HomeMy WebLinkAboutR-404235IRRIGATION EQUIPMENT SCHEDULE:
z
z
z
0
w
CD
0
J
0
rr
IL
LO
HUNTER IRRIGATION EQUIPMENT SHOWN IN SCHEDULE. TORO. RAINBIRD, WEATHERMATIC OR EOLIIVALENT IRRIGATION EQUIPMENT MAYBE SUBSTITUTED,
WITH LANDSCAPE ARCHITECTS WRITTEN APPROVAL ONLY.
SYMBOL DESCRIPTION P.SJ, RADIUS
VALVE KEY "A"
2
a.
LU
JLU
U)
cry C7 ❑
® ® HUNTER MFLC 515, MFRCS515, MPSS530 STRIP ROTATOR HEAD, WITH MATCHED PRECIPITATICINI DATES 30 4x28', 4'x14'
1A 1 ilk"
26 MAX
HUNTER IMP DG0 ROTATOR, 12' ADJUSTABLE ARC AND RAID IUS NOZZLE, WITH MATCHED PRECIPITATION RATES
30 12'
1" -
DRIP
—
$
16 MAX.
HUNTER MP2000 ROTATOR, 17' & 18' ADJUSTABLE ARC AND RADIUS NOZZLE, WITH MATCHE1D PRECIPITATION RATES
34 17'-1 W
16 MAXI
DRIP
p
HUNTER MP300() ROTATOR, 27' ADJUSTABLE ARC AND RADIUS NOZZLE, WITH MATCHED PRECIPITATION RATES
30 27''
4a I"'
16 MAX
DRIP
p` w
HUNTER NIP CORNER ROTATOR, 12' RADIUS HEADS, ADJUSTABLE ARC NOZZLE, WITH MATCHED PRECIPITATION RATES
30 12+
5A 1 112"
25 MAX
-
6a 1'
16 MAX
DRIP
HUNTER PRO -SPRAY SHORT RADIUS NOZZLES - 4' RADIUS
TO 4'
-
79 1"
16 MAX
DRIP
.
HUNTER PRO -SPRAY SHORT RADIUS NOZZLES - Z RADCUS
30
—
I
I3a #�
16 MAC
DRIP
HUNTER PRO -SPRAY POP-UP SPRAY HEADS, 5 NOZZLE
30 5'
gal 1"
16 MAX
DRIP
rs " cs
HUNTER FRO -SPRAY POP-UP SPRAY HEADS, 8 NOZZLE (FOR ADJUSTABLE ARCS, TT AND TO HEAD USE NOZZLE 8A}
30 8'
-
10A► 1 112"
25 MAX
HUNTER PRO -SPRAY POP-UP SPRAY HEADS, 10 NOZZLE (FOR ADJUSTABLE ARCS, TT & TO HEAD USE NOZZLE 10A)
30 1 D<
-
110 1'
16 MAXDRIP
'Q } p
HUNTER PRO -SPRAY POP-UP SPRAY HEADS, 12 NOZZLE (FOR ADJUSTABLE ARCS USE NOZZLE12A)
30 12'
-
12e 1"
16 MAX
DRIP
HUNTER PRC PRAY POP-UP SPRAY HEADS, 15 NOZZLE (FOR ADJUSTABLE ARCS USE NOZZLE 15A)
30 15'
1a 1"
16 MAX
DRIP
HUNTER PRO=SPRAY POP-UP SPRAT' HEADS, 17' NOZZLE (FOR ADJ. ARCS. T. TT, TO, & F HEAD USE NOZZLE 17A)
30 17,
14a 1"
16 MAX
DRIP
E! 16 0
HUNTER STRIP PATTERN - L CORNER, R CORNER, SIDE STRIP, END STRIP, & CENTER STRIP
30 5'x3U, Sx15'
15a 1"
15 MAX
DRIP
BRASS GATE VALVE - RuS Ball VaIve - Made1 S95F43 (Round Han die)'- SIZE TO FIT MAINLINE
-
-'
168 1"
16 MAX
DRIP
eF�
BACKFLOW ASSEMBLY - FEBCO LF850 (SIZE TO MATCH METERS
_ --
-
17a 1"
16 MAX
DRIP
AUTOMATIC CONTROL VALVE, HUNTER PGV, SEE VALVE KEY
18p, 1 11
25 MAX
1-112" WATER METER (BY OTHERS.- COORDINATE POC WITH CONSTRUCTION MANAGER)
_
19a 1"
1E MAX
DRIP
QUICK COUPLER - HUINTER HQ44-LRC-AkW
- - -- --
0
OPEN
RAIN 'SENSOR - HUNTER RAIN-CLI -WIRELESS RAIN SENSOR (WRC-TNT) OFF EQUAL, SEE G ENERAL DOTE C
1
OPEN
Ln
CONTROLLER - HUNTER 1-CORE IC-600 PL, ICM-500 WI DUAL DECODER (24 STATION EXTERIOR, WALL MOUNT. PLASTIC ENCLOSURE)
OPEN
CLASS 200 PVC LATERAL LINE PIPING, SIZE PER PLAIN
23
OPEN
'F
-Y •-- - - -- -
" SCHEDULE 40 PVC MAINMAINLINE
24
OPEN
.r.-..t-.-. -..
