HomeMy WebLinkAboutzR-3967SetM 0 v D BRH ENGINEERING NOTES: 1. EXISTING UTILITIES AND UNDERGROUND STRUCTURES SHOWN ON THE PLAN ARE BASED UPON THE BEST AVAILABLE PUBLIC RECORDS AND/OR PRIVATE RECORDS AS SUPPLIED BY THE PROJECT OWNER AND/OR DATA OBTAINED VERBALLY FROM OWNERS OR OFFICIALS ASSOCIATED WITH THE PARTICULAR UTILITY. NEITHER THE OWNER NOR THE ENGINEER GUARANTEE THE ACCURACY OR COMPLETENESS OF THIS INFORMATION AND ASSUME NO RESPONSIBILITY FOR IMPROPER LOCATIONS OR FAILURE TO SHOW UTILITY LOCATIONS ON THE CONSTRUCTION PLANS. OTHER UNDERGROUND FACILITIES NOT SHOWN ON THE DRAWINGS MAY BE ENCOUNTERED DURING THE COURSE OF THE WORK. ALL INVERT ELEVATIONS SHOWN ON THE DRAWINGS SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. 2. IF CHANGED CONDITIONS ARE ENCOUNTERED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PROMPTLY OF (1) PREEXISTING SUBSURFACE CONDITIONS DIFFERING FROM THOSE INDICATED IN THE PLANS, OR (2) PREEXISTING UNKNOWN SUBSURFACE CONDITIONS, OF AN UNUSUAL NATURE, DIFFERING MATERIALLY FROM THOSE ORDINARILY ENCOUNTERED AND GENERALLY RECOGNIZED AS INHERENT IN WORK OF THE CHARACTER PROVIDED FOR IN THE CONTRACT. THE CONTRACTOR AND/OR THE OWNER SHALL MAKE NO CLAIMS TO THE ENGINEER FOR RECOMPENSATION FOR EXTRA WORK RESULTING FROM CHANGED CONDITIONS UNLESS THE ENGINEER HAS APPROVED THE WORK IN WRITING. (WSDOT SECTION 1-04.7). 3. THE CONTRACTOR SHALL CALL THE UTILITIES UNDERGROUND LOCATION CENTER FOR FIELD LOCATION OF ALL UTILITIES AND SHALL NOT BEGIN EXCAVATION UNTIL ALL KNOWN UNDERGROUND FACILITIES IN THE VICINITY OF THE PROPOSED WORK HAVE BEEN LOCATED AND MARKED. IF THE UTILITY IS NOT A SUBSCRIBER OF THE UNDERGROUND LOCATION CENTER THEN THE CONTRACTOR SHALL GIVE INDIVIDUAL NOTICE TO THAT UTILITY. (WSDOT SECTION 1-07.17 APWA SUPPLEMENT). 4. THE CONTRACTOR SHALL TAKE REASONABLE PRECAUTIONS AND EXERCISE SOUND ENGINEERING AND CONSTRUCTION PRACTICES IN CONDUCTING THE WORK. THE CONTRACTOR SHALL PROTECT EXISTING PUBLIC AND PRIVATE UTILITIES FROM DAMAGE DURING CONSTRUCTION. IF EXISTING UTILITIES ARE DAMAGED, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND THE ENGINEER. THE CONTRACTOR SHALL RESTORE THE UTILITY TO ITS EXISTING CONDITION. (WSDOT SECTION 1-07.17 APWA SUPPLEMENT). THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION FOR DESIGNS SHOWN ON THESE PLANS. 5. WHERE THE PLANS CALL FOR UTILITIES TO BE RELOCATED BY OTHERS, THE CONTRACTOR SHALL NOTIFY THE UTILITY COMPANY AND COORDINATE HIS WORK SO AS TO AVOID CONFLICTS. 6. ALL EXCAVATION, TRENCHING, SUBGRADE PREPARATION, FILL PLACEMENT AND COMPACTION AND ALL SOIL WORK IN GENERAL SHALL BE CONDUCTED IN COMPLIANCE WITH THE RECOMMENDATIONS OF THE PROJECT SOIL ENGINEER AND THE CURRENT GEOTECHNICAL ENGINEERING REPORT. 7. ENGINEERING DESIGN AND APPROVAL FOR STRUCTURES SUCH AS WALLS AND VAULTS MUST BE PREPARED BY THE APPROPRIATE PROFESSIONAL ENGINEER AND IS NOT A PART OF THESE PLANS. 8. CONTRACTOR SHALL BE RESPONSIBLE FOR HIRING PROFESSIONAL LAND SURVEYOR TO REFERENCE EXISTING MONUMENTS ON OR ADJOINING SITE PREVIOUS TO DEMOLITION OR CONSTRUCTION AND TO RE—ESTABLISH SAID POINTS AT PROJECT COMPLETION. THIS RE—ESTABLISHMENT SHALL BE DOCUMENTED BY RECORD OF SURVEY OR CORNER RECORD AS DESCRIBED IN W.A.C. 332-120. SITE AND GRADING QUANTITIES: LOT TOTAL SQUARE FOOTAGE: 134,074 SF (3.0779 AC) AREA OF WORK: 5,578 SF TOTAL CUT: 140 CY TOTAL FILL: 90 CY THE PROJECT'S TESC PLAN SHEET MUST BE LOCATED ONSITE DURING THE DURATION OF PROJECTS CONSTRUCTION. THE PROJECTS TESC PLAN SHEET MUST REFLECT ALL TESC CHANGES MADE ONSITE DURING CONSTRUCTION AND THOSE PLAN REVISIONS MUST BE INITIALED AND DATED BY THE PROJECTS CERTIFIED TESC REPRESENTATIVE. TEMPORARY DEWATERING: IF A PROJECT REQUIRES TEMPORARY DEWATERING, PLEASE CONTACT THE CITY OF RENTON CUSTOMER SERVICE AT 425-430-7200 TO ESTABLISH A PLAN FOR DEWATERING. pBUSH, ROED & HITCHINGS, INC. N SEAL� f� LAND SURVEYORS & CIVIL ENGINEERS 2009 MINOR AVE. EAST (206) 323-4144 �gSTiING1a Is SEATTLE, Washington 1-800-935-0508 I1 98102-3513 FAX# (206) 323-7135 US BANK EXPANSION 2500 EAST VALLEY ROAD RENTON, WA 98057 C-17003123 N. 1/4 COR. SEC. 30 FNS. 1/2' BRONZE ROD W/PUNdi IN VASE, DOWN 0.3• (SITED 6 -25 -OB (CITY RENTON HORIZONTAL CONTROL 19 11616 0) IN 1 N 170576.87 3 E 1297863.14 ROW MONUMENT E. VALLEY RD. p MD. TACK IN Y CONIC. MIXT IN CASE. p DOWN 1.0' ,n (SITED 6 -25 -OB Da _ v`ITI PROPOSED WATER ALIGNMENT CL I , j S8810'08'E — p23.64— �_— __--_ —_—_l I I L — ADDITION �I 1 I , I 35.00' 136 II 1 II EX WATER 1 II -,, � 00) EASMENT 1 1 , CENTERLINE I I I al EX WATER 1 I 1 I EASEMENT r I I aW u 1 1 �7I I L - EX >I - BUILDING = 11 T F I � III 1 1 AQI II I11 I I II II � LOT 3 �i 2500 EAST VALLEY R \ II 1 IVB � I i — — — — — — — SW 27TH ST ROW MONUMENT E. VALLEY HWY. 11 armW E 3m.1w MD. 1-3/4 111 DISC W/'+ - IN CONC. MON IN CASE, . 3 DOWN 0.4 (SITED B -25 -OB EAST 0.05' OF CALC. INTERSECTION zi 50 25 0 50 700 N SCALE IN FEET 1"=50' JM" AS SHOWN ''�-' CITY OF ZJE RENTON ZJE DATUM Tm Planning/Building/Public Works Dept. NO. REVISION BY DATE APPR Tm PROJECT CONTACTS PROJECT ADDRESS: SURVEYOR: 2500 EAST VALLEY RD. BUSH, ROED & HITCHINGS, INC RENTON, WA 98057 2009 MINOR AVE E SEATTLE, WA 98102 OWNER: CONTACT: TAYLOR SHULTE, P.LS. STRADA DA VALLE, LLC tayors®brhinc.com CONTACT: BRAD MERUNO PHONE: (206) 323-4144 PHONE: (206) 658-0950 5050 1ST AVE S, STE 102 ENGINEER: SEATTLE, WA 98134 BUSH, ROED & HITCHINGS, INC 2009 MINOR AVE E ARCHITECT OF RECORD: TAWA 98102 CORNERSTONE ARCHITECTURAL GROUP CONTACTCT : TED DIMOF, P.E. CON KENMORE, WA 98028 CONTACTS:RICK UTT PHONE: (206) 323-4144 PHONE:tedd@br (20) 3 rutt®comerstonearch.com PHONE: (206) 325-2553 UTILITY CONTACTS SANITARY SEWERS, STORM POWER AND NATURAL GAS DRAINAGE, AND WATER PUGET SOUND ENERGY CITY OF RENTON 10885 NE 4TH STREET, SUITE 1200 1055 SOUTH GRADY WAY PO BOX 97034 RENTON, WA 98057 BELLEVUE, WA 98009-9734 (425) 430-7200 (425) 454-6363 TELEPHONE (888) 225-5773 CENTURY LINK 1600 7TH AVENUE SEATTLE, WA 98191 (800) 244-1111 MMEIAAII111J0I Cl COVER SHEET C2 CITY OF RENTON UTILITY NOTES C3 HORIZONTAL CONTROL AND TOPOGRAPHY PLAN C4 SITE PLAN C5 DEMOLITION AND TESC PLAN C6 TESC DETAILS C7 GRADING AND DRAINAGE PLAN C8 WATER PLAN C9 RENTON STANDARD WATER DETAILS L1.0 TREE RETENTION/LAND CLEARING (TREE INVENTORY) PLAN & IRRIGATION PLAN L1.1 LANDSCAPE PLANTING PLAN AND DETAILS IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING SURFACE WATER UTILITY jtjohnson 09/01/2017 rstraka 09/05/2017 REGIONAL FIRE AUTHORITY WATER UTILITY dAPPROVEDho 7 Abdoul Gatour 09/05/2017 0 COVER SHEET `8/18/17 US BANK EXPANSION 2500 EAST VALLEY ROAD RENTON, WASHINGTON 98057 STRADA DA VALLE R-396701 SURFACE WATER DRAINAGE NOTES AND SPECIFICATIONS: 4. 5. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON PLAN REVIEWER. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE 1996 STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS, WHICH ARE ON FILE IN THE PUBLIC WORKS DEPARTMENT. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 6. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND THEY MUST BE SATISFACTORILY MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON -SITE EROSION HAS PASSED. 7 0 0 15. 16 17 18 ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. GRASS SEED MAY BE APPLIED BY HYDROSEEDING. THE GRASS SEED MIXTURE, OTHER THAN CITY OF RENTON APPROVED STANDARD MIXES, SHALL BE SUBMITTED BY A LANDSCAPE ARCHITECT AND APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7-02.3(1) OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS 'C", WITH THE EXCEPTION OF PVC PIPE. ALL TRENCH BACKFILL SHALL BE COMPACTED TO MINIMUM 95% FOR PAVEMENT AND STRUCTURAL FILL AND 90% OTHERWISE PER ASTM D-1557-70. PEA GRAVEL BEDDING SHALL BE 6 INCHES OVER AND UNDER PVC PIPE. GALVANIZED STEEL PIPE AND ALUMINIZED STEEL PIPE FOR ALL DRAINAGE FACILITIES SHALL HAVE ASPHALT TREATMENT #1 OR BETTER INSIDE AND OUTSIDE. STRUCTURES SHALL NOT BE PERMITTED WITHIN 10 FEET OF THE SPRING LINE OF ANY STORM DRAINAGE PIPE, OR 15 FEET FROM THE TOP OF ANY CHANNEL BANK. ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL. OPEN CUT ROAD CROSSINGS THROUGH EXISTING PUBLIC RIGHT OF WAY WILL NOT BE ALLOWED UNLESS SPECIFICALLY APPROVED BY CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS ADMINISTRATOR. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF ONE (1) FOOT AND MUST MEET THE FOLLOWING SPECIFICATIONS: 4 - 8 INCH ROCK / 40 - 70% PASSING; 2 - 4 INCH ROCK / 30 - 40% PASSING; AND LESS THAN 2 INCH ROCK / 10 - 20% PASSING. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS APPROVED BY THE CITY PLAN REVIEWER OR SURFACE WATER UTILITY SECTION. AN ACCURATELY DIMENSIONED, CERTIFIED AS -BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY UPON COMPLETION. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY OF RENTON DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM PROVIDED DURING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACT. ANY WORK WITHIN THE TRAVELED RIGHT OF WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVE BY THE PUBLIC WORKS DEPARTMENT, TRANSPORTATION SYSTEMS DIVISION. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-07-23 TRAFFIC CONTROL SHALL APPLY. SPECIAL DRAINAGE MEASURES WILL BE REQUIRED IF THE PROJECT LOCATION IS WITHIN THE AQUIFER PROTECTION AREA (APA) H' rch'i 0R,9� yc, SEAL z � n 1969 �q i�c1+' WATER PLAN GENERAL NOTES: 1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON PUBLIC WORKS STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS AND WSDOT / APWA STANDARD SPECIFICATIONS, LATEST EDITION AS AMENDED BY THE CITY OF RENTON. A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR AND OR DEVELOPER SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION. 2. ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL CALL 1-800-424-5555 TO VERIFY UTILITY LOCATIONS BEFORE BEGINNING EXCAVATION. 3. ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER SYSTEM IMPROVEMENTS SHALL BE NEW AND UNDAMAGED, AND "CATALOG CUTS" FOR ALL MATERIALS SHALL BE APPROVED IN WRITING BY THE CITY OF RENTON PRIOR TO BRINGING ANY MATERIALS ON -SITE. 4. ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C 151 AND C 104. PIPE JOINTS SHALL BE PUSH -ON OR MECHANICAL JOINT. CAST IRON OR DUCTILE IRON PIPE FITTINGS SHALL BE CLASS 250 AS PER ANSI/AWWA C110/A21.10-82. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 8 -MIL BLACK, TUBE -TYPE, POLYETHYLENE PLASTIC PER AWWA C105 STANDARDS. 5. MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 36 INCHES FOR PIPE DIAMETER OF 10 -INCH OR LESS AND 48 INCHES FOR PIPE DIAMETER OF 12 -INCH AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHALL BE 60 INCHES. ANY DEVIATIONS MUST BE APPROVED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. WHERE UTILITY CONFLICTS OCCUR, THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED AS NECESSARY TO CLEAR CONFLICTS AND TO PROVIDE MINIMUM COVER. PIPE DEFLECTION SHALL NOT EXCEED ONE-HALF OF PIPE MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE USED. ALL TRENCH BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST METHOD (MDD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT MDD IN UNPAVED AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 MDD. 6. CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED AND POURED IN PLACE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS, FITTINGS AND BASE OF HYDRANTS. MEGA -LUGS (OR SIMILAR PRODUCT) MAY BE REQUIRED ON ALL MECHANICAL JOINTS IN ADDITION TO CONCRETE BLOCKING. 