Loading...
HomeMy WebLinkAboutVideo Inspection Report • (- PRO-VAC tt unk 6622 112TH ST. pitommiat PUYALLUP, WA 98373 1-888-656-5665 253-435-4328 Observations by Inspections SITE DATA Mainline ID: City: Address: SSMH #H2-10 1 RENTON 1 17121 SE 138TH ST Upstream node: Downstream node: Pipe type: Pipe shape: Pipe height: Pipe width: SSMH #H2-10 1 SSMH #H2-09 9 PVC 1 Circular 18 INSPECTION DATA Scheduled Date: Start date/time: End date/time: 5/7/2014 9:57:33 AM I 5/7/2014 10:04:34 AM 15/7/2014 10:12:17 AM 6 Surveyed footage: Status: Operator: Work order No.: o • 232.3 ( Stopped J Pat Pacheco - I Reason: Weather: Condition: Assessment 1 Clear 1 ! I Comments WITH THE FLOW OBSERVATIONS Footage Rev. Length Clock From Clock To Code Modifiers/Severity Rating 0.0 No START WITH FLOW 0.0 No MH Upstream • 225.3 No 9 Lateral Left 232.3 No MH Downstream 232.3 No STOP �s Observations By Inspections Thursday,May 08,2014 11:50 AM Page • 1 of 10 PRO-VAC 6622 112TH ST.E 'PROARS . �✓, PUYALLUP,WA 98373 1-888-656-5665 253-435-4328 Observations by Inspections SITE DATA Mainline ID: City: Address: SSMH #Fi2-09 RENTON • [ 17121 SE 138TH ST Upstream node: Downstream node: Pipe type: Pipe shape: Pipe height: Pipe width: SSMH #H2-09 • SSMH #1-12-08 ( PVC Circular 8 INSPECTION DATA, Scheduled Date: Start date/time: End date/time: 5/7/2014 9:58:45 AM 5/7/2014 10:13:00 AM 5/7/2014 10:27:15 AM Surveyed footage: Status: Operator: Work order No.: 357.0 I Stopped I Pat Pacheco �� Reason: Weather: Condition: • Assessment Clear 1 Comments WITH THE FLOW OBSERVATIONS Footage Rev. Length Clock From Clock To Code Modifiers/Severity Rating 0.0 No START WITH FLOW 0.0 No MH Upstream 230.3 No 9 Lateral Left 296.0 No 9 Lateral Left 357.0 No - MH Downstream 357.0 No . STOP �_, Observations By Inspections Thursday,May 08,2014 11:50 AM Page 2 of 10 PRO-VAC e 6622 112TH ST.EDa PUYALLUP,WA 98373 1-888-656-5665 253-435-4328 _ Observations by Inspections_ SITE DATA Mainline ID: City: Address: SSMH #H2-08 I RENTON 11.7.1.21.1E13211-1.52_1 Upstream node: Downstream node: Pipe type: Pipe shape: Pipe height: Pipe width: SSMH #H2-08 I SSMH #H2-07 I PVC I Circular 8 INSPECTION DATA Scheduled Date: Start date/time: End date/time: 5/7/2014 11:19: AM i 5/7/2014 11:58:09 AMJ5/7/2014 12:04:22 PM I Surveyed footage: Status: Operator: Work order No.: 211.3 Stopped Pat Pacheco Reason: Weather: Condition: Assessment I Clear Comments AGAINST THE FLOW OBSERVATIONS Footage Rev. Length Clock From Clock To Code Modifiers/Severity Rating 0.0 Yes START AGAINST FLOW 0.0 Yes MH Downstream 211.3 Yes MH Upstream 211.3 Yes STOP • Observations By Inspections Thursday,May 08,2014 11:50 AM Page 3 of 10 • PRO-VAC ' �wIn 6622 112TH ST.E PUYALLUP,WA 98373 1-888-656-5665 253-435-4328 Observations by Inspections SITE DATA Mainline ID: City: Address: SSMH #1-12-07 REANTON J 17121 SE 138TH ST Upstream node: Downstream node: Pipe type: Pipe shape: Pipe height: Pipe width: SSMH #H2-07 + SSMH #H2-06 I PVC I Circular 18 t 4 INSPECTION DATA Scheduled Date: