC NOTES & LEGEND
C2.5
TESC NOTES & DETAILS
C2.6
TESC NOTES & DETAILS
C3.0
DRAINAGE PLAN
C3.1
DRAINAGE PLAN
C3.2
DRAINAGE PLAN
C3.3
DRAINAGE PLAN
C3.4
STORM DRAINAGE PROFILES
C3.5
NOTES & DETAILS
C3.6
NOTES & DETAILS
C3.7
NOTES & DETAILS
C3.8
NOTES & DETAILS
C3.9
UNDERDRAIN DETAILS
C4.0
GRADING, PAVING & HORIZONTAL CONTROL PLAN
C4.1
GRADING, PAVING & HORIZONTAL CONTROL PLAN
C4.2
GRADING, PAVING & HORIZONTAL CONTROL PLAN
C4.3
PAVEMENT NOTES & DETAILS
C4.4
DRAINAGE NOTES AND DETAILS
L1.0
PLANTING PLAN
L1.1
PLANTING PLAN
L1.2
PLANTING PLAN
L2.0
IRRIGATION DEMO
L2.1
IRRIGATION PLAN
L2.2
IRRIGATION PLAN
L2.3
IRRIGATION PLAN
L2.4
IRRIGATION DETAILS
AS -BUILT 4v ■_
�.� EGISTEg� 1�
I CERTIFY THAT THE INFORMATION SHOWN HEREON IONAL
• WHICH WAS AS -BUILT BY AHBL, AND MAY INCLUDE 1/07/2019
0 LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND
AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING - -
ALTERATAIN OF THIS DMENT SHALL INVXMTE THE
FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY ONMSEAL AND SNHATURE.PUBUTATIONOF
THIS DOMWW DOES NOT DEROGATE HIM RESERVED
Know what'sbelOW. DIRECT SUPERVISION ON THIS DATE: 11/7/2019. 0011ERSHIP WM IN ff. THIS DOWN7 � TACOMA SEATTLE•SPOKANE•TRI-CITIESONLY WINE PRUW DENIM WINE 1
AND IS NOT TO BE USED FOR REPAIR R0100EL OR
call before you dig. AHBL PROJECT NO.2180059 ADDTRON TO THAT PROkECT OR FOR ANY OTHER PRo M. 1200 6th Avenue, Suite 1620 Seattle, WA 98101 N0,
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB
TEMPORARY BENCHMARK
TBM #1
AHBL #100
NAIL AND WASHER
N:186930.6371
E:1306766.9234
ELEV:356.63
TBM #2
AHBL #101
NAIL AND WASHER
N:187118.1267
E:1306675.4727
ELEV: 354.06
TBM #3
AHBL #102
NAIL AND WASHER
N:186990.8120
E:1306488.4359
ELEV:351.91
TBM #4
AHBL #103
REBAR AND CAP
N:187112.9252
E:1306223.8651
ELEV:343.64
UTILITIES / SERVICES
WATER:
CITY OF RENTON
PHONE:
(425)-430-7210
SANITARY SEWER:
CITY OF RENTON
PHONE:
(425)-430-7332
STORMWATER:
CITY OF RENTON
PHONE:
(425)-430-7332
POWER:
PUGET SOUND ENERGY
PHONE:
1-888-321-7779
GAS:
PUGET SOUND ENERGY
PHONE:
1-888-321-7779
PHONE:
CENTURY LINK
PHONE:
1-800-244-1111
ONE CALL:
1-800-424-5555
LEGAL
DESCRIPTION
TBM #5
AHBL #104
REBAR AND CAP
N:186922.5518
E:1306223.5816
ELEV:338.86
POR S 1/2 OF NW 1/4 OF SW 1/4 OF SW 1/4 & SW 1/4 OF SW 1/4 OF
SW 1/4 LESS RDS
GENERAL NOTE
1. CONSTRUCTION SURVEY SHALL BE PROVIDED BY THE CONTRACTOR.
TRENCH NOTE
IF WORKERS ENTER ANY TRENCH OR OTHER EXCAVATION FOUR OR MORE
FEET IN DEPTH THAT DOES NOT MEET THE OPEN PIT REQUIREMENTS OF
WSDOT SECTION 2-09.3(3)B, IT SHALL BE SHORED AND CRIBBED. THE
CONTRACTOR ALONE SHALL BE RESPONSIBLE FOR WORKER SAFETY AND
AHBL ASSUMES NO RESPONSIBILITY. ALL TRENCH SAFETY SYSTEMS SHALL
MEET THE REQUIREMENTS OF THE WASHINGTON INDUSTRIAL SAFETY AND
HEALTH ACT, CHAPTER 49.17 RCW.
AUTOCAD FILE
AN AUTOCAD DRAWING FILE IS AVAILABLE TO ASSIST WITH SITE LAYOUT.
PLEASE NOTE THAT ELECTRONIC FILES ARE PROVIDED FOR CONTRACTOR'S
CONVENIENCE AND SHALL NOT REPLACE NOR BE USED TO SUBSTITUTE THE
CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR PROJECT
LAYOUT ACCORDING TO CONTRACT DOCUMENTS AND COST FOR ELECTRONIC
AUTOCAD FILES.
PHONE: (253) 383-2422
FAX: (253) 383-2572
CONTACT: WILLIAM FIERST, P.E.
FILL SPECIFICATION
FILL MATERIAL SHALL NOT CONTAIN PETROLEUM PRODUCTS, OR SUBSTANCES
WHICH ARE HAZARDOUS, DANGEROUS, TOXIC, OR WHICH OTHERWISE VIOLATE
ANY STATE, FEDERAL, OR LOCAL LAW, ORDINANCE, CODE, REGULATION, RULE,
ORDER, OR STANDARD.
EARTHWORK INFORMATION
:1 LaKe
arenas
00 Lake Washington
Apartments
WE
x
Gene Coulon
Memorial Pinnacle 01) Lake
Beach Park Washbgton Apartments
W
�pa�kpr
THE LANDING
N t S4
Fry's Electronics
APPROX. 286 CUBIC YARDS CUT
APPROX. 2208 CUBIC YARDS FILL
NET: APPROX. 1,922 CUBIC YARD FILL
NOTE: THE ABOVE QUANTITIES ARE ESTIMATES ONLY INTENDED FOR THE PERMITTING PROCESS AND
ARE NOT TO BE USED BY THE CONTRACTOR FOR BIDDING PURPOSES. THE CONTRACTOR SHALL MAKE
THEIR OWN EARTHWORK DETERMINATION.
ONSITE SOILS SHALL BE RE -USED TO THE MAXIMUM EXTENT FEASIBLE.
CONTRACTOR SHALL OBTAIN IMPORT MATERIALS AND DISPOSE OF EXPORT MATERIALS AT APPROVED
LOCATIONS TO BE DETERMINED PRIOR TO THE START OF CONSTRUCTION ACTIVITIES.
INSPECTION NOTIFICATION
CITY OF RENTON DEPARTMENT OF
COMMUNITY & ECONOMIC DEVELOPMENT,
DEVELOPMENT SERVICES
1055 SOUTH GRADY WAY
RENTON, WA. 98057
PH: (425) 430-7200
PRECONSTRUCTION
A1^TC1�+
1. THE CONTRACTOR IS REQUIRED TO NOTIFY THE DEVELOPMENT SERVICES
DIVISION, LAND USE INSPECTION SECTION (425) 430-7200, THREE DAYS PRIOR TO
THE BEGINNING OF CONSTRUCTION FOR A PRECONSTRUCTION CONFERENCE
AND SPECIFICALLY REQUEST
INSPECTION BEFORE BEGINNING:
A. INSTALLING SILTATION AND EROSION CONTROL MEASURES
B. CLEARING AND GRUBBING
C. EARTHWORK
D. INSTALLATION OF ANY UNDERGROUND UTILITY
E. BEFORE PLACING SUBBASE, BASE OR PAVING SURFACES
F. INSTALLATION OF ANY FORMS OR PLACING ANY CONCRETE
OWNER
RENTON SCHOOL DISTRICT
7812 S 124TH ST
SEATTLE, WA 98178
PH: (425) 204-4479
CONTACT: STEWART SHUSTERMAN
BASIS OF BEARING VERTICAL DATUM
NAD 83/91
CITY OF RENTON CONTROL NETWORK
HOLDING POINT NUMBERS 57 AND 369.
POINT 57 - 3" BRASS DISC IN CASE AT
INTERSECTION OF NE 12TH STREET AND
EDMONDS AVENUE NE.
N=186452.8651
E=1306190.3942
POINT 369 - BRASS DISC IN CASE LYING IN
CENTER OF EDMONDS AVENUE NE
APPROXIMATELY 185 FEET NORTHERLY OF
INTERSECTION WITH NE 20TH STREET.
N=189092.0330
E=1306215.3062
NAVD 88
CITY OF RENTON CONTROL NETWORK HOLDING
POINT NUMBERS 57 AND 369.
POINT 57 - 3" BRASS DISC IN CASE AT
INTERSECTION OF NE 12TH STREET AND
EDMONDS AVENUE NE. ELEVATION=326.43'
POINT 369 - BRASS DISC IN CASE LYING IN
CENTER OF EDMONDS AVENUE NE
APPROXIMATELY 185 FEET NORTHERLY OF
INTERSECTION WITH NE 20TH STREET.
ELEVATION = 332.57'
CIVIL ENGINEER /
LANDSCAPE ARCH
/ SURVEYOR
AHBL, INC.
2215 NORTH 30TH STREET
SUITE 300
TACOMA, WA 98403
PH. (253) 383-2422
FAX (253) 383-2572
CIVIL CONTACT: ADAM BRAUN, P.E. OR
ANNE TURPIN, P.E.
LANDSCAPE ARCH CONTACT: KRISTIN
GLANDON, P.L.A.
SURVEY CONTACT: DAVID
FOLLANSBEE, P.L.S.
CONSTRUCTION RECORD DRAWINGS
SURVEYED:
DESIGNED:
STORM DRAINAGE REVISIONS AMT 09/20/2019 ACB DRAWN: AMT
ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS AMT 01 28 2019 ACB CHECKED:
BJS
REVISION BY DATE APPR APPROVED:
WJF
SCALE:
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 19M
HORIZONTAL NAD 1983/1991
DATUM
SITE
NF J14d M
LOCATION
.f
SE 104e
ar
CL
z
S•
C1~
McKnight Middle a0
m
toodwill Denton
h
s
rt
�
z NE 131h PI
�
r°r
e
m
�
m
Nf 171h st
ME 121h st
Tree
• )011ar ]
p�tk Ar
yg -15
NF 11thpi
6t�-
W'j
x
11
a
m
t
NE 1 lth St
9
t
r�i
,
a
z
NE I h1h PI
a
a
hif s et
C
r
NE Tfllh P!
NF. 1DIh St
NE loth I n
°
iw
NE A
3
m
INC 19th SI
N!: 9111 PI
NE 7th S!
z
°
m
NF 'S ?
w
4
kJr •r
VICINITY MAP
SCALE: 1" = 1,000'
SITE INFORMATION
SITE ADDRESS:
1200 EDMONDS AVENUE NE, RENTON, WA 98056
PARCEL NUMBER:
7227801860,0423059048
SECTION, TOWNSHIP, RANGE:
SW 1/4, SECTION 4, TOWNSHIP 23 NORTH, RANGE 05 EAST, WILLAMETTE MERIDIAN
PARCEL AREA:
20.39 ACRES
N
PROJECT AREA:
3.34 ACRES
UTILITY NOTES
1. SURFACE UTILITY FACILITIES ARE SHOWN HEREON PER FIELD LOCATED VISIBLE EVIDENCE. THERE
MAY BE UTILITIES THAT EXIST ON THIS SITE OTHER THAN THOSE GRAPHICALLY DEPICTED HEREON.
2. UNDERGROUND (BURIED) UTILITIES SHOWN HEREON ARE BASED ON COMBINATIONS OF VISIBLE
SURFACE EVIDENCE, UTILITY LOCATOR MARKINGS AND RECORD DATA (SUCH AS AS -BUILT OR
UTILITY DESIGN DRAWINGS). ALL UNDERGROUND UTILITIES SHOWN HEREON ARE APPROXIMATE
AND, IN SOME CASES, ARE SHOWN AS STRAIGHT LINES BETWEEN FIELD LOCATED SURFACE UTILITY
FACILITIES. UNDERGROUND UTILITIES MAY HAVE BENDS, CURVES OR CONNECTIONS WHICH ARE NOT
SHOWN.
3. ALTHOUGH LOCATIONS OF UNDERGROUND UTILITIES BASED ON UTILITY LOCATOR MARKINGS AND
RECORD DATA (SUCH AS AS -BUILT OR UTILITY DESIGN DRAWINGS) ARE DEEMED RELIABLE, AHBL,
INC ASSUMES NO LIABILITY FOR THE ACCURACY OF SAID DATA
C)
Lo
co
T
��
O
0
I
rr
z
4. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE APPROXIMATE ONLY AND HAVE NOT O
BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL
DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND Q
AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES THAT HAPPEN DUE TO THE
CONTRACTOR'S FAILURE TO LOCATE EXACTLY AND PRESERVE ANY AND ALL UNDERGROUND
UTILITIES. Q
5. CALL 1-800-424-5555 BEFORE ANY CONSTRUCTION. z
w
CITY OF
1;R] RENTON
Planning/Building/Public Works Dept.
0
J
W
LL
Q
J
R-402801 a
0
IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0
McKNIGHT MIDDLE SCHOOL
FIELD IMPROVEMENTS
RENTON SCHOOL DISTRICT
COVER SHEET
vJ
Ljj
0
0
=
DATE
1/15/2019
FIELDBOOK:
PAGE
_
z
DRAWING NO:-
C1.0
2
SHEET: OF.
1 32
O
N
LO
O
O
00
T
Iql-
O
O
O
M
W
cry,
n
Z
O
O
Z
W
rY
VJ
J
W
H
Q
J
n
J
O
O
U
w
J
r)
0
Z
U
00
N
O
O
0
w
z
O
Q
O
z
w
0
w_
H
J
n
J
O
O
U
LU
CO
G
2
0
z
U
G
0
LO
N
W
Q
Z
w
s41W(2 c �\
1 X-
I EXISTI
I
G
TENNIS
I
COURTS
I
I
i
I
I
I
I
EXISTING SCHOOL PARKING
/ i I (TYP)
/ SF 1 I
/ 1
5
I \ �(TYP)
� 11
� I l
6
� (TYP)
*Aftft is
all
■■mommoft■ m
MgTCHQNE ■ i4ft
SHEET
C2.2
A 42-01 111 T
• WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE
LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND
AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING
FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY
Know what's beIOW. DIRECT SUPERVISION ON THIS DATE: 11/7/2019.
Call before you dig. AHBL PROJECT NO.2180059
\ 2
\ (TYP) \ �,�0
G�
BENck .: .
11 6 BLEACRS
(TYP)
1 (TYP) 11
1 �
}7/���
T � /
MgTcy`
SyFFT c�
.2
■
1 _ ■
— F—< 6
9
STC8#501 TYPE 2
RIM:353.60
"CPP NE IE:346. ■
12' CPP SW IE:346.33
'_AD E-o `1
LLO
M
3
■N
U
w
14 w
2
O U)
■ LJJ
� 5 ■ J
(TYP) _
Q
■
(TYP)
CONSTRUCTION f
■"W V V STORM DRAINAGE REVISIONS
FAC0MA•SEATTLE•SPOKANE•TRI-CITIES Al ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS
1200 6th Avenue, Suite 1620 Seattle, WA 98101 NO. REVISION
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB
SURVEYED:
DESIGNED:
AMT 09/20/2019 AC B DRAWN. AMT
AMT 01 28 2019 ACB CHECKED:
Bis
BY DATE APPR APPROVED:
WJF
I
I
I
BASE BID_
KEYNOTES
ODEMOLISH AND/OR SALVAGE IRRIGATION ITEM. REFER TO
LANDSCAPE PLANS FOR ADDITIONAL INFORMATION.
OPROTECT EXISTING CHAIN LINK FENCE.
O3 DEMOLISH ASPHALT PATH.
4O PROTECT EXISTING TREE.
OSEE LANDSCAPE FOR IRRIGATION REMOVAL. SEE
GENERAL NOTE 1 THIS SHEET.
O6 PROTECT EXISTING ASPHALT SURFACE.
O7 PROTECT IRRIGATION.
O8 PROTECT EXISTING UTILITY.
OPROTECT EXISTING 8-INCH CITY WATER MAINS DURING
CONSTRUCTION OF IMPROVEMENTS.
10 NOT USED
11 PROTECT BLEACHERS, BENCHES AND TRASH CANS.
12 DEMOLISH BENCHES. SEE LANDSCAPE PLANS FOR
REPLACEMENT BENCHES.
13 REMOVE FENCE AS NEEDED FOR DETENTION SYSTEM
INSTALLATION. SALVAGE FOR REINSTALLATION.
14 TEMPORARY SEDIMENT TRAP
15 INTERCEPTOR SWALE 1
C2.6
GENERAL NOTE
1. COORDINATE DEMOLITION, SALVAGE,
INSTALLATION AND SLEEVING OF
IRRIGATION COMPONENTS WITH
DEMOLITION AND PAVEMENT
INSTALLATION.
2. SEE IRRIGATION DEMO PLAN L2.0 FOR
DEMOLITION OF IRRIGATION SYSTEM.
3. WET SEASON EROSION CONTROL
MEASURERS SHALL BE APPLICABLE
FROM OCTOBER 1ST TO APRIL 30T"
GRAPHIC SCALE
0 10 20 40
1" = 20 FEET
ORD DRAWINGS
SCALE
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 19M
HORIZONTAL NAD 1983/1991
DATU M
KEYMAP
CITY OF
RENTON
Planning/Building/Public Works Dept.
TESC LEGEND
INLET SEDIMENT PROTECTION
CLEARING LIMITS
SILT FENCE
SEDIMENT TRAP EMERGENCY
OVERFLOW
INTERCEPTOR SWALE (COR
STD. PLAN 217.10)
CHECK DAM (COR STD. PLAN
217.40)
2
C2.5
v v v 3
C2.5
4
C2.5
C2.6
00 2
C2.6
DEMOLITION LEGEND:
IRRIGATION ROTOR SEE L2.0 FOR DEMOLITION Ah
NOZZLE SEE L2.0 FOR DEMOLITION ®®OO
NOZZLE --SOFTBALL FIELDS, BASEBALL & SOCCER
FIELDS SEE L2.0 FOR DEMOLITION tl� D 0
REMOTE CONTROL VALVE SEE L2.0 FOR DEMOLITION
QUICK COUPLER VALVE SEE L2.0 FOR DEMOLITION
•
IRRIGATION LINE SEE L2.0 FOR DEMOLITION
SAWCUT LINE
DEMOLISH EXISTING PAVEMENT
O
N
L0
O
00
T
67 u
z
0
a
O
z
w
0
J
W
LL
Q
J
R-402803 0
IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0
McKNIGHT MIDDLE SCHOOL
FIELD IMPROVEMENTS
RENTON SCHOOL DISTRICT
TESC & DEMOLITION PLAN
U
w
J
0
=
DATE
1/15/2019
FIELDBOOK:
PAGE
_
z
DRAWING NO:
C2.0
2-1
SHEET: OF.
3 32
00
N
O
O
0
w
z
O
Q
O
z
w
0
w
H
a
J
n
J
O
O
U
LU
0
CO
G
0
z
U
G
0
LO
N
W
zz
w
■
O ■
N ■
U
LU
LU
U)
LU ■
z
■ 5
(TYP)
■
5
■ (TYP)
■ MATCHLINE-�
■ SHEET C2.2
-�� ■ ■ —
A 42-01 111 T
• WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE
0 LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND
AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING
FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY
Know what's beIOW. DIRECT SUPERVISION ON THIS DATE: 11/7/2019.
Call before you dig. AHBL PROJECT NO.2180059
� 00
(TYP)
I
Mq, P�0
EXISTING ASPHALT
ACCESS DRIVE
EXISTING —
BASKETBALL
COURTS
TESC LEGEND
INLET SEDIMENT PROTECTION
CLEARING LIMITS
SILT FENCE
STABILIZED CONSTRUCTION
ENTRANCE
(COR STD. PLAN 215.10)
INTERCEPTOR SWALE (COR
STD. PLAN 217.10)
CHECK DAM (COR STD. PLAN
217.40)
BASE BID_
®2
C2.5
v v v 3
C2.5
1
C2.5
C2.6
o, 2
000
C2.6
KEYNOTES
/ DEMOLISH AND/OR SALVAGE IRRIGATION ITEM. REFER TO
O LANDSCAPE PLANS FOR ADDITIONAL INFORMATION.
2O PROTECT EXISTING CHAIN LINK FENCE.
O3 DEMOLISH ASPHALT PATH.
1 4O PROTECT EXISTING TREE.
OSEE LANDSCAPE FOR IRRIGATION REMOVAL. SEE
GENERAL NOTE 1 THIS SHEET.
O6 PROTECT EXISTING ASPHALT SURFACE.
O7 PROTECT IRRIGATION.
O8 PROTECT EXISTING UTILITY.
O9 REMOVE SECTION OF CHAIN LINK FENCE.
10 PROTECT EXISTING 8-INCH CITY WATER MAINS DURING
CONSTRUCTION OF IMPROVEMENTS.
11 PROTECT BLEACHERS, BENCHES AND TRASH CANS.
DEMOLISH EXISTING ASPHALT PATH. CONTRACTOR MAY
12 USE AS PART OF CONSTRUCTION ENTRANCE UNTIL
FAILURE AT WHICH TIME IT SHALL BE REPLACED FOR
PROPER CONSTRUCTION ENTRANCE.
13 PROTECT EXISTING MANGATE.
14 NOT USED
15 INTERCEPTOR SWALE 1
C2.6
16 TEMPORARY STUDENT ACCESS WALK
GRAPHIC SCALE
0 10 20 40
1" = 20 FEET
CONSTRUCTION RECORD DRAWINGS
L" W V V STORM DRAINAGE REVISIONS
FAC0MA•SEATTLE•SPOKANE•TRI-CITIES Al ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS
1200 6th Avenue, Suite 1620 Seattle, WA 98101 NO. REVISION
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB
SURVEYED:
DESIGNED:
AMT 09/20/2019 AC B DRAWN. AMT
AMT 01 28 2019 ACB CHECKED:
BJS
BY DATE APPR APPROVED:
WJF
SCALE:
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
DEMOLITION LEGEND:
VERTICAL: NAVD 19M
HORIZONTAL NAD 1983/1991
DATU M
IRRIGATION ROTOR SEE L2.0 FOR DEMOLITION Ah
NOZZLE SEE L2.0 FOR DEMOLITION ©®O
NOZZLE --SOFTBALL FIELDS, BASEBALL & SOCCER
FIELDS SEE L2.0 FOR DEMOLITION ll� 00
REMOTE CONTROL VALVE SEE L2.0 FOR DEMOLITION
QUICK COUPLER VALVE SEE L2.0 FOR DEMOLITION
IRRIGATION LINE SEE L2.0 FOR DEMOLITION
SAWCUT LINE
DEMOLISH EXISTING PAVEMENT
GENERAL NOTE
1. COORDINATE DEMOLITION, SALVAGE,
INSTALLATION AND SLEEVING OF
IRRIGATION COMPONENTS WITH
DEMOLITION AND PAVEMENT
INSTALLATION.
2. SEE IRRIGATION DEMO PLAN L2.0 FOR
DEMOLITION OF IRRIGATION SYSTEM.
3. STUDENT ACCESS TO WALKING PATH
MUST BE MAINTAINED THROUGHOUT
CONSTRUCTION. INSTALL THE
TEMPORARY ACCESS PATH PRIOR TO
BEGINNING CONSTRUCTION. REMOVE
THE PATH AND RE-ESTABLISH LAWN AT
THE COMPLETION OF CONSTRUCTION.
DAMAGE TO IRRIGATION SYSTEM SHALL
BE REPAIRED AT CONTRACTOR EXPENSE.
yii a
NN
14
0 �
KEYMAP
CITY OF
RENTON
Planning/Building/Public Works Dept.
67 u
O
O
CIS
z
O
\Q
O
z
w
0�
�r
VJ
0
w
LL
J
n
R-402804 -i
O
IN COMPLIANCE WITH CITY OF RENTON STANDARDS O
McKNIGHT MIDDLE SCHOOL
FIELD IMPROVEMENTS
RENTON SCHOOL DISTRICT
TESC & DEMOLITION PLAN
2
U
J
0
0
=
DATE
1/15/2019
FIELDBOOK:
PAGE
_
z
DRAWING NO:
C2.1
SHEET: OF.
4 32
00
N
't
CD
w
z
O
Q
>
O
z
w
rr
0
w
LL
a
J
n
O
O
U
w
C0
G
z
U
LO
0
N
lil
zz
w
MATCHLINE SHEET C2.3
I■■�■■�■■�■■�
1 1 I
I •
/ (TYP)
6
(8" CPP NE
21" LID
8" CPP N
4" CPP S
8" CPP
z
m
N
cn
m
m
°
HARRINGTON AVE NE
J . FJ ■
pF WASft,,
r_
z
m
cn
m
m
N
■
AS -BUILT
I CERTIFY THAT THE INFORMATION SHOWN HEREON �'`%NAL
• WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE 1/07/2019
0 LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND
AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING - - mm
ALTERATION OF THIS DOCUMENT SHALL INVALDATE THE �
FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY ONAL SEAL ANDSNHaTURE.vuBL�c70OF a) THIS DOCUMENT DOES NOT DEROGATE FROM RESERVED
Know whars beloW. DIRECT SUPERVISION ON THIS DATE: 11/7/2019. 011INERSHIP WM IN ff. THIS DOMNIM � TAC0MA•SEATTLE•SPOKANE•TRI-CITIES
ONLY FM THE PRUW DENTIFB IN THE AND IS NOT TO BE USED FOR REPAlk REMODEL OR
Call before you dig. AHBL PROJECT NO.2180059 ADDITION TO THAT PROkECT OR FOR ANY OTHER PRGECT. 1200 6th Avenue, Suite 1620 Seattle, WA 98101
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com wEE
CONSTRUCTION RECORD DRAWINGS
STORM DRAINAGE REVISIONS AMT EO1
/20/20
1 ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS AMT 28 20
NO. REVISION BY DATE
SURVEYED:
DESIGNED:
9 AC B DRAwN. AMT
9 ACB CHECKED:
BJS
A P P R APPROVED:
WJF
SCALE:
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL NAD 1983/1991
DATUM
ALTERNATE BID NO. 1 0
DEMOLITION LEGEND:
GENERAL NOTE
IRRIGATION ROTOR SEE L2.0 FOR DEMOLITION 1. COORDINATE DEMOLITION, SALVAGE,
INSTALLATION AND SLEEVING OF
NOZZLE SEE L2.0 FOR DEMOLITION ©® +0 IRRIGATION COMPONENTS WITH
DEMOLITION AND PAVEMENT
NOZZLE --SOFTBALL FIELDS, BASEBALL & SOCCER INSTALLATION.
FIELDS SEE L2.0 FOR DEMOLITION 0 2. SEE IRRIGATION DEMO PLAN L2.0 FOR
DEMOLITION OF IRRIGATION SYSTEM.
REMOTE CONTROL VALVE SEE L2.0 FOR DEMOLITION
QUICK COUPLER VALVE SEE L2.0 FOR DEMOLITION
IRRIGATION LINE SEE L2.0 FOR DEMOLITION
SAWCUT LINE
DEMOLISH EXISTING PAVEMENT
TESC LEGEND
INLET SEDIMENT PROTECTION
CLEARING LIMITS
SILT FENCE
SEDIMENT TRAP EMERGENCY
OVERFLOW
INTERCEPTOR SWALE (COR
STD. PLAN 217.10)
CHECK DAM (COR STD. PLAN
217.40)
TREE PROTECTION FENCING
(COR STD. PLAN 217.40)
3
C2.5
4
C2.5
C2.6
2
GRAPHIC SCALE
Z 0 10 20 40
1" = 20 FEET
KEYMAP
CITY OF
1;R) RENTON
NUF
Planning/Building/Public Works Dept.
KEYNOTES
DEMOLISH AND/OR SALVAGE IRRIGATION ITEM.
0 REFER TO LANDSCAPE PLANS FOR ADDITIONAL
INFORMATION.
2O PROTECT EXISTING CHAIN LINK FENCE.
O3 DEMOLISH ASPHALT PATH.
OIF EXISTING FENCE IS REMOVED, PROTECT 1
EXISTING TREE WITH FENCING PER DETAIL. L1.2
OSEE LANDSCAPE FOR IRRIGATION REMOVAL. SEE
GENERAL NOTE 1 THIS SHEET.
O6 PROTECT EXISTING ASPHALT SURFACE.
O7 PROTECT IRRIGATION.
O8 PROTECT EXISTING UTILITY.
O9 REMOVE SECTION OF CHAIN LINK FENCE.
10 DEMOLISH EXISTING TREE.
11 PROTECT EXISTING UTILITY
ABANDON PIPE IN PLACE UNDER ASPHALT PATH.
12 CAP OR GROUT PIPE END TO PROVIDE WATERTIGHT
SEAL.
13 NOT USED
14 TEMPORARY SEDIMENT TRAP
1
O
O
O
00
T
A �
u
O
O
15 INTERCEPTOR SWALE C2.6 Z
O
16 DEMOLISH STORM PIPE AND/OR STRUCTURE
Q
O
z
w
U)
0
J
w
LL
Q
J
R-402805 _j
0
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
McKNIGHT MIDDLE SCHOOL
FIELD IMPROVEMENTS
RENTON SCHOOL DISTRICT
TESC & DEMOLITION PLAN
U
cn
J
0
0
2
DATE:
1/15/2019
=
FIELDBOOK:
PAGE
_
DRAWING NO:
z
C2.2
SHEET: OF.
5 32
00
N
O
0
w
z
O
Q
O
z
w
0
w
H
a
J
n
J
O
O
U
w
J
0
C0
G
0
z
U
0
LO
0
N
z
Know what's below.
Call before you dig.
AS -BUILT
I CERTIFY THAT THE INFORMATION SHOWN HEREON
WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE
LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND
AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING
FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY
DIRECT SUPERVISION ON THIS DATE: 11/7/2019.
