Loading...
HomeMy WebLinkAboutVideo Inspection Report Pipeline Video and Cleaning 35849 Military Rd S,Auburn,WA 98001 Video Inspection Summary 800.TV.A.PIPE 253.661.0828 PO or Job#: Date: 06/02/09 Company: Seaport Dozing & Development, Truck number: 0 Inc. Project Name: Key Plaza Assigned job number: Address: 4501 NE 4th St Inspector: City, State: Renton WA Technician: Kelley Page Tape No. Starting MH Ending MH Type Size Material Direction Cleaned Length 1 1 MH-1 Existing Sanitary 8" PVC Downstream No 66.5 2 1 - MH 1 MH-2 Sanitary 8" PVC Upstream No 122.5 3 1 MH-2 Building Sanitary 6" PVC Upstream No 70.8 Summary for Key Plaza(3 detail records) Total footage: 259.8 , Pipeline Video and Cleaning Video Inspection Report 35849 Military Rd S,Auburn,WA 98001 800.TV.A.PIPE 253.661.0828 Assigned ID: PO or Job# Start Date 6/2/2009 Client: Seaport Dozing & Development, Inc. Legal description or orientation.: Project Name: Key Plaza Address: 4501 NE 4th St City: Renton State: WA Technician: Mark Kelley Weather: Clear Truck Number: 0 Inspector: - None t,Starting,`Structure . ,'" Depth Ending,Structure , Depth; . Direction - Videb Ref .LinexLerigth ' MH-1 N/A Existing N/A Downstream 0:00:01 66.5 Lirie,Type:` Pipe Type Size Ref;Ball '' Air Test Air'Quality f;Ventilated 1ftlandrell`. Pass °. Sanitary PVC 8" 1 in N/A N/A N/ANo N/A bate Cleaned Comments ` - Tape:_, 6/2/2009 No 1 Footage Position Comments Severity Notes Photo Clip Vid Ref 1 0.0 1 I Start of inspection-center line of structure i i ❑ 0:00:01 j 2 66.5 ( j End of inspection center line of structure , ❑ I Page 1 of 3 1 Pipeline Video and Cleaning Video Inspection Report 35849 Military Rd S,Auburn,WA 98001 800.1V.A.PIPE 253.661.0828 _........ e" "..nvwwwr '3:.....x....:y.cttz�.s »»....-n....-.w«..d.� 1 .. ,.,.,w.,.....:..._ ..,....-....«.a.w .«..�Aw....,«e.w.».a_..w.....m... '�ma�aW.,.,_..x...u9Ld Assigned ID: PO or Job# Start Date 6/2/2009 Client: Seaport Dozing & Development, Inc. Legal description or orientation: Project Name: Key Plaza Address: 4501 NE 4th St City: Renton State: WA Technician: Mark Kelley Weather' Clear Truck Number.. 0 Inspector. - None Starting•Str'ucture.> 4 Depth x;Ending•Structure:.., Depth:.,, Direction ' f°Video Ref., .',tine Length?` MH-1 N/A MH-2 N/A Upstream 0:00:02 122.5 .Line Type:°•°, .-''_,}pipe Type:;,` -.;=Size . Ref:Ball:..: Air.Test • Veritilafed°Air-Quality: fVlandrelf: Pass:, Sanitary PVC 8" 1 in N/A N/A N/A No N/A Date ,;:Cleaned: Comments:_, z Tape: 6/2/2009 No 1 Footage Position Comments Severity Notes Photo Clip Vid Ref 1 0.0 Start of inspection-center line of structure l El 10:00:02 2 78.4 I Service lateral left- 1 it 3 122.5 I End of inspection-center line of structure 1 E Page 2 of 3 `. it - Pipeline Video and Cleaning Video Inspection Report . 35849 Military Rd S,Auburn,WA 98001 800.TV.A.PIPE 253.661.0828 Assigned ID: PO or Job# Start Date 6/2/2009 Client: Seaport Dozing & Development, Inc. Legal description or orientation: Project Name: Key Plaza Address: 4501 NE 4th St City: Renton State: WA Technician: Mark Kelley Weather' Clear Truck Number: 0 Inspector:. - None Starting,Structure _, Depth•: Ending St"rupture .' ,Depth: , Direction VideoX:Ref Line Length , MH-2 N/A Building N/A Upstream 0:00:03 70.8 Line Type , *, Pipe*Type.:, ,`S ie WRef,Ball,ti,,Air Test Alr Quality„ =Ventilated Mandreli Pass Sanitary PVC 6" none N/A N/A N/A� No N/A ';:'',:';'.:0.4*?':'::,',' Cleaned Comments fi. °. E,.x R Taper 6/2/2009 No 1 Footage Position Comments Severity Notes Photo Clip Vid Ref 1 0.0 I Start of inspection-center line of structure j ❑ 0:00:03 2 69.0 1 i Service lateral left- II ❑ 1 3 70.8 1 I End of inspection-cleanout i 7 111 Page 3 of 3