CLASS 200 PVC SLEEVE 2X PIPE DIAMETER. 4" MIN.
Not Shawn
#14 AWG TYPE OF CONTROL WIRE, FEED = SIGNAL. WHITE = COMMON, ORANGE = SPARE
SIZE PIPING AS FOLLOWS:
0-8GPM =314"PIPE
9-16 GPM = 1" PIPE
17- 24 GPM = 1 1A"
PIPE
DRIP IRRIGATION EQUIPMENT SCHEDULE:
33:50 P = "'PiIPEIPE
SYMBOL MSCRIPTION P.S.I. GPH
HUNTER DRIP LINE - PLD-04-12 (12" EMITTER SPACING x 12" ROW SPACING) 15-50 A0
HUNTER DRIP LJNE - PLD-04-18 (18" EMITTER SPACING x 18" ROW SPACING) 15-'50 .40
HUNTER DRIP LINE - BLANK TUB$NG (HEADER) - PIDL-BLINK-18
1" CLASS 200 PVC SUB -RAIN LINE (FOR DISTRIBUTION TO HEAD-ERB)
AIRIVACUUM RELIEF VALVE (PLACED AT HIGH POINT OF ZONE)
LINE FLUSHING VALVE
DRIP ZONE CONTROL KIT - PCZ-101-40 (INCLUDES CONTROL VALVE. 40 PSI PRESSURE REGULATOR & FILTER)
NOTE: DESIGN ASSUMES 50 PSI STATIC WATER PRESSURE AT POINT OF CONNECTION AND 30 PSI DESIGNED PRESSURE
MOTES,
1, DO NOT ALLOW VAULT TO REST ON PIPE.
2. USE MANUFACTURERS VALVE BOX
EXTENSIONS AS NECESSARY
3. PROVIDE 2 CUBIC FOOT DRAIN ROCK
SUIMP IN EACH VAULT,
16" MIN,
Control ,Valve Assembly
(Not To Scale)
AUTOMATIC CONTROL VALVE -SEE SCHEDULE
FOR MANUFACTURER AND SIZING
UNION, TYPICAL
FLUSH W1 FINISH GRADE
NBS PRO SERIES VALVE BOX OR APPROVED
EQUAL,VALILT TO EXTEND MIN, 6" BELOW
VALVE- USE EXTENSIONS AS NECESSARY -TWO
VALVES PER VAULT MAXIMUM
SCH 80 PVC NIPPLE, TYP.
PVC 90 ELBOW S x TH
MAIN LIME
DO NOT AL LOW VAULT TO REST DN PIPE
UA I t VALVt t-KLO 9 Not I LK
Main Assn
(NGt To Scala)
K01 >, 7-1 1 ;l 1144 1 Wj
7
Revised
per City/Site
Plan Comm.
Revised ber CiVl$Hke Plan LCqmm.
Revised per lity Plan Comm.
10
Revised ed
er City/Site
Plan Comm.
11
Revised
Der CitflSite
Plain Comm.