AHBL PROJECT NO. 2180059
y J. �r
TgA,$JI���
�.�� d'EGISTEg�9 i
s`sIONA�Cs
1/07/2019
ALTERATION OF THIS DOONIENT SHALL INNALDATE THE
PROFESSIONAL SEAL AND SIGNATURE. PUBLICATION OF
THIS DOCUIENT DOES NOT DEROGATE FROM RESERVED
ONNERSHP ROHM N FE THIS DOCINENT IS FOR USE TACO M A • SEATTLE • SPOKANE •TRI-CITIES
ONLY FOR THE PRO,ECT IDENTIFIED N THE 7FRE BLOCK
AND IS NOT TO BE USED FOR WAR, REMODEL OR
ADDFRON TO 1HAT PROECT OR FOR ANY OTTER PRGIECF. 1200 6th Avenue, Suite 1620 Seattle, WA 98101
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB
MATCHLINE SHEET C2.2
L
GRAPHIC SCALE
0 10 20 40
1" = 20 FEET f
ALTERNATE BID NO. 1
TESC LEGEND
INLET SEDIMENT PROTECTION
CLEARING LIMITS
SILT FENCE
®2
C2.5
3
C2.5
NOTE
1. COORDINATE DEMOLITION, SALVAGE,
INSTALLATION AND SLEEVING OF
IRRIGATION COMPONENTS WITH
DEMOLITION AND PAVEMENT
INSTALLATION.
2. SEE IRRIGATION DEMO PLAN L2.0 FOR
DEMOLITION OF IRRIGATION SYSTEM.
0
KEYNOTES
O1 DEMOLISH AND/OR SALVAGE IRRIGATION ITEM. REFER TO Q
LANDSCAPE PLANS FOR ADDITIONAL INFORMATION. N
L0
O2 PROTECT EXISTING CHAIN LINK FENCE. O
O
0 NOT USED. co
O4 PROTECT EXISTING TREE. U
OSEE LANDSCAPE FOR IRRIGATION REMOVAL. SEE
GENERAL NOTE 7.
O6 PROTECT EXISTING ASPHALT SURFACE.
0 PROTECT IRRIGATION.
O8 PROTECT EXISTING BASIN FOR NEW 8" STORM PIPE.
O9 NOT USED.
Q
10 DEMOLISH EXISTING TREE.
O
11 NOT USED. Q
12 ABANDON PIPE IN PLACE. CAP OR GROUT PIPE END TO OI
PROVIDE WATERTIGHT SEAL.
T
rr
DEMOLITION LEGEND:
IRRIGATION ROTOR SEE L2.0 FOR DEMOLITION Ah
NOZZLE SEE L2.0 FOR DEMOLITION ©®O
NOZZLE --SOFTBALL FIELDS, BASEBALL & SOCCER
FIELDS SEE L2.0 FOR DEMOLITION ll� DO
REMOTE CONTROL VALVE SEE L2.0 FOR DEMOLITION
QUICK COUPLER VALVE SEE L2.0 FOR DEMOLITION
IRRIGATION LINE SEE L2.0 FOR DEMOLITION
SAWCUT LINE
CONSTRUCTION RECORD DRAWINGS
STORM DRAINAGE REVISIONS I AMT 109/20/20191 ACB
Al 1ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS I AMT 101/28/20191 ACB
NO.
REVISION
SURVEYED:
DESIGNED:
DRAWN:
AMT
CHECKED:
BJS
APPROVED:
WJF
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL NAD 1983/1991
DATU M
/// j�\\\
%j N\
� X ;;
C2.3
KEYMAP
CITY OF
RENTON
Planning/Building/Public Works Dept.
R-402806
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
McKNIGHT MIDDLE SCHOOL
FIELD IMPROVEMENTS
RENTON SCHOOL DISTRICT
TESC & DEMOLITION PLAN
DATE:
1/15/2019
PAGE
C2.3
SHEET: OF.
I; 32
z
O
Q
O
z
w
0
W
H
Q
0-
J
O
O
2
U
LU
0
0
I—
/2
V
z
U
5
G
00
N
O
F
O
F
W
z
O
Q
O
z
W
rr
cn
0
J
W_
U_
a
J
n
J
O
O
U
cn
W
J
0
0
z
CU
G
0
LO
N
W
zz
w
EROSION CONTROL NOTES:
1. THESE NOTES SHALL APPEAR FOR ALL PROJECTS - SITE
IMPROVEMENTS, SURFACE WATER UTILITY, WASTEWATER
UTILITY, WATER UTILITY, AND TRANSPORTATION PLANS:
2. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY
OCCURS, A PRE -CONSTRUCTION MEETING MUST BE HELD
WITH THE CITY OF RENTON, PUBLIC WORKS DESIGN
ENGINEER.
3. THE BOUNDARIES OF THE CLEARING LIMITS AND AREAS OF
VEGETATION PRESERVATION AS PRESCRIBED ON THE
PLAN(S) SHALL BE CLEARLY FLAGGED BY SURVEY TAPE OR
FENCING IN THE FIELD PRIOR TO CONSTRUCTION IN
ACCORDANCE WITH APPENDIX D OF THE SURFACE WATER
DESIGN MANUAL AND OBSERVED DURING CONSTRUCTION.
DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE
BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE
CLEARING LIMITS SHALL BE MAINTAINED BY THE
APPLICANT/ESC SUPERVISOR FOR THE DURATION OF
CONSTRUCTION.
4. STABILIZED CONSTRUCTION ENTRANCES SHALL BE
INSTALLED AT THE BEGINNING OF CONSTRUCTION AND
MAINTAINED FOR THE DURATION OF THE PROJECT.
ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL
WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO
ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND
TRACK OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR
THE DURATION OF THE PROJECT.
5. ALL REQUIRED SEDIMENTATION/EROSION CONTROL
FACILITIES MUST BE CONSTRUCTED AND IN OPERATION
PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO
PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE
WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES.
ALL EROSION AND SEDIMENT FACILITIES SHALL BE
MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH
TIME THAT CLEARING AND/OR CONSTRUCTION IS
COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS
PASSED. THE IMPLEMENTATION, MAINTENANCE,
REPLACEMENT AND ADDITIONS TO
EROSION/SEDIMENTATION CONTROL SYSTEMS SHALL BE
THE RESPONSIBILITY OF THE PERMITEE.
6. THE EROSION AND SEDIMENTATION CONTROL SYSTEMS
DEPICTED ON THIS DRAWING ARE INTENDED TO BE
MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE
CONDITIONS. AS CONSTRUCTION PROGRESSES AND
UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE
PERMITEE SHALL ANTICIPATE THAT MORE EROSION AND
SEDIMENTATION CONTROL FACILITIES WILL BE NECESSARY
TO ENSURE COMPLETE SILTATION CONTROL ON THE
INSPECTION SCHEDULE:
PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION,
IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE
PERMITEE TO ADDRESS ANY NEW CONDITIONS THAT MAY
BE CREATED BY THE ACTIVITIES AND TO PROVIDE
ADDITIONAL FACILITIES, OVER AND ABOVE MINIMUM
REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT
ADJACENT PROPERTIES AND WATER QUALITY OF THE
RECEIVING DRAINAGE SYSTEM.
7. APPROVAL OF THIS PLAN IS FOR EROSION/SEDIMENTATION
CONTROL ONLY. IT DOES NOT CONSTITUTE AN APPROVAL
OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF
PIPES, RESTRICTORS, CHANNELS, OR RETENTION
FACILITIES.
8. ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY
EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO
DAYS DURING THE WET SEASON (OCTOBER 1ST THROUGH
MARCH 30TH) OR SEVEN DAYS DURING THE DRY SEASON
(APRIL 1ST THROUGH SEPTEMBER 30) SHALL BE
IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER
METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING,
ETC.).
9. WET SEASON SEASONAL EROSION AND SEDIMENT
CONTROL REQUIREMENTS APPLY TO ALL CONSTRUCTION
SITES CLEARING BETWEEN OCTOBER 1 AND MARCH 30
INCLUSIVE, UNLESS OTHERWISE APPROVED BY THE CITY
THROUGH AN ADJUSTMENT PROCESS.
10. COVER MEASURES WILL BE APPLIED IN CONFORMANCE
WITH APPENDIX D OF THE SURFACE WATER DESIGN
MANUAL.
11. ANY AREA NEEDING ESC MEASURES, NOT REQUIRING
IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN
SEVEN (7) DAYS DURING NON WET SEASON.
12. THE ESC FACILITIES ON INACTIVE SITES SHALL BE
INSPECTED AND MAINTAINED A MINIMUM OF ONCE A MONTH
OR WITHIN 24 HOURS FOLLOWING A STORM EVENT.
13. AT NO TIME SHALL MORE THAN ONE (1) FOOT OF SEDIMENT
BE ALLOWED TO ACCUMULATE WITHIN A CATCH BASIN. ALL
CATCH BASINS AND CONVEYANCE LINES SHALL BE
CLEANED PRIOR TO PAVING. THE CLEANING OPERATION
SHALL NOT FLUSH SEDIMENT- LADEN WATER INTO THE
DOWNSTREAM SYSTEM.
1. ALL ESC MEASURES SHALL BE MAINTAINED AND REVIEWED ON A REGULAR
BASIS.
2. THE ESC SUPERVISOR SHALL REVIEW THE SITE AT LEAST WEEKLY AND
WITHIN 24 HOURS OF SIGNIFICANT STORMS. A SIGNIFICANT STORM IS ONE
WITH MORE THAN 0.5 INCHES OF RAIN IN 24 HOURS OR LESS.
3. THE CITY MAY REQUIRE THAT A WRITTEN RECORD OF THESE REVIEWS BE
KEPT ON SITE WITH COPIES SUBMITTED TO THE CITY WITHIN 48 HOURS.
HYDROSEEDING NOTES:
1. HYDROSEEDING SHALL BE APPLIED TO ALL AREAS DISTURBED BY
CONSTRUCTION ACTIVITIES UNLESS OTHERWISE NOTED.
2. HYDROSEEDING TO BE AS SPECIFIED IN LANDSCAPE
SPECIFICATIONS.
3. APPLICATION TO BE 100 LBS/ACRE.
4. 500 LBS/ACRE 10-20-20 FERTILIZER, 2000 LBS/ACRE MULCH AND 40
LBS/ACRE SOIL STABILIZER TO BE APPLIED WITH SEED MIXTURE.
5. SEED BEDS PLANTED BETWEEN MAY 1 AND OCTOBER 31 WILL
REQUIRE IRRIGATION AND OTHER MAINTENANCE AS NECESSARY
TO FOSTER AND PROTECT THE ROOT STRUCTURE. CONTRACTOR
SHALL ENSURE PROPER ROOT GROWTH REGARDLESS OF
PLANTING SCHEDULE.
6. FOR SEED BEDS PLANTED BETWEEN OCTOBER 31 AND APRIL 30,
ARMORING OF THE SEED WILL BE NECESSARY. (EG, GEOTEXTILES,
JUTE MAT, CLEAR PLASTIC COVERING.)
7. BEFORE SEEDING, INSTALL NEEDED SURFACE RUNOFF CONTROL
MEASURES SUCH AS GRADIENT TERRACES, INTERCEPTOR DIKES,
SWALES, LEVEL SPREADERS AND SEDIMENT BASINS.
8. THE SEEDBED SHALL BE FIRM WITH A FAIRLY FINE SURFACE,
FOLLOWING SURFACE ROUGHENING. PERFORM ALL OPERATIONS
ACROSS OR AT RIGHT ANGLES TO THE SLOPE.
9. FERTILIZERS ARE TO BE USED ACCORDING TO SUPPLIERS
RECOMMENDATIONS. AMOUNTS USED SHOULD BE MINIMIZED,
ESPECIALLY ADJACENT TO WATER BODIES AND WETLANDS.
10. SEE SPECIFICATIONS FOR HYDROSEED MIXTURES.
MULCHING NOTES:
14. ANY PERMANENT RETENTION/DETENTION FACILITY USED AS
A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH
THE NECESSARY EROSION CONTROL MEASURES AND
SHALL PROVIDE ADEQUATE STORAGE CAPACITY.
15. PRIOR TO THE BEGINNING OF THE WET SEASON (OCT. 1),
ALL DISTURBED AREAS SHALL BE REVIEWED TO IDENTIFY
WHICH ONES CAN BE SEEDED IN PREPARATION FOR THE
WINTER RAINS. DISTURBED AREAS SHALL BE SEEDED
WITHIN ONE WEEK OF THE BEGINNING OF THE WET
SEASON. A SKETCH MAP OF THOSE AREAS TO BE SEEDED
AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE
SUBMITTED TO THE CITY OF RENTON FOR REVIEW.
16. ALL TESC MEASURES MUST BE REMOVED AFTER
CONSTRUCTION AND SITE IS STABILIZED.
17. DISTURBED AREAS UNWORKED FOR 7 CONSECUTIVE
WORKING DAYS SHALL BE STABILIZED WITH COVER
MEASURES EXCEPT DURING THE WET SEASON. DURING
THE WET SEASON DISTURBED AREAS UNWORKED FOR TWO
CONSECUTIVE WORKING DAYS SHALL BE STABILIZED WITH
COVER MEASURES.
18. STOCKPILES AND STEEP CUT AND FILL SLOPES SHALL BE
PROTECTED IF UNWORKED FOR MORE THAN 12 HOURS.
19. COVER MATERIALS SUFFICIENT TO COVER ALL DISTURBED
AREAS SHALL BE STOCKPILED ON SITE.
20. ALL AREAS THAT ARE TO BE UNWORKED DURING THE WET
SEASON SHALL BE SEEDED WITHIN ONE WEEK OF THE
BEGINNING OF THE WET SEASON.
21. MULCH IS REQUIRED TO PROTECT ALL SEEDED AREAS.
22. FIFTY LINEAR FEET OF SILT FENCE (AND THE NECESSARY
STAKES) PER ACRE OF DISTURBANCE SHALL BE
STOCKPILED ON SITE.
23. CONSTRUCTION ROAD AND PARKING LOT STABILIZATION
ARE REQUIRED FOR ALL SITES UNLESS THE SITE IS
UNDERLAIN BY COARSE -GRAINED SOIL.
24. ANY RUNOFF GENERATED BY DEWATERING SHALL BE
REQUIRED TO DISCHARGE TO THE SANITARY SEWER (WITH
APPROPRIATE DISCHARGE AUTHORIZATION), PORTABLE
SAND FILTER SYSTEMS, OR HOLDING TANKS.
1. MULCH MATERIALS USED SHALL BE HAY OR STRAW, AND SHALL BE
APPLIED AT THE RATE OF 2 TONS/ACRE.
2. MULCHES SHALL BE APPLIED IN ALL AREAS WITH EXPOSED
SLOPES GREATER THAN 2:1.
3. MULCHING SHALL BE USED IMMEDIATELY AFTER SEEDING OR IN
AREAS WHICH CANNOT BE SEEDED BECAUSE OF THE SEASON.
4. ALL AREAS NEEDING MULCH SHALL BE COVERED BY NOVEMBER 1.
SOIL NOTES:
A. PROTECT THE SOIL MOISTURE HANDLING CAPACITY OF ALL NEW
PERVIOUS SURFACING THAT, AT PROJECT COMPLETION, WILL NOT
BE COVERED BY IMPERVIOUS SURFACING OR INCORPORATED INTO
A DRAINAGE FACILITY. THE DUFF LAYER AND NATIVE TOPSOIL SHALL
BE RETAINED IN AN UNDISTURBED STATE TO THE MAXIMUM EXTENT
FEASIBLE.
B. ANY DUFF LAYER OR TOPSOIL REMOVED DURING GRADING SHALL
BE STOCKPILED ONSITE IN A DESIGNATED, CONTROLLED AREA NOT
ADJACENT TO PUBLIC RESOURCES AND CRITICAL AREAS. THE
MATERIAL SHALL BE REAPPLIED TO OTHER PORTIONS OF THE SITE
WHERE FEASIBLE.
C. AMEND THE SOIL TO MITIGATE FOR LOSS OF MOISTURE HOLDING
CAPACITY IN ANY AREA THAT HAS BEEN COMPACTED OR THAT HAS
HAD SOME OR ALL OF THE DUFF LAYER OR UNDERLYING TOPSOIL
REMOVED. THE AMENDMENT SHALL TAKE PLACE BETWEEN MAY 1
AND OCTOBER 1. REPLACED TOPSOIL SHALL BE A MINIMUM OF 8
INCHES THICK. REPLACED TOPSOIL SHALL HAVE AN ORGANIC
MATTER CONTENT BETWEEN 8 AND 13 PERCENT DRY WEIGHT AND A
PH SUITABLE FOR THE PROPOSED LANDSCAPE PLANTS. SEE
LANDSCAPE PLANS FOR MORE DETAILS.
y J. �r
WASfJj���
AS -BUILT ��w� ■1
I CERTIFY THAT THE INFORMATION SHOWN HEREON gE���
• WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE o��ssIONAL1/07/2019 _
0 LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND
AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING -D -
ALTERATION OF THIS DOCUMENT SHALL INVALDATE THE �
FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY SON&SEa mSmiuRE.vum7mOF 13
THIS DOM ENT DOES NOT OEROGAIE FROM RESERVED
Know what's beloW. DIRECT SUPERVISION ON THIS DATE: 11/7/2019. � TACOMA SEATTLE•SPOKANE TRI-CITIES
OWY FM THE PRUM MTIFB IN THE AND IS NOT TO BE USED FOR REPAIR, R0100EL OR
Call before you dig. AHBL PROJECT NO.2180059 ADDITION TO THAT PROkECT OR FOR ANY OTHER PRGECT. 1200 6th Avenue, Suite 1620 Seattle, WA 98101
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB
GENERAL NOTES:
1. DEMOLITION: IT IS THE INTENT OF THE WORK UNDER
THIS CONTRACT TO INCLUDE THE DEMOLITION OF ALL
EXISTING SITE IMPROVEMENTS AS INDICATED BY THIS
DRAWING OR AS REQUIRED FOR NEW CONSTRUCTION.
IT IS THE CONTRACTOR'S RESPONSIBILITY TO FULLY
REVIEW THE SITE CONDITIONS AND TO CORRELATE
THESE OBSERVATIONS WITH THE PROJECT WORK AND
INCLUDE ALL NECESSARY DEMOLITION, WHETHER
SHOWN OR NOT, AND INCLUDE ALL SUCH COSTS IN THE
BASE BID.
2. CLEARING: IT IS THE INTENT OF THE WORK UNDER THIS
CONTRACT TO CONDUCT ALL CLEARING NECESSARY TO
BE ABLE TO COMPLETE ALL THE WORK OF THIS
PROJECT. CONTRACTOR SHALL PERFORM ADDITIONAL
CLEARING TO CONSTRUCT ONSITE AND OFFSITE
IMPROVEMENTS IF NECESSARY.
3. GENERAL CONTRACTOR SHALL PROVIDE AN ESC
SUPERVISOR WHO IS A CERTIFIED EROSION AND
SEDIMENT CONTROL LEAD.
4. CONTRACTOR SHALL CONFORM TO ALL REQUIREMENTS
OF THE NPDES UNDER THE DOE'S GENERAL PERMIT
FOR STORMWATER DISCHARGE FROM CONSTRUCTION
ACTIVITIES AND THE SWPPP. CONTRACTOR IS
RESPONSIBLE FOR MAINTAINING ALL REQUIRED
RECORDS.
5. CONTRACTOR SHALL LEGALLY DISPOSE OFF THE
OWNER'S PROPERTY, ALL DEMOLISHED AND REMOVED
MATERIALS, UNLESS INDICATED OTHERWISE.
6. BACKFILL AND COMPACT ALL VOIDS AND DEPRESSIONS
OCCURRING AS A RESULT OF DEMOLITION ACTIVITIES.
SEE SPECIFICATIONS FOR ALLOWABLE BACKFILL
MATERIALS.
7. REMOVE EXISTING SOD AND TOPSOIL AS NECESSARY
TO PROVIDE IMPROVEMENTS. CONTRACTOR SHALL
DISPOSE OF EXCESS SOD AND TOPSOIL OFFSITE.
8. CONTRACTOR IS RESPONSIBLE FOR MAINTENANCE OF
CONSTRUCTION SEQUENCE:
1. STAKE THE CLEARING LIMITS BEFORE THE PRE -CONSTRUCTION MEETING.
2. ARRANGE AND ATTEND PRE -CONSTRUCTION MEETING WITH CITY OF RENTON, OWNER,
CONTRACTOR, ESC LEAD, AND ENGINEER.
3. POST NOTICE OF CONSTRUCTION ACTIVITY SIGN WITH NAME AND PHONE NUMBER OF
ESC LEAD.
4. FENCE CLEARING LIMITS AND TREE PROTECTION AREAS.
5. INSTALL CATCH BASIN SEDIMENT PROTECTION.
6. INSTALL PERIMETER PROTECTION (SILT FENCE, OR OTHER MEASURES) WHERE
SPECIFIED ON THE ESC PLAN OR REQUIRED BY THE CITY INSPECTOR.
7. GRADE AND STABILIZE CONSTRUCTION ENTRANCE.
8. DEMOLISH EXISTING PAVEMENT AREAS AS INDICATED ON PLAN.
9. CONSTRUCT SURFACE WATER CONTROLS (INTERCEPTOR SWALES, CHECK DAMS,
TEMPORARY SEDIMENT POND, ETC.) SIMULTANEOUSLY WITH CLEARING AND GRADING
FOR PROJECT DEVELOPMENT.
10. PROVIDE PLASTIC COVERING ON ALL EXPOSED SLOPES 5HAV OR GREATER. ALL FILLS
MUST BE IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE GEOTECHNICAL
ENGINEER.
11. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH CITY OF RENTON
STANDARDS, NPDES PERMIT AND EROSION AND SEDIMENT CONTROL REPORT.
12. RELOCATE SURFACE WATER CONTROLS AND EROSION CONTROL MEASURES OR
INSTALL NEW MEASURES, SO THAT, AS SITE CONDITIONS CHANGE, THE EROSION AND
SEDIMENT CONTROL IS ALWAYS IN ACCORDANCE WITH THE CITY OF RENTON EROSION
AND SEDIMENT CONTROL REQUIREMENTS.
13. ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT
BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCT 1 TO APR 30) OR SEVEN
DAYS DURING THE DRY SEASON (MAY 1 TO SEPT 30) SHALL BE IMMEDIATELY
STABILIZED WITH THE APPROVED ESC MEASURES.
14. ROUGH GRADE SITE.
15. CONSTRUCT PERMANENT STORMWATER FACILITIES.
16. CONSTRUCT ALL OTHER SITE IMPROVEMENTS.
17. STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN SEVEN DAYS.
18. SEED OR SOD ANY AREA TO REMAIN UNWORKED FOR MORE THAN 30 DAYS.
19. UPON SUBSTANTIAL COMPLETION, ALL DISTURBED AREAS MUST BE STABILIZED.
EROSION AND SEDIMENT CONTROL MEASURES SHALL REMAIN IN PLACE UNTIL
APPROVAL IS OBTAINED FROM THE CITY OR RENTON.
20. TEST IRRIGATION SYSTEM.
TESC FACILITIES. CONTRACTOR IS RESPONSIBLE FOR
CONSTRUCTION OF ADDITIONAL FACILITIES INCLUDING
BUT NOT LIMITED TO FILTER FENCE, CATCH BASIN
PROTECTION, SWALES, MULCHING AND SEEDING.
9. RELOCATE EROSION CONTROL MEASURES OR INSTALL
NEW MEASURES SO THAT AS SITE CONDITIONS CHANGE
THE EROSION CONTROL IS ALWAYS IN ACCORDANCE
WITH THE MINIMUM CITY OF RENTON TESC
REQUIREMENTS.
10. SEDIMENTS TRACKED ONTO PAVED SURFACES SHALL
BE REMOVED BY SWEEPING. SEDIMENTS SHALL NOT BE
WASHED DOWNSTREAM. SPRAY EXPOSED SOILS WITH
WATER TO PREVENT DUST. RUNOFF SHALL NOT BE
CREATED BY SPRAYING. EROSION CONTROL MEASURES
SHALL BE PROVIDED THROUGHOUT CONSTRUCTION.
WHEEL WASHES SHALL BE PROVIDED IF THE NOTED
EROSION CONTROL MEASURES ARE NOT ADEQUATE TO
PREVENT SEDIMENTS FROM ENTERING THE ROW
11. CONTRACTOR SHALL EXCAVATE AND FILL AS
NECESSARY TO ACHIEVE SUBGRADES IN LAWN AND
PLANTER BEDS REQUIRED BY THE LANDSCAPE PLANS.
12. PROTECT EXISTING UTILITIES WITHIN THE WORK LIMITS
NOT SPECIFICALLY INDICATED FOR DEMOLITION.
ADJUST EXISTING UTILITIES TO FINISHED GRADE.
13. CONTRACTOR SHALL INCLUDE IN BID REMOVAL OF ALL
TESC MEASURES AT COMPLETION OF PROJECT.
14. SEE LANDSCAPE PLANS FOR FINAL VEGETATED
SURFACING.
15. CONTRACTOR IS REQUIRED TO USE EXISTING TRUCK
HAUL ROUTES AS NOTED PER CITY OF RENTON
ORDINANCE 5339. ORDINANCE 5339 SPECIFIES THAT
TRUCKS TAKE THE MOST DIRECT ARTERIAL ROUTE TO
OR FROM ONE OF THE DESIGNATED TRUCK ROUTES.
NE SUNSET BLVD (STATE HIGHWAY 900) SOUTH OF THE
SITE IS A DESIGNATED TRUCK ROUTE.
EXISTING LEGEND:
SURVEY
0
SET NAIL AND WASHER
MISCELLANEOUS
BOLLARD
SIGN AS NOTED
FENCE
SANITARY SEWER
SANITARY SEWER
MANHOLE
SANITARY SEWER
CLEANOUT
SANITARY SEWER LINE
STORM DRAINAGE
❑
STORM CATCH BASIN
❑0
STORM MANHOLE
®
ROOF DRAIN
-
STORM LINE
NATURAL GAS
GAS VALVE
GAS LINE
POWER
1 ,
ELECTRICAL VAULT
z
JUNCTION BOX
0
LUMINAIRE
- - - - P
ELECTRICAL LINE
- - - - T
COMMUNICATION LINE
TREES
C=CEDAR
CW=COTTONWOOD,
M=MAPLE,
U= UNKNOWN
SURFACING
CONCRETE
ASPHALT
CONTOUR MAJOR
- -XXX- -
INTERVAL
CONTOUR MINOR
- - - -XXX- - -
INTERVAL
PROPERTY/RIGHT-OF-WAY
LINE
CONSTRUCTION RECORD DRAWINGS
STORM DRAINAGE REVISIONS
1 ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS
NO. REVISION
SURVEYED:
DESIGNED:
AMT 09/20/2019 AC B DRAWN. AMT
AMT 01 28 2019 ACB CHECKED:
BJS
BY DATE APPR I APPROVED:
WJF
SCALE:
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL NAD 1983/1991
DATU M
CITY OF
RENTON
Planning/Building/Public Works Dept.
16. THE SITE TOPOGRAPHIC SURVEY WAS COMPLETED BY
THE OWNER'S CONSULTANT. PRIOR TO CONSTRUCTION
AND MOVING MATERIAL, THE CONTRACTOR SHALL
REVIEW THE SURVEY AND PROVIDE THE OWNER A
SIGNED LETTER INDICATING THE CONTRACTOR
AGREES WITH THE CONDITIONS NOTED BY THE
SURVEY. IF THE CONTRACTOR DOES NOT AGREE WITH
THE CONDITIONS OF THE SURVEY, THE CONTRACTOR
SHALL COMPLETE AN INDEPENDENT 3RD PARTY
SURVEY AND PROVIDE IT TO THE OWNER FOR REVIEW
PRIOR TO CONSTRUCTION OR MOVING MATERIAL.
NOTES
1. COORDINATE DEMOLITION AND SALVAGE
NECESSARY TO PROVIDE
OF IRRIGATION COMPONENTS WITH
IMPROVEMENTS. CONTRACTOR SHALL
IRRIGATION CONTRACTOR. COORDINATE
DISPOSE OF EXCESS SOD AND TOPSOIL
INSTALLATION OF IRRIGATION SLEEVING
ONSITE.
WITH PAVING INSTALLATION.
7.
SEDIMENTS TRACKED ONTO PAVED
2. DEMOLITION: IT IS THE INTENT OF THE
SURFACES SHALL BE REMOVED BY
WORK UNDER THIS CONTRACT TO
SWEEPING. SEDIMENTS SHALL NOT BE
INCLUDE THE DEMOLITION OF ALL
WASHED DOWNSTREAM. SPRAY
EXISTING SITE IMPROVEMENTS AS
EXPOSED SOILS WITH WATER TO
INDICATED BY THIS DRAWING OR AS
PREVENT DUST. RUNOFF SHALL NOT BE
REQUIRED FOR NEW CONSTRUCTION. IT
CREATED BY SPRAYING. EROSION
IS THE CONTRACTOR'S RESPONSIBILITY
CONTROL MEASURES SHALL BE
TO FULLY REVIEW THE SITE CONDITIONS
PROVIDED THROUGHOUT
AND TO CORRELATE THESE
CONSTRUCTION.
OBSERVATIONS WITH THE PROJECT
WORK AND INCLUDE ALL NECESSARY 8.
PROTECT EXISTING PLANTS AND
DEMOLITION, WHETHER SHOWN OR NOT,
VEGETATION TO REMAIN.
AND INCLUDE ALL SUCH COSTS IN THE
BASE BID. 9.
PROTECT EXISTING UTILITIES AND
PAVING WITHIN THE WORK LIMITS. RAISE
3. CLEARING: IT IS THE INTENT OF THE
EXISTING UTILITIES TO FINISHED GRADE.
O
N
L0
O
O
00
T
16
O
0
0
O
F
00
WORK UNDER THIS CONTRACT TO
REPLACE DAMAGED PAVING. PROTECT
z
CONDUCT ALL CLEARING NECESSARY TO
EXISTING UTILITIES AND PAVING BEYOND
O
BE ABLE TO COMPLETE ALL THE WORK
THE WORK LIMITS.
OF THIS PROJECT.
10.
HYDROSEED ALL NON -PAVED DISTURBED
Q
4. CONTRACTOR SHALL LEGALLY DISPOSE
AREAS FOR EROSION AND
OFF THE OWNER'S PROPERTY, ALL
SEDIMENTATION CONTROL PER SHEET
O
DEMOLISHED AND REMOVED MATERIALS,
C2.4.
z
UNLESS INDICATED OTHERWISE.
W
11.
CONTRACTOR SHALL HAVE THE OPTION
5. BACKFILL AND COMPACT ALL VOIDS AND
OF PERMANENT SODDING IN LIEU OF
DEPRESSIONS OCCURRING AS A RESULT
SEEDING FOR EROSION AND
(f�
OF DEMOLITION ACTIVITIES WITH
SEDIMENTATION CONTROL AT NO
0
APPROVED BACKFILL.
ADDITIONAL EXPENSE TO THE OWNER.
J
W
6. REMOVE EXISTING SOD AND TOPSOIL AS
Q
J
R-402807 a
0
IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0
McKNIGHT MIDDLE SCHOOL
FIELD IMPROVEMENTS
RENTON SCHOOL DISTRICT
TESC NOTES & LEGEND
U
J
0
=
DATE:
1/15/2019
FIELDBOOK:
PAGE
_
z
DRAWING NO:
C2.4
SHEET: OF.