7. ALL NEW WATER MAIN PIPES AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM PRIOR TO BEING FLUSHED, DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURITY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR. THE CONTRACTOR SHALL SUPPLY, INSTALL AND REMOVE PLUGS, CORPORATION STOPS, BLOW -OFF ASSEMBLIES, AND THRUST RESTRAINT / BLOCKING FOR TESTING AND PURITY ACCEPTANCE. NO CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET -TAP VALVE TO AN EXISTING MAIN UNTIL THE NEW PIPING HAS BEEN FOAM -PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURITY TESTING. 8. NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL BE TESTED AT A STATIC PRESSURE OF 150 PSI ABOVE WORKING PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSI PRESSURE DROP DURING THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURE TEST, THE LINE SHALL BE DISINFECTED, FLUSHED, AND THEN WATER SAMPLES SHALL BE TAKEN FOR PURITY TESTING BY THE PUBLIC WORKS INSPECTOR. 9. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER UTILITY AND MAINTENANCE DEPARTMENTS AT LEAST 10 WORKING DAYS PRIOR TO MAKING CONNECTIONS TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL EXPOSE THE EXISTING WATER MAIN AND FITTINGS AT THE CONNECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS REQUIRED FOR THE FINAL CONNECTION. THE CONTRACTOR SHALL EXCAVATE, REMOVE ALL SURFACE MATERIALS, AND PROVIDE SHORING AND ALL MATERIALS REQUIRED FOR THE CITY OF RENTON TO PERFORM THE CONNECTION TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL PROVIDE AND INSTALL BACKFILL, CONCRETE BLOCKING, AND COMPLETE SURFACE RESTORATION BUSH, ROED & HITCHINGS, INC. LAND SURVEYORS & CIVIL ENGINEERS 2009 MINOR AVE. EAST (206) 323-4144 SEATTLE, Washington 1-800-935-0508 98102-3513 FAX# (206) 323-7135 WATER UTILITY NOTES AND SPECIFICATIONS: 1. ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 PM ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AT 430-7301. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ANY WORK IN THE RIGHT OF WAY. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATES CALL 48-HOUR LOCATORS 800-424-5555. 4. AN APPROVED TRAFFIC CONTROL PLAN IS REQUIRED TO BE SUBMITTED AT THE PRE -CONSTRUCTION MEETING. 5. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 6. ALL WATERMAIN PIPE IS TO BE CEMENT LINED DUCTILE IRON PIPE CONFORMING TO AWWA C110 AND C111 OR LATEST REVISION, THICKNESS CLASS 52. CEMENT MORTAR LINING AND SEAL COATING SHALL CONFORM TO AWWA C104 OR LATEST REVISION. PIPE JOINTS TO BE PUSH -ON OR MECHANICAL BEDDING TO BE CLASS C. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE POLYETHYLENE WRAPPED PER ANSI/AWWA C105/A21.5-93 STANDARDS. 7. CAST IRON AND DUCTILE IRON FITTINGS SHALL BE CEMENT LINED, PRESSURE RATED AS NOTED ON PLANS, AND IN ACCORDANCE WITH ANSI/AWWA C110/A21.10-87. CEMENT LINING SHALL BE IN ACCORDANCE WITH ANSI/AWWA C104/421/4-90. IF FITTINGS ARE 3 TO 12 INCHES IN DIAMETER AND HAVE MECHANICAL JOINTS, THE FITTINGS SHALL IN ACCORDANCE WITH EITHER ANSI/AWWA C110-A21.10-87 OR ANSI/AWWA C153/A21.53-94. THREE (3) INCH TO 12 INCH DIAMETER FITTINGS, WHICH HAVE MECHANICAL JOINTS AND/OR FLANGED JOINTS, SHALL BE IN ACCORDANCE WITH ANSI/AWWA C110/A21.10.87 OR A COMBINATION OF ANSI/AWWA C110/A21.10.87 AND ANSI/AWWA C153/A21.53-94 SUCH THAT THE PORTION OF THE FITTING WITH A MECHANICAL JOINT(S) MAY BE WITH ANSI/AWWA C153/A21.53-94 AND THAT PORTION OF THE FITTING WITH FLANGED JOINT(S) SHALL BE IN ACCORDANCE WITH AWWA C110/A21.10-87. ACCEPTANCE TESTING IN ACCORDANCE WITH SECTION 53.53 OF ANSI/AWWA SECTION 10-4.3 OF ANSI/AWWA C110/A21.10-87 SHALL BE OBTAINED BY THE CONTRACTOR AND TRANSMITTED TO THE OWNER. 8. GATE VALVES SHALL BE IRON BODY, BRONZED -MOUNTED, DOUBLE DISC WITH BRONZE WEDGING DEVICE AND 0-RING STUFFING BOX (AWWA C500) OR OF RESILIENT SEATED TYPE (AWWA C509). VALVES SHALL BE DESIGNED FOR A MINIMUM WATER OPERATING PRESSURE OF 200 PSI. GATE VALVES SHALL BE CLOW LIST 14, MUELLER COMPANY NO. A2380 OR M & H. 9. FIRE HYDRANTS SHALL BE COREY TYPE (OPENING WITH THE PRESSURE) OR COMPRESSION TYPE (OPENING AGAINST PRESSURE) CONFORMING TO AWWA C-502-85 WITH A 6 INCH MECHANICAL JOINT INLET AND A MAIN VALVE OPENING (M.V.O.) OF 5-1/4 INCH, TWO 2-1/2 INCH HOSE NOZZLES WITH NATIONAL STANDARD THREADS 7-1/2 THREADS PER INCH AND ONE 4 INCH PUMPER NOZZLE WITH THE NEW SEATTLE PATTERN 6 THREADS PER INCH, 60 DEGREES V. THREADS: OUTSIDE DIAMETER OF MALE THREAD 4.875 AND ROOT DIAMETER 4.6263. HYDRANTS SHALL HAVE A 1-1/4 INCH PENTAGON OPERATING NUT OPENED BY TURNING COUNTER CLOCKWISE (LEFT). 10. THE TWO 2-1/2 INCH HOSE NOZZLES SHALL BE FITTED WITH CAST IRON THREADED CAPS WITH OPERATING NUT OF THE SAME DESIGN AND PROPORTIONS AS THE HYDRANT STEM NUT. CAPS SHALL BE FITTED WITH SUITABLE NEOPRENE GASKETS FOR POSITIVE WATER TIGHTNESS UNDER TEST PRESSURES. 11. THE 4 INCH PUMPER NOZZLE SHALL BE FITTED WITH A STORZ ADAPTER, 4 INCH SEATTLE THREAD X 5 INCH STORZ. STORZ ADAPTER SHALL BE FORGED AND/OR EXTRUDED 6061-T6 ALUMINUM ALLOY, HARDCOAT ANODIZED. THREADED END PORTION SHALL HAVE NO LUGS AND TWO SET SCREWS 180 DEGREES APART. STORZ FACE TO BE METAL, NO GASKET TO WEATHER. STORZ CAP TO HAVE SYNTHETIC MOLDED RUBBER GASKET, AND SHALL BE ATTACHED TO HYDRANT ADAPTER WITH 1/8 INCH, COATED, STAINLESS STEEL, AIRCRAFT CABLE. 12. FIRE HYDRANTS SHALL BE PAINTED WITH TWO COATS OF PAINT. PRESERVATIVE PAINT NUMBER 43-655 SAFETY YELLOW OR APPROVED EQUAL. SURVEYED: SCALE: JMH DESIGNED: AS SHOWN ZJE DRAWN: ZJE ONE INCH CHECKED: AT FULL SCALE TFD IF NOT ONE INCH NO. REVISION BY DATE AP P R APPROVED: TFD SCALE ACCORDINGLY WATER UTILITY NOTES AND SPECIFICATIONS (cont.): 13. PUMPER CONNECTION TO FACE ROADWAY ASSEMBLY. 14. FIRE HYDRANTS SHALL BE INSTALLED PER CITY OF RENTON STANDARD DETAIL FOR FIRE HYDRANTS, LATEST REVISION. 15. ALL WATERMAINS 10 INCHES AND SMALLER TO MAINTAIN A MINIMUM COVER OF 36 INCHES BELOW FINISH GRADE. ALL WATERMAIN 12 INCHES AND LARGER SHALL BE AT A MINIMUM OF 48 INCHES BELOW FINISH GRADE. WHERE UTILITY CONFLICTS OCCUR, WATERMAINS ARE TO BE LOWERED TO CLEAR. 16. ALL WATERMAINS 6 INCHES AND LARGER IN DIAMETER SHALL BE CLEANED WITH PIPE CLEANING 'PIGS" PRIOR TO DISINFECTION. THE 'POLY PIGS" SHALL BE GIRARD INDUSTRIES AQUA SWAB -AS OR APPROVED EQUAL, 2 LB/CU. FT. DENSITY FOAM WITH 90A DUROMETER URETHANE RUBBER COATING ON THE REAR OF 'PIG" ONLY. 17. 'PIGS" SHALL BE CYLINDER SHAPED WITH BULLET NOSE OR SQUARE END. THE CONTRACTOR WILL PERFORM THE CLEANING OPERATION. 18. ALL WATERMAINS AND SERVICES SHALL BE PRESSURE TESTED TO A MINIMUM OF 200 PSI OR 150 PSI OVER OPERATING PRESSURE, IN ACCORDANCE WITH THE SPECIFICATIONS OF THE CITY OF RENTON AND THE WASHINGTON STATE HEALTH DEPARTMENT. ALL PRESSURE TESTING SHALL BE DONE IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY OF RENTON. THE QUANTITY OF WATER LOST FROM THE MAIN SHALL NOT EXCEED THE NUMBER OF GALLONS PER HOUR AS LISTED IN CITY OF RENTON STANDARD PLANS & SPECIFICATIONS 7-11.3(11). THE LOSS IN PRESSURE SHALL NOT EXCEED 5 PSI DURING THE 2 HOUR TEST PERIOD. 19. ALL WATERMAINS AND SERVICES SHALL BE DISINFECTED BY THE INJECTION OF A 50 PPM (MINIMUM CONCENTRATION) CHLORINE/WATER SOLUTION. DRY CALCIUM HYPOCHLORITE SHALL NOT BE PLACED IN THE PIPE AS LAID. CHLORINE SHALL BE METERED/INJECTED IN ACCORDANCE WITH SECTION 7-11.3(12)E OR 7-11.3(12)F OF THE STANDARD SPECIFICATIONS REFERENCED ABOVE. A PRE -CONSTRUCTION CONFERENCE IS REQUIRED PRIOR TO ANY CONSTRUCTION. A MINIMUM OF FIVE WORKING DAYS NOTICE IS REQUIRED FOR SCHEDULING. 20. TWENTY-FOUR (24) HOURS NOTICE WILL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. 21. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. 22. INSTALLATION OF CORPORATE STOPS, WATER SERVICES, LINES AND METERS SHALL NOT BE DONE UNTIL ALL SERVICE AGREEMENTS, METER APPLICATIONS, CONSTRUCTION PERMITS, AND PAYMENT OF FEES HAVE BEEN MADE TO THE CITY OF RENTON. 23. ALL CONNECTION TO EXISTING MAINS IS TO BE ACCOMPLISHED BY THE CITY OF RENTON, EXCEPT WET TAPS, WHICH MAY BE MADE BY APPROVED WET TAP CONTRACTORS WITH PRIOR APPROVAL FROM THE PUBLIC WORKS DEPARTMENT. ALL NECESSARY EXCAVATION AND MATERIALS ARE TO BE SUPPLIED BY THE CONTRACTOR AND BE ON -SITE PRIOR TO CITY NOTIFICATIONS. 24. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY DEVELOPMENT SERVICES TWENTY FOUR (24) HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. THE CONTRACTOR, AS WELL AS THE ENGINEERS, SHALL KEEP AS -BUILT DRAWINGS. 25. CONTRACTOR TO PROVIDE PLUGS AND TEMPORARY BLOW -OFF ASSEMBLIES FOR TESTING AND PURITY ACCEPTANCE PRIOR TO FINAL TIE-IN. 26. ALL JOINT RESTRAINT SYSTEMS (SHACKLE RODS, NUTS, BOLTS, ETC.) SHALL BE AS MANUFACTURED BY THE STAR MANUFACTURING COMPANY OF COLUMBUS OHIO, OR EQUAL, APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT. 27. ASPHALT AND CONCRETE STREET PAVING SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) OIL MAT STREETS MAY BE SPADE CUT. ALL SURFACE CONCRETE, PAVEMENT, SIDEWALKS, CURB, GUTTERS, AND DRIVEWAY APPROACHES SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES OR REMOVED TO AN EXISTING EXPANSION JOINT. 29. A TEMPORARY COLD MIX ASPHALT PATCH SHALL BE PLACED ON THE DAY OF INITIAL EXCAVATION WITH A PERMANENT, SEALED PATCH TO BE PLACED, TO CITY OF RENTON POLICY, WITHIN 10 DAYS. CALL FOR SUBGRADE INSPECTION PRIOR TO PLACEMENT OF FINAL PATCH. * 30. FOR CITY PROJECTS SUCH AS TELEMETRY CONDUIT, THE PVC PIPE USED SHALL BE ALL CHEMICAL PROCESS LINES SHALL BE SCHEDULE 80 PVC PIPE. SCHEDULE 40 IN UNIMPROVED AREAS AND SCHEDULE 80 PVC PIPE UNDER IMPROVED AREAS HORIZONTAL- NAD 1983/1991 CITY OF 10 RENTON DATUM Planning/Building/Public Works Dept. AS -BUILT CERTIFICATION: I HEREBY CERTIFY THAT THE HORIZONTAL AND VERTICAL LOCATION OF THE STORM DRAINAGE STRUCTURES AND THE HORIZONTAL LOCATION OF THE WATER SURFACE FEATURES SHOWN HEREON AND SHOWN IN BOLD IS THE RESULT OF A FIELD S- PERFORMED BY ME OR UNDER�IRECTION. TED DIMOF, P. 0. 