Start date/time: End date/time: 5/7/2014 12:58:13 PM I 5/7/2014 12:59:46 PM1/ 014 1:01:05 PM 9 Surveyed footage: Status: Operator: Work order No.: 25.8 t Stopped Pat Pacheco Reason: Weather: Condition: Assessment I Clear J Comments WITH THE FLOW OBSERVATIONS Footage Rev. Length Clock From Clock To Code Modifiers/Severity Rating 0.0 No START WITH FLOW 0.0 No MH Upstream 25.8 No MH Downstream 25.8 No STOP ���� Observations By Inspections Thursday,May 08,2014 11:50AM Page 4 of 10 PRO-VAC 6622 112TH ST.E 911041114 PUYALLUP,WA 98373 1-888-656-5665 253-435-4328 Observations by Inspections SITE DATA Mainline ID: City: Address: SSMH #H2-06 RENTON 117121 SE 138TH ST Upstream node: Downstream node: Pipe type: Pipe shape: Pipe height: Pipe width: SSMH #H2-06 SSMH #H2-05 1 PVC Circular 8 INSPECTION DATA Scheduled Date: Start date/time: End date/time: 5/8/2014 1:01:40 PM 5/8/2014 8:31:14 AM 5/8/2014 8:47:20 AM Surveyed footage: Status: Operator: Work order No.: 320.1 I Stopped I Pat Pacheco Reason: Weather: Condition: Assessment I Clear Comments WITH THE FLOW OBSERVATIONS Footage Rev. Length Clock From Clock To Code Modifiers/Severity Rating 0.0 No START WITH FLOW 0.0 No MH Upstream 138.3 No 6.2 Sag 3/8" 162.7 No 9 Lateral Left 262.4 No 9 Lateral Left 320.1 No MH Downstream 320.1 No STOP Observations By Inspections Thursday,May 08,2014 11:50 AM Page 5 of 10 PRO-VAC �� t 6622 112TH ST.E • 1 7° PUYALLUP,WA 98373 1-888-656-5665 :;:;.,;i•; 253-435-4328 Observations by Inspections SITE DATA Mainline ID: \ City: Address: SSMH #H2-05 I RENTON 171_2_1.1E_138TH ST ! Upstream node: Downstream node: Pipe type: Pipe shape: Pipe height: Pipe width: SSMH #H2-05 SSMH #H2-04 I PVC Circular 8 J INSPECTION DATA Scheduled Date: Start date/time: End date/time: 5/8/2014 8:48:02 AM ! 5/8/2014 9:29:57 AM 5/8/2014 9:32:09 AM Surveyed footage: Status: Operator: Work order No.: 17.1 Ilt_olp_e_cl Pat Pacheco Reason: Weather: Condition: Assessment Clear Comments AGAINST THE FLOW OBSERVATIONS Footage Rev. Length Clock From Clock To Code Modifiers/Severity, Rating 0.0 Yes START AGAINST FLOW 0.0 Yes MH Downstream 17.1 Yes MH Upstream 17.1 Yes STOP Observations By Inspections Thursday,May 08,2014 11:50AM Page 6 of 10 PRO-VAC 6622 112TH ST.E AM PUYALLUP,WA 98373 1-888-656-5665 253-435-4328 Observations by Inspections SITE DATA Mainline ID: City: Address: SSMH #1-12-04 I RENTON ! 17121 SE 138TH ST Upstream node: Downstream node: Pipe type: Pipe shape: Pipe height: Pipe width: SSMH #H2-04 SSMH #H2-03 ! PVC I Circular 8 INSPECTION DATA Scheduled Date: Start date/time: End date/time: 5/8112014 9:35:18 AM 5/8/2014 9:35:38 AM (5/8/2014 9:50:18 AM Surveyed footage: Status: Operator: Work order No.: 355.3 I Stopped I Pat Pacheco Reason: Weather: Condition: Assessment I Clear I Comments WITH THE FLOW OBSERVATIONS Footage Rev. Length Clock From Clock To Code Modifiers/Severity Rating I 0.0 No START WITH FLOW 0.0 No MH Upstream 198.7 No 9 Lateral Left 267.3 No 6.6 Sag 3/8" 1 291.1 No 6.3 Sag 3/8" 355.3 No MH Downstream 