7 32
00
N
O
0
W
I—
Z
O
I—
O
Z
W
�fr
V J
0
J
W_
1
a
I..L
J
O
O
2
U
J
0
C�
Z
U
0
to
ao
C4
w
Q
z
w
DRIVEWAYS SHALL BE PAVED TO THE EDGE
GROPD /
OF R-O-W PRIOR TO INSTALLATION OF THE
AVOID
DAMAGING OF THE ROADWAY
IT IS RECOMMENDED THAT THE
R = 25' MIN.
ENTRANCE BE CROWNED SO THAT
RUNOFF DRAINS OFF THE PAD
INSTALL DRIVEW1
IS A ROADSIDE DI
PER CITY ROAD E
5�•
12" MIN. THICKNESS PROVIDE FULL WIDTH OF
NOTES INGRESS/EGRESS AREA
1. CONDITION OF USE
1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON
PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE
GRABTENSILE STREBNGTH(ASTM D4751)
1200 PSI MIN.
GRAB TENSILE ELONGATION (ASTM D4632)
130%MAX.
MULLEN BURSTSTRENGTH (ASTM D3786-80A)
1400 PSI MIN.
AOS (ASTM D4751)
20-45 (U.S. STANDARD SIEVE SIZE)
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN ARES THAT WILL BOT BE USED
FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY
AT ANYTIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO
PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT.
2.2. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE.
2.3. WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SUBSTANTIALLY
INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE.
3. MAINTENANCE STANDARDS
3.1- QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS.
3.2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE
STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE
ENTRANCE, OR THE INSTALLATION OF THE WHEEL WASH- IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH
CRUSHED ROCK, AND WASHED WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND.
3.3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY
SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET,
EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS ATHREAT TO PUBLIC SAFETY. IF IT NECESSARY TO WASH THE STREETS, A
SMALL SUMP MUST BE CONDUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND
DISCHARGED APPROPRIATELY.
3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY.
3.5- IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE
INSTALLED TO CONTROL TRAFFIC.
O~ Y O STD. PLAN - 215.10
PUBLIC WORKS STABILIZED
DEPARTMENT CONSTRUCTION ENTRANCE MARCH 2O08
N
CONSTRUCTION ENTRANCE
(COR STD. PLAN 215.10)
NOT TO SCALE
BASE BID -
DRAINAGE GRATE _ rTRIM
GRATE FRAME
e d
p -
SEDIMENTANDDEBRIS v
OVERFLOW BYPASS
r D P p BELOW INLET GRATE DEVICE
FILTERED
WATER
e A A
SECTION VIEW
REC" DRAINAGE GRATE
-
ISOMETRIC VIEW
NOTES
1. Size the Below Inlet Grate Device (BIGD)forthe storm watershucture itwill service.
2. The BIGD shall have a built-in high -flow relief system (overflow bypass).
3. The retrieval system must allow removal of tits BIGD without spilling the collected material.
4. Perform maintenance in accordance With Standard Specification 8-01.3(15).
1 Y�O
PUBLIC WORKS
DEPARTMENT
=M (TYP.)
CATCH BASIN FILTER STD. PLAN — 216.30
MARCH 2O08
CATCH BASIN FILTER
(COR STD. PLAN 216.30)
NOT TO SCALE
JOINTS IN FILTER FABRIC SHALL BE SPLICED
AT POSTS. USE STAPLES, WIRE RINGS, OR
FDI IIVAI FNT T ATTM.H FARRI(: Tr] P(VgT
6' MAX.
u
�
POST SPACING MAY BE INCREASED
TO F IF WIRE BACKING IS USED
2'S2" BY 14 G.. WIRE OR
EQUIVALENT, IF STANDARD
STRENGTH FABRIC USED
FILTER FA
MINIMUM 411' TRENCH
BACKFILL TRENCH WITH
NATIVE SOIL
2W WOOD POSTS, STEEL FENCE /
POSTS, REBAR, OR EQUIVALENT
NOTES
1. CONDITION OF USE
1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS.
1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW.
ANY CONCENTRATED FLOW MOST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND.
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. THE GEOTEXTILE USED MOST MET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MOST BE
AVAILABLE ON SITE.
ail: SIEVE SIZE(Q60-0.15KMF FOR SILT FILM
ADS (ASTM D4751)
50-100SIEVE SIZE a.300.15 FOR OTHER FABRICS
WATER PERMITRVITY ASTM D491
0.02 SECII MINIMUM
180 LBS' MIN. FOR EXTRA STRENGH FABRIC
GRAB TENSILE STRENCHT(ASTM D4632)
100 LBS. MIN. FOR STANDARD STRENGHr FABRIC
GRABTENSILE ELONGATION ASTM D4632
30%MAX.
ULTRAVIOLATE RESISTANCE(ASTM D4355)
70%MIN.
2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST
SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE.
2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1 V
2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4X4 TRENCH MAY NOT BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE
IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT
FENCE.
3. MAINTENANCE STANDARDS
3.1. ANY DAMAGE SHALL BE REPAIR IMMEDIATELY.
3.2. IF CONCENTRATED FLOES ARE EVIDENT UPHILL OD THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND.
3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND
THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVED THE TRAP
SEDIMENT.
3.4. SEDIMENT MOST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH.
3.5. IF THE FILTER FABRIC (GEOTE)CTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED.
PUBLIC WORKS
+ i DEPARTMENT
SILT FENCE
SILT FENCE
(COR STD. PLAN 214.00)
NOT TO SCALE
4'
4 BERM
BERM
TOP _OF_BERM =_35616 ?51
0
— — — — EMERGENCY OVERFLOW = 355.16
— — — — — — — — — 55 —
EXISTING
EXISTING \ �1 1 GROUND
GROUND —
BOTTOM OF POND 351.66
MIN.
BASEBALL FIELD SEDIMENT TRAP -SECTION
(COR STD. PLAN 211.00)
NOT TO SCALE
AS -BUILT
/" EGISTEg�
��s10NAL
I CERTIFY THAT THE INFORMATION SHOWN HEREON
MLOCATIONS,
WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE
1/07/2019
0
ELEVATIONS, DEPTHS, PIPE SIZES, AND
AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING
- -
FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY
ALTERATION OF THIS DMOIT SHALL INVM IMTE THE
lSE&MSIWIURE.Pueuc70OF
Knowwhatrs belOW.
DIRECT SUPERVISION ON THIS DATE: 11/7/2019.
THIS DOD11QlT DOES NOT DEROGATE FROM RESOM
TACO MA SEATTLE SPOKANE TRI-CITIES 1
call before dig.
AHBL PROJECT NO.2180059
AND IS NOT TO BE USED FOR REPAIR 1110100EL OR
ADDITION TO THAT PROECT OR FOR ANY OM PRo M.
1200 6th Avenue, Suite 1620 Seattle, WA 98101
you
N0.
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB
STD. PLAN — 214.00
MARCH 2O08
rl MIN
1'-;O�ERFLONTOEPTM
T E�TylytlYtl)rlJF
—� [II �iONSTRUCTEDAY
F1W SEDIMENT. BTORAGE Y
VDEPTN3147'=1,`--YMd WASH=PGRAVEL
CRclift, SECTI6W
HIM
NOT&
MAY' BE CONSTRUCTED BY' EXCVA]lON
OR -B,Y' $�Qk_D_tN9,A BERM
A� SE01ME--NT `1 "P
7T► 1 ` I I
SEDIMENT TRAP
(COR STD. PLAN 211.00)
NOT TO SCALE
FALTER FABRIC FENCING
M. PLAN G "00-
��i�REIT �IrYEi
4'
4 BERM
BERM
? �0 TOP OF BERM=_3500_0 ?�1
0
1 0�\ — — — — EMERGENCY OVERFLOW = 349.00
— — — — — — — — — 49 —
3 3 /�/ EXISTING
EXISTING \ 1 GROUND
GROUND—
BOTTOM OF POND 345.50
MIN.
SOCCER FIELD SEDIMENT TRAP -SECTION
(COR STD. PLAN 211.00)
NOT TO SCALE
CONSTRUCTION RECORD DRAWINGS
SURVEYED: SCALE
NAD 1983/1991
DESIGNED: AS SHOWN HORIZONTAL
STORM DRAINAGE REVISIONS AMT 09/20/2019 ACB DRAWN• AMT
ONE INCH DATU M
ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS AMT 01 28 2019 ACB CHECKED,,. AT FULL SCALE
IF NOT ONE INCH
REVISION BY DATE A P P R APPROVED: SCALE ACCORDINGLY
WJF
CITY OF
RENTON
Planning/Building/Public Works Dept.
ALTERNATE BID NO
O
^ 'N
L J
C)
MO
W
T
co
0
0
I
.1 Z
O
Q
O
Z
0 w
0�
Cn
0
w
H
Q
J
O
IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0
McKNIGHT MIDDLE SCHOOL
FIELD IMPROVEMENTS
RENTON SCHOOL DISTRICT
TESC NOTES & DETAILS
U
U)
J
0
=
DATE
1/15/2019
FIELDBOOK:
PAGE
_
Z
DRAWING NO:—
C2.5
SHEET: OF.
g 32
O
N
LO
O
O
00
T
Iql-
O
O
O
M
W
cry,
n
Z
O
O
Z
W
rY
VJ
J
W
H
Q
J
n
J
O
O
U
w
J
r)
0
Z
U
0
LO
ao
N
W
zz
w
V
O
2
't C3.4
g tF-
11 P - 126, 26 LF
W O CB 04-\
Sw�Nc
cq TF 1
C3.4
O I. A
O� CB01
> O
O P - 140, 12 LF /
z
W ' P - 146, 36 LF
U) -
0
J
BASEpib oov��� \
o '� \ / ■
P - 173, 1 8 LF \ / ■
P�948,3LF \\ /
/ P-176,2LF
FENCE -
--
-----
�/ P - 145, 185 LF, 5'O---------� ■
-D - _ - CB06
_----------- - \ \
All
-- -- ^f� -� TYP.
W
v
I
LL
'
v
a
J
�
�
I
J
I
O
v
I
=
I�
CU
ILL
ILL.
V i
W
JLL
ti
r
- J
J
�
0
r-
1-
LL
J
0
l in
co
0
I
1�
C
G
1
(L
Ln
D
P-138,93LF
• - 2
- 047-F C3.4
D D D D■
10 P - 89, 173 LF 10 10 P 39, LF ■
3.8 TYP. D DTYP. TYP. • • • • • P - 92, 120 LF
D D
,' 7 P - 88, 174 LF
-P - 149, DF TYP. D P - 141,112 LF, 5'QS r P - 93, 137 LF D
\ P - 87, 163 LF ■
9D 3g� P - 142, 112 LF, 5'0 P - 94, 153 LF ■ 0
D W
D P - 86, 152 LF D P - 143, 1112 LF, SO W
\ P - 144,112 LF, 5'0 - 95, 142 LF =
\ \ D D P - 85,141 LF P - 165, 112 LF, 50 ■ W
P - 96, 131 LF
D D D _j D J
P - 84, 130 LF 10
TYP. P - 97, 120 LF D U
\ \ D P - 83, 119 LF 355D Q
8 P - 98, 108 LF ■
D
// \ D P - 82 8 LF D ■
/ \ 7 TYP. P - 99, 98 LF
/ \ 97 LF
YP. F(- 10
P - 127, 253 LF \ D D D _■
i \ P-80,86LF ��� ■
J \
P-101,74LF
' D D
coI� \ D P - 79, 75 LF 8 I 10 TYP.
� N LL TYP. / P - 102, 68 LF
Ln 00 D I D
o_ m ` P - 78, 68 LF ■
cY,l / r 35:6�
z I co C/ Lo o LLp _ �::: :. :. P- 103, 57 LF D ■
/ n- LO w ILL. P - 77, 57 LF
U I cg J \ Z z
I I d 0000 LL \ � /cli � I P - 104, 46 LF 2
I J D *, : .. D C3.4
� LL y : :: P - 105, 35 LF
J
a
F:: ■
I r Ln LL P - 136, 35 LF z.: 7 /
rn
(0 c� \ I P - 106, 24
7 v TYP. M y J
TYP. ` n cN ALL - 135, 24 LF P - 134, 14 LF / I ^ M
I a i9 \\N P - 107, 14 LF o
i I � _ 9'i ■
o d
■
6 r
H1u M } + ST H
jj
Y x-x-x-
\: BE�iCH. :: : ; TYP.:: .:
1
BLEAC S: 6 TRq C3.4
BLEACHERS.::
Cq� S P - 108, 14 LF
■ /------------
■ ■ CB 10 �� ------ ^-�\\-■
MATCH■�� ss ■
LINE
C3. 2 o
■
4;1 4
q T` 11
y/ 16$ CB 09 ■
Pipe Table
Pipe Table
PIPE NAME
SIZE (in)
INVERT
ELEVATION
SLOPE
PIPE NAME
SIZE (in)
INVERT
ELEVATION
SLOPE
P - 76
4
354.49
1.54%
P - 96
4
353.64
0.81 %
P - 77
4
354.41
1.62%
P - 97
4
353.84
0.88%
P - 78
4
354.33
1.66%
P - 98
4
354.05
1.00%
P - 79
4
354.24
1.80%
P - 99
4
354.25
1.12%
P - 80
4
354.11
1.77%
P - 100
4
354.42
1.26%
P - 81
4
353.92
1.67%
P - 101
4
354.50
1.29%
P - 82
4
353.77
1.64%
P - 102
4
354.51
1.15%
P - 83
4
353.50
1.51 %
P - 103
4
354.57
1.15%
P - 84
4
353.29
1.45%
P - 104
4
354.64
1.17%
P - 85
4
353.05
1.38%
P - 105
4
354.70
1.10%
P - 86
4
352.92
1.39%
P - 106
4
354.77
1.07%
P - 87
4
352.74
1.36%
P - 107
4
354.83
1.12%
P - 88
4
352.54
1.33%
P - 88
4
354.70
0.16%
P - 89
4
352.44
1.44%
P - 109
4
354.67
0.75%
P - 90
4
352.57
2.84%
P - 110
4
354.63
0.93%
P - 91
4
352.76
2.18%
P - 126
8
345.00
1.68%
P - 92
4
352.92
1.43%
P - 127
8
354.45
1.92%
P - 93
4
353.08
1.01 %
P - 132
4
354.77
1.40%
P - 94
4
353.28
0.72%
P - 134
4
354.93
1.93%
P - 95
4
353.47
0.78%
P - 135
4
354.79
1.70%
N 187044.25
E 1306519.76
N 186866.36
E 1306787.27
LEGEND:
STORM STRUCTURE TABLE
STRUCTURE NAME
STRUCTURE DETAILS
CB 01
RIM = 352.21
CB TYPE 1
IE =9 (4" S)
N 187025.70
IE =349.68 (8" NE)
E 1306488.73
IE =349.69 (8" E)
CB 03
RIM=352.38
60" TYPE 2 CB
IE=346.99 (36" NE)
N 187033.48
IE = 345.00 (8" NW)
E 1306498.18
IE = 348.79 (8" SW)
CB 04
48" TYPE 2 CB
RIM = 35233-
N 187038.82
IE =344-88 (8" SE)
E 1306494.39
IE =33 .86(,14" NE, SW)
CB 09
RIM=353.64
AREA DRAIN
IE=359-58 (8" W)
N 186888.79
IE=358.58 (8" NE)
E 1396:7:78.99-
CB 10
AREA DRAIN
RIM 363.61
N 186852.35
IE=351.28 (8" E)
E 1306658.76
■ STORM CATCH BASIN
Q■ STORM MANHOLE
® DETENTION TANK ACCESS RISER
- - - - GB GRADE BREAK
D STORM LINE
PERFORATED PIPE STORM LINE
DETENTION TANK 1 2
C3.4 C3.4
XXX CONTOUR LINE
PROPERTY/RIGHT-OF-WAY LINE
FLOW DIRECTION
n ADS N-12 S-P, 4" CAP
N GRAPHIC SCALE
0 10 20 40
I=i =� -
`�� I = 20 FEET
yy� ,Y WASgj����j
W CONSTRUCTION RECORD DRAWINGS
AS -BUILT �� w� ■_
�.� EGISTEg�
I CERTIFY THAT THE INFORMATION SHOWN HEREON �SSIONAL E�SURVEYED:
• WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE 1/07/2019
LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND DESIGNED:
AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING - -
umESM OF THIS L DOCI1SIDI sHML INVMDA7E THE STORM DRAINAGE REVISIONS AMT 09/20/2019 AC B DEW" AMT
FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY ON�LSEaLaNDSNwaTUNE.vuBucATIa+aF
THIS DOMNIM DOES NOT DEROGATE FM RESERVED
Know what's beloW. DIRECT SUPERVISION ON THIS DATE: 11/7/2019. DOERSHIP WIM N ff. THIS DOMMM � TACOMA SEATTLE•SPOKANE TRI-CITIES 1 ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS AMT 01 28 2019 ACB CHECKED:
OWY FM THE PRMW MIFEI) IN THE AND IS NOT TO BE USED FOR FOAR, FBIODEL OR
Call before you dig. AHBL PROJECT NO.2180059 AWN M IIHAT MIXEM OR FAR ANYmNER MM. 1200 6th Avenue, Suite 1620 Seattle, WA98101 NO. REVISION BY DATE APPR APPROVED:
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB WJF
0.43%
Pipe Table
PIPE NAME
SIZE (in)
UPPER
INVERT
ELEVATION
SLOPE
P - 136
4
354.64
1.63%
P - 140
4
349.99
1.65%
P - 141
60
344.50
0.00%
P - 142
60
344.50
0.00%
P - 143
60
344.50
0.00%
P - 144
60
344.50
0.00%
P - 145
60
344.50
0.00%
P - 146
8
349.60
6 62
P - 148
36
345.00
0.00%
P - 149
4
349.96
3.03%
P - 150
4
351.15
0.74%
P - 151
4
351.39
0.74%
P - 152
4
351.63
0.74%
P - 153
4
351.93
0.79%
P - 154
4
352.21
0.83%
P - 155
4
352.50
0.90%
P - 156
4
352.75
0.93%
P - 157
4
353.00
0.99%
P - 158
4
353.29
1.1 1 %
P - 159
4
353.56
1.21
IE = 349.85 (4" S)
IE = 349.63 (8" NE)
IE = 349.70 (8" E)
RIM = 352.58
IE = 344.86 (36" NE)
RIM = 352.27
IE = 344.83 (8" SE)
IE = 344.77 (14" NE, SW)
IE = 348.92 (4" S)
DISCOVERED DURING CONSTRUCTION
RIM = 353.70
IE = 350.70 (8" W)
IE = 350.70 (8" NE)
RIM = 353.44
IE = 351.57 (8" E)
ix NN
X ��
0
C3.3
KEYMAP
SCALE:
VERTICAL*
AS SHOWN HORIZONTAL- N1983/1991
CITY OF
RENTON
ONE INCH DATUM
AT FULL SCALE Planning/Building/Public Works Dept.
IF NOT ONE INCH
SCALE ACCORDINGLY
KEYNOTES:
2.24%
Pipe Table
PIPE NAME
SIZE (in)
UPPER
INVERT
ELEVATION
SLOPE
P - 160
4
353.84
1.36%
P - 161
4
354.03
1.40%
P - 162
4
354.22
1.48%
P - 163
4
354.39
1.51 %
P - 164
4
354.54
1.57%
P - 165
60
344.50
0.00%
P - 166
4
350.90
0.52%
P - 167
4
354.65
1.43%
P - 168
8
351.28
0.60%
P - 169
8
350.50
1.14%
P - 173
60
344.50
0.00%
P - 176
1 60
345.50
0.22%
TYPE 1 CATCH BASIN
10
WITH HERRINGBONE
1
GRATE
C3.N
O
TYPE 1 CATCH BASIN
1
2
WITH SOLID COVER
C3.5
TYPE 2 CATCH BASIN
O3
WITH HERRINGBONE
2
GRATE
C3.5
OWITH
TYPE 2 CATCH BASIN
ROUND SOLID LID
2
C3.5
FLOW CONTROL
1
O5
MANHOLE
C3.8
OCLEANOUT
COLLECTOR DRAIN
2
C3.9
NOTES:
O
N
LO
00
T
16
4" PERFORATED 3
OUNDERDRAIN, TYP. C3.9
O Iql-
8" COLLECTOR DRAIN 4 (D8 O
C3.9 Q
CONNECTION TO OO
O9 COLLECTOR
DRAIN, TYP. C3.9
DETENTION TANK 4
10 ACCESS RISER, TYP. C3.8
CONVEYANCE PIPE
11
1. SEE SHEETS C3.5 FOR GENERAL STORM DRAINAGE NOTES.
2. CONTRACTOR SHALL FIELD VERIFY EXISTING INVERT
ELEVATION PRIOR TO CONSTRUCTION WHERE NOTED.
z
3. UNDERDRAIN LINES SHALL BE ADS N-12 S-P AND ARE
O
DESIGNED TO MAINTAIN A MINIMUM 18" DEPTH FROM FINISH
GRADE.
Q
4. ALL CONVEYANCE PIPE SHALL BE PVC. MINIMUM REQUIRED
O
COVER FOR PVC PIPE IS 3 FEET.
z
5. ALL COLLECTOR PIPE SHALL BE ADS N-12 S-P.
U-1
6. ALL DETENTION TANK SHALL BE ALUMINIZED TYPE 2, MEETING
U)
SECTION 5.1.2 OF THE CITY OF RENTON SURFACE WATER
DESIGN MANUAL.
0
J
7. PROVIDE CDF ABOVE THE EXISTING WATERLINE PER DETAIL 6
LU
ON SHEET C3.9.
LL
ALL PROPOSED PIPE SHOWN ON THIS
Q
SHEET WILL BE PRIVATE
J
a_
R-40281 0
J
O
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
O
U
LU
0
0
2
McKNIGHT MIDDLE SCHOOL
DATE. 2019
~
FIELD IMPROVEMENTS
FlELDBOOK:
=
RENTON SCHOOL DISTRICT
PAGE
-
DRAVANG NO:
z
DRAINAGE PLAN
SHEET:OF.
R
10 F:32
G
W
N
O
0
W
z
O
Q
>
O
z
w
rr
0
LLJ
LL
J
n
J
O
O
U
J
C0
G
I-
z
U
G
O
to
N
lil
zz
w
P - 137, 11 LF O8
f\ �
_ IJ
P - 90, 87 LF
D CB 05 O
2 P-138,93LF
C3.4 ■ ",P - 91,104 LF D
P - 92, 120 LF 11
D D pp-
■ P - 93, 137 LF
D D
■
P - 94, 153 LF
D D•
P - 95, 142 LI
■
P - 96, 131 LF
D
P - 97, 120 LF
D D
■
■ P - 98, 108 LF D
7 TYP.
P - 99, 98 LF
L D
P-101,74LFD \\ /
1`13 if),) co 1 17
0
LL
J
/ LL 00
J � �
� M
JILL. U �
co N '
� r �
^� r
2
C3.4 ■
■
/r
0
Uj
-Y_Y-
BENCH: : ; \
■
■
■
A'T
ft
■ (0 �
■
G
A A r\ ■ ■ ■ ■ T
LL
J
r
11
oil
D �g-
D -
/
P - 128
203 LF
ILL
LL
J
co
r i
\
J
N
N
r
r
r
LL
r
00
r
i
J
r
r
r
o
r
r
r
C
r
`
� I �
11'
I. TYP.
• WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE
LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND
AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING
FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY
Know what's beIOW. DIRECT SUPERVISION ON THIS DATE: 11/7/2019.
Call before you dig. AHBL PROJECT NO.2180059
P-129,70LF O
�CB 07 O
9
/ P - 133, 77 LF O8
0
0
1 PIN
/07/2019
�r ■rr r r
TA C O M A• SEATTLE • SPOKANE •TRI-CITIES
1200 6th Avenue, Suite 1620 Seattle, WA 98101 I NO.
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com wEE
Pipe Table
PIPE NAME
SIZE (in)
UPPER
INVERT
ELEVATION
SLOPE
P - 90
4
352.57
2.84%
P - 91
4
352.76
2.18%
P - 92
4
352.92
1.43%
P - 93
4
353.08
1.01 %
P - 94
4
353.28
0.72%
P - 95
4
353.47
0.78%
P - 96
4
353.64
0.81 %
P - 97
4
353.84
0.88%
P - 98
4
354.05
1.00%
P - 99
4
354.25
1.12%
P - 100
4
354.42
1.26%
P - 101
4
354.50
1.29%
P - 102
4
354.51
1.15%
P - 103
4
354.57
1.15%
P - 104
4
354.64
1.17%
P - 111
4
354.60
1.08%
P - 112
4
354.57
1.16%
P - 113
4
354.54
1.19%
P - 114
4
354.51
1.23%
P - 115
4
354.33
1.1 1 %
STORM STRUCTURE TABLE
STRUCTURE NAME
STRUCTURE DETAILS
CB 05
RIM =2-
48" TYPE 2 CB
IE
=349.95-(8" E)
N 187170.87
IE =395
(8" SW)
E 1306773.24
IE
=349.95-(8" W)
CB 06
RIM =354.17
54" TYPE 2 CB
IE=346.99-(36"
SW)
N 187129.26
IE
=347-95 (8" NE)
E 1306689.88
RIM = 354.19
CB 07
IE
=352.99 (8" SE)
48" TYPE 2 CB
IE
=352+7 (4" SE)
N 187162.12
IE=352-1-(4"
SW)
E 1306842.53
IE
=352.99 (8" S)
IE
=362.99 (8" W)
CB 08
CB TYPE 1
RIM = 853.49-
N 186925.91
IE=349.29-(8"
SW)
E 1306875.15
LEGEND:
■ STORM CATCH BASIN
Q■ STORM MANHOLE
® DETENTION TANK ACCESS RISER
GRADE BREAK
D STORM LINE
PERFORATED PIPE STORM LINE
DETENTION TANK 1 2
C3.4 C3.4
XXX CONTOUR LINE
PROPERTY/RIGHT-OF-WAY LINE
FLOW DIRECTION
n ADS N-12 S-P, 4" CAP
N GRAPHIC SCALE
0 10 20 40
I=i mmllll -
1" = 20 FEET
Pipe Table
PIPE NAME
SIZE (in)
UPPER
INVERT
ELEVATION
SLOPE
P - 116
4
354.12
0.95%
P - 117
4
353.90
0.84%
P - 118
4
353.63
0.70%
P - 119
4
353.50
0.69%
P - 120
4
353.49
0.78%
P - 121
4
353.09
0.59%
P - 122
4
352.97
0.50%
P - 123
4
352.98
0.50%
P - 124
4
353.00
0.50%
P - 125
4
353.01
0.50%
P - 128
8
354.51
1.24%
P - 129
8
352.00
2.94%
P - 133
8
352.38
0.50%
P - 137
8
350.08
1.22%
P - 138
8
349.95
2.15%
P - 139
36
345.00
0.00%
P - 169
8
350.50
1.14%
RIM = 354.21
IE = 349.89 (8" E)
IE = 349.89 (8" SW)
IE = 349.89 (8" W)
RIM = 354.35
IE = 344.89 (36" SW)
IE = 347.73 (8" NE)
IE =
351.94 (8" SE)
IE =
352.09 (4" SE)
IE =
352.09 (4" SW)
IE
= 351.94 (8" S)
IE =
351.94 (8" W)
RIM = 353.20
IE
= 350.85 (8" SW)
CONSTRUCTION RECORD DRAWINGS
SURVEYED:
DESIGNED:
STORM DRAINAGE REVISIONS AMT 09/20/2019 ACB DRAwN. AMT
ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS AMT 01 28 2019 ACB CHECKED:
Bis
REVISION BY DATE APPR APPROVED:
WJF
SCALE:
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE IN
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL NAD 1983/1991
DATU M
� � L
\\\\ \\\\\ \
CITY OF
1;R] RENTON
NUF
Planning/Building/Public Works Dept.
KEYNOTES:
OWITH
TYPE 1 CATCH BASIN
HERRINGBONE
1
2
O
GRATE
C3.5
C3.6
TYPE 1 CATCH BASIN
1
1
O
WITH SOLID COVER
C3.5
C3.6
O
TYPE 2 CATCH BASIN
2
2
O3
WITH HERRINGBONE
C3.5
C3.6
O
GRATE
O
TYPE 2 CATCH BASIN
WITH ROUND SOLID LID
2
3
C3.5
C3.6
10
FLOW CONTROL
1
O5
MANHOLE
C3.8
11
COLLECTOR DRAIN
2
OCLEANOUT
C3.9
4" PERFORATED 3
UNDERDRAIN, TYP. C3.9
8" COLLECTOR DRAIN 4
C3.9
CONNECTION TO
COLLECTOR 1
DRAIN, TYP. C3.9
DETENTION TANK 4
ACCESS RISER, TYP. C3.8
CONVEYANCE PIPE
O
Lo
O
00
�
u
NOTES:
1. SEE SHEETS C3.5 FOR GENERAL STORM DRAINAGE NOTES.
2. CONTRACTOR SHALL FIELD VERIFY EXISTING INVERT
ELEVATION PRIOR TO CONSTRUCTION WHERE NOTED.
3. UNDERDRAIN LINES SHALL BE ADS N-12 S-P AND ARE
DESIGNED TO MAINTAIN A MINIMUM 18" DEPTH FROM FINISH
GRADE.
4. ALL CONVEYANCE PIPE SHALL BE PVC. MINIMUM REQUIRED
O
COVER FOR PVC PIPE IS 3 FEET.
OO
5. ALL COLLECTOR PIPE SHALL BE ADS N-12 S-P.
00
6. ALL DETENTION TANK SHALL BE ALUMINIZED TYPE 2, MEETING
SECTION 5.1.2 OF THE CITY OF RENTON SURFACE WATER
DESIGN MANUAL.
7. PROVIDE CDF ABOVE THE EXISTING WATERLINE PER DETAIL 6
ON SHEET C3.9.
ALL PROPOSED PIPE SHOWN ON THIS
SHEET WILL BE PRIVATE
z
O
Q
GRAPHIC SCALE
O
0 10 20 40
z
w
1" = 20 FEET
vJ
0
w
LL
J
R-40281 1
_jO
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
U
cn
LLJ
J
0
0
2
McKNIGHT MIDDLE SCHOOL
DA1/15/2019
~
=
FIELD IMPROVEMENTS
FlELDBOOK:
RENTON SCHOOL DISTRICT
PAGE
-
DRAVANG NO:
z
C3.1
DRAINAGE PLAN
SHEET:1 1 OF.
z
O
Q
O
z
LU
0
J
W_
LL
a
J
n
J
O
O
CU
LU
J
0
C0
G
2
0
z
CU
G
0
LO
0
ao
N
W
zz
w
L
MATCHLINE SHEET C3.3
55, 6 LF tB
P - 5,6 IiFB P-59,2LF
P - 67, 31 LF
CB 17 P - 60, 2 LF P - 60, 2 LF
8
r
. .� 1 uIN AVE NE
0 10 20 40
Z
1" = 20 FEET
D
STORM LINE
LEGEND:
PERFORATED PIPE STORM LINE
NOTES:
LARGE DIAMETER DETENTION PIPE
■
STORM CATCH BASIN
1. SEE SHEETS NERALS RM DRAINAGE
XXX
CONTOUR LINE
NOTES.
