Loading...
HomeMy WebLinkAboutPDF_S1City : Renton Street Union Ave NE Bravo Environmental RAVO�o BTet: Upstream MH 6705 NE 175th St City Renton Kenmore, WA 98028 Drainage Area Dowstream MH 425-424-9000 1 env1rionmenia Fax: Ema24-9002 Flow Control Inspection Report / Inspection: 1 Downstream Date P/O. No. Weather Surveyor's Name Pipe Segment Reference Section No. 8/4/2011 Joint Length Dry Tim 1 Certificate No. Survey Customer System Owner Date Cleaned Pre -Cleaning Sewer Category 04-7919 Tape / Media No. 8-4-11 Lining Method Add. Information : Street Union Ave NE Use of Sewer Sanitary Upstream MH 7 City Renton Drainage Area Dowstream MH 6 Loc. details Flow Control Dir. of Survey Downstream Location Code Length surveyed 232.97 ft Section Length 232.97 ft Purpose of Survey Pre -Acceptance Joint Length Year Laid Dia./Height 8 inch Year Rehabilitated Material Polyvinyl Chloride Tape / Media No. 8-4-11 Lining Method Add. Information : 1:585 Position Code Observation Photo 7 0.00 AMH Manhole / 7 75.14 TF Tap Factory Made, at 09 o'clock, 6", within 8 inches of joint: YES 106.46 TF Tap Factory Made, at 03 o'clock, 6", within 8 inches of I joint: YES 188.85 TF Tap Factory Made, at 03 o'clock, 6", within 8 inches of joint: YES 193.39 TF Tap Factory Made, at 09 o'clock, 6", within 8 inches of joint: YES 232.97 AMH Manhole / 6 6 QSR QMR SPR MPR OPR SPRI MPRI OPRI 0000 0000 0 0 0 0 0 0 Rosewood Highlands // Page: 1