024 12/6/18 DATE THE ENGINEER OF RECORD CERTIFYING THESE RECORD DRAWINGS HAS NOT WITNESSED ALL ELEMENT OF CONSTRUCTION AND IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN DATA PROVIDED BY THE CONTRACTOR OR THE SURVEYOR OF RECORD. IN COMPLIANCE WITH CITY OF RENTON STANDARDS NOTES SHEET US BANK EXPANSION 2500 EAST VALLEY ROAD RENTON, WASHINGTON 98057 STRADA DA VALLE DATE: 12/6/2018 FIELDBOOK: PAGE: SHEET: n 2 OF. 1 1 R-396702 SURVEY NOTES: REFERENCES: 0') HORIZONTAL DATUM: — RECORD OF SURVEY, REC. NO. 8202189001 C WASHINGTON COORDINATE SYSTEM, NAD 83/91, NORTH ZONE, — RECORD OF SURVEY, REC. NO. 9111089007 pI PER CITY OF RENTON HORIZONTAL SURVEY CONTROL NETWORK. — RECORD OF SURVEY, REC. NO. 9509059008 Nt — RECORD OF SURVEY, REC. NO. 9606199001 0 VERTICAL DATUM: — RECORD OF SURVEY, REC. NO. 9902129009 NAVD 1988 — CITY OF RENTON HORIZONTAL SURVEY CONTROL W NETWORK BASIS OF BEARINGS: — WSDOT SR167 HIGHWAY MAP — S. 228TH. TO CITY OF RENTON HORIZONTAL CONTROL POINT NUMBERS 1160 AND 230, RENTON SOUTH 89'58'08" EAST 2659.31' (CALCULATED AND MEASURED). INSTRUMENT: SET 5/8" REBAR THIS SURVEY WAS PERFORMED WITH A LEICA TCR 1105 TOTAL STATION, & CAP SERIAL NO. 621961, AND A LEICA GPS1200 SURVEYING SYSTEM SERIAL NO. 160230. LS#44634 (TYP.) PRECISION: ~ PRECISION EXCEEDS 1:10,000 GROUND TRAVERSE METHODS AND WERE IN ACCORDANCE WITH WAC 332-130-090. FIELD SURVEY: A/C THE FIELD SURVEY WAS PERFORMED JUNE 2008. ANGLES AND DISTANCES SHOWN HEREON ARE ON GROUND, UNLESS OTHERWISE NOTED. SR 6-7 SECTION SUBDIVISION: TRASH SUBDIVISION OF SECTION 30, TWP. 23N, RGE. 5E, WAS CALCULATED PER RECORD OF "REC, ENCLOSUB_E Qrg6.6$ — SURVEYS NOS: 8202189001 AND 9111089007". d _ _ _ �68- NO PARKING — SIGN PCC \FIRE LANE" / I lb _ w_----- 1 1 11 1\ L -- L �° _00000cn -�� W �-- 1 1 1 1 ICOP RS 1 1 1\z 1 1 _:� Gw \ _ -- A/C—► �� 1 1 1161 f� �— \/� a_ a- - — — o s ° 96 1 \ \\ \ \ \ \ 1 3 � P RKING -17CC 1 Sl 6„ CC� 4 12°2 X 2 �� WLANE SIGN 1 1 1 COP IP 1 1 \ �o .,�°A°� I°� ��° 8 �b� 1 11 11 1 1 1 vy s I �0 d- — XI x 1 _ 0� x ��PCC I ® hose 0 ° 1C -- "HANDICAP I 8 3N_ PARKING" �o �° z I on 2 6 1.� �� i SIGN — L U PCC , — s I o 0 0 ?>> .,....,. � ,,,.......'i I I- ��� s' ................� �I 1p o LOT 3 — I � � I cn I — — a_ I �� 134,074 SQ. FT. �- �—cn 3.0779 ACRES 0 -fi I _ �_ U -° o .R D� ti��� 2500 EAST VALLEY RD N I _ — —�—I s o l 0 N ID o 00 2 I I r7 �' y "HANDICAP "COURIER PARKING — N i = PARKING" — PCC ONLY" SIGN SIGN- ti ryo. j-- --00 s S' — 00 re x A cn ju �o, �, �° I �° I o P CC �°10 -- "N-0 PARKING-- x _ — I �X I — G _ CW CW — 6„ CC FIRE LANE;o. IGf�I°� — �� 8 x I �0 1 00 I ICO�iC I Ivy vv v { "NO PARKING" — ET o.7 � IN 20.23 I �e° 20� �I �'��6 4 � � I I I I I 115 I STCb P� I I IBEf�CH 4 TD � \ � SIGN 5 STD —�— EC°off s 2 X o zo °o E" o I\/LTI I I I I I I I I I I I ti o o c EVgPCC DS D.. i 9�1 99 I I x x � g 97 ° Ix 110 ST PFr I I I U U °o 11 s I I I's SWALE _ — — -- 1217.039 ---Ts - - --- - CW CD CW W — W --- — 1316.96'(C) w 1316.95'(C) H' rch'i ORq� tip, SEAL z 1969 �qSF� I F g ORN EAST VALLEY ROAD PCC I I 110 1 ST4 PS I I I I I I I I I I I I -----4q.5_q.V SWALE 0 jH — J P "SPEED LIMI1 35" SIGN BUSH, ROED & HITCHINGS, INC. LAND SURVEYORS & CIVIL ENGINEERS 2009 MINOR AVE. EAST SEATTLE, Washington 98102-3513 (206) 323-4144 1-800-935-0508 FAX# (206) 323-7135 era p co �J PIS PS — _ I SD SID �1 _ c3 SD I I I I I I I \ I 10 STD PS I I � „i ,18 , CC, I\ I — — — — — — — — — PCC I �' I� 7 STD PS I v I I „I 1 18 CC —r ----_— - I CW z CW A/C—� W WEST LINE NW 1 /4, ROW CENTERLINE NE 1 /4, SECTION 30 EAST VALLEY RD.ROW LINE (TYP.) REVISION p cn z 0 U Z U Ld w cfl p p i p Z w 0 Z � J cn Q Of 0 A/C CONIC. BEN ROW LINE (TYP.) — 0) IN A/C 6' CHAIN LINK FENCE ON 12" CONC. RET. WALL ^ Ld wLO LUMBER YARD 00 0 8' WOOD BOARD FENCE �0 Z �0 z �- U U w w U Z (n J D A/C 0 LIB cn z ROW LINE TS _ �� ®(TYP.) _ /l? _CD i1 —� S 01 °49'52" W 131 & ROW MONUMENT E. VALLEY HWY.--,/ FND. 1-3/4 BRASS DISC W/"+" �— IN CONC. MON IN CASE, . V) DOWN 0.4', VISITED 6-25-08 EAST 0.05' OF CALC. INTERSECTION AS -BUILT CERTIFICATION: I HEREBY CERTIFY THAT THE HORIZONTAL AND VERTICAL LOCATION OF THE STORM DRAINAGE STRUCTURES AND THE HORIZONTAL LOCATION OF THE WATER SURFACE FEATURES SHOWN HEREON AND SHOWN IN BOLD IS THE RESULT OF A FIELD SU PERFORMED BY ME OR UNDER�MIRECTION. TED DIMOF, P. 0. 024 12/6/18 DATE THE ENGINEER OF RECORD CERTIFYING THESE RECORD DRAWINGS HAS NOT WITNESSED ALL ELEMENT OF CONSTRUCTION AND IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN DATA PROVIDED BY THE CONTRACTOR OR THE SURVEYOR OF RECORD. SURVEYED: JMH DESIGNED: ZJE DRAWN: ZJE CHECKED: TFD BY DATE APPR APPROVED: TFD SCALE: AS SHOWN ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY N vERnCAL: NAVD 19a8 HORIZONTAL- NAD 1983/1991 DATU M CITY OF RENTON Planning/Building/Public Works Dept. LEGEND 19 20 SECTION CORNER 19 QUARTER SECTION CORNER 30 O SURVEY MONUMENT A/C ASPHALTIC CONCRETE PAVEMENT BSBL BUILDING SETBACK LINE (C) CALCULATED ® CATCH BASIN CC CONCRETE CURB CD CONCRETE DRIVE PCC PORTLAND CEMENT CONCRETE PAVEMENT CW CONCRETE WALK EC ELECTRICAL CONDUIT ELEC. ELECTRICAL ❑ ET ELECTRICAL TRANSFORMER REV ELECTRICAL VAULT FIRE DEPARTMENT CONNECTION FIRE HYDRANT FT. FEET G GAS MAIN E51 GAS METER $ GAS VALVE &• HANDICAP PARKING SPACE ®IRR IRRIGATION CONTROLLER LIGHT POLE WALK LIGHT NO. NUMBER O/H P OVERHEAD POWER _< OUTFALL OWS OIL/WATER SEPARATOR PS PARKING STALL STD STANDARD COMP COMPACT C4 POST INDICATOR VALVE REC. RECORDING RET. RETAINING SD STORM DRAIN Q STORM DRAIN MANHOLE �- SIGN SQ. SQUARE SS SANITARY SEWER Qs SANITARY SEWER MANHOLE ® STREET LIGHT JUNCTION BOX TIC TELECOMMUNICATIONS CONDUIT TELECOMMUNICATIONS SENTRY oS TVLT TELECOMMUNICATIONS VAULT UTILITY POLE W WATER MAIN ® WATER METER % WATER VALVE Z30 15 0 30 60 SCALE IN FEET 1 "=30' IN COMPLIANCE WITH CITY OF RENTON STANDARDS HORIZONTAL CONTROL AND TOPOGRAPHY PLAN �1:2/6/2018 US BANK EXPANSION FIELDBOOK: 2500 EAST VALLEY ROAD PAGE. DRAWING N0: RENTON, WASHINGTON 98057 STRADA DA VALLE SHE: C3 OF. 1 1 R-396703 TRASH — ENCLOSU.R� ' rpS' SID , - o — — - ----� "NO PARKING - �� \ PCC — EX FH I �--____--- `\FIRE LANE" SIGN LJ ~ EX CB IN DRAINAGE AREA WETLAND BOUNDARY 6 I �5 I I -- --- i I °.. --- _ ?.0 TYP 1 — — _ _ — _ —'C� , �I 116 IICO�P II I a \ \ I ?Oa?--- /• Rs BTM:1g60 ?o-- zo,4 1 ?O—RK�NG ----C 1 I I I 1\\ U\ o NN^ �1 6ff CC �--�2s I ?o?S ?o? �,fd- »NO P A - SOA P J I I I P cV�--- _ _ ^ a ° ° \ x 1 x, _—_ �ANU 1 I �/ 1 dv � I I I g a'. \ \\ RE 11/I\\JJ — — — — ---- I N � O ?O O'Sx? NN21.11 I1 I I I I I a.V Onx X � \ — a -�--� P C C I 1 ?p S? °9T ° I I 1 ° A ° " S ?p 9 a °. HANDICA ° • f g 39 - - - - - -=-< - -.---I- e 20.9� 1:40 ° SS. ° . PARKING I � I PCC __N•s ?,s -�,ss '��I I o� SS i ryOb.x4�bb COVE EX PARKING IPING IN VICINITY_ OF ?� BUILDING ADDITION —' U ' 'I` 6� R FFE:21.67 LOT 3 IPROPSED 10" WATER -� — — G �a l..: ISEE SHEETS C8 AND C9 134,074 SQ. FT. r 1 1 3.0779 ACRES I PRO SED � BL U I 2500 EAST VALLEY RD 0 G� ,G a °.. I U I I �D ° ----I 1 v d " ' a 1 a 0 _ T I —un ° U I ?o LIJ p- ....�X s I ADDITIONIn - — — LOT L 0 00 °Ie I a I , 1 7.5o "HANDICAP HANDICA )f COURIER PARKIN o a _17-515,508 SQ. FT. _ _ 0 ' — I FFE:21.56 PARKING" ONLY" SIGN 1 .2RI rACRES ? I--e. N a I 2400 EAST VALLEY RD o p �Ax I ryo. I 40.00' / / a °. a ---I- I --- a M — — 00 00 --�— a \. 'C � O v O. ; Q 0 ° � .. V. I — — 1- ° NE BA PAW BOLL RD YP.) - 0_ �_— PARKING -=OW A .' 'III 8 P. (may a e 1 'L/'�/ a. .�j ,'..? a. ° ,. a °.' .' a'. ° °, °'° C'W ° ` ° a °.a. a '° ° .41 ° a �' °. v . ° a.. v .gip .� °. ° a v -- - I --- "IGN �� FIRE LANE" 7 M 1 1)° o I sue'—.� o� J Q I ., '' ° N a II I a e e aFl 3 C.�PAVE�ENT REP AC ERA "J;°' I �t I I I I I I 61 PCC{ / 61 CSPC I I I I I I I 0 MATCH X DEPTH R I I I I I I I I I` I I I I ICOf�C. I L I I I 4 TD IBEW H I I I f �\� I ff ff h ��`�\ `I NO PARKING y SIGN —_� I EX FH 5 20.; ryol EX FH I I I I I I I I I I LP ° a o e a G OgHITCy 0Rq��y� SEAL z m 1969 �gSF11 m �.. �' -' �o, 15 S TC P � � � 5 STD I — �. �. po, ?° C VER IS GREATER I I I I I I I I `I I PIS I I I J S _ °�_ 's ..: a o L I I I I I I I I I I I L\J I I I PS I I D 11 °X PCC? ''11-1 N _ — DC _ S D� c Ste x I CB TYP 2 CB TYP 2 RIM:20.08 I I U RIM: 20.18 P C, C (N)IE:12.88 30" CONC PCC (N)IE:13.18 36" CONC U ?Oop I �y 9A (S)(APROX)IE:12.89 30" CONC (E)IE:14.98 6" PVC x BT :11.18 E CB IN DR INA E AR A (S)IE:1�3.43 36" CONC g2 i i i 10 i T[ P �CB TYf� 1 i 10 1 N P j i I I BTM:1Q.88 I I �I 17 7— 1 1 7 STD P S I 1 I I U e RIM:19 00 1 II I I I I ry 9� I I I I I I 10 STD PS I I I II I II I I I 1 I `�� e' II I I I (w)IF�:18.30 (2) 4" DI d I I I I I I I s �TM:17I6o I I I I I I I I I U I I `� � �9 �9 �9 — I 1 I f f � I I I I I I I I "I I I I U U ??p II s II I I I — I I I 118 CC I =I 18 CC I= I U 1 -- — — —— — — P ----------- � co .---- ------- co ---32, --- --- ---♦ 217.03'oTS�-------SWALE--O�-P---- d °. ° /-\ ^ v ° e ' a ° I c .v w a. O 4 °. Q a ° . a i `� ° v ° a. ° ° 'Q v ° —W -- xw — W U — — 1316.96 (C) EAST VALLEY ROAD 1316.95'(C) "SPEED LIMIT 0 35" SIGN ul EAST VALLEY ROAD to BUSH, ROED & HITCHINGS, INC. LAND SURVEYORS & CIVIL ENGINEERS 2009 MINOR AVE. EAST SEATTLE, Washington 98102-3513 (206) 323-4144 1-800-935-0508 FAX# (206) 323-7135 NO. REVISION A/C o z w U Ir__ U w 0 Q0 oz IW 0 z °- J cn 0 A/C CONC. BEN�t ' 6' CHAIN LINK FENCE ON 12" CONC. RET. WALL w w w In N In 0 00 U) 8' WOOD BOARD FENCE o z �0 zu U Li LL1 U J CO � o A/C w cn z --- -- -- — ___ --- __- --- -- _ _---- __-- _ ___ -- = - -- --- W -E TSo -31� +-L ROW LINE ®� ° (TYP . ) v ° a .. ° 'a v V av x r A • / o f ff A C o A C S 014952 W cn / EX FH ROW MONUMENT E. VALLEY HWY. 4, ROW CENTERLINE FND. 1-3/4 BRASS DISC W "+" WEST LINE NW 1 / EAST VALLEY RD. IN CONC. NE 1 /4, SECTION 30 ROW LINE DOWN 0.4', IN COMPLIANCE WITH CITY OF RENTON STANDARDS (TYP.) EAST 0.05' Z20 10 0 20 40 \ SCALE IN FEET 1 "=20' SCALE: AS SHOWN ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL- NAVD 19M HORIZONTAL• NAO 1983/1991 DATU M CITY OF RENTON Planning/Building/Public Works Dept. SITE PLAN US BANK EXPANSION 2500 EAST VALLEY ROAD RENTON, WASHINGTON 98057 STRADA DA VALLE DATE: 12/6/2018 FIELDBOOK: PAGE: R-396704 w Q z - FIRE LANE CATCH BASIN FILTERS (TYP.)wowi - 6 CC PS C� _- CAMP - - cs TYP 1 16 ° 10 v RIM:1g• 40 17- C5 14� - _ a o. � PCCNG a • a ° 6,> OC � -ENO PAR S1 N ���P PS a E LANE (SAND BAGS AS NECESMATER a VENT a , a°. FAR CONSTRUCTI TORM AASIN EX CIB T T L L PCC E T d: �,�N °�. ° a p " LO �- .. � HANDICA • °. a .. n / PARKING SIGN P CC N I i. ......... � •` .. � N I� 4 LIMITS OF BLDG ADDITION PROJECT LIMITS LOT 3 cn I U ---� II / I 134)074 SQ. FT. j c- - - -II I I I. EX SIDEWALK AND CURB TO BE REMOVED 3.0779 ACRES ---111 10I NEW CURB (TY .10 III 1 2500 EAST VALLEY RD ---D SEDIMENT TRAP W/ SUMP PUMP A MINIMUM WATER SURFACE AREA=92 SF I..�.J I RELOCATE AS NECESSARY DURING CONSTRUCTION - "HANDICAP ° II I �� STAGING AS DIRECTED BY CSWPP LEAD "COURIER PARKIN iFFE:21.56 PARKING" ONLY" SIGN CD I - -� I� I N I � oa EX,,GdRB TO BE ---- _I OVED (TYP.) PUMP LINE -.A EX SDMH 10 PARKING - -- - CW 6CC f.cw . �� „ RE LANE SIGN - _ J NEW CURB (TYP.) CONC. \ "NO PARKING' __ ° a � I L SIGN 5 STD � � � 1 15 STD PS BENCH �� -_ - - WVL I PS y PS PCC \ X CURB TO BE C[� -EX FH TO RF REMOVED._ � _ D SEE -WATER PLANS.-- D REM c6 T 2 CB TYP 2 Ll. VAULTMTU-IRE AI RIM:20.08 Llr. VHIJ 1 0 C PCC (N)IE:13.18 36" CONC P C C C STRAW WATTLE AS NECE SARY TO RE E LID 4�OUTE9Nc (E)IE:14.98 6" PVC \ PREVENT CONS RUCTION STO WATER '-- LID PROP4191C1,RADES. (S)IE:13.43 36" CONC FRO BYPASSIt�IG EX CB TO SW a BTM:10.88 7 STD PS 10 STD ' CB TYP 1 10 STD P S - I RIM:19.00 (W)I 18.30 (2) 4" DI 8 . 