■Q
STORM MANHOLE
- -
PROPERTY/RIGHT-OF-WAY LINE
2. CONTRACTORVERIFY EXISTING INVERT
>TONSTRUCTION
•
STORM DRAINAGE CLEANOUT
FLOW DIRECTION
ELEVATION PWHERE NOTED!
®
DETENTION TANK ACCESS RISER3.
- - - - GB
GRADE BREAK CONSTRUCTION
RECORD
DRAWINGS
UNDERDRAINESIGNED TO MAINTAIN A
- 8" DEPTH FROM FINISH GRADE. ■ /�
Know what's below
Call before ou dig. AHBL PROJECT NO.2180059
1
gor -
ALTERATION OF THIS DOO NIENT SHALL INVALIDATE THE a)_Hj B L
PROFESSIONAL SEAL AND SIGNATURE. PUBLICATION OF
THIS DOCUMENT DOES NOT DEROGATE FROM RESERVED
001101 TIP MM N IT. THIS DOCLNENT IS FOR USE TACO M A • SEATTLE • SPOKANE • TRI-CITIES 1
ONLY FOR THE PROJECT IDENTIFIED N THE TITLE BLOCK
AND IS NOT TO BE USED FOR REPAIR, REMODEL OR
ADDITION TO THAT PROJECT OR FOR ANY OTHER PROJECT. 1200 6th Avenue, Suite 1620 Seattle, WA 98101 NO.
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB
W
STORM STRUCTURE TABLE
STRUCTURE NAME
STRUCTURE DETAILS
CB 16
RIM = 349.28
48" TYPE 2 CB
IE
= 342.75 (36" S)
N 186541.78
IE
= 347.04 (8" E)
E 1306691.12
IE
= 347.04 (8" N)
CB 17
RIM = 348.46
60" TYPE 2 CB
IE
= 342.75 (8" S)
N 186506.05
IE
= 342.75 (36" N)
E 1306690.71
CB 18
RIM = 348.55
48" TYPE 2 CB
IE
= 342.58 (8" N)
N 186480.85
IE
= 342.58 (8" W)
E 1306684.88
Pipe Table
Pipe Name
UPPER pipe Slope
INVERT ELEV
352.86 1.66°
P - 2
P - 3
352.95
1.66%
P - 4
35 4
1.66%
P - 5
353.13
1.66%
P -
353.23
1.66%
P - 7
352.92
1.66%
P - 8
352.65
1.66%
P - 9
352.38
1.66%
P - 10
352.10
1.66%
P - 11
351.83
1.66%
P - 12
351.56
1.66%
P - 13
351.29
1.66%
P - 14
351.01
1.66%
P - 15
350.74
1.66%
P - 16
350.47
1.66%
P - 17
350.20
1.66%
P - 18
349.93
1.66%
P - 19
349.65
1.66%
P - 20
349.38
1.66%
P - 21
349.11
1.66%
P - 22
348.84
1.66%
P - 23 348.57
1.66%
KEYNOTES:
OTYPE 1 CATCH BASIN WITH
\\\\ \\\\\ \
P
j N\\\
jX% \�
N\
C3.3
KEYMAP
HERRINGBONE GRATE
O
TYPE 1 CATCH BASIN WITH
SOLID COVER
O
TYPE 2 CATCH BASIN WITH
HERRINGBONE GRATE
O
TYPE 2 CATCH BASIN WITH
ROUND SOLID LID
OFLOW
CONTROL MANHOLE
SURVEYED: SCALE:
VERTICALHORIZONTAL: NAD 19B13/1991
DESIGNED: AS SHOWN CITY OF
1;R) RENTON
STORM DRAINAGE REVISIONS AMT 09/20/2019 ACB DRAwN. AMT
ONE INCH DATUM NUF
ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS AMT 01 28 2019 ACB CH AT AT FULL SCALE Planning/Building/Public Works Dept.
IF NOT ONE INCH
REVISION BY DATE A P P R APPROVED: SCALE ACCORDINGLY
WJF
I
STORM STRUCTURE TABLE
STRUCTURE NAME
STRUCTURE DETAILS
CB 19
RIM = 347.40
48" TYPE 2 CB
IE = 342.19 (8" E)
N 186482.97
IE = 342.19 (12" W)
E 1306623.17
IE = 342.19 (8" N)
RIM = 346.93
CB 20
48" TYPE 2 CB
IE = 342.19 (12"
N 186484.27
IE = 342.19 " W)
E 1306506.65
CB 21
IM = 349.30
48" TYPE 2 CB
E = 342.75 (36" W)
N 186535.73
IE = 346.96 (8 , NE)
E 1306887.
z
Pipe Table
Pipe Name
P - 24
UPPER
INVERT ELEV
pipe Slope
1.66%
348.29
348.29
P - 25
1.66%
P - 26
348.57
1.66%
P - 27
348.84
1.66%
P - 28
349.11
1.66%
P - 29
349.38
1.66%
P - 30
349.65
1.66%
P - 31
349.93
350.20
1.66%
P - 32
1.66%
P - 33
350.47
1.66%
P - 34
350.74
1.66%
P - 35
351.01
1.66%
P - 36
351.29
1.66%
P - 37
351.56
1.66%
P - 38
351.83
352.10
1.66%
P - 39
1.66%
P - 40
352.38
1.66%
P - 41
352.65
1.66%
P - 42
352.92
1.66%
P - 43
353.23
1.66%
P - 44
353.13
1.66%
1 1.66%
P - 45
353.04
STORM STRUCTURE TABLE
STRUCTURE NAM
STRUCTURE DETAIL
CB
RIM = 349.30
CB PE 1
IE =
347.04 (8" SW)
86541.61
IE
= 347.04 (8" W)
E 1306890.95
IE
= 347.04 (8" N)
CS
RIM = 344.00
EXISTING TYPE 2 CB
IE
= 340.45 (8" NE)
N 186540.91
IE =
340.45 (8" SW)
E 1306309.37
IE
= -4.67 (12" N)
STCB #636
RIM = 343.40
EXISTING TYPE 1 CB
IE
= 340.46 (12" E)
N 186549.44
IE =
340.46 (8" SW)
E 1306318.27
Pipe Table
Pipe Name UPPER
INVERT ELEV
P - 46 352.95
pipe Slope
1.66%
P - 47
352.86
1.66% I
P - 48
352.76
1.66% I
P - 49
352.07
1.75% I
P - 50
347.49
0.63%
P - 51
347.49
0.63%
P - 52
352.07
1.75%
P - 53
347.04
1.17%
P - 54
342.75
0.66%
P - 55
342.58
0.63%
P - 56
342.19
0.00%
P - 57
342.19
0.87%
P - 58
352.76
1.66%
P - 59
342.75
0.00%
P - 60
342.75
0.00%
P - 61
342.25
0.00%
P - 62
342.25
0.00%
P - 63
342.25
0.00%
P - 64
342.25
0.00%
P - 65
342.75
0.00%
P - 66
342.25
0.00%
P - 67 342.25
0.00%
O COLLECTOR DRAIN
CLEANOUT C3.9
O 4" PERFORATED 3
UNDERDRAIN, TYP. C3.9
O 8" PERFORATED 4
COLLECTOR DRAIN C3.9
CONNECTION TO
OCOLLECTOR 1
DRAIN, TYP. C3.9
O
N
O
O
00
T
67 u
co
O
O
O
i
00
10 DETENTION PIPE ACCESS 4 z
RISER, TYP. C3 8 0
Q
O
z
LU
0
W
LL
Q
0-
R-395905 O
MPLIANCE WITH CITY OF RENTON STANDARDS O
U
LU
C0
G
McKNIGHT MIDDLE SCH DA1/15/2019 ~
FIELD IMPROVEMENTS =
FlELDBOOK:
RENTON SCHOOL DISTRICT PAGE -
DRAWING NO: z
DRAINAGE PLAN C3.2 0
HEET:10 "32 2
00
N
w
P(
oo
z
O_
Q
>
O
z
w
rr
0
w_
L.L
a
J
n
J
O
O
U
w
J
C0
G
CD
z
CU
G
to
0
N
Iil
zz
w
0
•
•
STCB#636 TYPE 1
RIM:343.40
8" CPP SE IE:340.40
PP SW IE:340.46
N.18 49.37
E:1,306, 8.35
/ / O
/ 199 LF
/ I 12" PVC
@0.87%
/ I (P - 57)
1
/ O ,
CD
0
O
1
I
1
O
I
I
I
I
CD
I
I
I
1
0
I
I
1
I
I
CB 20
48" T)
RIM:
IE: 34:
IE: 34:
CB 1'
RIM: 47.40
IE: 34 .19 8" (E)
IE: 34 .19 12" (W)
Ix I IE: 34 .19 8" (N)
m1/ P-71,5LIj 11
O
MATCHLINE S T C3.2
Know at's below.
all before you dig. AHBL PROJECT NO.2180059
350
345
340
336
A
/
Pipe Table
Pipe Name UPPER pipe Slope
INVERT ELEV
P - 2 352.86 1.66%
P - 3
352.95
1.66%
P - 4
353.04
1.66%
P - 5
353.13
1.66%
P - 6
353.23
1.66%
P - 7
P - 8
P - 9
352.92
1.66%
352.65
1.66%
352.38
1.66%
P - 10
352.10
1.66%
P - 11
351.83
1.66%
P - 12
351.56
1.66%
P - 13
351.29
1.66%
P - 14
351.01
1.66%
P - 15
- 16
P - 17
350.74
1.66%
350.47
1.66%
350.20
1.66%
P - 18
49.93
1.66%
P - 19
349.6
1.66%
P - 20
349.38
66%
P - 21
349.11
1.66%
P - 22
348.84
1.66%
P - 23
348.57
1.66%
XISTING TYPE 1 CB #636
-1,306,318.35
IM: 343.40
IN: 340 (12"E) PROPO
rQLLL340.4 "
Ln 117 CC)
C
It
1`0 co I) M
STORM
0+50
Pipe Table
Pipe Name UPPER
INVERT ELEV
P - 24 348.29
pipe Slope
1.66%
P - 25
348.29
1.66%
P - 26
348.57
1.66%
P - 27
348.84
1.66%
P - 28
349.11
1.66%
P - 29
349.38
1.66%
P - 30
349.65
1.66%
P - 31
349.93
1.66%
P - 32
350.20
1.66%
P - 33
350.47
1.66%
P - 34
350.74
1.66%
P - 35
351.01
1.66%
P - 36
351.29
1.66%
P - 37
351.56
1.66%
P - 38
351.83
1.66%
P - 39
352.10
1.66%
P - 40
352.38
1.66%
P - 41
352.65
1.66%
P - 42
352.92
1.66%
P - 43
353.23
1.66%
P - 44
353.13
1.66%
45
353.04
1.66%
PROPOSED ELEVATION
cr PIPE CENTERLINE -
EXISTING ELEVATION
@a PIP NTERLIN
n M O O
Ln Lf) ( -
� CM
1+00
INAGE PROFILE 1
ALTERATION OF THIS DMENT SHALL INVALDATE THE
PROFESSIONAL SEAL AND SIGNATURE PUBLICATION OF
THIS DOCUMENT DOES NOT DEROGATE FROM RESERVED
OIUERSIIP RK;M N IT. THIS DOCUMENT IS FOR USE T A C O M A • SEATTLE • SPOKANE TRI-CITIES 1
ONLY FOR THE PRO,ECT DENWED N THE MU BLOCK
AND IS NOT TO BE USED FOR REPAIl REMODEL OR
ADDITION TO THAT PMECT OR FOR ANY OTHER PROJ7. 1200 6th Avenue, Suite 1620 Seattle, WA 98101 NO.
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB
199 LF 12" @ 0
Pipe Table
Pipe Name UPPER pipe Slope
INVERT ELEV
P - 46 352.95 1.66%
P - 47 352.86 1.66%
P - 48
352.76
1.66%
P - 49
352.07
1.75%
P - 50
347.49
0.63%
P - 51
347.49
0.63%
P - 52
352.07
1.75%
P - 53
347.04
1.17%
P - 54
342.75
0.66%
P - 55
P - 56
342.58
0.63%
342.19
0.00%
P - 57
342.19
0.87%
P - 58
352.76
1.66%
P - 59
342.75
0.00%
P - 60
342.75
0.00%
P - 61
342.25
0.00%
P - 62
P - 63
342.25
0.00%
342.25
0.00%
P - 64
342.25
0.00%
P - 65
342.75
0.00%
P - 66
342.25
0.00%
P - 67
342.25
0.00%
n4
GRAPHIC SCALE
0 10 20 40
1" = 20 FEET
CB 20, 48" TYPE 2 CB
N: 186484.27
E: 1306506.65
RIM: 346.93
I .
I OUT: 342.19 (12"VI)
117 LF 12"
CONI
KEYNOTES:
O
TYPE 1 CATCH BASIN WITH
HERRINGBONE GRATE
C
O
TYPE 1 CATCH BASIN WITH
SOLID COVER
O
TYPE 2 CATCH BASIN WITH
HERRINGBONE GRATE
OTYPE
2 CATCH BASIN WITH
I
ROUND SOLID LID
FLOW CONTROL MANHOLE
OCOLLECTOR
DRAIN CLEANOUT
CB 19, 48" TYPE 2 CB
N: 186482.97
E: 1306623.17
RIM: 347.40
IE IN: 342.19 (8"E)
IE IN: 342.19 (8"N)
IE OU :
� It r-
F7 L7 � r- Ip w O 00 Ln F7O UM-) F7 Io �7,
CO CO ON Ln
M M M M C, oM I) M � � co
1+50 2+00 2+50 3+50 4+00
14 \\
j�\�\
X NN
ii �N
// N\�
14 �N
N
C3.3
CONSTRUCTION RECORD DRAWINGS
SURVEYED: SCALE:
HORIZONTAL: NAD 1983/1991
DESIGNED: AS SHOWN
STORM DRAINAGE REVISIONS AMT 09/20/2019 ACB DRAwN. AMT
ONE INCH DATU M
ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS AMT 01 28 2019 ACB CHECKED: AT FULL SCALE
BJS IF NOT ONE INCH
REVISION BY DATE A P P R APPROVED: SCALE ACCORDINGLY
WJF
KEYMAP
caRi CITY OF
RENTON
NUF
Planning/Building/Public Works Dept.
U.
26 LF
8" @
0.66%
LEGEND:
■
STORMrCABASIN
LE
•M
DRAINAGE CLEANOUT
®NTION
ZBGRAD
TANK ACCESS RISER
- - -
E BREAK
M LINE
PERFORATED PIPE STORM LINE
LARGE DIAMETER DETENTION PIPE
XXX
CONTOUR LINE
-
PROPERTY/RIGHT-OF-WAY LINE
NOTE:
1. SEE SHEETS C3.5 FOR GENERAL STORM DRAINAGE NOTES
2. CONTRACTOR SHALL FIELD VERIFY EXISTING INVERT
ELEVATION PRIOR TO CONSTRUCTION WHERE NOTED.
2LF36"
7, 60" TYPE 2 C�
RIM: 348.46
IE: 342.75 8" (S)
2.75 36" (N)
N: 186506.05
E: 1306690.71
1`0 M r-
06
F 7 co M co
CB 16, 48" TYPE 2 CB
N: 186541.78
E: 1306691.12
RIM: 349.28
IE IN: 347.04 (8"E)
IE IN: 347.04 (8"N)
IE OUT: 342.75 (36"S)
350
-31 LF 48" @ 0.00%
345
2 LF 36" @ 0.00%
340
336
O
N
O
00
T
67 u
O
O
O
4+50 z
O
Q
>
O
z
w
0
w
LL
J
R-395907 O
IN COMPLI CE WITH CITY OF RENTON STANDARDS
2
U
cn
w
J
0
McKNIGHT MIDDLE SCHOOL DATE: 2019 ~
FIELD IMPROVEMENTS =
FlELDBOOK:
RENTON SCHOOL DISTRICT PAGE -
DRAVANG NO: z
3 •
DRAINAGE PLAN SHEET:GF:
11 32
O
N
LO
O
O
00
T
Iql-
O
O
O
M
W
cry,
n
Z
O
O
Z
W
rY
VJ
J
W
H
Q
J
n
J
O
O
U
w
J
r)
0
Z
U
00
N
O
I
O
1
0
w
I-
z
O
I-
O
z
/W
v /
I�
J
W
H
a
n
J
O
O
2
VJ
W
J
0
5
G
z
U
a
01
0
_m
N
LJ
a
z
Ld
USE ADA COMPLIANT
GRATES IN ALL
WALKWAYS
2t
6" OR 12"
ONE #3 BAR HOOP FOR 6" HEIGHT
TWO #3 BAR HOOPS FOR 12" HEIGHT
RECTANGULAR ADJUSTMENT SECTION
#3 BAR EACH CORNER
#3 BAR EACH SIDE
#3 BAR EACH WAY
#3 BAR EACH CORNEF
18" MIN
#3 BAR HOOP
15��N0 46r�e�
'v
v
PRECAST BASE SECTION
SEE NOTE 1
ALTERNATIVE PRECAST BASE SECTION
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCEDOR
12"
PLAIN CONCRETE
ALL METAL PIPE
15"
CPSSP*
12"
(STD. SPEC. 9-05.20)
SOLID WALL PVC
15"
(STD. SPEC. 9-05.12(1))
PROFILE WALL PVC
15"
(STD. SPEC. 9-05.12(2))
* CORRUGATED POLYETHYLENE
STORM SEWER PIPE
NOTES
1. As acceptable alternatives to the rebar shown in the PRECAST BASE
SECTION, fibers (placed according to the Standard Specifications), or
wire mesh having a minimum area of 0.12 square inches per foot shall
be used with the minimum required rebar shown in the ALTERNATIVE
PRECAST BASE SECTION. Win: mesh shall not be placed in the
knockouts.
2. The knockout diameter shall not be greater than 20". Knockouts shall
have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5"
minimum gap between the knockout wall and the outside of the pipe.
After the pipe is installed, fill the gap with joint mortar in accordance
with Standard Specification 9-04.3.
3. The maximum depth from the finished grade to the lowest pipe invert
shall be 5'.
4. The frame and grate must be installed with the Flange down.
5. The Precast Base Section may have a rounded floor, and the walls may
be sloped at a rate of 1:24 or steeper.
6. The opening shall be measured at the top of the precast base section.
7. All pickup holes shall be grouted full after the basin has been placed.
8. All grade rings and castings shall be set in mortar in accordance with
Standard Specification 9-04.3.
PUBLIC WORKS CATCH BASIN TYPE 7 STD. PLAN - 200,00
DEPARTMENT
ANT MARCH 2O08
CATCH BASIN TYPE 1
NOT TO SCALE
CATCH BASIN FRAME AND VANES GRATE (DETAIL 204.00)
HANDHOLD
S RECTANGULAR ADJUSTMENT SECTION
OR CIRCULAR ADJUSTMENT SECTION
o 'v
GROUT, TYPICAL (SEE NOTE 5)
_ .. FLAT SLAB TOP
48', 64', 60', 72", 84- OR W
/-- MORTAR (TYP.)
STEPS OR
LADDER
FILLET REINFORCING STEEL ITYP.)
N GRAVEL BACKF LL FOR
PIPE ZONE BEDDING
SEPARATE BASE INTEGRALBASE
CAST -IN -PLACE PRECAST WITH RISER
"O' RING
Igo
GRAVEL BED FOR
8"= PIPE ZONEE BEDDING
SEPARATE BASE
PRECAST
CATCH BASIN DIMENSIONS
BASCATCH
DIAMEITER
WALL
THICKNESS
BASE
THICKNESS
MAXIMUM
KNCSCZE UT
MINIMUM
DISTANCE
BETWEEN
KNOCKOUTS
BASE REINFORCING STEEL
in2/N. IN EACH DIRECTION
SEPARATE BASE
INTEGRAL BASE
48"
4"
W
36"
8"
0.23
0.15
54"
4.5"
8"
42"
8"
0.19
0.19
60"
5"
8"
48'
8"
0.25
0.25
72"
6"
8"
60"
12"
0.35
0.24
84"
8"
12"
72"
IT
0.39
0.29
96"
8"
12"
84"
IT
0.39
0.29
NOTES
1- No steps are required when height is 4' or less.
2. The bottom of the precast catch basin may be sloped to facilitate cleaning.
3. The rectangular frame and grate must be installed with the flange down.
The frame may be cast into the adjustment section.
4. Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide
a 1.5" minimum gap between the knockout wall and the outside of the pipe. After
the pipe is installed, fill the gap with joint mortar in accordance With Standard
Specification 9-04.3.
5. All grade rings, risers, and castings shall be set in mortar in accordance with
Standard Specification 9-04.3.
PIPE ALLOWANCES
CATCH
PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER
BASIN
DIAMETER
CONCRETE
ALL
METAL
CPSSP
tD
SOLID
WALL
PVC D
PROFILE
WALL
PVC Q9
48"
24"
30"
24"
27"
30"
5C
30"
36"
30"
27"
36"
60"
36"
42'
36"
36"
42"
72"
42"
54"
42'
36"
48"
84"
54"
60"
54"
36"
48"
96"
60"
72"
60"
36"
48"
(D Corrugated Polyethylene Storm Sewer Pipe (Std. Spec. 9-05.20)
Q (Std. Spec. 9-05.12(1))
(g) (Std. Spec. 9-05.12(2))
ti`t'Y o PUBLIC WORKS CATCH BASIN TYPE 2
STD. PLAN - 201.00
DEPARTMENT yiARCI= 2008
�1V't
CATCH BASIN TYPE 2
NOT TO SCALE
SURFACE WATER STANDARD PLAN NOTES AND CONSTRUCTION SEQUENCE
1. THESE NOTES SHALL APPEAR ON PROJECTS FOR THE SURFACE WATER UTILITY.
2. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING MUST BE HELD
BETWEEN THE CITY OF RENTON PLAN REVIEW SECTION AND THE APPLICANT.
3. ALL DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE RENTON MUNICIPAL CODE (RMC), THE LATEST EDITION
OF THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE
AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. IT
SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE PROFESSIONAL CIVIL ENGINEER TO CORRECT ANY ERROR,
OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THIS PLANS. ALL CORRECTIONS SHALL BE AT NO
ADDITIONAL COST TO THE CITY.
4. APPROVAL OF THIS ROAD, GRADING, PARKING AND DRAINAGE PLAN DOES NOT CONSTITUTE AN APPROVAL OF ANY OTHER
CONSTRUCTION (E.G. DOMESTIC WATER CONVEYANCE, SEWER CONVEYANCE, GAS, ELECTRICAL. ETC.)THE SURFACE WATER
DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS, WHICH ARE ON FILE IN WITH THE CITY.
ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON PUBLIC WORKS
DEPARTMENT, SURFACE WATER UTILITY SECTION.
5. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
6. GRADING ACTIVITIES (SITE ALTERATION) ARE LIMITED TO THE HOURS OF 7 A.M. TO 7 P.M. MONDAY THROUGH SATURDAY AND
NO WORK ON SUNDAY IS ALLOWED, UNLESS OTHERWISE APPROVED WITH A WRITTEN DECISION BY THE CITY OF RENTON.
7. IT SHALL BE THE APPLICANT'S/CONTRACTOR'S RESPONSIBILITY TO OBTAIN ALL CONSTRUCTION EASEMENTS NECESSARY
BEFORE INITIATING OFF -SITE WORK. EASEMENTS REQUIRE CITY REVIEW AND APPROVAL PRIOR TO CONSTRUCTION.
8. FRANCHISED UTILITIES OR OTHER INSTALLATIONS THAT ARE NOT SHOWN ON THESE APPROVED PLANS SHALL NOT BE
CONSTRUCTED UNLESS AN APPROVED SET OF PLANS THAT MEET ALL REQUIREMENTS OF CHAPTER 4 OF THE SURFACE
WATER DESIGN MANUAL ARE SUBMITTED TO THE CITY OF RENTON.
9. DATUM SHALL BE NAVD 88 UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON. REFERENCE BENCHMARK AND
ELEVATIONS ARE NOTED ON THE PLANS.
10. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES MUST BE SUBMITTED TO THE
CITY FOR REVIEW AND APPROVAL.
11. ALL UTILITY TRENCHES AND ROADWAY SUBGRADE SHALL BE BACKFILLED AND COMPACTED TO 95 PERCENT DENSITY,
STANDARD PROCTOR.
12. OPEN CUTTING OF EXISTING ROADWAYS FOR NON -FRANCHISED J "
UTILITY OR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS tiyti�� of wAsgj���'�
SPECIFICALLY APPROVED BY THE CITY OF RENTON AND NOTED ON y� ��
THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN
ACCORDANCE WITH THE CITY OF RENTON TRENCH RESTORATION ,
STANDARDS.
AS -BUILT
�° =
o��SSIONALgE���
I CERTIFY THAT THE INFORMATION SHOWN HEREON
WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE
1/07/2019
O
LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND
AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING
- -
MID130
FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY
ALM?ATDN OF THIS DMENT SHALL I WXMTE THE
NALSEAL AND SIGNATURE. PUBMIna+OF
Know what's belOW.
DIRECT SUPERVISION ON THIS DATE: 11/7/2019.
THIS DOI 111M DOES NOT OEROGAIE FM RESERVED
OOERSHP WM N ff. THS D00.11111317 �
TAC0MA•SEATTLE•SPOKANE-TRI-CITIES
Call before you dig.
AHBL PROJECT NO.2180059
ONLY FOR THE PKM MIFED IN THE AND IS NOT TO BE USED FOR REPAR" FBIl00EL OR
ADDITION To THAT PRQECT OR FOR ANY mHER PROiCT
1200 6th Avenue, Suite 1620 Seattle, WA 98101
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB
CLEAN SURFACE AND BOTTOM AREA.
PROVIDE UNIFORM CONTACT.
THE SURFACE AREA OF THE BASE SECTION MUST
BE GROUTED TO THE BOTTOM AREA OF THE
ADJUSTMENT SECTION.
BASE SECTION
SE ADA COMPLIANT
;RATES IN ALL WALKWAYS
SEE NOTE 4
NOTES
1. THE COVER OR GRATING OF A CATCH BASIN SHALL NOT BE GROUTED TO FINAL GRADE UNTIL THE FINAL ELEVATION OF THE PAVEMENT,
GUTTER, DITCH, OR SIDEWALK IN WHICH IT 15 TO BE PLACED HAS BEEN ESTABLISHED, AND UNTIL PERMISSION THEREAFTER IS GIVEN BY
THE ENGINEER TO GROUT IN PLACE IN ACCORDANCE WITH APWA STANDARD SPECIFICATION 7-05.3.
2. SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE. THE USE OF SHIMS IS PROHIBITED.
3. A CONTINUOUS LAYER OF MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMENT,
4. THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A RUNNING BOND OR Y2 BOND.
5. ADJUSTMENT SECTION SHALL BE GROUTED WATERTIGHT TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION WITH NONSfIRINK GROUT
6. GROUTING BETWEEN ADJUSTMENT SECTION SHALL BE WATER TIGHT.
7. GROUT IS TO BE NON -SHRINK TYPE GROUT MEETING THE REQUIREMENTS OF ASTM 151 PER APWA STANDARD SPECIFICATION 9-20.3 FOR
MAXIMUM PERCENT DRY SHRINKAGE. THE MINIMUM COMPRESSIVE STRENGTH SHALL BE 4,000 PSI AT 7 DAY PER APWA STANDARD
SPECIFICATION 9-20.3
8. PICK / LIFTING HOLES ARE TO BE GROUTED WATER TIGHT.
PUBLIC WORKS CATCH BASIN INSTALLATION STD. PLAN 202,00
DEPARTMENT
-- _. - MARCH 2O08
CATCH BASIN INSTALLATION
NOT TO SCALE
13. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND
THEY MUST BE SATISFACTORILY MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON -SITE
EROSION HAS PASSED.
14. ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL
CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY
SECTION.
15. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE
CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE
NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND
COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE
SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS "C", WITH THE
EXCEPTION OF PVC PIPE.
16. STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT #1 OR BETTER INSIDE AND OUTSIDE.
17. ALL DRAINAGE STRUCTURES, SUCH AS CATCH BASINS AND MANHOLES SHALL HAVE LOCKING LIDS. ALL DRAINAGE
STRUCTURES ASSOCIATED WITH A PERMANENT RETENTION/DETENTION FACILITY SHALL HAVE SOLID LOCKING LIDS.
18. BUILDING AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 EASEMENT WIDTHS AND BUILDING
SETBACKS LINES.
19. ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL.
20. ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY OF RENTON RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A
MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. ROCK FOR EROSION PROTECTION OF
ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF ONE (1) FOOT AND MUST
MEET THE FOLLOWING SPECIFICATIONS:
4 - 8 INCH ROCK / 40 - 70% PASSING;
2 - 4 INCH ROCK / 30 - 40% PASSING; AND
LESS THAN 2 INCH ROCK / 10 - 20% PASSING.
21. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS
APPROVED BY THE CITY PLAN REVIEWER OR SURFACE WATER UTILITY SECTION. AN ACCURATELY DIMENSIONED, CERTIFIED
AS -BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY UPON COMPLETION.
22. DRAINAGE OUTLETS (STUB -OUTS) SHALL BE PROVIDED FOR EACH INDIVIDUAL LOT, EXCEPT FOR THOSE LOTS APPROVED FOR
INFILTRATION BY THE CITY. STUB -OUTS SHALL CONFORM TO THE FOLLOWING:
a. EACH OUTLET SHALL BE SUITABLY LOCATED AT THE LOWEST ELEVATION ON THE LOT, SO AS TO SERVICE ALL FUTURE
ROOF DOWNSPOUTS AND FOOTING DRAINS, DRIVEWAYS, YARD DRAINS, AND ANY OTHER SURFACE OR SUBSURFACE
CONSTRUCTION RECORD DRAWINGS
TO AN APPROVED OUTFALL LOCATION.
STORM DRAINAGE REVISIONS
1 ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS
NO. REVISION
SURVEYED:
DESIGNED:
AMT 09/20/2019 ACB ORAwN. AMT
AMT 01 28 2019 ACB CHECKEDBJS
BY DATE APPR APPRovED:
WJF
SCALE:
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
19
HOR ON ALL" NAD NAVD1983//11991
DATUM
I
BOLT -DOWN HOLE (TYP.)
