This document contains no pages.
HomeMy WebLinkAboutRC 20120215002365 111111111111 1111111
20120215002365
67.00
CITY OF
PAGE-001 OF006
02/15/2012 1
KING COUNTY, UA
RECORDING REQUESTED BY AND
WHEN RECORDED MAIL TO:
CITY CLERK'S OFFICE
CITY OF RENTON
1055 SOUTH GRADY WAY
RENTON,WA 98057
DECLARATION OF COVENANT
FOR MAINTENANCE AND INSPECTION OF FLOW CONTROL BMPS
Grantor: .�.. e c, tSsrn*e. V ,LLC
Grantee:City of Renton
Legal Description: PeArcd 2. " Lok Line Ad,. 1s0 LUA-pi -Oil -LLA
etc No 2OotiD62_-iOOon 3,
Additional Legal(s)on:
Assessor's Tax Parcel 1D#: 33L4 LI c) - O Sto 5
IN CONSIDERATION of the approved City of Renton(check one of the following)fir residential
building permit,❑commercial building permit, ❑clearing and grading permit,❑subdivision permit,or
❑ short subdivision permit for Application File No.LUA/SWP relating to the
real property("Property")described above,the Grantor(s),the owner(s)in fee of that Property,hereby
covenants(covenant)with City or Renton,a political subdivision of the.state of Washington,that '
he/she(they)will observe,consent to,and abide by the conditions and obligations set forth and described
in Paragraphs 1 through 8 below with regard to the Property. Grantor(s)hereby grants(grant),
covenants(covenant),and agrees(agree)as follows:
1.. Grantor(s)or his/her(their)successors in interest and assigns("Owners")shall retain,uphold,
and protect the stormwater management devices,features,pathways,limits,and restrictions,known as
flow control best management practices("BMPs"),shown on the approved Flow Control BMP Site Plan
for the Property attached hereto and incorporated herein as Exhibit A.
2. The Owners shall at their own cost,operate,maintain,and keep in good repair,the Property's
BMPs as described in the approved Design and Maintenance Details for each BMP attached hereto and
incorporated herein as Exhibit B.
3. City or Renton shall provide at least 30 days written notice to the Owners that entry on the
Property is planned for the inspection of the BMPs. After the 30 days,the Owners shall allow the City of
Renton to enter for the sole purpose of inspecting the BMPs. In lieu of inspection by the City,the
Owners may elect to engage gag a licensed civil engineer registered in the state of Washington who has
expertise in drainage to inspect the BMPs and provide a written report describing their condition: If the
engineer option is chosen,the Owners shall provide written notice to the City of Renton within fifteen
days of receiving the City's notice of inspection. Within 30 days of giving this notice,the Owners,or the
engineer on behalf of the Owners,shall provide the engineer's report to the City of Renton. If the report
is not provided in a timely manner as specified above,the City of Renton may inspect the BMPs without
further notice.
4. If the City determines from its inspection,or from an engineer's report provided in accordance
with Paragraph 3,that maintenance,repair,restoration,and/or mitigation work is required for the BMPs,
The City shall notify the Owners of the specific maintenance,repair,restoration,and/or mitigation work
(Work)required under RMC 4-6-030. The City shall also set a reasonable deadline for completing the
Work or providing an engineer's report that verifies completion of the Work. After the deadline has
passed,the Owners shall allow the City access to re-inspect the BMPs unless an engineer's report has
been provided verifying completion of the Work. If the work is not completed properly within the time
frame set by the City,the City may initiate an enforcement action. Failure to properly maintain the BMPs
is a violation of RMC 4-6-030 and may subject the Owners to enforcement under the RMC 1-3,including
fines and penalties.
5. Apart from performing routine landscape maintenance,the Owners are hereby required to
obtain written approval from the City or Renton before performing any alterations or modifications to the
BMPs.
6. Any notice or approval required to be given by one party to the other under the provisions of
this Declaration of Covenant shall be effective upon personal delivery to the other party,or after three(3)
days from the date that the notice or approval is mailed with delivery confirmation to the current address
on record with each Party. The parties shall notify each other of any change to their addresses.
7. This Declaration of Covenant is intended to promote the efficient and effective management of
surface water drainage on the Property,and it shall inure to the benefit of all the citizens of the City of
Renton and its successors and assigns. This Declaration of Covenant shall run with the land and be
binding upon.Grantor(s),and Grantor"s(s')successors in interest and assigns.
8. This Declaration of Covenant may be terminated by execution of a written agreement by the
Owners and the City of Renton that is recorded by King County in its real property records.
•
IN WITNESS WHEREOF,this Declaration of Covenant for the Maintenance and Inspection of
Flow Control BMPs is executed this 10';day of i)e c,ev i b e.( ,20 I ( .
G TOR,owner of the Property
GRANTOR,owner of the Property
STATE OF WASHINGTON )
COUNTY OF KING )ss.