10 STD P S \ I U J BTM:17.60 1 8„ CC I 18 CC \ 7 ---------- 49 5.9 3'----------- - ----- LIP------ _---------- --- ------ ------------------- --- 32 Lam TS SWALE --- --- W - -- --- �v 3 a ° a I • -'d v. n ° LEGEND: STRAW WATTLE CATCH BASIN PROTECTION LIMITS OF CLEARING FOUNDATION EXCAVATION LIMITS - - St H' rc'yi 0R,9� SEAL 1969 kgSH I NGA F g A 02 � 'po CIS �' 11 U ORN CONTRACTOR NOTES: 1. CONTRACTOR TO PREVENT ALL CONCRETE WASH FROM ENTERING STORMWATER SYSTEM. ALL CONCRETE WASH SHALL BE DIRECTED TO FORMED AREAS AWAITING CONCRETE OR ASPHALT. 2. CONTRACTOR SHALL LIMIT DUST GENERATION AND SPRINKLE UNCOVERED AREAS AS NEEDED. 3. THIS PROJECT IS SUBJECT TO RAINY SEASON REQUIREMENTS. SPECIAL APPROVAL FROM THE CITY OF RENTON IS REQUIRED TO BEGIN OR CONTINUE CLEARING AND GRADING ACTIVITIES DURING THE RAINY SEASON (OCTOBER 1 THRU APRIL 30) 4. ALL SLOPES ON SITE SHALL BE MAINTAINED AT MAXIMUM 2H:1V 5. SEE LANDSCAPE PLAN L1.0 FOR TREE RETENTION PLAN BUSH, ROED & HITCHINGS, INC. LAND SURVEYORS & CIVIL ENGINEERS 2009 MINOR AVE. EAST SEATTLE, Washington 98102-3513 (206) 323-4144 1-800-935-0508 FAX# (206) 323-71 35 ml REVISION SURVEYED: JMH DESIGNED: ZJE DRAWN: ZJE CHECKED: TFD BY DATE AP P R APPROVED: TFD Z20 10 0 20 40 SCALE IN FEET 1 "=20' EROSION CONTROL NOTES: 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON, PUBLIC WORKS DESIGN ENGINEER. 2. ALL LIMITS OF CLEARING AND AREAS OF VEGETATION PRESERVATION AS PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY FLAGGED IN THE FIELD AND OBSERVED DURING CONSTRUCTION. 3. ALL REQUIRED SEDIMENTATION/EROSION CONTROL FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO ENSURE THAT SEDIMENT LADEN WATER DOES NOT ENTER THE NATURAL DRAINAGE SYSTEM. ALL EROSION AND SEDIMENT FACILITIES SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT AND ADDITIONS TO EROSION/SEDIMENTATION CONTROL SYSTEMS SHALL BE THE RESPONSIBILITY OF THE PERMITEE. 4. THE EROSION AND SEDIMENTATION CONTROL SYSTEMS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE PERMITEE SHALL ANTICIPATE THAT MORE EROSION AND SEDIMENTATION CONTROL FACILITIES WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE PERMITEE TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL FACILITIES, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM. 5. APPROVAL OF THIS PLAN IS FOR EROSION/SEDIMENTATION CONTROL ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR RETENTION FACILITIES. 6. DURING THE TIME PERIOD OF OCTOBER 1ST THROUGH APRIL 30TH, ALL PROJECT DISTRIBUTED SOIL AREAS GREATER THAN 5,000 SQUARE FEET, THAT ARE TO BE LEFT UN -WORKED FOR MORE THAN 12 HOURS, SHALL BE COVERED BY MULCH, SODDING OR PLASTIC COVERING. 7. IN ANY AREA WHICH HAS BEEN STRIPPED OF VEGETATION AND WHERE NO FURTHER WORK IS ANTICIPATED FOR A PERIOD 30 DAYS OR MORE, ALL DISTURBED AREAS MUST BE IMMEDIATELY STABILIZED WITH MULCHING, GRASS PLANTING OR OTHER APPROVED EROSION CONTROL TREATMENT APPLICABLE TO THE TIME OF YEAR. GRASS SEEDING ALONE WILL BE ACCEPTABLE ONLY DURING THE MONTHS OF APRIL THROUGH SEPTEMBER, INCLUSIVE. SEEDING MAY PROCEED, HOWEVER, WHENEVER IT IS IN THE INTEREST OF THE PERMITEE, BUT MUST BE AUGMENTED WITH MULCHING, NETTING OR OTHER TREATMENT APPROVED BY THE CITY OF RENTON, OUTSIDE THE SPECIFIED TIME PERIOD. 8. FOR ALL EROSION/SEDIMENTATION CONTROL PONDS WHERE THE DEAD STORAGE DEPTH EXCEEDS 6 INCHES, A FENCE IS REQUIRED WITH A MINIMUM HEIGHT OF THREE (3) FEET, 3:1 SIDE SLOPES. 9. IF NECESSARY, A TEMPORARY GRAVEL CONSTRUCTION ENTRANCE, 24 FEET X 50 FEET X 8 INCHES OF 4 TO 8 INCH QUARRY SPALLS SHALL BE LOCATED AT ALL POINTS OF VEHICULAR INGRESS AND EGRESS TO THE CONSTRUCTION SITE. 10. DEVELOPER TO REMOVE ALL SEDIMENT CONTROL DEVICES AFTER CONSTRUCTION IS COMPLETE. GENERAL CONSTRUCTION SEQUENCE: 1. HOLD THE PRE -CONSTRUCTION MEETING. 2. POST SIGN WITH NAME AND PHONE NUMBER OF ESC SUPERVISOR (MAY BE CONSOLIDATED WITH THE REQUIRED NOTICE OF CONSTRUCTION SIGN). 3. FLAG OR FENCE CLEARING LIMITS. 4. INSTALL CATCH BASIN PROTECTION, IF REQUIRED. 5. INSTALL PERIMETER PROTECTION (SILT FENCE, BRUSH BARRIER, ETC.). 6. CONSTRUCT SEDIMENT TRAP. 7. CONSTRUCT SURFACE WATER CONTROLS (INTERCEPTOR DIKES, PIPE SLOPE DRAINS, ETC.) CALLED OUT ON THE PLAN SIMULTANEOUSLY WITH CLEARING AND GRADING FOR PROJECT DEVELOPMENT. 8. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH APPENDIX 'D' OF THE 2017 RENTON STORMWATER DESIGN MANUAL AND MANUFACTURER'S RECOMMENDATIONS. 9. RELOCATE EROSION CONTROL MEASURES, OR INSTALL NEW MEASURES SO THAT AS SITE CONDITIONS CHANGE, THE EROSION AND SEDIMENT CONTROL IS ALWAYS IN ACCORDANCE WITH THE CITY OF RENTON EROSION AND SEDIMENT CONTROL STANDARDS. 10. COVER ALL AREAS THAT WILL BE UNWORKED FOR MORE THAN SEVEN DAYS DURING THE DRY SEASON OR TWO DAYS DURING THE WET SEASON WITH STRAW, WOOD FIBER MULCH, COMPOST, PLASTIC SHEETING, OR EQUIVALENT. 11. STABILIZE ALL AREAS WITHIN SEVEN DAYS OF REACHING FINAL GRADE. 12. SEED, SOD, STABILIZE, OR COVER ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30 DAYS. 13. USE PERMENANT STORMWATER DETENTION AND WATER QUALITY FACILITIES TO CONTROL CONSTRUCTION STORMWATER ON -SITE FOR THE REMAINDER OF THE CONSTRUCTION SCHEDULE. 14. UPON COMPLETION OF THE PROJECT, STABILIZE ALL DISTURBED AREAS AND REMOVE BMPS IF APPROPRIATE. AS -BUILT CERTIFICATION: I HEREBY CERTIFY THAT THE HORIZONTAL AND VERTICAL LOCATION OF THE STORM DRAINAGE STRUCTURES AND THE HORIZONTAL LOCATION OF THE WATER SURFACE FEATURES SHOWN HEREON AND SHOWN IN BOLD IS THE RESULT OF A FIELDS PERFORMED BY ME OR UNDE�DIRECTION. TED DIMOF, P N0. 6024 12/6/18 DATE THE ENGINEER OF RECORD CERTIFYING THESE RECORD DRAWINGS HAS NOT WITNESSED ALL ELEMENT OF CONSTRUCTION AND IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN DATA PROVIDED BY THE CONTRACTOR OR THE SURVEYOR OF RECORD. SCALE: HORIZON AS SHOWN HORIZONTAL- NAD 1983/1991 ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY + CITY OF RENTON Planning/Building/Public Works Dept. IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEMOLITION AND TESC PLAN US BANK EXPANSION 2500 EAST VALLEY ROAD RENTON, WASHINGTON 98057 STRADA DA VALLE DATE: 12/6/2018 FIELDBOOK: PAGE: sHEU. C 5 OF. 1 1 R-396705 C'7 I O W I- 4' MIN V OVERFLOW DEPTH t'EDEPTiL2" �k .RS)CK � OUTFLOW j CHANNEL IF CONSTRUCTED BY S - 9 EXCAVATION. 2' SETTLING DEPTB 1 r 1 5'MAX SEDIMENT STORAGE FILTER FABRIC FENCING ,1' DEPTH 3/4" - 1-1/2" WASHED GRAVEL CROSS SECTION NTS NOTE: MAY BE CONSTRUCTED BY EXCAVATION OR BY BUILDING A BERM Y PUBLIC WORKS', SEDIMENT TRAP STD. PLAN — 211.00 DEPARTMENT MARCH 2O08 r g H'r�p ORq� tip, 1969 Sq iING F g 2 GIs � AL A I A 115 ORN 'r ADJACENT ROLLS SHALL TIGHTLY ABUT SEDIMENT, ORGANIC MATTER, ,\ AND NATIVE SEEDS ARE \\ ROLL SPACING CAPTURED BEHIND THE ROLLS DEPENDS ON SOIL TYPE AND SLOPE STEEPNESS VY/ STRAW ROLLS MUST BE PLACED ALONG SLOPE 1 CONTOURS ("-125mm) 8"-10" CIA. (200-250mm) LIVE STAKE NOTES 1" z i" STAKE 1. CONDITION OF USE 1.1. SEEDING SHALL BE USED THROUGH THE PROJECT ON DISTURBED AREAS THAT HAVE REACHED FINAL GRADE OR THAT WILL REMAIN UNWORKED FOR MORE THAN 30 DAYS. 1.2. VEGETATION -LINED CHANNELS SHALL BE SEEDED. CHANNELS THAT WILL BE VEGETATED SHOULD BE INSTALLED BEFORE MAJOR EARTHWORK AND HYDROSEEDED OR COVERED WITH A BONDED FIBER MATRIX (BFM) 1.3. RETENTION / DETENTION PONDS SHALL BE SEEDED AS REQUIRED. 1.4. AT THE CITY'S DISCRETION, SEEDING WITHOUT MULCH DURING THE DRY SEASON IS ALLOWED EVEN THOUGH IT WILL TAKE MORE THAN SEVEN DAYS TO DEVELOP AN EFFECTIVE COVER. 1.5. AT THE BEGINNING OF THE WET SEASON, ALL DISTURBANCES AREAS SHALL BE REVIEWED TO IDENTIFY WHICH ONES CAN BE SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHOULD BE SEEDED WITHIN A WEEK OF BEGINNING OF THE WET SEASON. AT FINAL SITE STABILIZATION, ALL DISTURBED AREAS NOT OTHERWISE VEGETATED OR STABILIZED SHALL BE SEEDED AND MULCHED. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. THE BEST TIME TO SEED IS APRIL 1 THROUGH JUNE 30, AND SEPTEMBER 1 THROUGH OCTOBER 15. AREAS MAY BE SEEDED BETWEEN JULY 1 AND AUGUST 31, BUT IRRIGATION MAY BE REQUIRED IN ORDER TO GROW ADEQUATE COVER. AREAS MAY ALSO BE SEEDED DURING THE WINTER MONTHS, BUT IT MIGHT TAKE SEVERAL MONTHS TO DEVELOP A DENSE GROUNDCOVER DUE TO COLD TEMPERATURES. 2.2. TO PREVENT SEED FROM BEING WASHED AWAY CONFIRMED_ THAT ALL REQUIRED SURFACE WATER CONTROL MEASURES HAVE BEEN INSTALLED. 2.3. THE SEEDBED SHOULD BE FIRM BUT NOT COMPACTED. 2.4. IN GENERAL, 10-20-20N-P-K FERTILIZER MAY BE USED AT A RATE OF 90 POUNDS PER ACRE. IT IS RECOMMENDED THAT AREAS BEING SEEDED FOR FINAL LANDSCAPING CONDUCT SOIL TO DETERMINE THE EXACT TYPE AND QUANTITY OF FERTILIZER NEEDED. DISTURBED AREAS WITHIN 200 FEET OF WATER BODIES AND WETLANDS MUST USE SLOW RELEASE LO-PHOSPHORUS FERTILIZER. 2.5. THE FOLLOWING REQUIREMENTS APPLY FOR MULCHING 2.5.1. MULCH IS ALWAYS REQUIRED FOR SEEDING SLOPES GREATER THAN 3H:1V 2.5.2. IF SEEDING DURING WET SEASON MULCH IS REQUIRED 2.5.3. THE USE OF MULCH MAY BE REQUIRED DURING WET SEASON AT THE CITY'S DISCRETION IF GRASS GROWTH IS EXPECTED TO BE SLOW, THE SOILS ARE HIGHLY ERODIBLE DUE TO SOIL TYPE OR GRADIENT, THERE IS A WATER BODY CLOSE TO THE DISTURBED AREA, OR SIGNIFICANT PRECIPITATION IS ANTICIPATED BEFORE THE GRASS WILL PROVIDE EFFECTIVE COVER. 2.5.4. MULCH MAY BE APPLIED IN TOP OF THE SEED OR SIMULTANEOUSLY BY HYDROSEEDING. 2.6. HYDROSEEDING IS ALLOWED AS LONG AS TRACKIFIER IS INCLUDED. HYDROSEEDING WITH WOOD FIBER MULCH IS ADEQUATE DURING THE DRY SEASON. HYDROSEEDING WITH WOOD FIBER MULCH IS ADEQUATE DURING THE DRY SEASON. DURING THE WET SEASON, THE APPLICATION RATE SHOULD BE DOUBLED. IT MIGHT BE NECESSARY IN SOME APPLICATIONS TO INCLUDE STRAW WITH THE WOOD FIBER, BUT THIS CAN BE DETERMINED TO GERMINATION. 2.7. AREAS TO BE PERMANENTLY LANDSCAPED SHALL USE SOIL AMENDMENTS. GOOD QUALITY TOPSOIL SHALL BE TILLED INTO THE TOP SIX INCHES TO REDUCE THE NEED FOR FERTILIZER AND IMPROVED THE OVERALL SOIL QUALITY. MOST NATIVE SOILS WILL REQUIRE THE ADDITION OF 4 INCHES OF WELL -ROTTED COMPOST TO BE TILLED INTO THE SOIL TO PROVIDE A GOOD QUALITY TOPSOIL. tiZY STD. PLAN — 213.40 PUBLIC WORKS' STRAW WATTLES 'AIVTO� DEPARTMENT MARCH 2O08, BUSH, ROED & HITCHINGS, INC. LAND SURVEYORS & CIVIL ENGINEERS 2009 MINOR AVE. EAST (206) 323-4144 SEATTLE, Washington 1-800-935-0508 98102-3513 FAX# (206) 323-7135 1. CONDITION OF USE 1.1. ,SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCHBASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 1.2. 1MAY BE USED ANYWHERE AT THE APPLICANT'S DISCRETION TO PROTECT DRAINAGE SYSTEM. 1.3. 'THE CONTRIBUTING DRAINAGE AREA MOST NOT BE LARGER THAN 1 ACRE. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. FILTER FABRIC IS ONLY ALLOWED WERE PONDING WILL NOT BE A TRAFFIC CONCERN AND WHERE SLOPE EROSION WILL NOT RESULT IF THE CURB IS OVERTOPPED BY PONDED WATER. 2.2. THE PLACEMENT OF A FILTER FABRIC UNDER GRATES IS GENERALLY PROHIBITED AND THE USE OF FILTER FABRIC OVER GRATES IS STRICTLY LIMITED AND DISCOURAGED. 