- 5/8" - 11 NC, SEE
DETAIL & NOTE 2
O
TOP
SECTION O
RECESSED ALLEN
HEAD CAP SCREW
7L /8"_t 1/8" 518" - 11 NC x 2"
3/4" GRATE
P/z
1 518" FRAME
2 1/2"
SECTION
BOLT -DOWN DETAIL
DETAIL O SEE NOTE
NOTES
1 This frame is designed to accommodate 20" x 24" grates or
covers
2. Provide two holes in the frame that are vertically aligned with t
he grate or cover slots. Tap each hole to accept
a 5/8" - 11 NC x 2" allen head cap screw.
Location of bolt down holes varies among different
manufacturers.
3- Refer to Standard Specification 9-05.15(2) for additional
requirements.
ISOMETRIC VIEW
'SY
PUBLIC WORKS RECTANGULAR FRAME STD. PLAN -- 204.00
\= / DEPARTMENT
FNT' MARCH 2O08
RECTANGULAR FRAME
NOT TO SCALE
DRAINS NECESSARY TO RENDER THE LOTS SUITABLE FOR THEIR INTENDED USE. EACH OUTLET SHALL HAVE
FREE -FLOWING, POSITIVE DRAINAGE TO AN APPROVED STORMWATER CONVEYANCE SYSTEM OR
b. OUTLETS ON EACH LOT SHALL BE LOCATED WITH A FIVE -FOOT -HIGH, 2" X 4" STAKE MARKED "STORM" OR "DRAIN". THE
STUB -OUT SHALL EXTEND ABOVE SURFACE LEVEL, BE VISIBLE, AND BE SECURED TO THE STAKE.
C. PIPE MATERIAL SHALL CONFORM TO UNDERDRAIN SPECIFICATIONS DESCRIBED IN CHAPTER 4 OF THE SURFACE WATER
DESIGN MANUAL AND, IF NON-METALLIC, THE PIPE SHALL BE PLACED IN A TRENCH WITH A TRACING WIRE ABOVE OR
OTHER ACCEPTABLE DETECTION.
d. PRIVATE DRAINAGE EASEMENTS ARE REQUIRED FOR DRAINAGE SYSTEMS DESIGNED TO CONVEY FLOWS THROUGH
INDIVIDUAL LOTS.
L_J
C)
CD
C6
e.
THE APPLICANT/CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE LOCATIONS OF ALL STUB -OUT CONVEYANCE
z
LINES WITH RESPECT TO OTHER UTILITIES (E.G. POWER, GAS, TELEPHONE, TELEVISION).
O
f.
ALL INDIVIDUAL STUB -OUTS SHALL BE PRIVATELY OWNED AND MAINTAINED BY THE LOT HOME OWNER.
g.
STORM DRAINAGE PIPE SYSTEMS SHALL NOT PENETRATE BUILDING FOUNDATIONS, EXCEPT FOR SUMP PUMP DISCHARGE
LINES USED TO DRAIN CRAWL SPACES, PROVIDED THE SUMP PUMP SYSTEM INCLUDES BACKFLOW PREVENTION OR A
Q
CHECK VALVE.
>
O
23.
ALL DISTURBED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE MUST
z
DEMONSTRATE ONE OF THE FOLLOWING: THE EXISTING DUFF LAYER SHALL BE STAGED AND REDISTRIBUTED TO MAINTAIN
w
THE MOISTURE CAPACITY OF THE SOIL, OR; AMENDED SOIL SHALL BE ADDED TO MAINTAIN THE MOISTURE CAPACITY.
24.
PROOF OF LIABILITY INSURANCE SHALL BE SUBMITTED TO THE CITY PRIOR TO CONSTRUCTION PERMIT ISSUANCE.
U)
0
25.
ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE
J
CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER, THE
w
CITY OF RENTON DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM
PROVIDED DURING CONSTRUCTION.
U_
26.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES,
PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE,
Q
HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH
J
THEPERFORMANCE OF WORK. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT
NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVE BY THE PUBLIC WORKS R-402815
DEPARTMENT, TRANSPORTATION SYSTEMS DIVISION. ALL SECTIONS OF THE WSDOT STANDARD
J
SPECIFICATIONS 1-07-23 TRAFFIC CONTROL SHALL APPLY.
Q
27.
PROJECT LOCATED WITHIN THE
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
0
AQUIFER PROTECTION AREA (APA)
SHALL COMPLY WITH SPECIAL
V
REQUIREMENT #6 OF THE SURFACE
WATER DESIGN MANUAL AND AQUIFER
PROTECTION REGULATIONS (RMC
LJ,J
4-3-050).
J
0
C0
G
" McKNIGHT MIDDLE SCHOOL DAT1/15/2019 ~
CITY OF FIELD IMPROVEMENTS FIELDBOOK: 'R
RENTON RENTON SCHOOL DISTRICT PAGE: -
DRAWNG NO: z
Planning/Building/Public Works Dept. C3.5
NOTES &DETAILS SHEET: OF:
OF:32
N
O
I
1
0
W
I—
z
O
I-
\<
O
z
W
V J
J
W_
H
a
J
n
J
O
O
2
U
W
J
0
0
75
z
U
a
01
Co
N
Iv
M
z
z
Ld
1
BOLT -DOWN SLI
I DETAIL AND NO"
O�
A
4 � O
O�O�OpO�
OD�DO���O
B
TOP
4 3/4" 1 1/2"
2
3-1
T_
ff
39" R — SEE NOTE 2
SECTION OA
5"
3 1/r
3/4"
518"
4" M1/2'
3/4"DIAM. HOLE
1/2' DIAM. HANDLE
__7
SECTION O
1/2"
BOLT -DOWN SLOT RETAIL
SEE NOTE 1
SECTION OB
NOTES
1. Provide two slots in the cover that are vertically aligned
with the holes in the frame.Location of bolt -down slots
varies among different manufacturers.
2. Alternative reinforcing designs are acceptable in
lieu of the rib design.
3. Refer to Standard Specification 9-05.15(2) for additional
requirements
4. For Frame details, see City of Renton
Standard Plan 204.00.
ISOMETRIC
ti o STD. PLAN - 204.10
G/.•��'� PUBLIC WORKS RECTANGULAR SOLID
DEPARTMENT METAL COVER
FNT' MARCH 2O08
RECTANGULAR SOLID METAL COVER
NOT TO SCALE
y J. ,
TgABflIZ'
,
A
w
Q
z
z
z
0
LL
24'
t�
O O
TOP
NOTES
1 Provide two slots in the grate that are vertically aligned with the holes in the frame.
Location of bolt -down slots varies among different manufacturers.
2. Refer to Standard Specification 9-05.15(2) for additional requirements.
3. The thickness of the grate shall not exceed 1 5/8"-
4. Unless otherwise specified, vaned grates shall be used with standard frame
in the travel way, gutter or shoulder. vaned grates shall not be located
within crossroads. Use vaned grates along rolled curbs.
P.0- do KIM
ISOMETRIC
SLOT - SEE DETAIL
AND NOTE 1
3/8" (9mm) RECESSED
LETTERING
e
L&
3/4"
1 1/4"
BOLT -DOWN SLOT DETAIL
SEE NOTE 1
ti`iY �o STD. PLAN - 204.40
PUBLIC WORKS RECTANGULAR
\= �� DEPARTMENT HERRINGBONE GRATE
MARCH 2O08
RECTANGULAR HERRINGBONE GRATE
NOT TO SCALE
AS -BUILT
1 CERTIFY THAT THE INFORMATION SHOWN HEREON
ssIONALgE���
WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE
1/07/2019
0
LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND
AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING
- -
MID130
FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY
ALTERATION OF THIS DMENT SHALL I WXMTE THE
PRMMM& SEAL AND SIWTURE PUMTICNOF
Know whars bel OW.
DIRECT SUPERVISION ON THIS DATE: 11/7/2019.
THIS DOMWENT DOES NOT DEROGATE RM RESOM
01INERSHP WM IN ff. THS DOMWENT �
TAC0MA•SEATTLE•SPOKANE•TRI-CITIES
call before you dig.
AHBL PROJECT N0. 2180059
OWY FM THE PRUM 11ENTO IN THE AND IS NOT TO BE USED FOR REPAR" REMODEL OR
ADDITION TO THAT PR06ECT OR FOR ANY OTHER PROW.
1200 6th Avenue, Suite 1620 Seattle, WA 98101
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB
®V'CANTS - DRg7/KC
T
RENTON
AHEAD OF THE CURVE
I c�
DRAIN
1/2" [13mm] LETTERING
BOLTHOLES - 3 PLCS EQUALLY SPACED 120"
APART ON 231/16' (586mm) DIA B.C.
(1)1" (25mm)
DIA PICKHOLE
132mm] LETTERING
PLAN VIEW
25" DIA.
[635mm]
[25mm]
3/4"
[19mm] I�I
[222mm] Ism]
TYP
COVER SECTION VIEW
26 112" DIA
[673mm]
25 1/4' DIA
[641mm] 1 1/16"
1/4" (6mm) DIA [27mm]
NEOPRENE GASKET
6"
T} I [752mm]
J 23 3/8" DIA CL OPEN
[16mm] ~ [594mm]
27 5/16" DIA
[694mm]
34 1/8" DIA _
[867mm]
FRAME SECTION VIEW
COVER BOTTOM VIEW
(3) BLT SOC. (ALLEN HEAD)
SIR"_11 Y 1 S CC
EON BOLTING DETAIL
1/4'
[6mm] 1 1/16"
[27mm]
1/8"
[3mm]
1/8"
[R3mm]
GASKET GROOVE DETAIL
NOTES
ALL COVERS SHALL BE LOCKING LID PER EASTJORDAN IRONWORKS INC. No. 3717C1 Ij
OR APPROVED EQUAL.
tiY_o STD. PLAN - 204.50
PUBLIC WORKS STORM ROUND FRAME AND COVER
N� DEPARTMENT
MARCH 2O08
STORM ROUND FRAME AND COVER
NOT TO SCALE
CONSTRUCTION RECORD DRAWINGS
STORM DRAINAGE REVISIONS
1 ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS
NO. REVISION
SURVEYED:
DESIGNED:
AMT 09/20/2019 ACB DRAwN. AMT
AMT 01 28 2019 ACB CHECKED:
BJS
BY DATE APPR APPROVED:
WJF
SCALE:
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
HOR ON ALL NAD D1983//11991
DATUM
#6 BARS Q 7- SPACING
24" DIAM., 48" DIAM. J
OR 54" DIAM. HOLE
T (TYP) I-
12 1
1 Li
1" MIN.
1/2" MAX.
84" or 96" FLAT SLAB TOP
#5 BARS @ 6" SPACING
20" x 24",
24" DIAM., 48" DIAM.
OR 54" DIAM. HOLE
T (TYP. �-
m 1" MIN.
21/2" MAX.
72" FLAT SLAB TOP
#4 BARS @ 6" SPACING
20" x 24" OR
24" DIAM. HOLE
4
T (TYP.)
1" MIN.
2 1/2' MAX.
48", 54", or 60" FLAT SLAB TOP
TYPICAL ORIENTATION
FOR ACCESS AND STEPS
21 1
0 (V
48" MIN.
r 1
ECCENTRIC CONE SECTION
R IT
\�__ ONE #3 BAR HOOP FOR 6' <1>
TWO #3 BAR HOOPS FOR IT
RECTANGULAR ADJUSTMENT SECTION
1.0 As an acceptable alternative to rebar, wire mesh having a
minimum area of 0.12 square inches per foot may be used
for adjustment sections.
1`T'Y O
CITY OF
RENTON
Planning/Building/Public Works Dept.
12" (TYP.)
6o
v 8"
o.
12"
PREFABRICATED LADDER
12" MIN.
f0� N Z
rn
STEP
34"
�NE #3 BAR HOOP - ' '
�S«
CIRCULAR ADJUSTMENT SECTION
PUBLIC WORKS MISCELLANEOUS DETAILS FOR
DEPARTMENT DRAINAGE STRUCTURES
STD. PLAN - 204.60
MARCH 2O08
MISCELLANEOUS DETAILS
FOR DRAINAGE STRUCTURES
NOT TO SCALE
O
N
LO
C)
W
T
C)
C)
06
I
o�
z
O
Q
O
z
LU
0
J
W
H
Q
J
R-402816 I a
J
O
IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0
McKNIGHT MIDDLE SCHOOL
FIELD IMPROVEMENTS
RENTON SCHOOL DISTRICT
NOTES & DETAILS
U
J
n
0
=
' R
DATE:
1/15/2019
FIELDBOOK:
PAGE:
v_
z
DRAWNG NO:
C3.6
C�
G
SHEET: OF:
OF:32
a
Ln
a
_m
N
LJ
a
z
Ld
O
It
I
0
w
Z
O
a
O
Z
w
0
w
H
3 LF 36" @ 0.00%
a
n
J
O
O
U
U)
W
J
I� \
5�
L \
2 �
Z \
U
L
NOTES
BASE BID
185 LF 60" @ 0.00%
108 LF 60" 0.00%
2 LF 60" @ 0 ,22%7 1�
DETENTION TANK
ACCESS RISER (TYP.)
3 �
2 LF 36" @ 0.00%
112 LF 60" @ 0.00%-
112 LF 60" @ 0.00%�
112 LF 60 @ 0.00%
112 LF 60" @ 0.00%
-M -
112 LF 60" @ 0.00%-\
104 LF 4" @ 2.18% 'Z•
ID
O-
3°�°
/ O
13�
�O
>00-
p l`s.a/ l / / • V o�0
`ID
ID
1ol0 51 .
(Q
\ \ 4 ID 1 , @1' $ LF p°�° 2.5' TYP. pC11d
0 ID No
lJ C
BASEBALL DETENTION TANK SYSTEM PLAN VIEW
1 NOT TO SCALE
2"S
CC
36" ALUMINIZE
CORRUGATI
PIPE TO MANI
ALL DETENTION TANK
ALUMINIZED TYPE 2
CORRUGATED METAL, X"
1", (16 Ga.), AT S=0.0%.
ALUMINIZED OR
GALVANIZED WITH
TREATMENTS 1, 2 OR 5.
DETENTION TANK SYSTEM TYPICAL SECTION
NOT TO SCALE
Of
ZW
20
0
U
DETENTION TANK
ID DIAMETER INVERT CROWN
BASEBALL 60" O 84 .69'849.59, BASE BID
344.43 349.43
rr
GRAVEL BACKFILL
FOR DRAINS
WSDOT 9-03.12(4)
')fASgj������
cjg
Ok
w
. r
AS -BUILT
CERTIFY THAT THE INFORMATION SHOWN HEREON
�SSIONAL E��l
EEI
WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE
1/07/2019
O
LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND
AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING
-
1010130
FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY
ALTERATION aF THIS DOCUMENT SHALL INVALDATE THE
ksEALAmsmiumPueLtcAToOF
Know what's below.
DIRECT SUPERVISION ON THIS DATE: 11/7/2019.
THIS DOCUIOIT DOES NOT DEIMTE FM RESETtVEO
00111 WM IN ff. THIS DODASIT �
TAC0MA•SEATTLE•SPOKANE•TRI-CITIESONLY
1
Call before you dig.
AHBL PROJECT NO.2180059
FOR THE PRUM IDENTIFIED IN THE
AND IS NOT TO BE USED FOR REPAR" RENOUEL OR
Ate+'M THAT FRO,ECT OR FOR ANT UM I>ROM.
1200 6th Avenue, Suite 1620 Seattle, WA 98101
NO.
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB
D_
31 LF 48" @ 0.00%
CONTROL
STRUCTURE
2 LF 36" @ 0.00%
--�-D--
_ _D
62 LF 8" 8"-@W
ALTERNATE BID NO. 7
SOCCER DETENTION TANK SYSTEM PLAN
NOT TO SCALE
mmpection
itt
: � tea, limits of pipe
compaction
for pipe beddi g foundations when specified
n0.15 rise Mn.
Rigid Pipe NOTES:
1. Pipe compaction limits shown on this plan are for pipe
construction in an embankment. For pipe construction
in a trench, the horizontal limits of the pipe compaction
zone shall be the walls of the trench.
2. All steel and aluminum pipe and pipe -arches shall be
installed in accordance with design A.
3. Concrete pipe with elliptical reinforcement shall be
installed in accordance with design A.
4. Concrete pipe, plain or with circular reinforcement, shall
be installed with design A.
5. D.D. Is equal to the outside diameter of a pipe or the
outside span of pipe -arch. The dimensions shown as
O.D. with T maximum shall be O.D. until O.D. equals
3'; at which point 3' shall be used.
* 1'-0" for diameters 12" through 42" and spans through
50". 2'-0" for diameters greater than 42" and spans
greater than 50".
W(see note 4)
limit of pipe one
beddng
material c
forfle:dble
pipe (see
note 6)
m O.D.
foundation
level
" Am 4" min. 27" I.D. and under
6" min., over 27" I.D.
Bedding for Flexible Pipe
Flexible Pipe NOTES:
1. Provide uniform support under barrels.
2. Hand tamp under haunches.
3. Compact bedding material to 95 % max. density; directly
over pipe, hand tamp only.
4. See 'Excavation and Preparation of Trench" in sanitary
sewers section of the standard WSDOT/APWA
specifications for trench width "W" and trenching
options. The pipe zone will be the actual trench width.
The minimum concrete width shall be 1 z I.D. = 18".
5. Trench backfill shall conform to "Backfilling Sewer
Trenches" in the sanitary sewers section of the
WSDOT/APWA standard specifications, except that
rocks or lumps larger than 1" per foot of pipe diameter
shall not be used In the backNll material.
6. See "Bedding Material for Flexible Pipe" In aggregates
section of the WSDOT/APWA standard specifications
for the material specifications.
®Backfill material placed in 0.5' loose layers and
compacted to 95 % maximum density.
Method B or C compaction (WSDOT/APWA)
standard specifications.)
Pipe
Size
Min. dist.
between
barrels
circular pipe
conc., LCPE, CMP
(diameter)
12" to 24"
12"
30" to 96"
diam. / 2
102" to 180"
48"
pipe - arch
metal only
(span)
18" to 36"
12"
43" to 142"
span / 3
148" to 199"
48"
TY o PUBLIC WORKS PIPE COMPACTION STD. PLAN - 220.00
DEPARTMENT DESIGN AND BACKFILL MARCH 2O08
PIPE COMPACTION DESIGN AND BACKFILL
(COR STD. PLAN 220.00)
NOT TO SCALE
CONSTRUCTION RECORD DRAWINGS
SURVEYED: SCALE:
VERTICAL:L: p 13/1991
DESIGNED: AS SHOWN HORIZONTAL: N 98
STORM DRAINAGE REVISIONS AMT 09/20/2019 ACB DRAWN. AMT
ONE INCH DATUM
ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS AMT 01 28 2019 ACB CHECKED: AT FULL SCALE
BJS IF NOT ONE INCH
REVISION BY DATE A P P R APPROVED: SCALE ACCORDINGLY
WJF
" CITY OF
RENTON
Plonning/Building/Public Works Dept.
41 FG: 349.81
-160 LF 48" @ 0.00%
-160 LF 48" @ 0.00%
160 LF 48" @ 0.00%
QLF 48" @ 0.00%
V r.." L r
48" TYPE 2 CB
RIM: 349.30
_ IE: 342.75 36" (W)
FEE. 346.96 8" (NE)
191
4
't
O
L0
O
00
16
O
O
CIS
W
z
0
a
O
z
w
0
J
W
LL
Q
R-402817 a
J
IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0
McKNIGHT MIDDLE SCHOOL
FIELD IMPROVEMENTS
RENTON SCHOOL DISTRICT
NOTES & DETAILS
U
J
0
=
' R
DATE:
1/15/2019
FIELDBOOK:
PAGE:
v_
z
DRAWNG NO:
C3.7
SHEET:OF: 1 7 32
00
N
O
It
I
1
w
z
O
Q
>
O
z
w
rr
0
W_
U_
a
n
1
O
O
U
w
0
Co
G
2
0
z
U
Ln
_m
N
LJ
a
z
Ld
RIM ELEV: "G" PER TABLE
zQ
T2 -
° d
cz p
OVERFLOW a
ELEV: "F" PER TABLE r�'4
a �
a : MAX.
RESTRICTOR ELBOW W.S.
SEE DETAIL 3
d
a:
PIPE SUPPORT(S): 3" X .090" 12"
RISER
12" OUTLET PIPE
IE: "D" PER TABLE d.
MIN. i"I
e 'd.
z_
RESTRICTOR PLATE
ORIFICE 1: "B" PER TABLE
ELEV: "A" PER TABLE
d
60" 0
MANHOLE TYPE 2
0
CONTROL STRUCTURE (CB-03
NOT TO SCALE
-#5 @ 12" O.C. SHORT (4) #5 TOP &
BARS TOP & BOTTOM BOTTOM
(TYPICAL) LONG BARS
NOTES:
ROUND SOLID COVER 1. PIPE SIZES AND SLOPES: PER PLANS.
WITH LOCKING BOLTS.
FRAME & LADDER OR 2. EXCEPT AS SHOWN OR NOTED, UNITS SHALL BE CONSTRUCTED IN ACCORDANCE
WITH THE REQUIREMENTS FOR CATCH BASIN TYPE 2, 60" MIN. DIAM.
STEPS OFFSET. SEE
NOTE 8. FRAME &
3. PIPE SUPPORTS AND RESTRICTOR/SEPARATOR SHALL BE OF SAME MATERIAL, AND
COVER ELEV. PER PLAN.
BE ANCHORED AT 3' MAX. SPACING BY 5/8" DIAM. STAINLESS STEEL EXPANSION
2" 0 AIR VENT BOLTS OR EMBEDDED 2" IN WALL.
IE: "E" PER TABLE
4. THE RESTRICTOR/SEPARATOR SHALL BE FABRICTED FROM 0.060" ALUMINUM, OR .064"
EXTEND TO LANDSCAPE
AREA FINISHED GRADE. ALUMINIZED STEEL, OR .064" GALVANIZED STEEL PIPE; IN ACCORDANCE WITH
AASHTO M 36, M 196, M 197 AND M 274. GALVANIZED STEEL SHALL HAVE TREATMENT
1.
STEPS OR LADDER 5. OUTLET SHALL BE CONNECTED TO STORM PIPE WITH A STANDARD COUPLING BAND
FOR CORRUGATED METAL PIPE, OR GROUTED INTO THE BELL OF CONCRETE PIPE.
6. THE VERTICAL RISER STEM OF THE RESTICTOR/SEPARATOR SHALL BE THE SAME
INLET PIPE DIAM. AS THE HORIZONTAL OUTLET PIPE, WITH AN 12" MIN. DIAM.
7. FRAME AND LADDER OR STEPS OFFSET SO THAT:
A. CLEANOUT GATE IS VISIBLE FROM TOP.
B. CLIMB DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE.
C. FRAME IS CLEAR OF CURB.
IE: "C" PER TABLE
8. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO
CLEANOUT GATE: HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1/4".
SHEAR GATE.
SEE DETAIL 2 9. MULTI -ORIFICE ELBOWS MAY BE LOCATED AS SHOWN OR ALL ON ONE SIDE OF RISER
THIS SHEET. TO ASSURE LADDER CLEARANCE.
10. ACCESS OPENING SHALL BE CLEARLY MARKED WITH CONFINED SPACE WARNING IN
ACCORDANCE WITH OSHA AND L&I REQUIREMENTS.
CONTROL STRUCTURES
ID A B C D E F G
CB-03343.99' 1.9" 0 345-88 345-68349.76'349.00 OG�8 BASE BID
342.86 344.86 344.86 349.61 348.86 352.58
G_P 17 2-4Q_75' ' -6C)0842.75842.75' 84650' 845.75' 844.41., A' IERNATE BID NO.1
PAVED AREAS
1/2" RADIUS
(4) #5 TOP & BULLNOSE EDGE 3 8
BOTTOM TYP. 4 SIDES
LONG BARS �I
CONCRETE N I
INCREASE DEPTH T
AS REQUIRED TO
MEET VERTICAL �r /
ELEVATION OF THE
ACCESS RISER r
6" MIN.
6" MIN. I
#5 DIAGONALS
TOP & BOTTOM
CONCRETE: 4000 PSI MIN. @ 28
DAYS 6 SACK MIX REBAR
GRADE 60
DETENTION PIPE ACCESS RISER
NOT TO SCALE
pg TgA3,7I��L1
AS -BUILT ��w� ■1
1 CERTIFY THAT THE INFORMATION SHOWN HEREON o��ssIONALgE���
WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE 1/07/2019 _
0 LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND
AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING - -
ALTERATION OF THIS DMENT SHALL INVXMTE THE
FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY PRIYESMINAL SEAL AND SIGNATURE. PUBMTIa+OF
THIS DOCUMENT DOES NOT DEROGATE FROM RESERVED
Know wharsbelOW. DIRECT SUPERVISION ON THIS DATE: 11/7/2019. ONNERSHP WIM IN ff. THIS DOMUNT � TACO MA•SEATTLE•SPOKANE•TRI-CITIESONLY FOR THE PKM IDENTIFIED IN THE 1
RM
AND IS NOT TO BE USED FOR REPAlk REMODEL OR
call before you dig. AHBL PROJECT NO.2180059 ADDI110N TO THAT PRONECT OR FOR ANY OTHER PRo M. 1200 6th Avenue, Suite 1620 Seattle, WA 98101 NO.
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEE
UNPAVED AREAS
BOLT -DOWN CIRCULAR FRAME
AND COVER PER WSDOT STD
PLAN B-30.70-03
4" STYROFOAM MAT CUTOUT @
LID OPENING
k� #5 @ 12" O.C. EACH WAY
MAXIMUM OPENING
OF GATE
SIX EVENLY SPACED
HOLES ON 10 3/8" BOLT
CIRCLE FOR BOLTING TO
FLANGE CONNECTION.
�� LIFT HANDLE
`LEVEL LINE
�
O
O
O O
FRONT
HANDLE WITH
LOCK PIN.
ADJUSTABLE LOCK
HOOK WITH LOCK
SCREW.
1" ROD OR
TUBING,
VARIABLE
LENGTH.
O
SIDE
LIFT HANDLE SHALL
BE ATTACHED PER
MANUFACTURER'S
RECOMMENDATIONS.
SHEAR GATE
NOT TO SCALE
^oovoovoo
.000000 ;:
LOAD TRANSFER SLAB
I
LADDER LATERAL
SUPPORT SECURED
TO PIPE OR RISER
AS APPLICABLE, 4'
MAX SPACING, MIN.
2 REQ'D
STEPS @ 12" O.C.
36"0 ALT2 RISER WELDED TO
ALT2 DETENTION PIPE
NOTES:
1. SHEAR GATE SHALL BE ALUMINUM ALLOY PER
ASTM B-26-ZG-32a OR CAST IRON ASTM A48
CLASS 30B AS REQUIRED.
2. GATE SHALL BE 8" DIAM. UNLESS OTHERWISE
SPECIFIED.
3. GATE SHALL BE JOINED TO TEE SECTION BY
BOLTING (THROUGH FLANGE), WELDING, OR
OTHER SECURE MEANS.
4. LIFT ROD: AS SPECIFIED BY MFR. WITH
HANDLE EXTENDING TO WITHIN ONE FOOT OF
COVER AND ADJUSTABLE HOOK LOCK
FASTENED TO FRAME OR UPPER HANDHOLD.
5. GATE SHALL NOT OPEN BEYOND THE CLEAR
OPENING BY LIMITED HINGE MOVEMENT, STOP
TAB, OR SOME OTHER DEVICE.
6. NEOPRENE RUBBER GASKET REQUIRED
BETWEEN RISER MOUNTING FLANGE AND
GATE FLANGE.
7. MATING SURFACES OF LID AND BODY TO BE
MACHINED FOR PROPER FIT.
8. FLANGE MOUNTING BOLTS SHALL BE 3/8" DIAM.
STAINLESS STEEL.
9. ALTERNATE CLEANOUT/SHEAR GATES TO THE
DESIGN SHOWN ARE ACCEPTABLE, PROVIDED
THEY MEET THE MATERIAL SPECIFICATIONS
ABOVE AND HAVE A SIX BOLT, 10 3/8" BOLT
CIRCLE FOR BOLTING TO THE FLANGE
CONNECTION. ALTERNATE SHALL BE
REVIEWED AND APPROVED BY ENGINEER.
D
EDGE OF SLAB SHALL EXTEND
PAST EDGE OF PIPE AND
SHALL NOT REST ON PIPE
PREFABRICATED LADDER (WSDOT STD. PLAN
NO. B-30.90-01) ATTACH TO LOAD TRANSFER
SLAB. TYPICAL FOR ALL PIPE TYPES
18" MAX
6" MIN
PER PLAN
NOTES:
1. LOAD TRANSFER SLAB IS REQUIRED ON RISERS LOCATED WITHIN PAVED AREAS.
2. ACCESS RISERS ARE SAME MATERIAL AS DETENTION TANK.
3. ACCESS RISER SPACING IS 100' MAXIMUM.
4. ACCESS OPENING SHALL BE CLEARLY MARKED WITH CONFINED SPACE WARNING IN
ACCORDANCE WITH OSHA REQUIREMENTS
5. ALT2 - ALUMINIZED TYPE 2 CORRUGATED METAL PIPE
CONSTRUCTION RECORD DRAWINGS
SURVEYED: SCALE: VERTICAL: NAVD 1988
AS SHOWN HORIZONTAL: NAD 1983/ 1991
DESIGNED:
STORM DRAINAGE REVISIONS AMT 09/20/2019 ACB DRAWN: AMT
ONE INCH DATU M
ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS AMT 01 28 2019 ACB CHECKED: AT FULL SCALE
IF NOT ONE INCH
REVISION BY DATE A P P R APPROVED: SCALE ACCORDINGLY
WJF
CITY OF
RENTON
NUF
Planning/Building/Public Works Dept.
REMOVABLE
WATERTIGHT
COUPLING
6" PIPE
ELEV PER TABLE
ORIFICE: DIA. PER TABLE
RESTRICTOR ELBOW DETAIL
NOT TO SCALE
RESTRICTOR
ELBOWS
RISER
ID ORIFICE 2 �
DIA. ELEV
N
CB-03 6.8" O
BASE BID L0
� �
348.41 ALTERNATE BID NO.1 C/'yD)
" 0 344.85
T
RESTRICTOR ELBOW
NOT TO SCALE
0
a
O
z
w
CONTROL STRUCTURE (CB-03)
NOT TO SCALE
LL
Q
J
R-402818 a
0
IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0
McKNIGHT MIDDLE SCHOOL
FIELD IMPROVEMENTS
RENTON SCHOOL DISTRICT
DRAINAGE NOTES & DETAILS 4
U
U)
J
0
=
' R
DATE:
1/15/2019
FIELDBOOK:
PAGE:
v_
z
DRAWNG NO:
C3.8
SHEET:OF:
1 $ 32
BASE & ROOT SAND
00
N
O
O
i
LU
z
O
Q
O
z
LU
0
W_
LL
J
n
J
O
O
U
LU
J
0
0
z
CU
G
Ln
_o
N
LJ
a
z
Ld
VARIES
SEE PLAN FOR I.E.
cg2"
-
GEOTEXTILE FABRIC _
\
COMPACTED
/
SUBGRADE
i
6-0"
NOTES:
1. SLOPE LAST 5' OF 4" PERF. PIPE TO
MAKE CONNECTION TO TIGHTLINE.