NO, I REVISION
GENERAL NOTES
A. IRRIGATION DESIGN ASSUMES 65 PSI STATIC WATER PRESSURE iS
AVAILABLE ON SITE. VERIFY STATIC WATER PRESSURE IN FIELD PRIOR TO
CONSTRUCTION. NOTIFY LANDSCAPE ARCHITECT IF STATIC WATER PRESSURE
IS LESS THAN 55 PSI, IRRIGATION DESIGN IS BASED ON 30 PSI,
B- USE 4" POP-UP HEADS WITHIN ALL LAWN AREAS AND 6" POP-UP HEADS
WITHIN ALL SHRUB AREAS, 12" POP-UP HEADS ARE OPTIONAL IN SHRUB BEDS
WITH OWNERS REQUEST.
C. RAIN SENSOR TO BE INSTALLED ON SOUTH OR WEST SIDE DF BUILDINO,
AT A MINIMUM OF 8 FEET ABOVE GRADE WHERE SENSOR IS FREE FROM
VANDALISM, TREE CANOPIES, BUILDING OVER HANGS OR OTHER STRUCTURAL J
NATURAL RAIN IMPEDIMENTS. COORDINATE LOCATION WITH CONSTRUCTION
MANAGER.
IRRIGATION NOTES
1. PLAN IS DIAGRAMMATIC. VERIFY LOCATION OF STRUCTURES, UTILITIES
AND OTHER SITE ELEMENTS PRIOR TO COMMENCING WORK, €NOTIFY
PROJECT MANAGER OF ANY CONFLICTS.
2. CONTRACTOR TO TEST EXISTIfNG WATER PRESSURE AN PROVIDE WRITTEN
REPORT TO PROJECT MANAGER PRIOR TO COMMENCING WORK.
3- REVIEW ALL IRRIGATION DETAILS PRIOR TO COMMENCING WORK,
4, REFER TO EQUIPMENT SCHEDULE FOR ALL IRRIGATION HEAD TYKES AND
EQUIPMENT-
5. PROVIDE 2 (TWO) SPARE WIRES FROM THE CONTROLLER TO THE
FURTHEST VALVE LOCATIONS FOR FUTURE EXPANSION.
6- STATE ALL VALVE BOX LOCATIONS FOR APPROVAL.
7, SET VALVE BOXES SQUARE TO ADJACENT BUILDING. CURB OR PAVING.
8- ALL IRRIGATION UNDER ROADS, WALKS. PARKING AREAS OR OTHER PAVED
SURFACES SHALL BE SLEEVED- SLEEVES SHALL BE 2 (TWO) TIMES THE
DIAMETER OF THE INSERTED PIPE OR AS IiND€GATED,
9, ALL PIPING IS DIAGRAMMATIC- PIPING SHOWN WITHIN PALING OR
ADJACENT) PARALLEL TO PLANTED AREAS ARE INTENDED TO BE PLACED
WITHIN PLANTING BEDS WHERE POSSIBLE- ALL MATERIAL TO BE INSTALLED
ON OWNER'S PROPERTY.
10. MAKE ANY AND ALL REQUIRED ADJUSTMENTS TO THE IRRIGATION PLAN
TO ASSURE COMPLETE AN ADEQUATE COVERAGE +KITH MINIMUPA OVER
SPRAY,
11. WHEN SLEE ING, PIPING OR HEAD LAYOUT IS REQUIRED IN R.O.W„
CONTRACTOR TO COORDINATE LOCATION WITH THE PROJECT ENGINEER
PRIOR TO CONSTRUCTION. IND€CANE EXACT LOCATION OF SLEEVES AND
PIPING, ON THE AS -BUILT DRAWINGS-
12. PLACE TRACE WIRE ON ALL IRRIGATION PIPING AT OWNER'S REQUEST.
1a. LATERAL LINE SHALL HAVE MINIMUM 12" OF COVER AND MAINLINES A
MINIMUM OF 18" COVER-
14. PROVIDE MANUAL DRAINS AT ALL LOW POINT ON THE MAIN LIME AN
RECORD ACCURATELY ON AS -BUILT DRAWINGS.
15, LOCATE IRRIGATION BACK -FLOW PREVENTOR DOWN -STREAM OF SITE
WATER METER (WATER METER BY OTHERS). VERIFY LOCATION WITH
PROJECT MANAGER PRI:0R TO COMMENCING WORK.