3. MAINTENANCE STANDARDS 3.1. ANY ACCUMULATED SEDIMENT ON OR AROUND INLET PROTECTION SHALL BE REMOVED IMMEDIATELY. SEDIMENT SHALL NOT BE REMOVED WITH WATER AND ALL SEDIMENT MUST BE DISPOSED OF AS FILL ON SITE OR HAULED OFF SITE. tiZY � PUBLIC WORKS' FILTER FABRIC PROTECTION STD. PLAN — 216.20 DEPARTMENT MARCH 2008 SURVEYED: SCALE: JMH DESIGNED: AS SHOWN ZJE DRAWN: ZJE ONE INCH CHECKED: Al FULL SCALE TFD IF NOT ONE INCH NO. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY TFD vERnCAL: NAVD 19a8 HORIZONTAL" NAD 1983/1991 DATU M 0 CITY OF RENTON Planning/Building/Public Works Dept. AS —BUILT CERTIFICATION: I HEREBY CERTIFY THAT THE HORIZONTAL AND VERTICAL LOCATION OF THE STORM DRAINAGE STRUCTURES AND THE HORIZONTAL LOCATION OF THE WATER SURFACE FEATURES SHOWN HEREON AND SHOWN IN BOLD IS THE RESULT OF A FIELD SURVEY- PERFORMED BY ME OR UNDER M IRECTION. TED DIMOF, P. 0. 024 12/6/18 DATE THE ENGINEER OF RECORD CERTIFYING THESE RECORD DRAWINGS HAS NOT WITNESSED ALL ELEMENT OF CONSTRUCTION AND IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN DATA PROVIDED BY THE CONTRACTOR OR THE SURVEYOR OF RECORD. IN COMPLIANCE WITH CITY OF RENTON STANDARDS TESC DETAILS US BANK EXPANSION 2500 EAST VALLEY ROAD RENTON, WASHINGTON 98057 STRADA DA VALLE DATE: 12/6/2018 FIELDBOOK: PAGE: SHEET: C 6 OF.1 1 R-396706 It C'7 Lu I- w Q Z 4 H' rc'yi 0R,9� SEAL 1969 kgSHlN l •ss � ?O Zo ?'� -ROOF DRAINAGE FROM EASTERN `J JO < ' 0.99 21.40. PORTION, 0 DISTURBED AREA SHEET z,.ss FLOWS CATCH BASIN TO I I ° 21'04 �'+o 21.5Q SOUTFAS . `SEE SITE PLAN ON SHEET C4 �0 2 I. • J d., d a ,I p .� 9 64, pC O ) 2, � ? 71 I °' �O a I S O6 %S 1 a . .d •S X•d OS)X f I X e J °I 6 IajJ. °.9' ° �� ea/ `Y /•°e a/J-.Q I TC=21.15 X a d X 'A .TCi=21° 45° .. . BC=(20.6,5). I i s J d .C=(20.96) o1-(21 46) TC=21.15 ° 2O� I qi I d ° d / R I 'TC=21:19 / 17 8C ,20.69 . f°,a II tl 0 I 'd A d I I I/J tl J ° 20 �s2X ° I. ° 'd. EXISTING BUILDING BUILDING ADDITOIN FF-21.67 TC=21.10 BC=(20.60) °.. ; FF=21.67 �e a • /J eJ.° I° a I I I I e .a. I I C.11 ROOF DOWNSPOUT AND 6" C.O. d �.:° n ° IE=18.17 �m w . .TC=20.92. os� d ° I . ,..1OLF 6" PVC / u. n I ® 1 2.7% / ° .d �\a Q '.°�. ° O a d 0 b TC=21.97 / a °o. d ITC=21.70 °IE=16490 BC=21.20 --- --- - -10 LF 6" PERFORATED PIPE CONNECTION A d: o T=2�0:83 d ° J LAY PIPE LEVEL AT IE=16.90 TC=20.85 BC=(2d,33). a BC=20.35 ° CQNNE.CT ROM, DRAIN N TO EX SDMH - d J .e tl. TC=21.28 BC=29:JZ8 =20.82 ° o �m C=21.05 ° a 1X. " J°.: J P 6'" pVC .45- E A °s °s 65=(20.32) -12LF 6 PVC :' J d C=20.55 3 a ' ° �' ®2% MIN. a d IE= 6,90 ' I°. e °'. , TC-20.83 °.. ° d d , a 'e PROTECT EX WATER VAULT BC=(20.33).. 20,35 0 I ids $c5'J RAJ. °6"a P C ° d B: a REMOVE EX PSE VAULT AND AND 59J EL J � °. , � REPLACE W/ NEW 575 d #-LA. d /'A., ? LID SHALL BE TRAFFIC RATED e A .J° mz. j ° .. ' q° Al <d ";a a •' a ° ?O ?O) d/ .. / E r dam' / c N17LF 6" PVC 2° C :N ®I.J.0.34 TC=20.79 O 2� MIN- � J °' !y I / a / J , BC=(20.29) CONNECT TO EX MH p °. a ° IE=16.31 I 4 ,�`57- I / I o f 2O EX TYP. 2 CB RIM=20.18 \ IE- 88 (30" CONC., N) 12. (30" CONC., S) i k X )9 2 ry°' ti0 k0 O 70 o� 98, 9EX TYP. 1 CB 's rye �(9 I RIM=19.00 '00 I IE=18.30 (4" DI, W) �R z 10 5 0 10 20 "? 20 ,o,• S°cly % °-_JSCALE IN FEET 0 "=10' N F g p 02 V A'po CIS �' ORN BUSH, ROED & HITCHINGS, INC. LAND SURVEYORS & CIVIL ENGINEERS 2009 MINOR AVE. EAST SEATTLE, Washington 98102-3513 (206) 323-4144 1-800-935-0508 FAX# (206) 323-71 35 mI REVISION 310; I� 11 MONOWFv iiR*�4 FILTER FABRIC O -'- 6" OR 8" PERFORATED PVC 2.00' 142" TO Y4" WASHED ROCK MIN PERFORATED PIPE CONNECTION N.T.S. a FRAME & COVER PER STD PLAN NO 280 GRADE 2'-6" X V-0" CONC PAD 12"DIA DIP, 12" LONG o FIBER JOINT PACKING �6"MINERAL AGGREGATE TYPE 2 NOTE: USE LOCKING CLEAN -OUT IN ROW. DRILL AND TAP, APPLY ANTI -SEIZE COATING AND BOLT DOWN WITH %"S.S. ALLEN-HEAD BOLTS -2 PLACES. NOTE TO CONTRACTOR: -1/8 BEND BRASS TOPPED PVC CLEANOUTS MAY BE PERMITTED IN LIEU OF CAST IRON IN NON TRAFFIC AREAS. CONTRACTOR TO CONFIRM PRODUCT AND LOCATIONS WITH ENGINEER. i PLUG SHALL BE SEALED I' IN SAME MANNER AS MAIN SEWER JOINTS CLEAN OUT N.T.S. AMENDED SOIL QUALITY NOTES: NEW LANDSCAPED AREAS SHALL HAVE AMENDED SOILS DEMONSTRATING THE FOLLOWING: 1. A TOPSOIL LAYER WITH A MINIMUM ORGANIC MATTER CONTENT OF 10% DRY WEIGHT IN BEDS, AND 5% ORGANIC MATTER CONTENT IN TURF AREAS, AND A pH FROM 6.0 TO 8.0 OR MATCHING THE pH OF THE UNDISTURBED SOIL. THE TOPSOIL LAYER SHALL HAVE A MINIMUM DEPTH OF EIGHT INCHES EXCEPT WHERE TREE ROOTS LIMIT THE DEPTH OF INCORPORATION OF AMENDMENTS NEEDED TO MEET THE CRITERIA. SUBSOILS BELOW THE TOPSOIL LAYER SHOULD BE SCARIFIED AT LEAST 4 INCHES WITH SOME INCORPORATION OF THE UPPER MATERIAL TO AVOID STRATIFIED LAYERS, WHERE FEASIBLE. 2. MULCH PLANTING BEDS WITH 2 INCHES OF ORGANIC MATERIAL. 3. USE COMPOST AND OTHER MATERIALS THAT MEET THESE ORGANIC CONTENT REQUIREMENTS: a. THE ORGANIC CONTENT FOR "PRE -APPROVED" AMENDMENT RATES CAN BE MET ONLY USING COMPOST MEETING THE COMPOST SPECIFICATION FOR BIORETENTION (REFER TO SECTION C.2.6) WITH THE EXCEPTION THAT THE COMPOST MAY HAVE UP TO 35% BIOSOLIDS OR MANURE. THE COMPOST MUST ALSO HAVE AN ORGANIC MATTER CONTENT OF 40% TO 65%, AND A CARBON TO NITROGEN RATIO BELOW 25:1. THE CARBON TO NITROGEN RATIO MAY BE AS HIGH AS 35:1 FOR PLANTINGS COMPOSED ENTIRELY OF PLANTS NATIVE TO THE PUGET SOUND LOWLANDS REGION. b. CALCULATED AMENDMENT RATES MAY BE MET THROUGH USE OF COMPOSTED MATERIAL MEETING "A)" ABOVE; OR OTHER ORGANIC MATERIALS AMENDED TO MEET THE CARBON TO NITROGEN RATIO REQUIREMENTS, AND NOT EXCEEDING THE LIMITS IDENTIFIED IN TABLE 220-B, TESTING PARAMETERS, IN WAC 173-350-220. 4. THE RESULTING SOIL SHOULD BE CONDUCIVE TO THE TYPE OF VEGETATION TO BE ESTABLISHED. NOTES: 1. PROPOSED LANDSCAPING SHALL HAVE AMENDED SOIL PER SECTION C.2.13 OF THE RENTON SWDM. SEE LANDSCAPE PLANS FOR DETAILS. SURVEYED: JMH DESIGNED: ZJE DRAWN: ZJE CHECKED: TFD BY DATE AP P R APPROVED: TFD SCALE: AS SHOWN ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVE) 1988 HORIZONTAL: NAD 1983/1991 DATU M CITY OF RENTON Planning/Building/Public Works Dept. AS -BUILT CERTIFICATION: I HEREBY CERTIFY THAT THE HORIZONTAL AND VERTICAL LOCATION OF THE STORM DRAINAGE STRUCTURES AND THE HORIZONTAL LOCATION OF THE WATER SURFACE FEATURES SHOWN HEREON AND SHOWN IN BOLD IS THE RESULT OF A FIELD SU PERFORMED BY ME OR UNDER MY RECTION. TEE) DIMOF, P.E,iI 0. 324 12/6/18 DATE THE ENGINEER OF RECORD CERTIFYING THESE RECORD DRAWINGS HAS NOT WITNESSED ALL ELEMENT OF CONSTRUCTION AND IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN DATA PROVIDED BY THE CONTRACTOR OR THE SURVEYOR OF RECORD. IN COMPLIANCE WITH CITY OF RENTON STANDARDS GRADING AND DRAINAGE PLAN US BANK EXPANSION 2500 EAST VALLEY ROAD RENTON, WASHINGTON 98057 STRADA DA VALLE DATE: 12/6/2018 FIELDBOOK: PAGE: SHEEP: C 7 OF. 1 1 R-396707 C'M I 0 Lu W l I I CUU I C CC C1 � I I � I 69 9 I I .7 2.5' R I 9 9 I I FEMOVE EX FH I PROPOSED 15' WATER EMENT I I I I.E.=15.68 I I I Ecc TURN TO CITY I I I I 6 CC I ; ,—____—__ ___--_--__-----____-I--_-�- o-------------------- ------ --- --------------I- - }I I I I/ w ' a I I I %/ cn c \\ S .0, 4.1' R I.E.=15.68 /' I -=�---- = -- -- 2'-`90 --- �- Ste. 2+14.7, 4.1 R �-------- N STA. 9.6, 4.8 R 3.00' N64LF 10 D.I.P. 0+I00 I I II 1+00 \-----------------------�\ ,O3 2+49 1 I _ i - \\ I � � -�--- -- — ------ ---- -- I I I A CAP EX 10"x6" TEE AND INSTALL �I ' ' I E.=15.47 4, 2.5 R " I I I _ 1 N6" END CAP, MJ ABANDON N104LF EX 10 D.I.P 1,-6" E BLOCK I \ EXISTING 15' WATER EASEMENT I I °� 0,4.8'R 8.7,4.7'R \ I 1 I I ------------------ TTZF I I� -PROPOSED1 I RE -LOCATE EX PIS/ T SOUTH _ �- ° I WEST END OF VAUILTI --- BUILDING 1I I ADDITION \ NEW LOCATION 0 E*I PIV I I II 1 — — I 10 _ _5— — 0 I 10 20 I — — — — — — — _ rn ° SCALE IN FLET I I I I I 1"=10' I I N — ° I C I ° �� ' I ° PROTECT X ETER ULT ' 1 1 cn I I I I r I I / _j 7.77' II I I I� - I � INTALL TEM ORARY 10 A (MJ) AN TEMPOR RY 2" BL FF SEMPLY W TEMPORA RUST CKIN INSTALL POLY PIG STATION TESTING DETAIL CONNECTION DETAIL SCALE: 1" = 10'-0" �g,Hi ORq��yc� SEAL z m 1969 �gSFI I NG�� g P eL� 1$ ORN �I6� _j 11 Ili — F,— — — — I I1�1 IL REMOVE POLY IG STATION AND INSTALL ^' " 0 - I K_ - 1-1 " SLEEVE 1 II II FINAL DETAIL BUSH, ROED & HITCHINGS, INC. LAND SURVEYORS & CIVIL ENGINEERS 2009 MINOR AVE. EAST SEATTLE, Washington 98102-3513 (206) 323-4144 1-800-935-0508 FAX# (206) 323-71 35 NO. INSTALL POLY PIG STATION --INSTALJ= T€MPORARY-10" -GAPAND TEMPORARY 2" BLOW -OFF ASSEMPLY W/ TEMPORARY THRUST - BLOCKING - - I I TESTING DETAIL CONNECTION DETAIL SCALE: 1" = 10'-0" REVISION SURVEYED: JMH DESIGNED: ZJE DRAWN: ZJE CHECK TFD BY DATE APPR "0PR0" D: TFD �I I I I \ \ REMOVE POLY PJG-SIATIOLL AND INSTALL \ 2N10" SPOOL 1-10" SLEEVE FINAL DETAIL vv I I SCALE: HORIZON AS SHOWN HORIZONTAL- NAD 1983/1991 ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY CITY OF ' RENTON Planning/Building/Public Works Dept. NOTES: 1. SEE SITE PLAN ON SHEET C4 FOR LOCATIONS OF EX FIRE HYDRANTS ON SITE. 2. ALL WATER MAIN SHALL BE POLYWRAPPED PER CITY OF RENTON STANDARDS AS -BUILT CERTIFICATION: I HEREBY CERTIFY THAT THE HORIZONTAL AND VERTICAL LOCATION OF THE STORM DRAINAGE STRUCTURES AND THE HORIZONTAL LOCATION OF THE WATER SURFACE FEATURES SHOWN HEREON AND SHOWN IN BOLD IS THE RESULT OF A FIELD SU PERFORMED BY ME OR U _D IRECTION. i TED DIMOF, P. NO. �3 024 12/6/18 DATE THE ENGINEER OF RECORD CERTIFYING THESE RECORD DRAWINGS HAS NOT WITNESSED ALL ELEMENT OF CONSTRUCTION AND IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN DATA PROVIDED BY THE CONTRACTOR OR THE SURVEYOR OF RECORD. IN COMPLIANCE WITH CITY OF RENTON STANDARDS WATER PLAN US BANK EXPANSION 2500 EAST VALLEY ROAD RENTON, WASHINGTON 98057 STRADA DA VALLE DATE: 12/6/2018 FIELDBOOK: PAGE: W-396701 R-396708 �y� co 0 I 0 W I - w Q Z WATER PLAN GENERAL NOTES Standard Plan No. 300 1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON PUBLIC WORKS STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS AND WSDOT / APWA STANDARD SPECIFICATIONS, LATEST EDITION AS AMENDED BY THE CITY OF RENTON. A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR AND OR DEVELOPER SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION. 2. ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL CALL 1-800-424-5555 TO VERIFY UTILITY LOCATIONS BEFORE BEGINNING EXCAVATION. 3. ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER SYSTEM IMPROVEMENTS SHALL BE NEW AND UNDAMAGED, AND "CATALOG CUTS" FOR ALL MATERIALS SHALL BE APPROVED IN WRITING BY THE CITY OF RENTON PRIOR TO BRINGING ANY MATERIALS ON -SITE. 4. ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C 151 AND C 104. PIPE JOINTS SHALL BE PUSH -ON OR MECHANICAL JOINT. CAST IRON OR DUCTILE IRON PIPE FITTINGS SHALL BE CLASS 250 AS PER ANSI/AWWA C110/A21.10-82. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 8-MIL BLACK, TUBE -TYPE, POLYETHYLENE PLASTIC PER AWWA C105 STANDARDS. 5. MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 36 INCHES FOR PIPE DIAMETER OF 10-INCH OR LESS AND 48 INCHES FOR PIPE DIAMETER OF 12-INCH AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHALL BE 60 INCHES. ANY DEVIATIONS MUST BE APPROVED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. WHERE UTILITY CONFLICTS OCCUR, THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED AS NECESSARY TO CLEAR CONFLICTS AND TO PROVIDE MINIMUM COVER. PIPE DEFLECTION SHALL NOT EXCEED ONE-HALF OF PIPE MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE USED. ALL TRENCH BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST METHOD (MDD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT MDD IN UNPAVED AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 MDD. 6. CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED AND POURED IN PLACE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS, FITTINGS AND BASE OF HYDRANTS. MEGA -LUGS (OR SIMILAR PRODUCT) MAYBE REQUIRED ON ALL MECHANICAL JOINTS IN ADDITION TO CONCRETE BLOCKING. 7. ALL NEW WATER MAIN PIPES AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM PRIOR TO BEING FLUSHED, DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURITY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR. THE CONTRACTOR SHALL SUPPLY, INSTALL AND REMOVE PLUGS, CORPORATION STOPS, BLOW -OFF ASSEMBLIES, AND THRUST RESTRAINT / BLOCKING FOR TESTING AND PURITY ACCEPTANCE. NO CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET -TAP VALVE TO AN EXISTING MAIN UNTIL THE NEW PIPING HAS BEEN FOAM -PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURITY TESTING. 8. NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL BE TESTED AT A STATIC PRESSURE OF 1SO PSI ABOVE WORKING PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSI PRESSURE DROP DURING THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURE TEST, THE LINE SHALL BE DISINFECTED, FLUSHED, AND THEN WATER SAMPLES SHALL BETAKEN FOR PURITY TESTING BY THE PUBLIC WORKS INSPECTOR. 9. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER UTILITY AND MAINTENANCE DEPARTMENTS AT LEAST 10 WORKING DAYS PRIOR TO MAKING CONNECTIONS TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL EXPOSE THE EXISTING WATER MAIN AND FITTINGS AT THE CONNECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS REQUIRED FOR THE FINAL CONNECTION. THE CONTRACTOR SHALL EXCAVATE, REMOVE ALL SURFACE MATERIALS, AND PROVIDE SHORING AND ALL MATERIALS REQUIRED FOR THE CITY OF RENTON TO PERFORM THE CONNECTION TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL PROVIDE AND INSTALL BACKFILL, CONCRETE BLOCKING, AND COMPLETE SURFACE RESTORATION. 1�Y o STD. PLAN - 300.0 PUBLIC WORKS WATER PLAN GENERAL NOTES �F p� DEPARTMENT M \RCH 2010 471 11-1/4' BEND 22-1/2° REND 45"BEND 0-J CAP TEE 90' BEND THRUST BLOCK BEARING AREA IN SQUARE FEET (SEE NOTES) FOR HORIZONTAL AND DOWNWARD VERTICAL BENDS SOIL FIRM SILT OR FIRM SILTY SAND COMPACT SAND COMPACT SAND &GRAVEL 90 45' BEND 11 1/4° 90' 45' BEND 11 1/4` 9o` 45' BEND 11 1/4' FITTING BEND TEE CAP OR PLUG & 22 1/2` BEND TEE CAP OR PLUG & 22 1/2- BEND TEE CAP OR PLUG & 22 1/2• BEND BEND BEND 4" 7.0 4.2 4.2 1.7 2.9 2.1 2.1 1.0 2.2 1.6 LIS 1.0 6" 13.3 9.4 9.4 3.8 6.7 4.7 4.7 1.9 5.0 3.5 3.5 1.4 8" 23.3 16.7 16.7 6.7 11.7 8.4 8.4 3.4 8.8 6.3 6.3 2.5 12" 53.0 37.5 37.5 15.0 26.5 18.8 18.8 7.5 20.0 14.0 14.0 5.6 AREAS CALCULATED ON 300 PSI TEST PRESSURE. 3'-0" MIN. COVER FOR WATERMAIN LESS THAN 12". 4'-0" MIN. .COVER .FOR WATERMAIN 12" OR .GREATER. MAX. HEIGHT OF THRUST BLOCK (FT) = 0.5 x DEPTH OF TRENCH MIN. HEIGHT OF THRUST BLOCK (FT) = O.D. PIPE + 1.0' iRUST BLOCK BE 2EA REFERS TO ..ICE OF BLOCK M IN SQUARE FEET NOTES: 1. LOCATION AND SIZE OF BLOCKING FOR PIPE LARGER THAN 12"DIAMETER AND FOR SOIL TYPES DIFFERENT THAN SHOWN SHALL BE DETERMINED BY THE ENGINEER. 2. ALL BLOCKING SHALL BE POURED IN PLACE AGAINST UNDISTURBED NATIVE GROUND. 3. ALL POURED THRUST BLOCKS SHALL BE BACKFILLED AFTER MIN. 1 DAY. PRESSURE TESTING SHALL OCCUR AFTER CONCRETE HAS REACHED NOMINAL COMPRESSIVE STRENGTH. 4. ALL BLOCKING SHALL BE CONCRETE CL 5 (1-1/2"). 5. BLOCKING AGAINST FITTINGS SHALL BEAR AGAINST THE GREATEST FITTING SURFACE AREA POSSIBLE, BUT SHALL NOT COVER OR ENCLOSE BELL ENDS, JOINT BOLTS OR GLANDS REASONABLE ACCESS TO BOLTS AND GLANDS SHALL BE PROVIDED. ° PUBLIC WORKS CONCRETE BLOCKING FOR STD. PLAN - 33b:2 a HORIZONTAL AND DOWNWARD DEPARTMENT VERTICAL BENDS MARCH 2O10 St H' rc'yi 0R,9� SEAL co 1969 kgSH I NGI F " g p A02 V 'po CIS AL�'� 11 U ORN TESTING DETAIL f 10 FT II _I.XIS,TING WATER, _LINE EXISTING TEE, DEAD END LINE, CAP OR PLUG DO NOT DISTURB BLOCKING NEW WATER LINE 0 f7 2 VERTICAL CROSS (MJxFL) FOR POLYPIGGING 1-BLIND FLANGE ON TOP WITH 2"TAP & 2"PLUG 1-BLIND FLANGE ON BOTTOM 1-PLUG(MJ) W/2"TAP & 2" BLOW -OFF TEMP. BLOCK FINAL CONNECTION DETAIL NEW WATER LINE EXIST. WATER LINE AFTER ALL TESTING, CLEANING BY POLYPIG AND DISINFECTION, REMOVE TEMP. BLOCK & BLOW -OFF & CONNECT TO EXISTING WATER LINE WITH SLEEVE (MJ) AND D.I. SPOOLS FINAL CONNECTION BY ,CITY FORCES `TY o + PUBLIC WORKS CONNECTION TO WATER MAIN STD. PLAN - 300.5 DEPARTMENT EXISTING TEE OR END LINE CAP MARCH 2O10 WATER MAIN 2" CLOSE NIPPLE 2" 90' ELBOW TWO PIECE CAST IRON VALVE BOX EQUAL TO RICH VALVE CO. STANDARD 8" TOP SECTION, WITH REGULAR BASE SECTION LENGTH TO FIT. CONCRETE DEAD MAN BLOCKING WITH SHACKLE RODS TO CAP, BLOCK SHALL BE POURED AGAINST UNDISTURBED EARTH, SIZE OF BLOCK TO BE DETERMINED BASED ON TEST PRESSURE OF WATER LINE AND SOIL CHARACTERISTICS. CAST IRON CAP OR PLUG WITH f2" IFS TAP SHALL BE A ROCKWELL 482 END CAP COUPLING. 2" GALVANIZED IRON PIPE AS REQUIRED. 2" GALVANIZED IRON PIPE, 12" LONG. 2" GALVANIZED IRON PIPE 12" LONG PUBLIC WORKS DEPARTMENT PLAN VALVE NUT EXTENSION IF REQUIRED (SEE DWG BR46 / PAGE B090) INSTALL 2" 90` ELBOW, SCREWED T 2" PLUG, SCREWED 18" 2" GALVANIZED IRON PIPE AS REQUIRED. 2" RESILIENT GATE VALVE, SCREWED INSTALL 2" 90' ELBOW, f SCREWED 2" GALVANIZED IRON PIPE AS REQUIRED. ELEVATION 2" BLOW -OFF STD. PLAN - 340.2 TEMPORARY ASSEMBLY MARCH 2O10 BUSH, ROED & HITCHINGS, INC. LAND SURVEYORS & CIVIL ENGINEERS 2009 MINOR AVE. EAST SEATTLE, Washington 98102-3513 (206) 323-4144 1-800-935-0508 FAX# (206) 323-71 35 era REVISION FIRE HYDRANT SHALL BE COREY-TYPE EQUAL TO IOWA F-5110 OR COMPRESSION TYPE SUCH AS CLOW MEDALLION; M & H 929, MUELLER SUPER CENTURION 200, AND WATEROUS PACER WITH 6" MECHANICAL JOINT INLET WITH LUGS. 5-1/4" MAIN VALVE OPENING. TWO 2-112" HOSE CONNECTIONS NATIONAL STANDARD THREADS, 4" PUMPER CONNECTION CITY OF SEATTLE THREADS WITH A STORZ ADAPTOR, 4.875" SEATTLE THREAD X 5" STORZ, ATTACHED WITH 1/8" STAINLESS STEEL CABLE. 1-1/4" PENTAGON OPERATING NOT. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF PAINT. KELLY-MOORE/PRESERVATIVE PAINT No. 5780-563 DTM ACRYLIC GLOSS, SAFETY YELLOW OR APPROVED EQUAL. PUMPER CONNECTION TO FACE ROADWAY OR AS DIRECTED BY RENTON FIRE DEPARTMENT. FIRE HYDRANT EXTENSION TO BE USED IF REQUIRED. MIN. 18" TO 20" BEHIND BACK OF CURB OR 12" BEHIND BACK OF 3' SIDEWALK THAT IS ADJACENT TO CURB 4.875" x 5" STORZ TWO-PIECE CAST IRON VALVE BOX WITH LUG 5'x5'x6" THICK CONCRETE PAD AROUND TYPE COVER. EQUAL TO OLYMPIC FOUNDRY CO. HYDRANT. FINISH TO MATCH SIDEWALK. STANDARD 8" TOP SECTION WITH REGULAR BASE �e EXPANSION JOINT AT SECTION LENGTH TO FIT. VALVE NUT EXTENSION BACK OF SIDEWALK AS REQUIRED. 2„� CONCRETE SIDEWALK RAISED PAVEMENT MARKER TYPE 88-A /�OR PLANTING STRIP STIMSONITE TWO-WAY BLUE REFLECTIVE 36 MIN COVER CONCRETE BLOCKING " CONCRETE THRUST BLOCK MAIN LINE TEE. WITH &" FLANGE SIDE OUTLET. 6" GATE VALVE (FL X MJ) AWWA C-509, RESILIENT SEAT 6" DUCTILE IRON PIPE, CLASS 52 CEMENT LINED, LENGTH TO FIT 2-3/4" COR-TEN STEEL TIE RODS. 16" x 8" x 4" MININUM 1/2 YARD OF 1-1/4" WASHED DRAIN ROCK CONCRETE BEARING 1' ABOVE BOOT FLANGE. PLACE 8 MIL BLOCK UNDER HYDRANT POLYETHYLENE FILM AROUND TOP AND SIDES OF GRAVEL. EIIRE HYDRANT ASSEMBLY �{ y� LEVEL ALL GROUND' LEVEL ALL GROUND MIN 3' RADIUS ,MIN .3' RADIUS ONE MAN ROCK 1 6" CONCRETE PAD �6" CONCRETE PAD CUT FILL HYDRANT LOCATION IN CUT OR FILL .•,,� PUBLIC WORKS FIRE HYDRANT ASSEMBLY STD. PLAN - 310.1 DEPARTMENTS NORM z01 G THE BY-PASS ASSEMBLY SHALL BE INCLUDED AS PART OF THE DETECTOR DOUBLE CHECK VALVE ASSEMBLY. 5/8" x 3/4" METER SHALL BE SENSUS SRII WITH TOUCHREAD PITUD (TR/PQ ICE REGISTER. (METER OWNED BY CITY) PRECAST CONCRETE VAULT WITH 2 - 3'x 3' HINGED STEEL PLATE COVERS. DIMENSIONS 5'-D" x 9'-0" z T-2" UTILITY VAULT CO. 4484-LA OR EQUAL CITY PIPING PRIVATE PIPING z 4" FL. z P.E. D.I. PIPE W7 TFi COLLAR 18" FROM P.E. 3'-4" LONG TEE (MJ z FL) GATE VALVE (FL x MS) 5' TO CITY MAIN 12" ALL AROUND - TOUCH READ PIT LID SENSOR MOUNTED ON STEEL PLATE COVER THROUGH 2" DIA.. DRILLED. HOLE IN. COVER. 4" PIPE FL.x FL 2'-0" LONG 1 I���!���, • �►yll �� Q►111��1��;11� III►�►plus JCONCRETE BLOCKING -� MAN ALL DETECTOR DOUBLE CHECK VALVE ASSEMBLIES SHALL INCLUDE RESILIENT SEATED SHUTOFF VALVES AND TESTDOUBLE CHECKT'VALVE ASSEMBLY INCLUDES COCKS. AND APPROVED CROSS -CONNECTION CONTROL_ TWO RESILIENT SEATED SHUTOFF VALVES. ASSEMBLIES PER DEPARTMENT OF HEALTH LATEST 4"" FLANGED COUPLING APPROVED LIST. ADAPTER EGUAL TO ROMAC. TOUCH READ PIT LID SENSOR M ON STEEL PLATE COVER THROUI DIA. DRILLED HOLE IN COVER. 6" MIN. DRAIN TO DAYLIGHT OR STORM DRAIN SYSTEM WITH CATCH BASIN OR MA 2 X 2Y2- FIRE DEPARTMENT SIAMESE. CONNECTION FOR STANDPIPE WITH BREAKABLE CAST IRON HOSE CAPS, 4" SWING TYPE GRAVITY OPERATED CHECK VALVE, FL. EQUAL TO MUELLER CO. A-2600-6 WITH ALL DRIP VALVE AT BOTTOM INSTALL EPDXY NON -SHRINK GROUT (TYP.) PIPE, ,FL. - FL S." LONG /-4" SHORT RADIUS 90' BEND FL. TO BUILDING -� DEADMAN BLOCK REQUIRED. 4"x4"x4" TEE FL. 4" GATE VALVE MJ X FL WTH INDICATOR POST INDICATOR POST VALVE SAME SIZE AS+ DOUBLE CHECK VALVE (MUELLER CO. OR EQUAL). PAINTED RED, 4" DUCTILE IRON CLASS 52 PIPE, CEMENT LINED, LENGTH TO FIT 4" 90' BEND FL. EL LADDER CADJUSTABLE STEEL PIPE COMPACTED FOUNDATION SUPPORT, STANCHIONS BOLTED GRAVEL p7: TO FLOOR 1. LOCATE VAULT IN PLANTING AREA NOT IN PAVING. END VIEW 2. 4" AND LARGER BENDS AND TEES TO BE CAST IRON CEMENT LINED. 3. TEMPORARY SUPPORT SHALL BE PROVIDED UNDER VALVES AT THE TIME OF INSTALLATION TO CENTER THE PIPE IN VAULT OPENING. AFTER COMPLETE INSTALLATION REMOVE THE TEMPORARY SUPPORT AND INSTALL ADJUSTABLE PIPE SUPPORT. 4. GALVANIZED LADDER FOR ACCESS. 