2. BACKFILL TIGHTLINE TRENCH W/ PEA
GRAVEL IN SAME MANNER AS PERF.
PIPE TRENCHES.
3. (2) TWO WRAPS OF DUCT TAPE
REQUIRED AT ALL CONNECTIONS.
4. SEE SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
CONNECTION T
NOT TO SCALE
4" OF ROOT ZONE SAND
8" OF CLEAN DRAIN SAND
30% VOID GRAVEL
91,
FINISH GRADE
1/8"X3/8" PEA GRAVE BACKFILL
GEOTEXTILE FABRIC
4" ADS PERF. PIPE
ALT. CONNECTION WHERE
INVERT ELEVATION ALLOW.
VARIES 90 DEG. ELL. W/90 DEG.
REDUCING SNAP TEE.
ADS N-12 S-P COLLECTOR
DRAIN SIZE AS PER PLAN
90 DEG. REDUCING SNAP
TEE OR 45 DEG. SNAP Y
AND REDUCING COUPLING
AS REQUIRED. (NO SADDLE
TEES)
SEE PLAN FOR
COLLECTOR INVERT
ELEVATION. (C.I.E.)
2" DEPTH MIN. DEPTH
PEA GRAVEL BENEATH
PIPE (TYP.)
O COLLECTOR DRAIN
NOTE: REFER TO
SPECIFICATIONS FOR
ADDITIONAL INFORMATION
ADS N-12 S-P
TIGHTLINE (8")
COLLECTOR
DRAIN AS PER
PLAN
o\\ o \
24"
rA'* *, - 8" COLLECTOR DRAIN
NOT TO SCALE
GEOTEXTILE FABRIC
12" MIN.
J .
w
AS -BUILT
��w�
F,?
o�41 GIST
m
I CERTIFY THAT THE INFORMATION SHOWN HEREON
"IONALgE�
_
WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE
1/07/2019 0
LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND
AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING
-D -
�
FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY
ALTERATION OF THIS DOCUMENT SHALL INVALDATE THE
PRMMN& SEAL Ale Swum PUMTOOF
Know what'sbeloW.
DIRECT SUPERVISION ON THIS DATE: 11/7/2019.
THIS DOCUMENT DOES NOT OEROGAIE FROM RESERVED
0011ERSHP WIM IN ff. THIS DOMUNT �
TACOMA SEATTLE•SPOKANE•TRI-CITIESOWY
1
Call before you dig.
AHBL PROJECT NO.2180059
FM THE PRUM MTIFB IN THE
AND IS NOT TO BE USED FOR REPAR, REMODEL OR
ADDIM TO THAT MMCT OR FOR ANY DTHER PROMEDL
1200 6th Avenue, Suite 1620 Seattle, WA 98101
NO.
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB
NOTES:
8" PVC PIPE
1. ALL TRENCHES SHALL BE COMPLETELY CLEAR OF ROCKS, DIRT
FEMALE CLODS, ETC. AND SHALL HAVE A SMOOTH BOTTOM, SLOPED AS
ADAPTER WITTHH TTHRHREAA DED PLUG DESIGNED PRIOR TO LAYING PIPE. ALL TRENCHES SHALL BE
FINISH GRADE INSPECTED BY OWNER REPRESENTATIVE PRIOR TO BACK
PLACE LOCATE WIRE AT ENDS FILLLING.
OF ALL CLEANOUTS AND CAPS �I ' �''' �"YID"'YI�I'1° "�'''�"'YI�''ul�"1°I� �I'' '�I''P �'''Y"'Iu„Iul�l, ICI'' �I'' '�''I 2. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
FINI H RADE S G
6"
.. � a •� •. .,..••,,.'•;,, • I I II 'r iy Ii , I, , I I •r II , iI ,II y I: I I II
,.:.......� :.......:.....•.:.:;:.:::::�,..,.,..:•,,..::::..;.;•:,•.;:�;.;.�`:�.<':;:,..:;,,�:.,•�:..':'.,.,::�,,:•:..:;;.:,.._:...,..:;;,.:>..:>:;-�:�,• (fll��lll�'I I� �hJ �hVl �h41 Y111 �I I�� I�fiV ��G ��p �flll�l III' I�'i,
....:....., ..... .:. ROOT SAND
4
0 o O° o° o° O°o O°
oo,,,� cp oo,,,, o� p� W W o 0 °oo °oo °oo
0 0 0 0
0 o O
0 0 0 8 0
0
0 0 0 O
0 0 0
0 0 0
0
O o
e °
BASE SAND
0
° $ 8"
PVC RISER LENGTH AS REQUIREDOU
0
°
°
0 0 0 & o
O
0
O
0
0
0
0
..00,
PVC 45 CONNECTOR ° oo ° ° ° /\\�� ° s ° og °°
e '
00
PVC PIPE ° ° o° °°o ° \ e° °°°°°
\/ PEA GRAVEL BACKFILL °g ° ° o°®oo 6" MIN.
00 0 ° °° ° \\\�\\\ 0° q5 8
° ° ° a o o'0 /\ GEOTEXTILE FABRIC °°oO
° /\\\/\ 4" ADS N-12 PERF. PIPE
2" MIN (PLACE PERFORATIONS DOWN)
°° ° °° ° °° °° /\�� 1 /8" x 3/8" PEA GRAVEL BACKFILL 12"
ADS N-12 S-P COLLECTOR \/\\\j\\ \\\/ FIRM TRENCH SIDES WITH NO
DRAIN AS PER PLAN 12" LOOSOFTEMATERIAL ON BOTTOM
NOTE: \\
NCH
CORRUGATED PIPE TO 1. SEE SPECIFICATIONS
PVC PIPE ADAPTER FOR ADDITIONAL
INFORMATION.
COLLECTOR DRAIN CLEANOUT
NOT TO SCALE
RIM PER PLAN
INTEGRATED DUCTILE IRON
GRATE TO MATCH BASIN O.D.
SEE NOTE 2.
I
DEPTH TO INVERT
VARIES PER PLAN
IE PER PLAN
ADAPTOR FOR 8" PVC PIPE —/
BY DRAIN MANUFACTURER
WATERTIGHT JOINT
BY DRAIN MANUFACTURER
GRAVEL BACKFILL FOR
DRYWELLS PER WSDOT
SPEC. 9-03.12(5)
V MIN SUMP —J 6" MIN
4" PERFORATED UNDERDRAIN
NOT TO SCALE
3 NEW PERFORATED
C3.9 UNDERDRAIN AS PER
PLAN
... ....:.... ...::
V \/j SUITABLE NATIVE, PER
BEARING PAD PER WSDOT SPEC. \\ \\ SPECIFICATIONS
9-03.12(5). BEDDING & BACKFILL \ ,.
12" FOR SURFACE DRAINAGE INLETS 5' MIN. 5' MIN.
SHALL BE PLACED & COMPACTED (TYP) (TYP) 4" THICK CDF
UNIFORMLY TO 95% MINIMUM. (6 ))
1. AREA DRAIN SHALL BE NYLOPLAST DRAIN
BASIN WITH FLAT GRATE OR APPROVED
ALTERNATIVE.
2. GRATES SHALL BE DUCTILE IRON PER ASTM
A536 GRADE 70-50-05.
3. DRAIN BASIN TO BE CUSTOM MANUFACTURED
ACCORDING TO PLAN DETAILS.
4. DRAINAGE CONNECTION STUB JOINT
TIGHTNESS SHALL CONFORM TO ASTM D3212
FOR PVC SEWER.
5. MANUFACTURER TO PROVIDE ADAPTERS FOR
CONNECTING PIPES TO AREA DRAIN AT
ANGLES SHOWN ON PLAN.
6. GRATES HAVE NO LOAD RATING. DO NOT
DRIVE VEHICLES ON GRATES.
AREA DRAIN.
NOT TO SCALE
CONSTRUCTION RECORD DRAWINGS
SURVEYED: SCALE: VERTICAL: NAVD 1988
AS SHOWN HORIZONTAL: NAD 1983/ 1991
DESIGNED:
STORM DRAINAGE REVISIONS AMT 09/20/2019 ACB DRAW AMT
ONE INCH DATU M
ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS AMT 01 28 2019 ACB CHECKED: AT FULL SCALE
BJS IF NOT ONE INCH
REVISION BY DATE A P P R APPROVED: SCALE ACCORDINGLY
WJF
EXISTING WATER MAIN
0[61112
PLACE 4" CDF ALONG THE ENTIRE LENGTH OF THE EXISTING WATER MAIN
LOCATED BELOW THE PROPOSED PERFORATED UNDERDRAINS AND
COLLECTOR PIPES.
EXTEND THE CDF 5 FEET BEYOND THE LIMITS OF THE UNDERDRAINED FIELD.
WATER MAIN PROTECTION
NOT TO SCALE
CITY OF
I-%w0R_.,JW RENTON
Planning/Building/Public Works Dept.
O
N
L0
O
O
CID
16
z
0
a
O
z
w
0
J
W
LL
Q
J
R-402819 a
0
IN COMPLIANCE WITH CITY OF RENTON STANDARDS O
McKNIGHT MIDDLE SCHOOL
FIELD IMPROVEMENTS
RENTON SCHOOL DISTRICT
UNDERDRAIN DETAILS
2
U
J
0
DATE:
1/15/2019
=
FIELDBOOK:
' R
PAGE:
v_
DRAWNG NO:
z
C3.9
SHEET:OF:
19 32
00
C)
W
z
O
Q
>
O
z
W
CI)
0
LU
L.L
J
J
O
O
2
CU
LU
J
0
0
0
z
U
0
LO
N
lil
a
Z
w
N 187026.05
E 1306471.57
N 'l01UZ"I.UZ_
E 1306474.20
2y
I
2 I
FQ
3Q
34
20
3
.28
I
I
I
I
I
I
I
I
I
I
i
I
I
�
N 187038.92 V0
E 1306494.40 i _��. ,r-,
_ E 1_3066 1.73
E 1306516.89 6 1 - ■
_ N 187124.23
'Ilk 0 — D — — _ = EE 1306665.31 �CIIi�TCH EXISTING:
0 042E N 187033.46 i _ — D — — MATCH
"F� 1306498.18 _ - _ EXISTING �\1
ten— N 187049.92 D
19.44
D D —
L-FG: 352.6N 187129.26
r l�. /
�I MATCH / E 1306689.88
N 187025.7*6 / EXISTING9 — p
E 1306488.17: U - D D / ■
/
al o / �p
'■
M� / / — D — / p ST
/ Riff C.)
,�,
/ U D �' D D �2.. c w
/ 355
L L]
LU
D / D D z
J
/� ■ _
D D D N 187040.84 ■ C)
N 187 4 E 1306715.99
355 06708.34
I Io D
I I ____FG: 355.60
MATCH
MATCH EX!ST!NG
0-q_RI III T
I "'L II 1 11 I/'11 11 IL IIVJV V I Vf11Vl/'111VIV I IVVII ILLILVIV
WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE
LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND
AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING
kiFIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY
Know what's beIOW. DIRECT SUPERVISION ON THIS DATE: 11/7/2019.
Call before you dig. AHBL PROJECT NO.2180059
D 1F
2.99
37.29 ■
■
■
■
■
T�
CH •
��NF
s�
C42
BASE BID
PROPOSED LEGEND:
CONSTRUCTION RECORD DRAWINGS
W W V V STORM DRAINAGE REVISIONS
TACO MA- SEATTLE•SPOKANE•TRI-CITIES Al ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS
1200 6th Avenue, Suite 1620 Seattle, WA 98101 NO. REVISION
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com wEa
SURVEYED:
DESIGNED:
AMT 09/20/2019 AC B DRAWN. AMT
AMT 01 28 2019 ACB CHECKED:
BJS
BY DATE APPR APPROVED:
WJF
SCALE:
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
a
PLAN NOTES
CONCRETE SIDEWALK 2
C4.3
ASPHALT CEMENT 1
C4.3
1. PROTECT EXISTING CURBS AND PAVEMENT FROM DAMAGE
DURING CONSTRUCTION.
2. PROVIDE HOT TAR SEAL AT ALL JOINTS. COMPLETELY FILL ALL
JOINTS. (TYP.)
VERTICAL: NAVD 19M
HORIZONTAL: NAD 1983/1991
DATU M
KEYMAP
CITY OF
RENTON
Planning/Building/Public Works Dept.
GRAPHIC SCALE
0 10 20 40
1" = 20 FEET
O
L0
O
00
T
16
O
O
O
I
00
rr
0-
z
O
Q
O
z
LU
oC
0
J
W
H
Q
J
R-4028201�
O
IN COMPLIANCE WITH CITY OF RENTON STANDARDS O
McKNIGHT MIDDLE SCHOOL
FIELD IMPROVEMENTS
RENTON SCHOOL DISTRICT
GRADING, PAVING &
HORIZONTAL CONTROL PLAN
2
U
W
J
0
=
DATE
1/15/2019
FIELDBOOK:
PAGE
_
z
DRAWING NO:
C4.0
SHEER OF.32
00
0
I
W
z
O
Q
O
z
W
cn
0
W_
H
J
J
O
O
U
cn
W
J
0
0
z
U
G
0
LO
m
N
lil
Q
Z
w
REPAINT CURB AND NO PARKING
'
FIRE LANE" TO MATCH EXISTING N 187255.8
E 1306814.9
MATCH
EXISTING
Sp
e#S�� N 1872
pp RAM' T yp E 13068
S�, �F.• 34 6 66
6 96
■
■
_ N 187229.26
�— 1'�7176.15 E 1306805.97
E 1306754.24
■
D
r —
FG: 354.11-
\ \ MATCH
EXISTING
N 187170.88
E 1306773.23
D
� \ O
s F D �\ D
2 \
Sw ,�F• 346 � \
33 \D
o■
(�
D —
W
W
— D
■
(/)
■
D
W
z
J
D —
Q
■
D
—
10
i
,35
i
M�Tcy`S •�
.2
A A II III T
REPAINT NUMB
TO MATCH
EXISTING
/-- REPAINT CURB AND "NO PARKING FIRE L E"
TCH EXISTING
N 187260.34
E 1306824.57
MATCH
EXISTING
°
IvlP I V1 1
EXISTING
N 187222.53
E 1306825.11
O
— D
N 187162.12 \
E 1306842.5:� \\
\ O
O
\4
\
0
\
• WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE
LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND
AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING
FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY
Know what's beIOW. DIRECT SUPERVISION ON THIS DATE: 11/7/2019.
Call before you dig. AHBL PROJECT NO.2180059
O/
187245.61
1306832.83
ATCH
KISTING
w� ■1
/07/2019 gar
)ATE THE
MON OF ID La
FOR USE T A C O M A - SEATTLE • SPOKANE •TRI-CITIES
LE BLOCK
sT
8" ce#SD
8.. Cpp Rr 3 T rp
CAp Np, 3S F
Cpp SW\44 Si348S
' 8
1200 6th Avenue, Suite 1620 Seattle, WA 98101 I N 0.
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEE
r—
AT COMPLETION OF
CONSTRUCTION,
REMOVE
TEMPORARY
PAVEMENT AND
RESTORE AREA TO
EXISTING
I
CONDITIONS
\41
N 187087.21 \ \
E 1306951.41 \
`
FG:353.89
MATCH
EXISTING
BASE BID_
PROPOSED LEGEND:
CONCRETE SIDEWALK 2
C4.3
ASPHALT CEMENT 1
C4.3
PLAN NOTES
1. PROTECT EXISTING CURBS AND PAVEMENT FROM DAMAGE
DURING CONSTRUCTION.
2. PROVIDE HOT TAR SEAL AT ALL JOINTS. COMPLETELY FILL ALL
JOINTS. (TYP.)
CONSTRUCTION RECORD DRAWINGS
SURVEYED:
DESIGNED:
STORM DRAINAGE REVISIONS AMT 09/20/2019 ACB DRAWN. AMT
ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS AMT 01 28 2019 ACB CHECKED:
BJS
REVISION BY DATE APPR I APPROVED:
WJF
SCALE
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 19M
HORIZONTAL: NAD 1983/1991
DATUM
X
0
KEYMAP
CITY OF
RENTON
Planning/Building/Public Works Dept.
GRAPHIC SCALE
0 10 20 40
1" = 20 FEET
0
N
L0
O100
u
0
0
I
100
0
a
O
z
w
0
J
W
LL
Q
J
R-402821 a
O
IN COMPLIANCE WITH CITY OF RENTON STANDARDS O
2
U
W
J
50
G
McKNIGHT MIDDLE SCHOOL �1/15/2019 ~
FIELD IMPROVEMENTS =
FlELDBOOK:
RENTON SCHOOL DISTRICT PAGE —
G RA D I N G, PAVING & DRAWING NO: z
C4.1
HORIZONTAL CONTROL PLAN r
HEER OF21 .
00
It
't
0
w
z
O
Q
O
z
w
rr
0
J
W
LL
a
J
In
J
O
O
VJ
w
J
0
75
2
z
U
0
LO
0
m
N
W
zz
w
N
E13
z
m
N
m
m
► q
M
►
AT H ►
EXI
TIMG ►
848
I
.87
568
.87 II
E
1864.I9-2.32
3066i 1.07
TCH
-I NG
m
z
\"
r,
\� 1
I
1 I
0
11
1 N 186511.73_
1 E 1306854.68'',
1
I
N 186497.79
E 1306683.27
N 186506.03
E 1306690.71
11 II 1 : EN 1865 J 3068 4.78MV LID
1/` / / / I
Know what's beIOW.
Call before you dig.
_--W—-
--W__
y� J �r
� pg TgA,$JI���
HARRINGTON AVE NE
AS -BUILT 1p w� ■_
9.� EGISTEg�
1 CERTIFY THAT THE INFORMATION SHOWN HEREON �SSIONAL E���
WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE 1/07/2019
LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND
AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING - -
ALTERATION OF THIS DOCUMENT SHALL INVALDATE THE
FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY PRWESMNA. SE& AMSNHaTURE.vueuc70OF
THIS DOCUMENT DOES NOT DEROGATE FROM RESERVED
DIRECT SUPERVISION ON THIS DATE: 11/7/2019. 011FERSFPWMNff. THIS DOCINIMISFOR USE TACOMA SEATTLE SPOKANE TRI-CITIES
ONLY FOR THE PRUW DENTIFED N THE MERE BLOCK
AND IS NOT TO BE USED FOR REPAIR, REMODEL OR
AH BL PROJECT NO. 2180059 ADDFnoN TO THAT PRO,ECT OR FOR ANY OTTER PRUM. 1200 6th Avenue, Suite 1620 Seattle, WA 98101
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB
CONSTRUCTION RECORD DRAWINGS
SURVEYED:
DESIGNED:
STORM DRAINAGE REVISIONS AMT 09/20/2019 ACB DRAwN. AMT
1 ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS AMT 01 28 2019 ACB CHECKED:
BJS
NO. REVISION BY DATE APPR APPROVED:
WJF
SCALE:
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL NAD 1983/1991
DATU M
C4.3
ALTERNATE BID NO. 1 0
C4.2
KEYMAP
CITY OF
RENTON
Planning/Building/Public Works Dept.
PROPOSED LEGEND:
CONCRETE SIDEWALK 2
C4.3
ASPHALT CEMENT 1
C4.3
PLAN NOTES
1. PROTECT EXISTING CURBS AND PAVEMENT FROM DAMAGE
DURING CONSTRUCTION.
2. PROVIDE HOT TAR SEAL AT ALL JOINTS. COMPLETELY FILL ALL
JOINTS. (TYP.)
GRAPHIC SCALE
0 10 20 40
1" = 20 FEET
R-402822
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
McKNIGHT MIDDLE SCHOOL
FIELD IMPROVEMENTS
RENTON SCHOOL DISTRICT
GRADING, PAVING &
HORIZONTAL CONTROL PLAN
DATE:
1/15/2019
PAGE
C4.2
SHEER OF.22
3 2
O
N
LO
0
00
T
�
u
co
O
O
O
00
1
z
O
Q
O
z
w
0
w
LL
Q
J
J
O
O
U
U)
J
0
0
2
/2
V
z
U
O
N
LO
O
O
00
T
Iql-
O
O
O
M
W
cry,
n
Z
O
O
Z
W
rY
VJ
J
W
H
Q
J
n
J
O
O
U
w
J
r)
0
Z
U
00
N
O
W
I—
z
O
I—
O
z
W
�rr,
V )
0
I
W_
H
a
J
n
J
O
O
2
rC)
V )
W
J
0
0
2
0
z
CU
G
Ln
_m
N
W
a
z
Ld
Know what's below.
Call before you dig.
Kl`�CEYtxTn €FOR SEPARATi�I Ki09i
iW+ xTT1Eu' "TRENCryPER-$`00--vm ..
.l,iCIdlllu.¢��71ON 9-332{1)
U6
= rrluv. t r
a • t,:
PUBLIC;WORKS
DEPARTMENT
W
s&l
W
PERFORATED STUD
-CONNECTION.
PERFORATED STUB -OUT
CONNECTION
NOT TO SCALE
�i�0;$i1�A1ti ITS FS �ittlP
tea=
AS-BUILT"'� ■_
I CERTIFY THAT THE INFORMATION SHOWN HEREON �`SSIrONAL
WHICH WAS AS -BUILT BY AHBL , AND MAY INCLUDE 1/07/2019
LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND
AS -BUILT COMMENTS, ACCURATELY REFLECTS EXISTING -I--
ALTERATKN OF THIS DMENT SHALL INVALIDATE THE Hj B] L
FIELD CONDICTIONS AS DETERMINED BY ME OR UNDER MY PROFESSIONAL SEAL 90SKNATURE.PUBIICATINOF
THIS DOMWENT DOES NOT DEROGATE FRON RESERVED
DIRECT SUPERVISION ON THIS DATE: 11/7/2019. OIIINERSHIPMITTSNIT'TMISDWAENTISFORUSE TACOMA SEATTLE•SPOKANE•TRI-CITIES
ONLY FOR THE PRO,ECT IDENTIFIED N THE ITTIE BLOCK
AND IS NOT TO BE USED FOR REPAIR, RENODEL OR
AHBL PROJECT NO. 2180059 ADOITI N TO THAT PRQECT OR FOR ANY OTHER PRQECF. 1200 6th Avenue, Suite 1620 Seattle, WA 98101
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB
EE: i+Kx 1d
>
T._ +
1, 1 t M NI,
N.I
'h"f$V�I=#FiR011i�i�SY$SEf�1 SFTOiT��0L1IfF.
DESTGNS--f DR'FLOW� &4CKU�` SVSTEF+LA�A�
PARALL' �L` 7AN�SS,�HOWN_DA!SHER
a -Du rrPEz:cs sal Mf%t
MR MRMILAM12"
(SAME SIZE. AS WLET'PIPE,
11'r MIN, CIA.
1`J.011 GRADE
_ -,01A AftVEHfPJP
V*—U*P T_p_ TAW_(l'.E4UIRIj-0
IF NO'_ACCESS_RISER PNT4NK)
'`t o
"SEE Nbif :`t4 ftfk$
"OTES:
TH19,13 TAJi(I&P- CFIEMA'TYC,! EPRESENT•NTIPN C =`f�G 1TAi `C47 FNiUR 7PDN WlIk.'VAF Y!PEPENOING OFFSPECIF,}IC$IT�, �`,(]N$TRhINT>�," ND
APPL'ILLE.DESIGN CRITERW>
7, MI
t MET,7kl,--.P,ARTS(aREE-[3RECiT ,BE£iA`iNL€$,{^TEEk..-'1,1LUMINIYElY�4',i'1=E6.{DBE%}LUMINk�M AL�b1THER.4T€ELPART ikMiS?i.6E.GA4V11NIZE0WITM
TREAI'MEr1'i�,31, �si>��.
ACCESS -:RISERS RELTLIIRETa;CENIEREffNa MORE :iNATTSq-FEE7
]FROM AN'r;LQCATfON.'P@fjHINT+jE_QEM34TR I K.
�? H40 LiVif LOA s NJST Of AbbOMMODA'RED-FOR TANKS] LYING'W ER' P f&AREMi. RCADWAY&. AN6A AwmA
$' SEWING 6177NE PIS SifALCT3ElNAI R_071NCE` 1lR STD PMM =40
) PRKAT sTAaTs ,DFrFN TnelKsr PAssEE:vs�
8, PI PE MATERIAL�:IOINTS� ANDPROTECTFVEt'T.REATMENT F4R TANKS SMALL OFJN.iACCORDANCE.WITH SECTIONS'7dk#'ANO 94510F THE WSDQT1AP-WA,
STANDARDSPECIFTCADON1
9; ALA. TANK ACCESS OPENINGS MUST B€READILY ACCESSIBEE 65GMAII4TENANCE A(ENICC€S
T& V4t'I6FJ CONNECTWG
NG TO P;I'F E%OIST�NC� PIPE! USE AA FABRICATED DANQ COLLAR tf X,i SAME MA kk CORRUGATED PSP€3GDAPiER QPjR— — -
CONNEC TING PIPE -- _
!I f.. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECTT Rf_OUIREMENTS! ORAYRING IS'N0T7 P�41.E" 17St,' A'/NLESS CITHERIVISE NO'1'EP,
PUBLIC WORKS - TYP-IC-€T = NTION TAavEal,
I, AL NK �/.�s/gym
DEPARTMENT' �_,.,��7J
TYPICAL DETENTION TANK
NOT TO SCALE
DETENTION
TANKS
DIA. IE
SOCCER 4.0' 0 342.25
BASE BID
ALTERNATE BID NO.1
L
CONSTRUCTION RECORD DRAWINGS
SURVEYED: SCALE: VERTICAL: NAVD 19W
AS SHOWN HORIZONTAL: NAD 1983/ 1991
DESIGNED:
STORM DRAINAGE REVISIONS AMT 09/20/2019 ACB DRAWN:
AMT
ONE INCH DATUM
1 ALTERNATE BID NO. 1: SOCCER FIELD IMPROVEMENTS AMT 01 28 2019 ACB CHECKED: AT FULL SCALE
IF NOT ONE INCH
NO. REVISION BY DATE A P P R APPROVED: SCALE ACCORDINGLY
WJF
"HOLkSSFPS_
6L9
�$ECTI4f�1',
1P)U4 WGASRkT-TO_EXCLUQEDIRT'
RISER 36' DIA. MIN:, SAME MAT€RW)LANO .
GAt1GF AS TANK MEIDEO Olf:�,*0-jC�TAPfi�;
DEFENTTON:TANK'
As:
1 us ADJu5TING lmOCKSXS RECt17IRETriQT3R1NO FRAAI&"1'O OMEJ.
_Z METAL PARTS PREFERRED TO 9L_' STAINLESS ST'EEILACWWIN[ZFFU3'STE-EL OR_ALU[MINLMA. ALL{7TH.ER STEELPARTS
MUST OF IGALVAN{ZEDP)TR €REATMENT$ H '2;bR'9�
a MUST BE LOCATTtO FO_R_ACCESS {9Y-MAtNTENA�CEV_E S;
�#. MAY'511&S76fUjE WSD{*T.SPECIAL`TjIP€ LV �aAAfilF1 SPCA
',. '1'3 P SLAS SMALL`BP.RA-Mo FOIR HS=xL01AD.INC,S
Bw AWGFYWE RIfIGS AF1m CA5i 1GSSNA4t 99 MORTAR WAGCORD7U3CELVFfFTS7AIVDANI3 $RECIFIDR7K7N.?fA
UNtE59 RTHER WISE-NOTEO',`6RAYfStNCi IS NaTTGt�CAIE-{NT.S}'I
PL)BLiCVVORKS --- - PNDvea, _-
DETENTfON TANK ACCESS
'0FPARTMF:T fl 8!
k wansaeMariar 'd?'',
DETENTION ACCESS
NOT TO SCALE
CITY OF
RENTON
Plonning/Building/Public Works Dept.
R-402824
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
McKNIGHT MIDDLE SCHOOL
FIELD IMPROVEMENTS
RENTON SCHOOL DISTRICT
DRAINAGE NOTES AND DETAILS
DATE:
1/15/2019
PAGE:
C4.4
SHEET: 2OF:
4 32
O
N
Ln
O
co
T
�
u
C)
C)
0
co
o�
z
O
Q
O
z
w
0
J
W
H
Q
J
0-
J
O
O
U
w
J
0
0
/2
V
z
U
5
00
N
O
0
W
z
O
Q
O
z
w
0
J
W
ILL
n
J
O
O
0
c
LU
li)
I5
L
I-
l/r
V
z
U
� / ••••••• W W W W W W W W W /d W W W/ W/ W W W W /W W W W �{✓ � � /\IV I
'
NG FENCE, TYP.
'.'.
o ' W W W W W/ W W W W W W W/ W W W W / W W W W/ +✓ W W W W W W\ W W W W `
/• •I•J• •• W lW W W W /G W L W W /W W W W W W W .y / W W W W/ W W W W / W W W\ W W W •::.`
/Wj W W W W/ //W/ /Wj //� 7Y W �� W W W
W\ W/ 6 W W W /W/ W W W W/ W W W W �✓ W W W /W W W W/ 6 W/ W/ W\ W W W W \W W * W .;.;•.`
.. W W, W \ W/ W W W W Y W W W / W W W W W W W/ W W W/ W W W W / W\ W W \� W W \ W W \\ W .................
.'.. `
/.:.::::: �/ / .....
.y W \`/�\�,/, \ W W W/ W W W /W �y W W W\ W W W W
o ' �. W W W W W /W W -''�''•'•''''•'•''''•'•';;
' /,•,•,•..... .'. '.... W W W W W W \ W W W
/:':':':':•:•:•:•:••:: W W W W W W A�/ W W W W W W W W W W W W W W W /W/ W W W W /W 44//�� W W\ W W W W W I W W W W W \
...,.,.,.` \
' \�.1 C'.'.': .'.'.'.'.'•..•.. L W W W W W W W W W/ ,Y W W W/ W W W /W / W W W �\ W W W W/ W W W / W W W \ W W \ W W W W (` W\ W W\ W W \ \
// W
W W W W W W W W W W W W f// •.'.'.`
W ' ' •• •'•'•'•'•'•" W\W\J FWTBAW W/CWD L
`
•'•'•'': ..'.. .•....
y✓ PQRT NIXW WW W �..
W \V,
W W W •'•'•'•'• .