355.3 No STOP Observations By Inspections Thursday,May 08,2014 11:50 AM Page 7 of 10 PRO-VAC ' Sea K 6622 112TH ST.E � ' PUYALLUP,WA 98373 1-888-656-5665 253-435-4328 Observations by Inspections SITE DATA Mainline ID: City: Address: SSMH #112-03 I RENTON J 17121 SE 138TH ST Upstream node: Downstream node: Pipe type: Pipe shape: , Pipe height: Pipe width: SSMH #H2-03 I SSMH #H2-02 I PVC I Circular 18 INSPECTION DATA Scheduled Date: Start date/time: End date/time: 5/8/2014 9:52:35 AM 5/8/2014 9:54:26 AM 5/8/2014 10:35:14 AM Surveyed footage: Status: Operator: Work order No.: 394.0 I Stopped Pat Pacheco Reason: Weather: Condition: Assessment B Clear J Comments WITH THE FLOW OBSERVATIONS Footage Rev." Length Clock From Clock To Code Modifiers/Severity Rating 0.0 No START WITH FLOW 0.0 No MH Upstream I 115.1 No 9 Lateral Left 370.9 No 3 Lateral Right 375.7 No 2.4 Sag 3/8" 381.0 No 3 Lateral Right 394.0 No MH Downstream I 394.0 No STOP Observations By Inspections Thursday,May 08,2014 11:50 AM Page 8 of 10 PRO-VAC PM/4kt 6622 112TH ST.E PUYALLUP,WA 98373 1-888-656-5665 253-435-4328 Observations by Inspectionsj SITE DATA Mainline ID: City: Address: SSMH #H2-02 I RENTON ! 17121 SE 138TH ST Upstream node: Downstream node: , Pipe type: Pipe shape: Pipe height: Pipe width: SSMH #H2-02 ! SSMH #H2-01 l PVC I Circular j 8 I INSPECTION DATA Scheduled Date: Start date/time: End date/time: . 5/8/2014 10:38:29 AM ( 5/8/2014 10:38:57 AM 5/8/2014 10:50:18 AM Surveyed footage: Status: Operator: Work order No.: 235.3 I Stopped I Pat Pacheco Reason: Weather: Condition: Assessment I Clear Comments WITH THE FLOW OBSERVATIONS Footage Rev. .Length Clock From Clock To Code Modifiers/Severity Rating 0.0 No START WITH FLOW 0.0 No MH Upstream 0.0 No 9.2 Sag 3/8" 1 117.7 No 10.1 Sag 3/8" 156.4 No 8.9 . Sag 3/8" 209.0 No 2.6 Sag 3/8" 224.8 No 2.3 Sag 1/2" 227.1 No 1.4 Sag 7/8" 228.5 No 4.5 Sag 1"> 235.3 No MH Downstream 235.3 No STOP Observations By Inspections Thursday,May 08,2014 11:50 AM Page 9 of 10 PRO-VAC 6622 112TH ST.E P�►O-V`►C PUYALLUP,WA 98373 1-888-656-5665 253-435-4328 Observations by Inspections SITE DATA Mainline ID: City: Address: SSMH #H2-01 RENTON 1 17121 SE 138TH ST Upstream node: Downstream node: Pipe type: Pipe shape: Pipe height: Pipe width: SSMH #H2-01 1 SSMH #H2- EX 1 PVC 1 Circular 1 8 INSPECTION DATA Scheduled Date: Start date/time: End date/time: 5/8/2014 11:00:01 AM 15/8/2014 11:08:26 AM 15/8/2014 11:21:50 AM I Surveyed footage: Status: Operator: Work order No.: 283.4 1 Stopped 1 Pat Pacheco 1 Reason: Weather: Condition: Assessment 1 Clear J Comments WITH THE FLOW OBSERVATIONS Footage Rev. Length Clock From Clock To Code Modifiers/Severity Rating • 0.0 No START WITH FLOW 0.0 No MH Upstream 176.0 No 8.0 Sag 3/8" 184.0 No 4.5 Sag 1/2" 188.5 No 2.6 Sag 1" 188.5 No 9 Lateral Left 191.1 No 1.8 Sag 1/2" 202.4 No 6.5 Sag 3/8" 212.4 No 5.1 Sag 1/2" 220.0 No 8.0 Sag 1/2" 283.4 No MH Downstream 283.4 No STOP Observations By Inspections l Thursday,May 08,2014 11:50 AM Page 10 of 10