5, AFTER FIELD INSTALLATION, MAIN DDCVA AND BY-PASS DCVA MUST BE TESTED SATISFACTORILY BY A DEPT. OF HEALTH CERTIFIED BACKFLOW ASSEMBLY TESTER. TEST REPORT TO BE SUBMITTED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT. PRIOR TO ACTIVATION OF NEW LINE. 6, INSTALL BRASS Y4" FLARE TEST COCKS WITH Y4" FLARE CAPS. •j� PUBLIC WORKS 4" DDCV ASSEMBLY WITH STANDPIPE STD. PLAN - 380.11 DEPARTMENT OUTSIDE CONNECTION MARCH 2O10 SURVEYED: JMH DESIGNED: ZJE DRAWN: ZJE CHECKED: TFD BY DATE AP P R APPROVED: TFD SCALE: AS SHOWN ONE INCH AT FULL -- IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAND 1988 HORIZONTAL• NAD 1983/1991 DATUM A A PLAN VIEW LAWATER VALVE BOX LID WITH EARS IN DIRECTION OF 2" SQUARE WATER MAIN AND WORD OPERATING NUT 12" MIN. "WATER" CAST INTO IT 18' MAX: 1'-4" CONCRETE COLLAR FOR VALVES IN PAVED AREAS 4-1/4" DIA. 1/8' MIN. THICKNESS SEE DETAIL 2 PIECE CAST IRON VALVE BOX, RICH-SEATTLE TYPE OR OLYMPIC FOUNDRY 1" STEEL LENGTH AS REQUIRED 1/8" MIN. THICKNESS 2-1/4" INSIDE MEASUREMENT 2-1/4" DEPTH SECTION A -A VALVE OPERATING NUS EXTENSION VALVE OPERATION NUT EXTENSION NOTE: EXTENSIONS ARE REQUIRED WHEN VALVE NUT IS MORE THAN THREE (3) FEET BELOW FINISHED GRADE. EXTENSIONS ARE TO BE A MINIMUM OF ONE (1) FOOT LONG. ONLY ONE EXTENSION TO BE USED PER VALVE. NOTE: ALL EXTENSIONS ARE TO BE MADE OF STEEL, SIZED AS NOTED, AND PAINTED WITH TWO COATS OF METAL PAINT. VALVE MARKER NOTES: VALVE MARKERS SHALL BE EQUAL TO CARSONITE UTILITY MARKER VALVE MARKER POST TO BE USED FOR ALL MAIN LINE VALVES OUTSIDE PAVED AREAS �3 ? T- 38" 6" (IF,ll '24" VALVE MARKER POST - • PUBLIC WORKS VALVE BOX, MARKER & OPERATINSTD. PLAN 330.1G, ' `•` -` DEPARTMENT NUT EXTENSION %i Ao I110 CITY OF RENTON Planning/Building/Public Works Dept. AS -BUILT CERTIFICATION: I HEREBY CERTIFY THAT THE HORIZONTAL AND VERTICAL LOCATION OF THE STORM DRAINAGE STRUCTURES AND THE HORIZONTAL LOCATION OF THE WATER SURFACE FEATURES SHOWN HEREON AND SHOWN IN BOLD IS THE RESULT OF A FIELD SU PERFORMED BY ME OR UNDENDE�IRECTION. TED DIMOF, P. 0. 024 12/6/18 DATE THE ENGINEER OF RECORD CERTIFYING THESE RECORD DRAWINGS HAS NOT WITNESSED ALL ELEMENT OF CONSTRUCTION AND IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN DATA PROVIDED BY THE CONTRACTOR OR THE SURVEYOR OF RECORD. IN COMPLIANCE WITH CITY OF RENTON STANDARDS RENTON STANDARD WATER DETAILS US BANK EXPANSION 2500 EAST VALLEY ROAD RENTON, WASHINGTON 98057 STRADA DA VALLE W-396702 DATE: 12/6/2018 FIELDBOOK: PAGE: SHEEP: ^ n OF.1 1 R-396709 LANDSCAPE PLANTING PLAN LEGEND 15" ABH TO REMAIN 17" ABH TO REMAIN 14 1 /2" ABH TO REMAIN 7" ABH TO REMAIN 0 OF SR 167 3 W N og• a 5 I LIMIT OF PROJECT................ X. EL 20--------�_- ---------- - - ------------------ _ - -- --- -W I - I - - 15" ABH- TO REMAIN_ I--- W - _ __ - - LIMIT OF - - - - PROJECT ' I I � I I I I � I I I TRANS. EX S@0 NO( EX. LIGHT PROTECT FROM DAMAGE EX. LANDSCAPE TO REMAIN F 77 7// 7 �7/ /7 OR 54" ACER RUBRUM 'RED SUNSET' RED SUNSET MAPLE SEE PLAN NOTES FOR DIAMETER ABH ® 54" 2 EXISTING TREES TO REMAIN 2 EXISTING TREES TO BE REMOVED 1. CO-ORDINATE PROJECT WITH GENERAL CONTRACTOR AND ALL OTHER TRADES. 2. VERIFY LOCATION OF ALL UTILITIES ON CIVIL DRAWINGS AND WITH GENERAL CONTRACTOR. CALL BEFORE YOU DIG (811 OR 1-800-424-5555) PRIOR TO PROJECT START TO VERIFY ALL UTILITY LOCATIONS. 3. NO PLANT MATERIAL SUBSTITUTIONS OR ADDITIONAL WORK WILL BE COMPLETED WITHOUT PRIOR WRITTEN APPROVAL OF THE OWNER OR HIS REPRESENTATIVE AND THE LANDSCAPE ARCHITECT IN THE FORM OF A CHANGE ORDER. 4. LANDSCAPE CONTRACTOR TO HAVE PRE -CONSTRUCTION MEETING WITH GENERAL CONTRACTOR AND LANDSCAPE ARCHITECT PRIOR TO PROJECT START. 5. LANDSCAPE CONTRACTOR TO DEMO EXISTING IRRIGATION SYSTEM AND CAP/PROTECT EXISTING IRRIGATION LINES WHICH WILL BE RECONNECTED TO RESTORED/NEW IRRIGATION SYSTEM. 6. LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR WATERING ALL EXISTING PLANT MATERIAL ADJACENT TO AND IN THE AREA OF THE 2500 BUILDING WHICH WILL HAVE THE WATER SOURCE ELIMINATED DUE TO PROJECT CONSTRUCTION. 7. ALL DEODAR CEDARS SHALL BE PRUNED PRIOR TO ANY DEMOLITION UNDER THE DIRECTION OF THE ARBORIST TO A HEIGHT WHICH ALLOWS FREE PASSAGE OF VEHICLES/EQUIPMENT UNDER TREES. 8. PROTECT ALL TREES REQUIRED TO BE RETAINED BY COMPLYING WITH THE TREE PROTECTION MEASURES DURING CONSTRUCTION PER THE CITY OF RENTON (RMC 4-4-130H.9). THIS INCLUDES EX. I BUT IS NOT LIMITED TO: A. DEFINING AND PROTECTING THE DRIP LINE. EX. LIGHT EXISTING B. ERECTING AND MAINTAINING A TEMPORARY SIX -FOOT -HIGH CHAIN LINK CONSTRUCTION FENCE WITH I TO BE REMOVED II I� / BUILDING PLACARDS AROUND THE TREE TO BE RETAINED INDICATING THE WORDS "NO TRESPASSING - PROTECTED TREE" ON EACH SIDE OF THE FENCE. ELEV. 21.67' C. PROTECTING THE TREE FROM GRADE CHANGES. SIDEWALK I IRRIGATION NOTES: SI - - SI BE REMOVED I 1. LANDSCAPE CONTRACTOR SHALL FOLLOW ALL REQUIREMENTS PER CITY OF RENTON ORDINANCE I I NO. 5528 "1 IRRIGATION REQUIREMENTS" AND STANDARD DETAILS AS APPLICABLE. 2. A PRE -CONSTRUCTION MEETING WILL BE HELD WITH THE GENERAL CONTRACTOR, LANDSCAPE ARCHITECT AND LANDSCAPE CONTRACTOR PRIOR TO PROJECT START. I I 3. THE DEMOLITION/CAPPING OF THE EXISTING IRRIGATION SYSTEM AND TRANSPLANTING OF PLANT EXISTING RAISED I MATERIAL SHALL BE COMPLETED PRIOR TO ANY OTHER PROJECT DEMOLITION BY THE GENERAL PLANTER TO REMAINI I CONTRACTOR. 4. VERIFY LOCATION OF EXISTING IRRIGATION WATER METER, DOUBLE CHECK ASSEMBLY AND WATER PRESSURE. I5. INSTALLER TO USE CARE WHEN TRENCHING TO PROTECT ALL EXISTING UTILITIES FROM DAMAGE. CALL LINE LOCATORS PRIOR TO ANY EXCAVATION AT 1-800-424-555 OR 811. - - - - - - - / 6. THE LANDSCAPE CONTRACTOR WILL BE RESPONSIBLE FOR DESIGNER -BUILD DEMOLITION AND RESTORATION OF THE NEW AND EXISTING IRRIGATION SYSTEM. THE INPUT FOR THIS WORK WILL INCLUDE INCORPORATING INFORMATION FROM THE IRRIGATION PLAN, PRE -CONSTRUCTION CONFERENCE, GENERAL IRRIGATION INDUSTRY STANDARDS AND LANDSCAPE CONTRACTOR VERIFICATION OF ALL SITE CONDITIONS. 7. CONTRACT DOCUMENTS WHICH DESCRIBE THE EXISTING PROJECT SITE AND CONSTRUCTION ARE BASED UPON FIELD INSPECTIONS BUT ARE NOT BASED UPON EXTENSIVE SITE SURVEYS OR IRRIGATION VALVES EXCAVATION OF CONCEALED CONDITIONS AND BURIED ITEMS. THIS DRAWING AND ALL THE & MAINLINE �� SUPPORTING INFORMATION ARE INTENDED AS A GUIDE FOR THE INSTALLER, WHO SHALL VERIFY ALL ACTUAL SITE CONDITIONS AND BRING TO THE LANDSCAPE ARCHITECT OR OWNER'S ATTENTION PROBLEMS OR ANY DIVERSE SITE CONDITIONS. J LIMIT OF 8. PROVIDE 18" MINIMUM COVER FOR THE MAINLINE AND WIRING AND A MINIMUM OF 12" FOR ALL I - PROJECT LATERAL PIPING. USE ROCK FREE MATERIALS TO BED PIPING AND SPRIKLER HEADS. 9. BACKFILL ALL TRENCHES WITH "ROCK FREE" MATERIALS AND COMPACT TO 85% DENSITY. I EX. SIDEWALK- 10. THE INSTALLER SHALL BE RESPONSIBLE FOR MAINTAINING ACCURATE RECORDS OF THE - _ = INSTALLATION, FOR THE CREATION OF THE EXACT AS -BUILT DRAWING OF THE INSTALLED SYSTEM. T T ®® 11. INSTALL (VERIFY IF EXISTING) A NEW RAIN SENSOR NEAR THE ROOF GUTTER, FREE FROM ALL OVERHANGS. PROVIDE A BY-PASS SWITCH ON THE SIDE OF THE CABINET. J ® 12. INSTALL ALL SPRAY HEAD SPRINKLERS USING A FLEXIBLE STYLE SWING JOINT, %" FUNNY PIPE I WITH AN EXTRA MARLEX STREET 90 ELL AT EACH END OF THE SWING JOINT. FOR THE ROTARY SPRINKLERS USE 3%" TRIPLE MARLEX STREET 90 ELLS AND ONE 3%" X 8" SCH-80 PVC NIPPLE. 13. PROVIDE A 24" EXPANSION LOOP FOR ALL WIRES AT EACH CONTROL VALVE. SPLICE WIRES �( O J ® INSIDE VALVE BOX ONLY, USING 3M-DBY WIRE SPLICE KITS. DO NOT SPLICE THE SIGNAL WIRE ----- BETWEEN THE VALUE AND CONTROLLER. 14. FROM CONTROLLER DRAW TWO SPARE YELLOW WIRES TO FUTURE EXPANSION BOX IF REQUIRED. �-------------- -- W---------- - NOTE, ALL VALVE BOXES TO HAVE THE SPARE YELLOW WIRES VISIBLE INSIDE. FH - - - - - - - - T - 15. ADJUST ALL SPRIKNLER HEADS TO MAXIMIZE COVERAGE AND MINIMIZE THE OVERSPRAY ON - - 7 = I WALKWAYS AND BUILDINGS. 77 7-7 + _ _ _ _ _ _ _ 16. THE EXISTING IRRIGATION SYSTEM FOR THE 2500 BUILDING WILL BE IMPACTED BY THE --U - - W - - - CONSTRUCTION OF THE NEW ADDITION. THE MAINLINE WHICH SUPPLIES THE ZONES FOR MOST LIMIT OF OF THE PLANTING ADJACENT TO THE BUILDING ON ALL SIDES AND THE WEST PERIMETER LIMIT OF PROJECT PLANTING WILL NO LONGER WORK UNTIL RECONNECTED. PROJECT_ 6y „ ABH 10Y" ABH 17. THE LANDSCAPE CONTRACTOR WILL BE RESPONSIBLE FOR MAINTAINING ALL OF THE EXISTING --- --- - REMOVE L - - -RE-WV-E - - J PLANT MATERIAL WHEREVER WATERING IS IMPACTED BY ADDITIONAL WATERING TO KEEP THE -- --- M.H. - - -------- T D PLANT MATERIAL IN OPTIMUM CONDITION AND AS EXISTING PRIOR TO PROJECT START. EX IN 18 EC•\20' PLANTMATERIALDEMISEEACDUOE TO SHALL BE O F RESPONSIBLE FOR AS DETERMINED MBYTTHE KINDOF Y CAPE - - ARCHITECT. TREE R E TE N TI 0 N 1 LANT HK 8/16/17 LAND CLEARING TREE I N VE N TOR Yj P LAN 2 LANDSCAPEENIOTESOREVISED REMAIN&TRANSPLANTED REVISED HK 8/16/17 SCALE: I "= 10'-0" oak 3 ADD IRRIGATION PLAN & NOTES HK 8/16/17 0w1ft K 5 0 5 10 15 20 25 30 BB/LS o 4H RU/HK z Scale Feet NO. REVISION BY DATE APPIR K I I I I I I �I I I I I TO REMAIN O_LO_TRANSPLANT 7 RHODODENDRON X 'DAPHINOIDES' PRUNUS LAUROCERASUS 'OTTO LUYKEN' DAPHINOIDES RHODODENDRON OTTO LUYKEN LAUREL SPECIMEN 5-6' H EXISTING HEDGE 24" HEIGHT t 5 TO BE TRANSPLANTED PER SHEET L1.1 TO BE REMOVED 2 EXISTING TO REMAIN 3 JUNIPERUS CHINENSIS 'TORULOSA' HOLLYWOOD JUNIF'LK SPECIMEN 8-9' TRANSPLANT AS SHOWN ON SHEET L1.1 1 PINUS MUGHO MUGHUS MUGHO PINE 4' MULTI -STEM TO BE REMOVED JUNIPERUS CHINENSIS 'OLD GOLD' OLD GOLD JUNIPER 24-30" TO BE REMOVED ILEX CRENATA CONVEXA ' JAPANESE HOLLY I EXISTING HEDGE 30" HEIGHT f I TO BE REMOVED EXISTING OTTO LUYKEN HEDGE TO REMAIN 2 PINUS MUGHO MUGHUS MUGHO PINE 3'x3' TO BE REMOVED UNKNOWN VARIETY 3'x2' TO BE REMOVED EX. SLEEVE_ &___ MAINLINE -CROSSING - AREA #5 DRIVEWAY TO REMAIN 111111 LIMIT OF 4 PROJECT AREA I, I TRANS. I V#4 EX. SLEEVE TO REMAIN CUT, CAP & / PROTECT EX LATERAL LINES D. KEEPING THE AREA CLEAR OF IMPERVIOUS SURFACE MATERIAL. I _ FOR FUTURE E. RESTRICTING GRADING WITHIN THE DRIP LINE. I ZONE RESTORATION F. PROVIDING 3" OF BARK MULCH WITHIN THE REQUIRED FENCING. I i EX. IRRIGATION G. RETAINING A CERTIFIED ARBORIST TO ENSURE TREES ARE PROTECTED FROM DEVELOPMENT ACTIVITIES. CONTROLLER H. ALTERNATE PROTECTION/SAFEGUARDS AS NECESSARY. I II 9. ALL PLANT MATERIAL TO BE TRANSPLANTED SHALL BE B&B WITH A FIBROUS ROOT SYSTEM ! I PROPOSED EXPANSION EXISTING SUFFICIENT TO SUPPORT THE CONTINUED SURVIVABILITY AND GROWTH OF THE PLANT MATERIAL EQUAL I I BUILDING TO ITS CONDITION PRIOR TO TRANSPLANTING. I (SAME FLOOR ELEVATION I ELEV. 21.67' 10. ALL TRANSPLANTED PLANT MATERIAL SHALL BE: I ! AS EXISTING BUILDING) I I MAX HEIGHT: 19'-6' A. HELD ON SITE AS DIRECTED BY THE LANDSCAPE ARCHITECT AND HEELED IN WITH TOPSOIL OR BARK TO PRESERVE/PROTECT ENTIRE ROOTBALL. I Q.0 I B. WATERED TO INSURE OPTIMUM WATER LEVEL AT ALL TIMES BY USING THE AUTOMATIC IRRIGATION I I CUT, CAP & SYSTEM AND HAND WATERING FROM DATE OF DIGGING TO CONDITIONAL ACCEPTANCE OF PROJECT. I I PROTECT EX. C. MAINTAINED BY WEEDING, STAKING AS NECESSARY, PROTECTING TOP GROWTH /CANOPY OF TREES AND I I LATERAL LINES SHRUBS TO ENSURE ALL PLANT MATERIAL IS AS EXISTING PRIOR TO DIGGING. FOR FUTURE 11. ANY TRANSPLANTED PLANT MATERIAL NOT RESPONDING POSITIVELY AS DETERMINED BY THE I // ZONE RESTORATION LANDSCAPE ARCHITECT SHALL BE REMOVED FROM SITE. TRANSPLANTED PLANT MATERIAL TO BE REPLACED SHALL BE SELECTED BY THE LANDSCAPE I o 0 0 0 T12. ARCHITECT AND PURCHASED/DELIVERED/INSTALLED BY THE LANDSCAPE CONTRACTOR. I 13. ALL PLANT MATERIAL TO BE REMOVED SHALL HAVE ENTIRE FIBROUS ROOT SYSTEM AND ALL TOP I \ NEW 2, 4" SCH GROWTH REMOVED FROM PROJECT AREA. I \ V 22 40 SLEEVES_ 14. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FURTHER SITE DEMO AFTER PLANT MATERIAL TO I -7 EX. SIDEWALK BE TRANSPLANTED/REMOVED IS COMPLETED AND EXISTING IRRIGATION IS CAPPED AND PROTECTED. I AREA #2 r T 19. CUT, CAP AND PROTECT EXISTING LATERAL LINES TO BE RESTORED AS SHOWN ON PLAN. 20. REMOVE EXISTING VALVES, QUICK COUPLER, WIRES AND/OR OTHER IRRIGATION SYSTEM COMPONENTS IN EXISTING PLANTING AREAS . 