\
,I
'
W\ W W W W\ W W w W W •'_••
W/ �✓ W W W �/ W W W W/ W W W \ W/ � W\ W W \\
W W W W JV W W W W/ W W W W W W W W W W/ W W W W /G W W W W/ W W W W /�\\\ W W\ W W ` W W W W \ W W W W W W W \ W\ W W W W W
W W
W
W W W W W yr/ W W W W /W/ W W W 6 /� W W W/ W W W W W ` `✓ W 41 W W /W W W W/ W W W W W� W W W W W� W \ W W \W
' W W W W/ W W W �✓ /W W W W/ j/ W W W/ W W W �W W W W W W (/ W/ W W W/ W W W W// W' W W W W \\ \W
IV
' /W/ W W W W �4�/ W W W W/ W W W W /W W W W W W �L/ W W W /W W W W / W �L W W W \W W W\ W W \ W W W W W\ W W\ W W\ W W W W
\ W W \L W W W\ W W\\ W W \ W W \ W W W W W W\ W W\ W W
I ' W W/ W W/ y✓ /W W W W / W W W W W W/ /W W/ W W W W /W W WJ�j Ji W W W W /W W/ W W W W / / \ W W \ W W \ W \W W W W W\ W W\ W W \ W W \W W y� W 4\ W
JY / W W W /W/ W W W W /W/ W W W �I✓ W W W W/ \W W W W W C u✓ W W W W/ / / / W W\ W W \ W W \W W \W W W W W\ W W\ W W \ W W \ W W \W W
W\ W \ W W \ W W \ W W W W W W W\ W W \ W
W W W W W \ W W W W \W W W W\ W W W W W
JV / y✓ /// \\ \ W \ W W W W W \ W W\ W W\ W W W W \ W W � W �V W �
' ./•' W W �`W W W W �L/ W W W / W W W W/ W / W W �Y' / W W W W/ W W W W /Q� W W W /
.... W W W/ �✓ W W W /W W W W/ 9� W W W JC / W /J W W/ W W W /Y/ W W W W W W W W W W
' ...••• W W W W rW W W /d W W W W/ W W W W /W W W W W/ W W W W /W W W W 'w W W W W W W W W' W / \ W W �Y W W W W\ W W W W W W \W W W W
/•'''''' / / / / / / / / / () REPLACEMENT BENn S- \ \ \ \ \ \ I I
...... 2
0410CACE MOUNT r*Ki / W 'W/ W W W �/ W W W 1-�W W W W/ -',1, W W /W / W W W W
W W W W W �� W W W /W/ W W W W /W W W W �✓ /W W W W/ W W W W /� W W W/W/ W W W W
WVL W /W ICU W W/ N W W W y4 / W W W W/ W/ W W W W /W W W W )✓
W `\W W� W W W W W W W/ W W W W �Y W W W LW/ W W W W /W W W W y✓ W W W W/ W W �
X
CONCRETE PAD PER / \ \ \ \ W �\ W W \ W j11' \ W W \W W \W W .� W/
C\// MANUFACTURER'S /'y'�1/
W W 110 i V INSTRUCTIONS. SEL/VI/V IL \W \ \ \ W \\ W W W\\ W W W\W W W W W W\ W W W\ W W�
y CONCRETE PAQEYffTAI .
y.
` W \W W W W\ W W W �/` W W �� W W W W /Q W / W W W/ W W W W /W W A W / -��\`\ / / 1 \ \ `�( ...
w W \ W �{` W may[ W W W W/ W W W W �Y' W W W W/ / / j/ ,\ \ W W W W W \✓WV r
.......'''I'.
/
W W W W\ W W W I W \ W W W Y W \ W W //W / W W W �✓ W W W W // W / / \ �/ / / \ \ W� W W W.:.:.:.::::::::::
0 %•••••• ••••••
W W \W W W \ W W\ W W W 6uOF YBAL �q. ILLD W W \y` �\ W W W /W/ W W / / / l./ I \ \ ................
• • ......
: ••••••: ••••••: ••••••: ••••••
` I W\ W W W W \W W W W `� W SPORT"MI/� W\
V
/�f
\W
W\ W
A\
\�\W\\
W W W W\ "I'W W \ W W W W W W W\
W
" j
W\ W W \ W W \ W \L \ W �✓ W �G\ W W\ W W \ \ W \ W W \\W W � \ \ \ \ `\ \
4, 41
W \ W W JJ�
W W\ W W W W W W\W W W W\ W\\\ *Q�
NOTES
v ,71
1. SEE L1.1 AND 1-1.2 FOR PL ND
SCHEDULE.
Know what's below.
Call before you dig.
lowp Doti c
7 EX P . 03i
c,q PE ARG
11.07.2019
LEGEND
EXISTING TREE ■
■1�
_ 1
ALTERATION OF THIS DOCUMENT SHALL INVALIDATE THE
PROFESSIONAL SEAL AND SIGNATURE PUBLICATION OF
THIS DOCUMENT DOES NOT DEROGATE FROM RESERVED
OINJERSHIP RIGHTS IN IT. THIS DOCUMENT IS FOR USE T A C O M A • SEATTLE • SPOKANE •TRI-CITIES
ONLY FOR THE PROJECT IDENTIFIED IN THE TITLE BLOCK
AND IS NOT TO BE USED FOR REPAIR, REMODEL OR
ADDITION TO THAT PROJECT OR FOR ANY OTHER PROJECT. 1200 6th Avenue, Suite 1620 Seattle, WA 98101 NO.
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB
MATCH LINE- SEE L1.1
CONSTRUCTION RECORD DRAWINGS
ALTERNATE BID NO 1: SOCCER FIELD IMPROVEMENTS I AG 1 1/28/19 1 KG I suRvErm:
DESIGNED:
DRAWN:
MS
CHECKED:
KG
REVISION BY DATE APPR APPROVED'
J. Morse
SCALE
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERnCAL• NAVD 1988
HORIZONTAL- NAD 1983/1991
DATU M
:...........'....'........'
::...:...:...:...:...:...:...
...::::::::::::::::::::.....................................................
G� -y CITY OF
RENTON
Planning/Building/Public Works Dept.
GRAPHIC SCALE
0 10 20 40 FEET
1" = 20 FEET
KEYMAP
R-402825
I I IN COMPLIANCE WITH CITY OF RENTON STANDARDS
McKNIGHT MIDDLE SCHOOL FIELD IMPROVEMENTS
RENTON SCHOOL DISTRICT
BASE BID PLANTING PLAN
DATE
11/07/2019
FIELDBOOK:
PAGE
DRAWING NO:
L1.0
SHEEr. OP
0
N
O
W
T
61
MATCH LINE- SEE L1.0
00
N
i
0
LU
z
_O
Q
O
z
LU
IZ
J
LU
ILL
Q
J
n
J
O
O
17
LU
0
C�
G
r=
_V
z
U
�4, W'1'
\W_W_\W_\WW\�
W W
` W\ W
W W W \
W \\ W W\
W \ W
W\ W
TURF y
SLOPE PER PLAN TOP SAND MIX
\ A
2" ROOT ZONE
\�
\�
SLOPE
2" BASE SAND
W W W
\
W W\
SUBGRADE
TO MATCH
— III —III —III —III
FINISH
INCORPORATE 2" BASE SAND
\
GRADE
FULLY 4" INTO SUBGRADE
SECTION GRADED SUBGRADE SCARIFY TO
AN 8"-10" DEPTH AFTER GRADING
\ W
W W\
AND COMPACTION
\
` IV\
41
NOTES:
`
�"
1. SEE SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
`
'00
i
D,_SLAND-BASED FIELD
1 1/2" = 1'-0"
NOTES:
1. TREES PLANTED TOO DEEP WITHOUT EXPOSING ROOT FLARE WILL BE
REJECTED AND SHALL BE REMOVED AND REPLANTED AT PROPER DEPTH.
2. REPLACEMENT OR REPLANTING OF REJECTED TREES WILL BE DONE AT THE
CONTRACTOR'S EXPENSE.
3. REMOVE EXCESS SOIL THAT MAY HAVE ACCUMULATED ABOVE THE TRUNK
FLARE PRIOR TO DIGGING AT NURSERY. EXPOSE AND LOCATE TRUNK FLARE
PRIOR TO PLANTING.
4. PRUNE ANY GIRDLING OR ADVENTITIOUS ROOTS PRIOR TO BACKFILLING.
TRUNK FLARE
BOTTOM OF TRUNK FLARE.
LOCATE BOTTOM OF TRUNK FLARE 1" MIN
ABOVE ADJACENT FINISH GRADE.
MULCH LAYER, HOLD OFF
FROM TREE TRUNK
FINISH GRADE
REMOVE WIRE BASKET (NO
EXCEPTIONS) AND ANY
��/��/%\
OTHER SYNTHETIC MATERIAL
///\/
FROM ROOTBALL. CUT BACK
AND REMOVE BURLAP FROM
II I II I II I II I II I II I II I II I
II I II I II I II I II I II I II I II
TOP AND SIDE OF ROOTBALL.
SET BALL ON COMPACTED
SOIL MOUND TO PREVENT
SETTLING.
ROOTBALL
1" = 1'-0"
P-2018-MCK-71
NOTE:
1. TREES NOT PLANTED IN CONFORMANCE
WITH THIS DETAIL WILL BE REJECTED BY
THE LANDSCAPE ARCHITECT.
REPLACEMENT OF REJECTED TREES
WILL BE DONE AT THE CONTRACTOR'S
EXPENSE.
AT TIME OF PLANTING, TRIM
DAMAGED BRANCHES.
3" MULCH. NO MULCH AGAINST
TRUNK
3"-4" HIGH WATERING RING
SCARIFY SIDES OF PLANTING PIT
BACKFILL WITH EXISTING SOIL —
DO NOT DISTURB SUBGRADE —
BELOW ROOTBALL TO REDUCE
SETTLING.
DECIDUOUS TREE PLANTING 3X ROOTBALL
3/8" = 1'-0"
GENERAL LANDSCAPE NOTES
Qg ��
STAKE TREE WITH TWO 2"X2"X8'
STAKES SPREAD ACROSS FROM
EACH OTHER
APPROVED TREE TIE MATERIAL
SET LOOSE TO ALLOW FOR
TRUNK GROWTH
DRIVE STAKES AT
ROOTBALL EDGE
PI ANT SC;HFnt 11 F Al TFRNATF NC) 1
DRIVE STAKES 6"-12" INTO
UNDISTURBED SOIL BELOW UGRD
LS LIQUIDAMBAR STYRACIFLUA
ROOTBALL
P-2018-MCK-70 VERS CODE BOTANICAL NAME
1. SEE SPECIFICATIONS FOR PLANT MATERIAL, TOP SOIL AND PLANTING MIX TYPES AND DEPTH, SOIL AMENDMENTS, FERTILIZERS
AND WARRANTEES.
2. PLANTING SHALL CONFORM TO ALL CITY OF RENTON CODE REQUIREMENTS.
3. CONTRACTOR SHALL VERIFY ON -SITE CONDITIONS PRIOR TO BIDDING AND CONSTRUCTION.
4. SEE DRAWINGS L2.00-L2.4 FOR IRRIGATION PLANS.
5. THE CONTRACTOR AND OWNER ARE RE FOR READING THE PLANS, SPECIFICATIONS AND NOTES.
7. THE CONTRACTOR SHALL FURNISH �p YDROMULCHES.
8. SEE THIS SHEET FOR PLANTING o.R. sk,
9. ANY AND ALL AREAS DISTURBE �N� 10 IES SHALL BE REPAIRED TO THEIR PRE -CONSTRUCTION STATE OR
BETTER. /�
Know what's below.
Call before you dig.
coo NAM
2 �\ ALTERATION OF THIS DOCUMENT SHALL INVALIDATE THE
OS 7 EX P . 03i �� PROFESSIONAL SEAL AND SIGNATURE PUBLICATION OF
J ` THIS DOCUMENT DOES NOT DEROGATE FROM RESERVED
c P E A R G OINJERSHIP RIGHTS IN IT. THIS DOCUMENT IS FOR USE T A C 0 M A SEATTLE • SPOKANE •TRI-CITIES
ONLY FOR THE PROJECT IDENTIFIED IN THE TITLE BLOCK
AND IS NOT TO BE USED FOR REPAIR, REMODEL OR
ADDITION TO THAT PROJECT OR FOR ANY OTHER PROJECT. 1200 6th Avenue, Suite 1620 Seattle, WA 98101
11.07.2019 1206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB
MATCH LINE- SEE L1.2
AMERICAN SWEET GUM
COMMON NAME CONT SPACING QTY
LH LAWN MIX HYDROSEED HYDROSEED - LAWN HYDROSEED 50,240 SF
W W
W W SL SAND BASED FIELD - GREEN SPORT HYDROSEEDED - GREEN SPORT MIX HYDROSEED 60,011 SF
CONSTRUCTION RECORD DRAWINGS
1 ALTERNATE BID NO 1: SOCCER FIELD IMPROVEMENTS AG 1/28/19 KG SURVEYED: SCALE VEffn_
HORIZONTAL- NAD 1983/1991
DESIGNED: AS SHOWN
DRAWN:
MS ONE INCH DATUM
CHECKED: AT FULL SCALE
KG IF NOT ONE INCH
NO. REVISION BY DATE I'APPR APPROVED: SCALE ACCORDINGLY
J. Morse
t*w
RENTONCITY OF
Planning/Building/Public Works Dept.
u
GRAPHIC SCALE
0 10 20 40 FEET
1" = 20 FEET
KEYMA
0
J
P ILL
LU
}
Q
J
R-402826 _j
0
IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0
McKNIGHT MIDDLE SCHOOL FIELD IMPROVEMENTS
RENTON S O DISTRICT
BASE AND ALTERNATE NO. 1
PLANTING PLAN
2
U
W
0
C0
G
=
R
DATE
11/07/2019
FIELDBOOK:
PAGE
v_
z
DRAWING NO:
L1.1
5�
G
SHEET:OP
26 32
00
N
O
0
W
z
O
Q
O
z
W
IIr
0
W
LL
Q
^J
n
J
O
O
U
W
I
0
C0
G
rr
_V
z
V
CU
G
m
Know what's below.
Call before you dig.
BID ALTERNATE
NTING PLAN: ALTERNATE NO. 1 NE 12TH ST.
MAI
Y
rAnm
N
J
W
LU
z
J
2
U
H
Q
NE 12TH ST.
1
1
1
1
1
LEGEND
NOTES
EXISTING TREE
FENCING/ROOT PROTECTION
FEEDER ROOT ZONE
DIA=2X
1. FENCING TO BE PROVIDED AND MAINTAINED AT CANOPY DRIP LINE.
2. TREE PROTECTION FENCE SHOULD BE MAINTAINED THROUGHOUT GRADING AND
DRIP LINE
CONSTRUCTION AND SHALL NOT BE REMOVED UNTIL FINAL ACCEPTANCE.
DIA=X
3. ALL BRUSH CLEANUP WITHIN DRIP LINE SHOULD BE COMPLETED BY HAND TO
Q
PREVENT DISTURBANCE OF NATIVE GROUND COVERS.
J
4. NO WIRES, CABLES, OR OTHER DEVICES SHALL BE ATTACHED TO PROTECTED
g
Q
TREES DURING CONSTRUCTION.
Q
5. CONTRACTOR SHALL REFER TO RENTON CODE FOR MORE INFORMATION.
� Q
PLACARD READIN
TRENCHING/EXCAVATION
Q
"NO
p
TRESPASSIN(3'-
CRITICAL ROOT ZONE
Qg
PROTECTED
TREES" 50' O.C. O
1. NO DISTURBANCE ALLOWED WITHOUT SITE -SPECIFIC INSPECTION AND APPROVAL
Q
OF METHODS TO MINIMIZE ROOT DAMAGE.
1/PER TREE.
CHIAN LINK
DRIP LINE
CONSTRUCTION
1. LANDSCAPE ARCHITECT'S APPROVAL REQUIRED FOR USE/ACCESS WITHIN DRIP
FENCING, TYP.
LINE.
2. NO SOIL DISTURBANCE OR ACTIVITY ALLOWED WITHIN FENCED AREAS, SUCH AS
MATERIAL STORAGE/STOCKPILING, PARKING, EXCAVATION, DUMPING OR WASHING.
POST 8' OC MAX
3. ANY TRENCHING SUBJECT TO FIELD INSPECTION AND APPROVAL BY LANDSCAPE
ARCHITECT.
SPACING. INSTALL
AT A MIN. OF 2'-0"
FEEDER ROOT ZONE
BELOW GRADE OR
1. OPERATION OF HEAVY EQUIPMENT AND/OR STOCKPILING OF MATERIALS SUBJECT
PROVIDE STABLE
TO LANDSCAPE ARCHITECT'S APPROVAL.
FENCING FEET.
2. MINIMIZE TRENCH WIDTH WHEN USING HEAVY EQUIPMENT. SURFACE PROTECTION*
MEASURES MAY BE REQUIRED.
3. LIMIT ANY DISTURBANCE TO MAXIMUM 1/3 OF FEEDER ROOT ZONE.
4. IF ROOTS GREATER THAN 2 INCH FOUND OUTSIDE OF FENCING, PROTECT BY HAND
EXCAVATION AND, IF NECESSARY, CUT CLEANLY AND KEEP MOIST.
ELEVATION
5. USE 3 INCHES OR DEEPER WOOD CHIP MULCH OUTSIDE FENCED AREAS TO
>L
PROTECT FEEDER ROOTS.
CRITICAL ROOT ZONE
DIA=1/2X
*SURFACE PROTECTION MEASURES
6-8" MULCH LAYER, 3/4"PLYWOOD, OR STEEL PLATES
TREE PROTECTION
3/16" = V-0"
1. SEE L1.1 FOR PLANTING NOTES, DETAILS AND PLANT SCHEDULE. ALL AREAS SUBJECT TO CLEARING AND GRADING THAT HAVE NOT BEEN COVERED BY IMPERVIOUS
2. SEE CIVIL DEMO PLAN FOR TREE REMOVAL SURFACE, INCORPORATED INTO A DRAINAGE FACILITY OR ENGINEERED AS STRUCTURAL FILL OR
2.1. NUMBER OF TREES TO BE REMOVED: 2 SLOPE SHALL, AT PROJECT COMPLETION, HAVE A TOPSOIL LAYER WITH A MINIMUM ORGANIC MATTER
TE RNATE N O. 1 CONTENT OF 5% DRY WEIGHT AND A PH FROM 6.0 TO 8.0. THE TOPSOIL LAYER SHALL HAVE A
2.2. TREES TO BE REMOVED ARE LESS THAN 90% OF TOTAL MINIMUM DEPTH OF EIGHT INCHES. SUBSOILS BELOW THE TOPSOIL LAYER SHALL BE SCARIFIED AT
SIGNIFICANT TREES. LEAST 4 INCHES WITH SOME INCORPORATION OF THE UPPER MATERIAL TO AVOID STRATIFIED
410 LAYERS.
11 O
�r
Z0S 7 EX
c,q PE A, ?-0
11.07.2019
W
z
GRAPHIC SCALE
0 10 20 40 FEET
1" = 20 FEET
KEYMA
O
N
O
00
T
LJ
co
C)
C)
CD
06
P-2018-MCK-73 J
O
IN COMPLIANCE WITH CITY OF RENTON STANDARDS O
1�
CONSTRUCTION RECORD DRAWINGS
_ 1 ALTERNATE BID NO 1: SOCCER FIELD IMPROVEMENTS AG 1/28/19 KG SURVEYED: SCALE
_ vERncAL: w,w 1988
AS SHOWN HORIZONTAL- NAD 1983/1991 Gti�
DESIGNED: �� CITY OF McKNIGHT MIDDLE SCHOOL FIELD IMPROVEMENTS
RENTON SCHOOL DISTRICT
■ ALTERATION OF THIS DOCUMENT SHALL INVALIDATE THE DRAWN: RENTON
MS �'
PROFESSIONAL SEAL AND SIGNATURE PUBLICATION OF THIS DOCUMENT DOES NOT DEROGATE FROM RESERVED ONE INCH DATUM ALTERNATE N . 1
OINJERSHIPRIGHTS IN11THIS DOCUMENT ISFOR USE TAC0MA•SEATTLE•SPOKANE•TRI-CITIES CHECKED: AT FULL SCALE Planning/Building/Public Works Dept.
ONLY FOR THE PROJECT IDENTIFIED R IN THE TITLE BLOCK IF NOT ONE INCH PLANTING PLAN
AND IS NOT TO BE USED FOR REPAIR, REMODEL OR
ADDITION TO THAT PROJECT OR FOR ANY OTHER PROJECT. 1200 6th Avenue, Suite 1620 Seattle, WA 98101 NO. REVISION BY DATE AP P R APPROVED' SCALE ACCORDINGLY
206.267.2425 TEL 206.267.2429 FAX www.ahbi.com WEB J. Morse
U
cn
W
0
0
2
=
R
DATE
11/07/2019
FIELDBOOK:
PAGE
v_
z
DRAWING NO:
L1.2�
5y
G
SHEET. OP
00
N
O
1-
C)
0
LU
Z
O
\Q
O
Z
LU
��rr
VJ
0
LU
H
J
n
J
O
O
2
CU
LU
C0
G
Z
U
G
0
I
>E
I
I
I
C13 -
2"
� G
E5
D24 -
1 %4"
D23 -
�•
C8 -
1
- C7
1 %z"
=----M-----M----- -
2 - C6
1 %2"
E4 -
1" - D22
C9 - LIMIT OF WORK LINE
C5
- D21
2 C3
d1 %2" /
D20 -
o 1„
22 -
- D19
0
Ij1 °
® I,III, 11`I o
® p I-
i
_
ll(E 1
2"
1
IN
INKj
MODELNUMBER
Al• • 8200CR-XPR 1-1/2"
A ` ` 11
A3 WEATHERMATIC 8200CR-XPR
m.44 VVEAT-1- ::
►� . 1i-
AG VVEATHERIVIATIG 8200GR XPR
WATER MAINS DURII`
. 11
• ./I . .�//r /� / ` • 1 1
,,�/`' ♦ : `° it . . - ` 11 ..
l000
r/ DEMO MAIN LINE
:Ojo FROM THIS POINT
-ABEL AND CUT ALL . 11
WIRES r
/
/ •� ®, // f
/ OFA 0
OOA
0 Arm.
mvmI i �(Fj
BASE BID VALVES
0.41
B24
WEATHERMATIC 8200CR-XPR
1-1/2"
Cl
WEATHERMATIC 8200CR-XPR
1-1/2"
qvo 4� V/1
WEATHERMATIC 8200CR-XPR
2"
/�r
wo
//C2
/C4
WEATHERMATIC 8200CR-XPR
A
C5
WEATHERMATIC 8200CR-XPR
1-1/2"
0 -UK
C6
WEATHERMATIC 8200CR-XPR
1-1/2"
C7
WEATHERMATIC 8200CR-XPR
1-1/2"
WEATHERMATICO4F
8200CR-XPR
F.00F,0
C9
WEATHERMATIC 8200CR-XPR
1-1/2"
Clo
WEATHERMATIC 8200CR-XPR
Pr
�
: •
1,
`..
,. �
: �
.
.
: 11
o
�� �
•
: � : : : :
r
ii
lo
E 0
I
p
_
I _054
- •
����
�
�//ice i�iil�ii i �
: 11
Know what's beIow.
Call before you dig.
sc� PE A?' C,
11.07.2019
ALTERATION OF THIS DOCUMENT SHALL INVALIDATE THE
PROFESSIONAL SEAL AND SIGNATURE. PUBUCAT10N OF
THIS DOCUMENT DOES NOT DEROGATE FROM RESERVED
OWNERSHIP RIGHTS IN IT. THIS DOCUMENT IS FOR USE T A C O M A • SEATTLE • SPOKANE •TRI-CITIES
ONLY FOR THE PROJECT IDENTIFIED IN THE TITLE BLOCK
AND IS NOT TO BE USED FOR REPAIR, REMODEL OR
ADDITION TO THAT PROJECT OR FOR ANY OTHER PROJECT. 1200 6th Avenue, Suite 1620 Seattle, WA 98101
206.267.2425 TEL 206.267.2429 FAX www.ahbl.com WEB
1 AI TFRNATF Rin Nn 1 • .nr;r.FR FIFI n IMPRn\/FMFNTS I AG 1/28/19 KG SURVEYED: SCALE:
NO.
REVISION
DESIGNED:
DRAWN:
MS
CHECKED:
KG
BY DATE AP P R APPROVED:
J. Morse
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
ALTERNATE NO.1
UMBER
MODEL
1
WEATHERMATIC 8200CR-XPR
A
WEATHERMATIC 8200CR-XPR
A
WEATHERMATIC 8200CR-XPR
A
WEATHERMATIC 8200CR-XPR
A5
WEATHERMATIC 8200CR-XPR
A6
WEATHERMATIC 8200CR-XPR
A7
WEATHERMATIC 8200CR-XPR
A8
WEATHERMATIC 8200CR-XPR
A9
WEATHERMATIC 8200CR-XPR
A10
WEATHERMATIC 8200CR-XPR
A19
A20
A21
A22
A23
A24
B1
B2
B3
B4
B5
B6
B7
B8
B8
B9
B10
B11
WEATHERMATIC 8200CR-X
WEATHERMATIC 8200CR-X R
WEATHERMATIC 8200CR- R
WEATHERMATIC 8200CR- R
WEATHERMATIC 8200CR- PR
WEATHERMATIC 8200CR- PR
EATHERMATIC 8200CR PR
EATHERMATIC 8200C XPR
EATHERMATIC 8200C -XPR
EATHERMATIC 8200C -XPR
ATHERMATIC 8200 -APR
W ATHERMATIC 8200 R-XPR
W ATHERMATIC 8200 R-XPR
W THERMATIC 820 R-XPR
WE THERMATIC 820 CR-XPR
WE THERMATIC 82 CR-XPR
WE HERMATIC 82 OCR-XPR
WEA HERMATIC 82 OCR-XPR
B13
WEAT ERMATIC 8 OOCR-XPR
B14
WEAT ERMATIC OOCR-XPR
B15
WEAT RMATIC 200CR-XPR
B16
WEATH RMATIC 200CR-XPR
B17
WEATH RMATIC 8200CR -XPR
B18
WEATH MATI 8200CR-XPR
B19
WEATHE MATI 8200CR-XPR
B20
WEATHE MATI 8200CR-XPR
B21
WEATHE AT C 8200CR-XPR
B22
WEATHER A C 8200CR-XPR
B23
WEATHER A IC 8200CR-XPR
B24
WEATHER IC 8200CR-XPR
Cl
WEATHERM IC 8200CR-XPR
C2
WEATHERM TIC 8200CR-XPR
C3
WEATHER TIC 8200CR-XPR
C4
WEATHER A IC 8200CR-XPR
C5
WEATHER A IC 8200CR-XPR
C6
WEATHER A C 8200CR-XPR
C7
WEATHE AT 8200CR-XPR
C8
WEATHE MATI 8200CR-XPR
C9
WEATHE MATT 8200CR-XPR
C10
WEATH MATI 8200CR-XPR
C11
WEATH RMATIC 200CR-XPR
C12
WEATH RMATIC 200CR-XPR
C13
WEAT ERMATIC OOCR-XPR
C14
WEAT ERMATIC 8 OOCR-XPR
C16
WEAT ERMATIC 8 OOCR-XPR
C17
WEA ERMATIC 8 OCR-XPR
C17
WEA HERMATIC 82 OCR-XPR
C18
WE HERMATIC 82 CR-XPR
C19
WE THERMATIC 820 CR-XPR
C20
WE THERMATIC 820 CR-XPR
C21
W THERMATIC 8200 R-XPR
D1
W ATHERMATIC 8200 R-XPR
D2
W ATHERMATIC 8200 R-XPR
D3
ATHERMATIC 8200C -XPR
D4
EATHERMATIC 8200C -XPR
D5
EATHERMATIC 8200C -XPR
D6
EATHERMATIC 8200CR XPR
D7
EATHERMATIC 8200CR PR
D8
WEATHERMATIC 8200CR- PR
D9
WEATHERMATIC 8200CR- PR
D10
WEATHERMATIC 8200CR- R
D11
WEATHERMATIC 8200CR-X R
D12
WEATHERMATIC 8200CR-X R
D13
WEATHERMATIC 8200CR-XP
D14
WEATHERMATIC 8200CR-XP
D15
WEATHERMATIC 8200CR-XP
D17
WEATHERMATIC 8200CR-XPR
D18
WEATHERMATIC 8200CR-XPR
D19
WEATHERMATIC 8200CR-XPR
D20
WEATHERMATIC 8200CR-XPR
D21
WEATHERMATIC 8200CR-XPR
D22
WEATHERMATIC 8200CR-XPR
D23
WEATHERMATIC 8200CR-XPR
D24
WEATHERMATIC 8200CR-XPR
E1
WEATHERMATIC 8200CR-XPR
E2
WEATHERMATIC 8200CR-XPR
E3
WEATHERMATIC 8200CR-XPR
E4
WEATHERMATIC 8200CR-XPR
E
WEATHERMATIC 8200CR-XPR
E
WEATHERMATIC 8200CR-XPR
WEATHERMATIC 8200CR-XPR
8
WEATHERMATIC 8200CR-XPR
9
WEATHERMATIC 8200CR-XPR
10
WEATHERMATIC 8200CR-XPR
E11
WEATHERMATIC 8200CR-XPR
VERTICAL: NAVO 1988
HORIZONTAL: NAD 1983/1991
DATU M
IRRIGATION SCHEDULE
SIZ
SYMBOL
MANUFACTURER/MODEL/DESCRIPTION
1-1 2"
1- /2"
REMOTE CONTROL VALVE TO REMAIN
2"
1 1/2"
REMOTE CONTROL VALVES TO BE REMOVED.
1 1/2"
-1/2"
0
RAIN BIRD 44-LRC
-1/2"
1" BRASS QUICK -COUPLING VALVE, TO REMAIN
1-1/2"
1-1/2"
V
RAIN BIRD 44-LRC
1-1/2"
1" BRASS QUICK -COUPLING VALVE, TO BE REMOVED
2"
IRRIGATION MAINLINE: PVC SCHEDULE 40-EXISTING
2"
NNN —
IRRIGATION MAINLINE: DEMO MAIN
1-ice'
Valve Callout
Valve Number
2
2"
# #
Valve Flow
2" # Valve Size
2
21; ® IRRIGATION DEMO AREA
2„
1-1/2"
2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2" VALVES TO BE REMOVED
1-1/2"
2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2" IRRIGATION DEMOLITION NOTES
1-1/2"
1.
DEMO ALL IRRIGATION WITHIN HATCHED AREAS
1-1/2"
1-1/2"
2.
LABEL AND CUT IRRIGATION CONTROL WIRES.
2
1-1/2"
3.
CUT AND CAP MAIN LINE AS MARKED ON THE PLAN
1-1/2"
1-1/2"
4.
SEE 1995 IRRIGATION AS -BUILD FROM SCHOOL FOR EXISTING IRRIGATION TO
1-1/2"
REMAIN.