Onjthis day� personally appeared before me:
( ) - 'G'� "`�' ,to me known to be the individual(s)described in
and who executed the within and foregoing instrument and acknowledged that they signed the same as
their free and voluntary act and deed,for the uses and purposes therein stated.
Given under my hand and official seal thi gday of L pJ p>�, ,20 // .
JANE F. OLSEN �-- eD/s. 47
STATE OF WASHINGTON
Printed name
NOTARY PUBLIC Notary Public in and for the State of Washington,
MY COMMISSION EXPIRES residing at
04-03-15 Vece,`� 1
My appointment expires O 4 0 3-
r
EXHIBIT A; FLOW CONTROL BMP SITE PLAN
TOTAL LOT/SITE AREA: 6,030 SF DOSING PERVIOUS AREA: 4679 Sc-
ADDRESS:
FADDRESS: 2816 LAKE WASHINGTON BLVD N PROPOSED PERVIOUS AREA: 2,964 SF
PARCEL NUMBER: 3342100565 EXISTING IMPERVIOUS AREA: 2,351 SF
PERMIT it PROPOSED IMPERVIOUS AREA: 3,066 SF
SW 7/4 SEC 31, TWP 24N, RBE 5E, W.M.
RANDOM FILL MAX IMPERVIOUS SURFACE:
SITE ZONE: R-8
�5'
LOT SF: 6,030 SF
6'"` € FILTER FABRIC PROP IMPERVIOUS SURFACE 3,066 SF
miamompromo
f8'MIN += MAXIMUM ALLOWABLE IMPERVIOUS SURFACE i
_.- _ ai ' 6"PERF PIPE SURFACE IS NOT TO EXCEED: 920 SF
ti'% SCALE: 1" = 30'
24'MIN. "WASHED 1530
ROCK
KCSWDM DETAIL C.2.11.A
NTS
INGRESS EGRESS AND
UTILITY EASEMENT PER
LOT UNE ADJUSTMENT
'''''':> •z -2" 1 I 1 I
PRIVATE 15 `'' .:1:''...• tr,. ; •"� • -'`. / I I l 1
WATER EASEMEN • • x,_ L �/ ��I i
PER LOT UNE S ..',;Pr, 3 --- "4
•:',`
ADJUSTMENT .v1‘ . 7.
,.:7.'
ti T >. = 3:-; . 98' .. t
,; k.-:.:: 'd?•V' = ,iii ,iii, i,,l
,', ,:4.4'k.:�`' Y "a+ . ,jA:
\ X10♦'/ / I O
/
4 �.�` \ t,Ir1. LOT 2 ? 1
:\:.' o-L ` R�ms., \ 1 f/.. • !'A/. f
�.`` f 1
' '
f te? ' 63
— ——
Ex
:•1, ,•I ..' \e` UNE."GAS'
'.•. :. \ \
RIM 67.14 : 41).•!y \
'Q.': .'..
8"/E 59.94(S£)..::.'.:'::..'.''!�.,. .,._"`':•\ ``....
Jon 12.2012—1:07pm—User ctuytor
E:\Projrcts\11063\0w9\814P Plans\11063-811P-Lot 2.ow9
' r SCALE. AS NOTED FLOW CONTROL DESIGN JOB NUMBER:
PROJECT MANAGER KEN 7l2ETL PLS 11-063
-``' LA2820 LAKE WASH BLVD
V f'- DESIGNED BY l�UT TA{Htt£PE EXHIBIT
APPROVED BY LOT 2
BLOELMNE PLOT DATE January 12 2012 _ ©2012 THE BLUEUNE GROUP A
ISOLA RESIDENCE
EXHIBIT B
DECLARATION OF COVENANT
PERFORATED PIPE CONNECTION MAINTENANCE INSTRUCTIONS
This lot contains a stormwater management flow control BMP (best management practice) called
a "perforated pipe connection," which was installed to reduce the stormwater runoff impacts of
some or all of the impervious surface on your property.A perforated pipe connection is a length of
drainage conveyance pipe with holes in the bottom, designed to "leak" runoff, conveyed by the
pipe, into a gravel filled trench where it can be soaked into the surrounding soil.The connection is
intended to provide opportunity for infiltration of any runoff that is being conveyed from an
impervious surface (usually a roof) to a local drainage system such as a ditch or roadway pipe
system.
The size and composition of the perforated pipe connection as depicted by the flow control BMP
site plan and design details must be maintained and may not be changed without written approval
from the City of Renton. The soil overtop of the perforated portion of the system must not be
compacted or covered with impervious materials.
RESTRICTIVE FOOTPRINT MAINTENANCE INSTRUCTIONS
Your property contains a stormwater management flow control BMP (best management practice)
known as "restricted footprint," the practice of restricting the amount of impervious surface that
may be added to a property so as to minimize the stormwater runoff impacts caused by
impervious surface. The total impervious surface on your property may not exceed 3 g 2O
square feet without written approval from the City of Renton.