21. THE AREAS NOTED ON THE IRRIGATION PLAN ARE TO INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING: A. AREA #1 • CAP AND PROTECT EXISTING MAINLINE IN PLANTING ISLAND ON SOUTH SIDE OF DRIVEWAY. • CUT AND PROTECT EXISTING WIRES IN VALVE BOX IN PLANTING ISLAND ON SOUTH SIDE OF DRIVEWAY. • INSTALL 2 NEW 4" SCH 40 SLEEVES ACROSS DRIVE AISLE AS SHOWN ON PLAN. • SPLICE WIRES IN VALVE BOX AND PULL NEW WIRES TO EXISTING CONTROLLER FOR NEW VALVES AND RESTORATION OF EXISTING IRRIGATION SYSTEM. • 2" OR 2 J" MAINLINE TO BE REPLACED (VERIFY SIZE). B. AREA #2 • INSTALL NEW 1" VALVE #1 FOR ZONE TO WATER NEW PLANTING BEDS ON THE NORTH AND EAST SIDE OF THE NEW BUILDING ADDITION. • INSTALL NEW MAINLINE AND WIRES ENTIRE LENGTH OF NORTH/EAST PLANTING BED TO RECONNECT TO EXISTING CAPPED MAINLINE & TO EXISTING CONTROLLER. • INSTALL 1" QUICK COUPLER IN NORTH PLANTING BED AS SHOWN ON PLAN. • INSTALL NEW SPRINKLER IRRIGATION HEADS TO COVER ALL NEW & EXISTING TO BE RESTORED PLANTING BEDS. C. AREA #3 • INSTALL 2 NEW 4" SCH 40 SLEEVES ACROSS DRIVEWAY FOR RESTORATION OF EXISTING PLANTING AS SHOWN ON PLAN. INSTALL NEW 1 J" VALVE #2 FOR CONNECTION TO EXISTING LATERAL ZONE FOR COVERAGE OF WEST FACE OF EXISTING BUILDING. • VERIFY AND RESTORE SPRINKLER COVERAGE OF PLANTING BED ADJACENT TO VAULT TO REMAIN AND EXISTING PLANTING BED AT NW CORNER OF THE EXISTING BUILDING. D. AREA #4 • CUT, CAP AND PROTECT EXISTING LATERAL LINES TO BE RESTORED AT NE CORNER OF EXISTING BUILDING AS SHOWN ON PLAN. • INSTALL 1 J" VALVE #3 FOR CONNECTION TO AND RESTORATION OF LAWN ZONE FOR EAST SIDE OF EXISTING BUILDING. • INSTALL 1 J" VALVE #4 FOR CONNECTION TO AND RESTORATION OF SHRUB ZONE FOR EAST SIDE OF EXISTING BUILDING. E. AREA #5 • LOCATE EXISTING 4" SCH 40 SLEEVE UNDER SIDEWALK AT NE CORNER OF EXISTING BUILDING. • LOCATE EXISTING 2" OR 2 J" (VERIFY SIZE) OF EXISTING MAINLINE IN SLEEVE CROSSING DRIVEWAY AS SHOWN ON PLAN. • INSTALL NEW CONNECTION FROM SLEEVE UNDER SIDEWALK AND THROUGH PLANTING BED WITH EXISTING TRANSFORMER TO EXISTING SLEEVE UNDER DRIVEWAY. • CONNECT NEW MAINLINE FROM SLEEVE UNDER SIDEWALK TO EXISTING SLEEVE AND MAINLINE CROSSING DRIVE AISLE AS SHOWN. • VERIFY MAINLINE CONNECTION TO EXISTING VALVE. AS SHOWN NN''°�991� CITY OF RENTON °NON DATUM Planning/Building/Public Works Dept. IF Nor = m ► SWU AC AREA #3 LIMIT OF EV' T PROJECT _II l ------- - LIMIT OFF ---- - __- - --- ----- PROJECT \\ D -- - NEW 2, 4° SCH H. -- f -- LIMIT OF SD ----- 40 SLEEVES PROJECT_4`1- - - - - - - - - - - - - - CUT CAP & PROTECT ~--- EX. MAINLINE & WIRES AREA #1 FOR RECONNECTION T TO NEW & RESTORED IRRIGATION SYSTEM EX. j Q.C. 1 t DRIV WAY EX. PLANKING TO REMIAIN, TYP. F-11 _ IRRIGATION PLAN SCALE: I "= 20'-0" z 10 0 10 20 30 40 50 Scale Feet STATE Cr WA:i#iiNGT0N REGISTERED C.EiinWATE W. 274 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TREE RETENTION / LAND CLEARING 7/3/17 (TREE INVENTORY) PLAN & IRRIGATION PLAN 'a°°M pma US BANK EXPANSION oawNNo Noe 2500 EAST VALLEY ROAD L 1.0 RENTON, WASHINGTON 98057 "m 1 cr:2 R-39671 0 W 496�8 LIMIT OF _ — — I PROJECT— ... 7 _ —___ _ �- W� _ LIMIT OF — — PR JECT + 15" ABH I I I I � I TRANS. WATER MAIN SIDEWALK�� EASEMENT EX. LIGHT TO REMAIN � PROTECT FROM DAMAGE cfl EX. LANDSCAPE r� I TO REMAIN \ N I N w �/ I EXISTING PLANTING AREA 00 — _ o /' i I CONCRETE CURB CONCRETE PAVING POT / CONTAINER REMOVE POT OR CONTAINER AND ROUGHEN / CUT SIDE OF ROOTBALL IF ROOTS ENCIRCLE OR ARE HEAVILY MATTED B&B REMOVE TWINE AND 1/3 TOP OF BURLAP ON ROOTBALL 00 : V) NEW PLANTING + + + AREA + NtW.WAL+c. I. o zo 5,-5„ i I —I 17" ABH 2'-0" OR AS DIRECTED BY LANDSCAPE ARCHITECT + PROPOSED EXPANSION (SAME FLOOR ELEVATION I EXISTING BUILDING AS EXISTING BUILDING) MAX HEIGHT: 19'-6" ELEV. 21.67' + C EXISTING RAISED POWDER COATED PLANTER TO1 REMAIN METAL PANELS SEGMENT OFIIPROPOSED + 10—INCH DIA. OF + I REPLACEMENIT WATER + MAIN — I 7'— 5 I 0 0 0 I o NEW PLANTING • AREA I ., AREA OF NEW 14 1 2" ABH I ;� c PLANTING FH 3' WORK ° LIMIT OF CLEARANCE I PROJECT 1 RADIUS FROM OF FH EX. SIDEWALK F.H. F_ I 7" ABH �— 2 EX. ————— ---------------fi---- I -------------------- RHODODENDRON TO REMAINo �` J ° uGP _______� EVI FDC 3' WORK - - - ! --I— -------- ------ UG ----- � _ / CLEARAN E RADIUS • FROM OF FDC ---------------------� — — — — X. PLANTINGI — — — -- — — I AREA I ----I--------- �--�--1—�\ -- - — LIMIT OF \� PROJECT I LIMIT OF I I � —c,� ------- -- -- — PROJECT D--------- L ------- -----------J�---- - --— - --- MLH. --- S� I I 1 PLANTING PLAN — ADD PLANS / NOTES LANDSCAPE PLANTING PLAN 2 LANDSCAPE NOTES REVISED 5 0 5 10 15 20 25 30 SCALE: I °= 10'-0" 0 Z Scale Feet NO. REVISION 2" MULCH. HOLD DOWN 2" FROM TOP OF CURB AND ROLL BACK INTO PLANTING BED MAKING A "V" TRENCH — TOPSOIL AS —_ SPECIFIED SUBGRADE HOLD DOWN 4" FROM TO OF CURB CONTRACTOR SHALL REMOVE ALL LABELS, TAGS, OR OTHER FOREIGN MATERIALS FROM BRANCHES. PRUNE ONLY DEAD OR BROKEN BRANCHES ----i 'NRICJ — RCFCR IV VI CENTER SPECIFICATION MULCH — 2" UNIFORM DEPTH EXCEPT ADJACENT TO THE ROOTBALL HOLD MULCH DEPTH TO 1" FINISH GRADE TOPSOIL AS SPECIFIED. ROUGH SIDES AND BOTTOM OF PLANTING PIT UNDISTURBED SUBGRADE. PLANT SHALL BEAR SAME RELATION TO FINISH GRADE AS IN NURSERY. SCARIFY PIT BOTTOM. VERIFY POSITIVE DRAINAGE BEFORE PLANTING SHRUB. ,SHRUB PLANTING DETAIL 'L1102 SCALE: N TS 'DISTANCE OF O.C. SPACING PER PLAN LEGEND TRIANGULAR LAYOUT OF PLANT MATERIAL, TYP. PLATING BED CURB TYPICAL SHRUB/GROUNDCOVER TRIANGULAR PLANTING DETAIL 'Drawing1 SCALE: NTS HK 8/16/17 sum: HK 8/16/17 oemo�e HK 01M"ft BB/LS amomm HK BY DATE APPR AK saw AS SHOWN �a wu soKa IF Nor oN[ Npl SOMA LANDSCAPE PLANTING PLAN LEGEND m DATU M N N FOR 54" 2 ACER RUBRUM 'RED SUNSET' RED SUNSET MAPLE EXISTING TO REMAIN SEE PLANTING PLAN FOR DIAMETER ABH ® 54" 7 RHODODENDRON X 'DAPHINOIDES' DAPHINOIDES RHODODENDRON SPECIMEN 5-6' H X 6-8' W 5 TO BE TRANSPLANTED 2 EXISTING TO REMAIN, PRUNE ALL RHODODENDRONS UNDER THE DIRECTION OF LANDSCAPE ARCHITECT 3 JUNIPERUS CHINENSIS 'TORULOSA' HULLYWUUD JUNIPER SPECIMEN 8-9' TRANSPLANT AS SHOWN ON PLAN n 26 MAHONIA EURYBRACTEATA 'SOFT CARESS' PLANT PATENT #20,183 SOFT CARESS MAHONIA 5 GAL. ® S-0" O.C. 7 PRUNUS LAUROCERASUS 'OTTO LUYKEN' OTTO LUYKEN LAUREL 21-24" @ S-0" O.C. EXISTING OTTO LUYKEN HEDGE TO REMAIN 15 DRYOPTERIS ERYTHROSORA 'BRILLANCE' AUTUMN FERN 2 GAL. ® S-0" O.C. OR AS SHOWN 231 GAULTHERIA PROCUMBENS WINTERGREEN 1 GAL. ® V-0" O.C. 96 RUBUS CALYCINOIDES 'EMERALD CARPET' EMERALD CARPET BRAMBLE 1 GAL. ® 1'-0" O.C. NOTES: REFER TO CIVIL SHEETS FOR PLANTER SIZES AND DIMENSIONS. STATE OF • REGISTERED e • 1 CITY OF RENTON ling/Building/Public Works Dept. LANDSCAPE NOTES: 1. SEE SHEET L1.0 LANDSCAPE NOTES AND IRRIGATION NOTES FOR GENERAL PROJECT PROCEDURES, PLANT MATERIAL TRANSPLANTING, IRRIGATION DEMO AND RESTORATION, TREE PROTECTION AND OTHER ITEMS AS NOTED. 2. ALL WORK AREAS SHALL BE KEPT CLEAN, NEAT AND ORDERLY AT ALL TIMES. DIRT AND RUBBISH SHALL BE KEPT OFF PAVED AREAS DURING CONSTRUCTION. PROJECT AREA SHALL BE LEFT CLEAN AND NEAT AT THE END OF EACH WORKDAY. 3. ALL NEW PLANTING AREAS SHALL HAVE PAVING, DEBRIS, LITTER, ROCKS OVER 2" AND ALL EXISTING SOIL REMOVED FROM PLANTING AREA TO A CONSISTENT DEPTH OF 2'-0" OR AS DIRECTED BY LANDSCAPE ARCHITECT. 4. ALL PLANTING AREAS SHALL EXHIBIT FREE DRAINING CONDITIONS FOR THE ENTIRE PLANTING AREA. SCARIFY PLANTING AREAS AS NECESSARY. 5. TOPSOIL TO BE USED FOR ALL NEW PLANTING BEDS AND/OR PLANTING PITS PER DETAILS. 6. INSTALL TOPSOIL PER CITY OF RENTON ORDINANCE NO 5528/J/SOIL REQUIREMENTS: SOIL WILL BE PREPARED ACCORDING TO INDUSTRY STANDARDS TO BE CONDUCIVE TO THE HEALTHY GROWTH OF NEW PLANTS. TOPSOIL SHALL BE RICH IN ORGANIC MATERIAL OR AMENDED TO BE SO. CLAY SOIL IS NOT ACCEPTABLE AND MUST BE REMOVED FROM LANDSCAPE AREAS IF NATURALLY PRESENT ON SITE. 7. TOPSOIL SHALL BE A 3—WAY MIX FROM CARPINITO BROTHERS/KENT, WA CONSISTING OF 60% KENT VALLEY LOAM, 30% STEER MANURE AND 10% SAND OR EQUAL . 8. MULCH SHALL BE MEDIUM BARK MULCH AS PROVIDED BY CARPINITO BROTHERS/KENT, WA OR EQUAL. 9. PROVIDE SAMPLE OF TOPSOIL AND MULCH TO THE LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION ON SITE. 10. ALLOW FOR COMPACTION IN PLACING TOPSOIL IN ALL PLANTING AREAS. 11. LANDSCAPE CONTRACTOR WILL BE RESPONSIBLE FOR ADJUSTING ALL VALVE BOXES AND WATER METER BOXES TO CORRECT FINISH GRADE DRUING INSTALLATION OF TOPSOIL AND FINISH GRADING. 12. PLANT MATERIAL WILL BE FIRST QUALITY AS DETERMINED BY THE LANDSCAPE ARCHITECT AND WILL BE REMOVED FROM SITE AND REPLACED IF REJECTED. 13. PLANT MATERIAL WILL BE FULLY ROUNDED, BRANCHED EVENLY AND UNIFORM IN SHAPE. 14. ALL PLANT MATERIAL WILL BE MAINTAINED AND WATERED TO INSURE OPTIMUM WATER LEVEL AT ALL TIMES DURING PROJECT WHETHER IN HOLDING AREA OR PLANTED. 15. ALL ROOTBALLS OF B&B AND WIRE BASKET PLANT MATERIAL WILL BE COVERED WITH TOPSOIL, MULCH OR OTHERWISE PROTECTED AS APPROVED BY LANDSCAPE ARCHIECT PRIOR TO PLANTING UNLESS PLANTED IMMEDIATELY UPON DELIVERY. 16. INSTALL "V" TRENCH PER DETAIL IN ALL BEDS ADJACENT TO SIDEWALKS OR CURBS. 17. ALL PLANT MATERIAL WILL BE PLANTED IN TOPSOIL WITH THE TOP OF ROOTBALL LEVEL WITH FINISH GRADE. PLANTS INSTALLED ABOVE GRADE AND BACKFILLED WITH MULCH WILL BE REPLANTED OR REJECTED. 18. PROVIDE AND PLACE 2" BARK MULCH IN CONTINUOUS LEVEL MANNER IN ENTIRE AREA (WIDTH/LENGTH) OF RAISED PLANTER AND ALL OTHER NEW OR EXISTING PLANTING AREAS WITHIN LIMITS OF PROJECT. 19. A FINAL WALK THROUGH WILL BE SCHEDULED FOR POJECT COMPLETION AND PUNCH LIST GENERATED AS NECESSARY. ALL ITEMS ON THE PUNCH LIST MUST BE COMPLETED BEFORE CONDITIONAL ACCEPTANCE OF THE PROJECT. 20. LANDSCAPE MAINTENANCE OF THE ENTIRE PROJECT SHALL BE THE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR UNTIL CONITIONAL ACCEPTANCE. THIS INCLUDES, BUT IS NOT LIMITED TO, WEEDING, RE —STAKING OF PLANT MATERIAL, DEBRIS/LITTER AND LEAF REMOVAL, WATERING, REPAIR OF VEHICLE OR PEDESTRIAN DAMAGE TO PLANTING BEDS, REPAIR OF PLANTING BED DAMAGED BY OTHER CONTRACTORS AND REPLACEMENT OF STOLEN OR VANDALIZED MATERIALS OR PLANT MATERIAL. 21. WARRANTY/GUARANTEE ALL PLANT MATERIAL, MATERIAL AND WORKMANSHIP FOR ONE YEAR FOLLOWING CONDITIONAL ACCEPTANCE OF PROJECT. 22. REPLACE ANY DEAD OR DYING PLANT MATERIAL AS REQUIRED BY THE LANDSCAPE ARCHITECT THROUGH THE WARRANTY/GUARANTEE PERIOD. 23. ALL REPLACEMENT PLANT MATERIAL SHALL BE AS ORIGINALLY SPECIFIED ON THE PLAN EXCEPT FOR TRANSPLANTED MATERIAL. 24. TRANSPLANTED MATERIAL TO BE REPLACED SHALL BE SELECTED BY LANDSCAPE ARCHITECT AND PURCHASED/ DELIVERED/INSTALLED BY LANDSCAPE CONTRACTOR. 25. AFTER THE WARRANTY/GUARANTEE PERIOD HAS ENDED AND ALL PLANT MATERIAL HAS BEEN REPLACED AS NECESSARY, THE LANDSCAPE ARCHITECT WILL CERTIFY THE PROJECT WITH FINAL ACCEPTANCE. IN COMPLIANCE WITH CITY OF RENTON STANDARDS LANDSCAPE PLANTING PLAN AND DETAILS 7/3/17 US BANK EXPANSION 2500 EAST VALLEY ROAD RENTON, WASHINGTON 98057 �asoae PAM to L1.1 allo� 2 af:2 R-39671 1