1-1/2"
2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/4"
1-1/2"
2
2"
1-1/2"
2"
2ll
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1"
1-1/4"
2"
1-1/2"
1-1/4"
1-1/2"
1-1/2"
1"
1-1/2"
1-1/2" GRAPHIC SCALE
1-1/2"
1 0 25 50 100 FEET
1-1/2"
1-1/2"
1-1/2" 1" = 50 FEET
11
Ln
0
00
U
H
H
Z
O
\Q
O
Z
W
Ir
0
9--_I T7
1-1/"
KEYMAP
LU1-1/44"
LL
1"
1"
J
1-1/4„
R-402828
_j
11
O
1 1/2"
1 1/2"
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
O
1"
1- 4"
V
1-1 2"
(f�
1"
W
J
1„
1-1/2
0
1-1/2'
0
_y rCITY OF McKNIGHT MIDDLE SCHOOL FIELD IMPROVEMENTS
} °RENTON RENTON SCHOOL DISTRICT
Planning/Building/Public Works Dept.
IRRIGATION DEMO PLAN
DATE:
11/07/2019
=
R
FIELDBOOK:
PACE:
v_
Z
DRAWING NO:
L2.0
U
C
G
SHEET:OF:
28 3 2
00
N
O
W
z
O
a
O
z
w
rr
0
J
W
H
a
J
n
J
O
O
CU
w
J
r)
z
Y
U
0
0
0
00
04
Lill
I
a
NOTES
1. SEE L2.2 FOR IRRIGATION LEGEND.
2. SEE L2.3 FOR IRRIGATION DETAILS.
Know what's below.
Call before you dig.
LEGEND
EXISTING TREE
MATCH LINE- SEE 1-2.1
GRAPHIC SCALE
0 10 20 40 FEET
1" = 20 FEET
of WASH
PSG R . S kj/o
CONSTRUCTION RECORD DRAWINGS
■1I■
• 1 ALTERNATE BID NO 1: SOCCER FIELD IMPROVEMENTS AG 1/28/19 KG
DESIGNED: AS SHOWN HORIZOHORIZONTAL,NAD 11910971991
�
� O
Z �\ ALTERATION OF THIS DOCUMENT SHALL INVALIDATE THE - DRAWN:
O 7 I� PROFESSIONAL SEAL AND SIGNATURE PUBLICATION OF MS
S Ex P . �3 �� THIS DOCUMENT DOES NOT DEROGATE FROM RESERVED I ONE INCH DATU M
C n G OYMERSHIP RIGHTS IN IT. THIS DOCUMENT IS FOR USE T A C O M A SEATTLE SPOKANE TRI-CITIES CHECKED: AT FULL SCALE
�Y � � SECT �TM H � ¶� MM KG IF NOT ONE INCH
AND IS NOT TO BE USED FOR REPAIR, REMODEL OR SCALE ACCORDINGLY
ADDITION TO THAT PROJECT OR FOR ANY OTHER PROJECT. 2012i0.2425 TEL Avenue,
,Suite 1620
20FAX eat WA om WED NO. REVISION BY DATE AP P R APPROVED
11.07.2019 J. Morse
CITY OF
RENTON
Planning/Building/Public Works Dept.
4
q
q
I
III
KEYMAP
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
McKNIGHT MIDDLE SCHOOL FIELD IMPROVEMENTS
RENTON SCHOOL DISTRICT
IRRIGATION PLAN
DATE
11/07/2019
FIELDBOOK:
PAGE
DRAWING NO:
L2.1
SHEETOR 29 32
O
N
L0
O
O
CID
61
u
O
O
O
O
z
O
a
O
z
w
0
w
H
a
J
0—
O
O
2
U
w
0
C�
z
U
G
00
i
0
w
Z
O
Q
O
Z
W
Cl)
0
w
H
Q
n
J
O
O
U
Cl)
w
I
r)
C�
G
r2
_V
Z
V
CU
G
O
MATCH LINE- SEE L2.0
2" ZNA 12 \ / ASPHALT 07 1 I i ASPHALT
*01000,
1„ /
♦ � I / -' I L I
\
♦ - .2 r" %- -- -
I
♦ \ I 12
♦ \ 12 I.
♦ 2V2"
♦ \ 1 V4" '
/
IRRIGATION SCHEDULE
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
❑ 0 8 ❑ M n TORO 570Z-6P-PR 12 SERIES
Q T H TT TQ F TURF SPRAY, 6" POP-UP, WITH BUILT IN -RISER PRESSURE
REGULATOR. ALSO INCLUDES THE ZERO FLUSH WIPER
SEAL. 1/2" FEMALE -THREADED INLET.
❑ a a e TORO 570Z-6P-PR 15 SERIES
Q T H TT TQ F TURF SPRAY, 6" POP-UP, WITH BUILT IN -RISER PRESSURE
REGULATOR. ALSO INCLUDES THE ZERO FLUSH WIPER
SEAL. 1/2" FEMALE -THREADED INLET.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
07 TORO T7PSS-02
TURF SPORTS ROTOR, 5" POP-UP, ADJUSTABLE ARC
FROM 45-360, VANDAL AND ABUSE RESISTANCE. WITH
CHECK VALVE AND RUGGED DURABILITY FEATURES. 1"
INLET SIZE, NPT. STAINLESS STEEL RISER. NOZZLE FLOW
6.6-30.6 GPM
12 TORO T7PSS-02
TURF SPORTS ROTOR, 5" POP-UP, ADJUSTABLE ARC
FROM 45-360, VANDAL AND ABUSE RESISTANCE. WITH
CHECK VALVE AND RUGGED DURABILITY FEATURES. 1"
INLET SIZE, NPT. STAINLESS STEEL RISER. NOZZLE FLOW
6.6-30.6 GPM
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
WEATHERMATIC 8200CR-XPR
BRASS REMOTE CONTROL VALVE WITH PRESSURE
REGULATOR
0 RAIN BIRD 44-LRC
1" BRASS QUICK -COUPLING VALVE, WITH
CORROSION -RESISTANT STAINLESS STEEL SPRING,
LOCKING THERMOPLASTIC RUBBER COVER, AND 2-PIECE
BODY.
71 RAINBIRD TURFMASTER
© RAINBIRD TURFMASTER
© RAINBIRD TURFMASTER
�D RAINBIRD TURFMASTER
�E RAINBIRD TURFMASTER
0 WATER METER 4"
EXISTING
IRRIGATION LATERAL LINE: PVC SCHEDULE 40
IRRIGATION MAINLINE: PVC SCHEDULE 40-EXISTING
IRRIGATION MAINLINE: PVC SCHEDULE 40 - PROPOSED
PIPE SLEEVE: PVC SCHEDULE 40
Valve Collout
Valve Number
# Valve Flow
# " Valve Size 0 F WAS y
R . S
fl ��
Know what's below.
Call before you dig.
O �O�' P
S EXP.0.05 ��
c q P E P\
11.07.2019
PSI
30
all
PSI GPM RADIUS
60 8.10 48'
60 12.7 53'
07
%'
\ 12ll 12
00000, i
2V2"
Al 63.5
• Al 76.2
211
A2 63.5 �`' J
2V2" 211
i� o
VALVE SCHEDULE
NUMBER
MODEL
SIZE
TYPE
GPM
PRECIP
Al
WEATHERMATIC 8200CR-XPR
2"
TURF ROTOR
76.20
0.45 in/h
A2
WEATHERMATIC 8200CR-XPR
2"
TURF ROTOR
63.50
1.92 in/h
A3
WEATHERMATIC 8200CR-XPR
2"
TURF ROTOR
63.50
0.85 in/h
A4
WEATHERMATIC 8200CR-XPR
2"
TURF ROTOR
63.50
0.85 in/h
A5
WEATHERMATIC 8200CR-XPR
2"
TURF ROTOR
50.80
2.13 in/h
A6
WEATHERMATIC 8200CR-XPR
2"
TURF ROTOR
63.50
0.45 in/h
A7
WEATHERMATIC 8200CR-XPR
2"
TURF ROTOR
63.50
1.02 in/h
A9
WEATHERMATIC 8200CR-XPR
2"
TURF ROTOR
72.90
0.57 in/h
A11
WEATHERMATIC 8200CR-XPR
2"
76.20
0.49 in/h
Al2
WEATHERMATIC 8200CR-XPR
2"
TURF ROTOR
63.50
0.84 in/h
NOTES
1. SEE L2.2 FOR IRRIGATION LEGEND.
2. SEE L2.3 FOR IRRIGATION DETAILS.
LEGEND
( D. EXISTING TREE
1��
a
ALTERATION OF THIS DOCUMENT SHALL INVALIDATE THE
W
PROFESSIONAL SEAL AND SIGNATURE. PUBLICATION OF
THIS DOCUMENT DOES NOT DEROGATE FROM RESERVED
011NERSHIP RIGHTS IN IT. THIS DOCUMENT IS FOR USE
TA C O M A • SEATTLE • SPOKANE •TRI-CITIES
ONLY FOR THE PROJECT IDENTIFIED IN THE TITLE BLOCK
AND IS NOT TO BE USED FOR REPAIR, REMODEL OR
ADDITION TO THAT PROJECT OR FOR ANY OTHER PROJECT.
1200 6th Avenue, Suite 1620 Seattle, WA 98101
206.267.2425 TEL 206.267.2429 FAX www.ahbl.COm WEB
07 1%4" 07 i �I 2",
I
II I
II I
I I
- o
I I I I
01 M M pin
I �
CRITICAL ANALYSIS
Generated: 2018-07-18 17:11
P.O.C. NUMBER: 01
Water Source Information: EXISTING
9[iIN%NT/_11W_1:312
Water Meter Size:
4"
Flow Available:
375.00 gpm
PRESSURE AVAILABLE
Static Pressure at POC:
90.00 psi
Elevation Change:
5.00 ft
Service Line Size:
6"
Length of Service Line:
20.00 ft
Pressure Available:
88.00 psi
DESIGN ANALYSIS
Maximum Station Flow:
95.99 gpm
Flow Available at POC:
375.00 gpm
Residual Flow Available:
279.01 gpm
Critical Station:
20
Design Pressure:
60.00 psi
Friction Loss:
5.11 psi
Fittings Loss:
0.51 psi
Elevation Loss:
0.00 psi
Loss through Valve:
3.10 psi
Pressure Req. at Critical Station:
68.71 psi
Loss for Fittings:
1.11 psi
Loss for Main Line:
11.09 psi
Loss for POC to Valve Elevation:
0.00 psi
Loss for Backflow:
0.00 psi
Loss for Water Meter:
1.00 psi
Critical Station Pressure at POC:
81.91 psi
Pressure Available:
88.00 psi
Residual Pressure Available:
6.09 psi
CONSTRUCTION RECORD DRAWINGS
1 ALTERNATE BID NO 1: SOCCER FIELD IMPROVEMENTS AG 1/28/19 KG SURVEYED: SCALE:
VERTICAL: NAVO 1998
AS SHOWN HORIZONTAL: NAD 19av 1991
DESIGNED:
DRAWN:
MS ONE INCH DATUM M
CHECKED: AT FULL SCALE
KG IF NOT ONE INCH
NO. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY
J. Morse
CITY OF
ME
RENTON
tiT
Planning/Building/Public Works Dept.
EXISTING IRRIGATION TO BE REMOVED,
TYP.- SEE 1995 AS-BUILTS, AVAILABLE
FROM SCHOOL DISTRICT
EXISTING IRRIGATION TO REMAIN, TYP.-
SEE 1995 AS-BUILTS AVAILABLE FROM
SCHOOL DISTRICT
SPRAY HEAD, TYP.
GRAPHIC SCALE
0 10 20 40 FEET
1" = 20 FEET
0
IUD
00
16
O
O
O
1
06
Z
O
Q
O
Z
w
LL
_ � 0
J
KEYMAP 1
Q
J
d
R-402830 0
IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0
McKNIGHT MIDDLE SCHOOL FIELD IMPROVEMENTS
RENTON SCHOOL DISTRICT
IRRIGATION PLAN
2
U
C )
W
0
0
I-
=
' R
DATE:
11/07/2019
FIELDBOOK:
PAGE:
v_
Z
DRAWING NO:
L2.2
SHEET: OF:
30 32
MATCH LINE- SEE L2.1
00
N
O
0
LU
z
O
Q
O
z
LU
IIr
0
J
LU
LL
Q
n
J
O
O
U
J
0
C0
G
rr
_V
z
V
CU
G
0
LO
0
0
00
N
N
N
J
L
LU
c1
Know what's below.
Call before you dig.
REPLACE ZONE
EXISTING ZOf
G R. SK A
� O
5
�6S EXP.03i0 ��
c q P E P\
11.07.2019
1��4W,A On
a
ALTERATION OF THIS DOCUMENT SHALL INVALIDATE THE
m
PROFESSIONAL SEAL AND SIGNATURE PUBLICATION OF
THIS DOCUMENT DOES NOT DEROGATE FROM RESERVED
OINJERSHIP RIGHTS IN IT. THIS DOCUMENT IS FOR USE
TA C O M A • SEATTLE • SPOKANE •TRI-CITIES
ONLY FOR THE PROJECT IDENTIFIED IN THE TITLE BLOCK
AND IS NOT TO BE USED FOR REPAIR, REMODEL OR
ADDITION TO THAT PROJECT OR FOR ANY OTHER PROJECT.
1200 6th Avenue, Suite 1620 Seattle, WA 98101
206.267.2425 TEL 206.267.2429 FAX www.ahbl.COm WEB
NOTES
1. SEE L2.2 FOR IRRIGATION LEGEND. SEE L2.3 FOR IRRIGATION DETAILS AND VALVE TABLE.
2. PROVIDE CONNECTION FROM NEW VALVES TO EXISTING CONTROLLERS IN MECHANICAL ROOM 212. REMOVE
CONNECTIONS TO VALVES DEMOLISHED AS PART OF PROJECT. COORDINATE ACCESS WITH SCHOOL DISTRICT.
3. EXISTING IRRIGATION SHOWN IS APPROXIMATE. SEE AS-BUILTS AVAILABLE FROM THE SCHOOL DISTRICT. VERIFY
EXTENT OF EXISTING IRRIGATION SYSTEM AND VERIFY EXTENT OF DISTURBANCE AND REPLACEMENT BEFORE
DEMOLITION. PROVIDE CREDIT FOR IRRIGATION WORK SHOWN ON PLANS BUT NOT REQUIRED AFTER REVIEW OF
EXTENT OF CONFLICT ON SITE. PROVIDE MARK-UPS OF ANY AREAS REQUIRING WORK NOT SHOWN ON PLAN FOR
CHANGE ORDER.
Q
4.
NO SUBSTITUTIONS OF EQUIPMENT OR DESIGN CHANGES SHALL BE PERMITTED UNLESS APPROVED BY THE OWNER.
N
5.
IRRIGATION LINES AND VALVES MAY BE SHOWN IN HARD SURFACE AREAS OR OUTSIDE LANDSCAPE AREAS FOR
N
GRAPHIC CLARITY. LOCATE ALL IRRIGATION LINES IN LANDSCAPE AREAS OR IN SLEEVES UNDER PAVEMENT.
J
w
6.
IRRIGATION CONTRACTOR SHALL COORDINATE INSTALLATION OF IRRIGATION CONDUIT AND SLEEVES UNDER HARD
w
SURFACES WITH RESPECTIVE CONTRACTORS.
U)
7.
CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS, TESTS, AND INSPECTIONS REQUIRED FOR THE
W
IRRIGATION SYSTEM.
z
8.
CALL FOR LOCATES PRIOR TO DIGGING AT 811. CONTRACTOR IS RESPONSIBLE TO VERIFY UTILITY LOCATIONS. IF
J
UTILITIES ARE DAMAGED IN THE COURSE OF WORK, CONTRACTOR SHALL INFORM THE OWNER AND MAKE ANY REPAIRS
=
REQUIRED, AT NO COST TO THE OWNER.
U
9.
ALL SLEEVING SHALL BE MARKED, SEALED AND STAKED. ALL SLEEVES SHALL BE TWICE THE SIZE OF OF THE LINE OR
Q
COMBINED LINES. MINIMUM SLEEVE SIZE SHALL BE 4-INCHES IF LOCATED UNDER ROADWAY OR DRIVE AISLE.
73
10.
INSTALL CONCRETE THRUST BLOCKS ON MAINLINE 2-1/2" AND LARGER, FOR ALL CHANGES IN PIPE DIRECTION OVER
15-DEGREES.
11.
SPLICE CONTROL WIRES WITHIN VALVE BOXES ONLY, USING 3M-DBY, OR APPROVED SPLICE KITS, AND PROVIDE A 24"
EXPANSION LOOP FOR ALL CONTROL WIRES WITHIN EACH VALVE BOX. KEEP WIRE SPLICES TO A MINIMUM. PROVIDE
CLEAN WIRE CUTS WITH NEW SPLICE KITS AT ALL SPLICES INCLUDING ANY SPLICE THAT IS DISCONNECTED AND
RECONNECTED FOR ANY REASON OR PERIOD OF TIME.
12.
VALVE BOXES SHALL BE COMMERICAL -GRADE POLYETHYLENE OR HDPE AND SUITABLE FOR LIGHT DUTY APPLICATIONS.
13.
INSTALLER TO ADJUST ALL ZONE CONTROL VALVES TO THE CORRECT OPERATING PRESSURE. SEE VALVE SCHEDULE
FOR OPERATING PSI.
14.
CONTRACTOR SHALL HAND TRENCH IRRIGATION DITCHES WHEN WITHIN 20 FEET, OR WITHIN A DELINEATED ROOT
PROTECTION ZONE, OF EXISTING TREES TO REMAIN. AVOID CUTTING ANY ROOTS OVER 3" - 4" IN DIAMETER WITHIN THE
ROOT PROTECTION ZONE.
15. INSTALLER SHALL BE RESPONSIBLE FOR KEEPING EXACT ACCURATE NOTES AND "AS-BUILTS" FOR THE CREATION OF
THE "RECORD DRAWINGS" OF THE INSTALLED SYSTEM.
16. CONTRACTOR SHALL PROVIDE IRRIGATION MAINTENANCE THROUGH THE PLANT ESTABLISHMENT PERIOD INCLUDING
WINTERIZATION(S) ,�bPrT8 fK0)CT I O N RECORD D RAW I N G S
1 ALTERNATE BID NO 1: SOCCER FIELD IMPROVEMENTS AG 1/28/19 KG SURVEYED: SCALE VERTICAL-
HOR ONTAL: NAD T9a3/T99T
DESIGNED: AS SHOWN
DRAWN:
MS ONE INCH DATUM
CHECKED: AT FULL SCALE
KG IF NOT ONE INCH
NO. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY
J. Morse
IRRIGATION SYSTEM DESIGN NOTES
2
3
ll
GRAPHIC SCALE
WATER PURVEYOR: KING COUNTY WATER DISTRICT 90.
CONTACT INFORMATION: 425-255-9600,http://www.kcwd9O.com/
THIS DESIGN REPLACES PORTIONS OF AN EXISTING IRRIGATION SYSTEM AFFECTED BY THE
RESURFACING OF SOFTBALL AND SOCCER FIELDS.
FIELD VERIFY ALL EXISTING IRRIGATION EQUIPMENT AND ZONES IMPACTED BY THE
CONSTRUCTION OF THIS PROJECT PRIOR TO CONSTRUCTION. CONTACT SCHOOL DISTRICT FOR
COPIES OF IRRIGATION AS -BUILT DRAWINGS.
PROVIDE TEMPORARY IRRIGATION TO ALL UNDISTURBED ZONES DURING CONSTRUCTION
BETWEEN APRIL AND OCTOBER OR AS REQUESTED BY SCHOOL DISTRICT.
POINT OF CONNECTION NOTES
1. POINT OF CONNECTION WORK NOT WITHIN SCOPE
OF PROJECT.
2. CONTRACTOR SHALL VERIFY EXISTING STATIC
PRESSURE AT THE METER AND SUBMIT WRITTEN
VERIFICATION TO THE LANDSCAPE ARCHITECT.
NOTIFY THE LANDSCAPE ARCHITECT OF
DISCREPANCIES GREATER THAN 5 POUNDS OF
DESIGN PRIOR TO INSTALLATION OF ANY
IRRIGATION EQUIPMENT.
3. POC NUMBER 1: EXISTING 4" IRRIGATION METER.
3.1. THE SYSTEM DESIGN IS BASED ON OPERATING 1
ZONE AT A TIME USING THE EXISTING
IRRIGATION METER ON A 6" SCH. 40 PVC
SUPPLY LINE. CONTRACTOR SHALL FIELD
VERIFY SIZE AND LOCATION.
NV f-' CITY OF
ME
RENTON
n�
Planning/Building/Public Works Dept.
O
N
O
0
00
co
0
0
0
06
OC
0—
z
0
a
0
z
w
cr
J
P LU
}
Q
LL
R-402831 _j
0
IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0
KEYMA
McKNIGHT MIDDLE SCHOOL FIELD IMPROVEMENTS
RENTON SCHOOL DISTRICT
ALTERNATE NO. 1
IRRIGATION PLAN
U
W
J
0
=
R
DATE
11/07/2019
FIELDBOOK:
PAGE:
v_
z
DRAWING NO:
L2.3
G
SHEEr.31 OF*325U
00
N
C)
i
Nt
i
0
w
z
_O
Q
O
z
w
rrr
vJ
0
W
H
Q
J
n
J
O
O
U
U)
ui
0
C0
G
r=
_V
z
V
U
C
G
0
o
ao
N
VALVE BOX LID, HEAD
BRAND "J BOX" ON LID
WITH 2" HIGH LETTERS X
1OX15 STANDARD BOX
PROTECTION SCREEN,
WRAP 6" UP SIDES
SET BOX 2" ABOVE
GRADE AT SHRUBS.
J
SET BOX FLUSH TO
_U
d
GRADE AT LAWN.
U
a_
SPARE WIRES THAT ARE
co
TO TERMINATE AT THIS
BOX: COIL 30" LENGTH
E
MAINLINE AS OCCURS.
TWO 6X2X16 CONCRETE BLOCK
CPAS, ONE ON EACH SIDE OF PEA GRAVEL - 4" DEPTH
BOX
I WIREB UNDLE �JUCTION BOX
3/4" = V-0"
P-2018-MCK-01
NOZZLE VARIES
(SEE IRRIGATION PLAN)
INSTALL 18" SQUARE OF SOD
AROUND SPRINKLER HEAD
FINISH GRADE
ROOT SAND COURSE
_
?.
~
ROTOR POP-UP
o ¢
SPRINKLER
w=
BASE SAND COURSE
z�
� Z
Of
DETECT -A -TAPE IN TRENCH
Lu
¢
w
PREFABRICATED TRIPLE SWING
J
>
JOINT ASSEMBLY, 1" DIA. X 12"
m
NOTE:
USE TEFLON TAPE ON
THREADED FITTINGS
PVC SCH 40 TEE OR
ELL SLIP x FIPT x SLIP
TRACE WIRE
40 PVC LATERAL
POP-UP ROTOR HEAD AT SPORTS FIELD
VALVE BOX W/ EXTENSIONS,
SET 2" ABOVE GRADE IN
SHRUBS, FLUSH IN TURF.
WATERPROOF WIRE
CONNECTORS ON 36"
LOOPED WIRES.
Lu
ry
0
o SCH 80 UNION
i LATERAL, 24"
m MIN. TO FIRST
NJ FITTING
Ei
6X2X16 CONC. BLOCK, ONE PER
CORNER (4 TOTAL)
FILTER FABRIC, WRAP UP ALL
SIDES ABOVE OPENINGS
WASHED DRAIN ROCK SUMP, 2
CUBIC FEET MIN.
REMOTE CONTROL VALVES
PLANTING CONDITION
FINISHED GRADE
PAVING SECTION PER
CIVIL PLANS
—COMPACTED BACKF
— AT 85% DENSITY
(SOIL BACKFILL)
AT 95% DENSITY -
(STRUCTURAL)
— LATERAL LINE(S) AN
WARNING TAPE
SLEEVE(S), 2-TIMES -
LINE SIZE MIN.
—MAIN LINE(S)
— VALVE WIRING
— PIPE BED MATERIAL
BE CLEAN AND FREE
ROCK LARGER THAT
1/2-INCH
TRENCHING & SLEEVING
NTS
NOZZLE VARIES
(SEE IRRIGATION PLAN)
FINISH GRADE
ROTOR POP-UP SPRINKLER
TRIPLE SWING JOINT ASSEMBLY,
1" DIA. X 12"
SCH 40 PVC LATERAL
NOTE:
USE TEFLON TAPE ON ALL
THREADED FITTINGS
POP-UP ROTOR HEAD
PVC SCH 40 TEE OR
ELL SLIP x FIPT x SLIP
-2018-MCK-07 \ /
1/8" = 1'-0"
P-2018-MCK-43
10" DIA. VALVE BOX W/
LOCKING LID,
EXTENSIONS (AS REQ'D)
FINISH
GRADE
REMOTE CONTROL VALVE
TRUE UNION PVC BALL
`�/\\��\\��\
\\�/��/j�/j
\�!%//i\/
MANUAL DRAIN BALL
VALVE WITH SCH. 80
VALVE W/ LONG KEY FOR
NIPPLES
z
OPERATION
N ~
SCH 40 PVC MAIN LINE
SCH 80 PVC ELL OR
TEE W/ REDUCER
X SCH 80 3/4" PVC ELLS W/
IPVC NIPPLES IN BETWEEN
3/4" SCH 80 PVC STREET
Z ELL W/ 6" LENGTH OF PVC
z PIPE W/ HOLES DRILLED
FOR DRAIN LINE
SUPPORT VALVE BOX 1/2 CU YD OF PEA GRAVEL
WITH (4) BRICKS-TYP.
MAINLINE NOTE: USE TEFLON TAPE ON ALL THREADED FITTINGS.
SCH. 40 RISER
rn_NMANUAL DRAIN VALVE WITH SUMP
NTS P-2018-MCK-7
of WAS
R . S
�i���111�1�To
Know what's below.
Call before you dig.
� O
P . o,3 �\
c'I PE ARG
11.07.2019
1��
�1►169:1�•L�:1:7y_�il•
NOTES:
• DIMENSIONS ARE MINIMUM
CLEARANCES.
DO NOT TAPE OR BUNDLE
WIRES IN SLEEVES.
z
ASPHALT,
CONCRETE,
MASONRY OR —
CRUSHED ROCK
SURFACE
P-2018-MCK-80
6"MAX
4.
a a
w Q
o g
w
z_T
J
J Z
Of�
w =
J
NOTE:
USE TEFLON TAPE ON ALL
THREADED FITTINGS
POP-UP SPRAY HEAD
1/8" = 1'-0"
P-2018-MCK-03
POURED IN -PLACE CONCRETE,
120 LBS. MINIMUM, TYPICAL
45 DEG. ELBOW TEE
FINISHED GRADE
90 DEG. ELBOW
UTILITY BOX.
. ' END OF LINE
4-
A. .• ;' ,.
CAPPED
SECTION VIEW
THRUST BLOCKING
P-2018-MCK-04
10" DIAMETER VALVE BOX.
HEAD BRAND "QVC" ON LID
Q
WITH 2" HIGH CHARACTERS.
w
QC \/
0-1 C/i
¢ ¢
SPRAY NOZZLE (SEE IRRIGATION PLAN)
Z LU
¢ ¢
J m
FLUSH w/ FINISHED GRADE
12" MAX
(TOP OF MULCH) IN BED AREAS
6" MIN.
z_ x
U) U)
¢
J z
FINISH GRADE
_
FINISHED GRADE.
LL N
N
POP UP SPRAY HEAD OR
IIIIII—III
I
III
�
—III
FLOOD BUBBLER
I—IIII
=1 (
1III—III
QUICK COUPLING VALVE AS
TRIPLE SWING JOINT ASSEMBLY,
SPECIFIED.
1/2" DIA. X 12"
TWO STAINLESS
—
SCH. 80 NIPPLE, LENGTH AS REQ.
STEEL CLAMPS.
6" DEEP LAYER OF 3/4"
LATERAL PIPE
o
o CRUSHED ROCK.
000
3" PVC SCHEDULE 80
NIPPLE.
1/2" X 36" GALV
PVC SCH 40 TEE OR ELL
STEEL PIPE.
•
SLIP x FIPT x SLIP
THREE PVC SCH 80
ELLS.
12" PVC SCHEDULE 80
NIPPLE.
QUICK
COUPLER
IN VALVE BOX
7
P-2018-MCK-4'
1 1 /2" = 1'-0"
CONSTRUCTION RECORD DRAWINGS
1 ALTERNATE BID NO 1: SOCCER FIELD IMPROVEMENTS AG 1/28/19 KG SURVEYED:
DESIGNED:
ALTERATION OF THIS DOCUMENT SHALL INVALIDATE THE
PROFESSIONAL SEAL AND SIGNATURE PUBLICATION OF
-
DRAWN: MS
THIS DOCUMENT DOES NOT DEROGATE FROM RESERVED
ONNERSHIP RIGHTS IN IT. THIS DOCUMENT IS FOR USE
ONLY FOR THE PROJECT IDENTIFIED IN THE TITLE BLOCK
TA C O M A • SEATTLE • SPOKANE •TRI-CITIES
CHECKED:
KG
AND IS NOT TO BE USED FOR REPAIR, REMODEL OR
ADDITION TO THAT PROJECT OR FOR ANY OTHER PROJECT.
6th Avenue,, Suite WA
WEB
NO.
REVISION
BY
DATE
AP P R
APPROVED:
201 260 TEL 7.24290F�Seat
om
J. Morse
SCALE
AS SHOWN HORIZONTAAL L r D igw/mi NV f-)
DA
CITY OF
ME
RENTON
ONE INCH DATUM
AT FULL SCALE Planning/Building/Public Works Dept.
IF INN ONE INCH
SCALE ACCORDINGLY
z
0
¢
RCV 0
IV
BOXES
cm TYP. ro EDGE OF LAWN OR BED
NOTES: EDGE OF PAVING
1. CENTER BOX OVER VALVE TO FACILITATE REMOVAL & SERVICING.
2. SET BOXES PARALLEL TO EACH OTHER & PERPENDICULAR TO BED EDGE.
3. AVOID OVER -COMPACTION TO PREVENT DEFORMATION & COLLAPSE OF BOX.
VALVE BOX INSTALLATION
3/4" = V-0"
N
C)
C)
00
T
LJ
C)
0
i
00
�IIII j
z
O
Q
IIIII
O
z
w
r�
vJ
%
0
KEYMAP
ui
Q
J
R-402832
_j
O
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
0
2
U
U)
w
0
0
DATE
McKNIGHT MIDDLE SCHOOL FIELD IMPROVEMENTS 11/07/2019 =
RENTON SCHOOL DISTRICT FlaoeDDK: (D
PAGE: _
DRAWING NO: z
IRRIGATION DETAILS r. O
SHEET0
2 �32 2