16- COORDINATE LOCATION OF CONTROLLER WITH PROJECT MANAGER.
INSTALL CONTROLLER AT 60" ABOVE (FINISH FLOOR l FINISH GRADE) ON
EXTERIOR WALL OF (BUILDING), PROVIDE A 110 GFI POWER OUTLET AT
CONTROLLER LOCATION FOR POWER SUPPLE*. PROVIDE CONDUIT FROM
IRRIGATION CONTROLLER LOCATION TO OUTSIDE PLANTING BED. FLAG ALL
LOCATIONS,
FLUSH WITH FINISH GRADE
DOUBLE CHECK VALVE FESCO 850 (MATCH
METER SIZE)
QUICK COUPLER VALVE
MASTER VALVE
— NBS PRO SERIES VALVE BOX OR APPROVED
EQUAL. SIZE & QUANTITY AS REQUIRED
DRAIN ROCK, 6" DEPTH THROUGHOUT
NOTES
1. DO NOT ALLOW VAULT TO REST CAN PIPE. USE
EXTENSIONS AS NECESSARY,
2. VALVE TO BE SET PLUMB.
3, CONTRA4CTOR TO PROVIDE QCV KEY WITH
SWIVEL HOSE ELL ATTACHED
4. PROVIDE 6" DEPTH DRAIN ROCK.
FLUSH W! FINISH GRADE
CARSOIN STANDARD VAULT OR EQUAL
QUICK COUPLER
SS HOSE CLAMP (3)
SCH 80 PVC NIPPLE
BRASS ST. ELL & 90°l %127 ELL
SCH 80 PVC NIPPLE, 12" LENGTH
BRASS TT 90 AND 3" LENGTH SCH 80
PVC NIPPLE
STEEL 7 FENCE POST, 36" LENGTH
MAIN LINE
Quick Coupler
(Not To Scale)
— SPRAY OR BUBBLER NOZZLE
— FLUSH Wl FINISH GRADE
_ NOZZLE & BODY PER SCHEDULE AND
PLAN. USE BOTTOM INLET ONLY
— (2)112" MARLEX ST. ELL 90
17 MIN, SCH 80 PVC NIPPLE, MIN 8- LENGTH
— V2" MARLEX STREET ELL 90
- SCH 80 PVC FITINGS, TYP,
CL 200 PVC LATERAL, TYP, SIZE AS
INDICATED ON PLAN
Pop7uVHead
(Not To Scale)
RECORD DRAWING
03-15-2021
NO RECORD INFORMATION
SHOWN ON THIS SHEET.
fjl]
BRADLEY DESIGN
-�_
GROUP, Inc.
'0
Land�capeArch ltecture
Site Planning
4330 N. Lexington Street
Tacoma, WA 98407
STATE OF
WASH INGTON
REGISTERED
LANDSCAPE A KrECT
ale R
.67
"''�INOUA
architects
050 Pacific Avenue, Suite 450
Tacoma, VVA 98402
53-57-4003
ient,
r
,t
PROLOGIS,,
12720 Gateway Dr., Suite 110
Tukwila, WA 98168
206-4 1 4-7625
R-404235
IN COMPLIANDE WITH CITE' OF RE N STANDARDS
PI-ANNING OWSION
APPROVED
01116,2020 Ealing
L
04101
19
s e,
� yA�fwrt
As
LL:iA4Vh,9�
kOpL�tMJT JT/ifLLdh�993'19B'
_
—
eDATIUM
CITY F
E I N T I N
PlanningJBuilding/Pub€ic Works Dept.
P R L I S R E T N 9
01 MONSTER ROAD
Record Drawing documents 03-15-2021
IRRIGATIONHEDULE, DOTES DETAILS
11116118
F�118L
F L
0
07/101
1
o�l{�Itu
YS`
P�FB°°":
L
07/25/19
rinowft
9HE INCH
TATWALE
scue oocwair+our
oa�rw� txa
IR-
' L
10/18/19
L'FILCJKt° R
BY
DATE
APPR
*PH""-
SHEET.
38 51
co
T_
F
An
N
CD
00
J
LO
C)
0
co
CL
V�
0
LU
0
J
0
IL