Loading...
HomeMy WebLinkAboutR-405420"t w U) n Z J r2 _V LLJ < C/ v / rr ('111 LLJ U f. RENTO DRAIN 1/2" LETTERING - BOLT HOLES - 3 PLACES EQUALLY SPACED 120° APART ON 23 1/16"DIA. B.C. (1) 1" DIA. PICKHOLE PLAN VIEW �11/4"LETTERING 25" DIA. 1. 3/4" 2 1/2" 8 3/4" (TYP.) COVER SECTION VIEW 26 1/2" DIA. 25 1/4" DIA. NEOPRENE GASKET 1 � i 23 oto DIA. CI OPEN 27 5/16" DIA. 34 1/8" DIA. FRAME SECTION VIEW PUBLIC WORKS PRI DEPARTMENT 15• MAX. FOR MAINTENANCE SE 1/4 SECTION 14, TOWNSHIP 23 N, RANGE 5 E, W.M. CEDARS A T THE HIGHLANDS FRAME & ROUND SOLID COVER MARKED "DRAIN" W/ LOCKING BOLTS COVER BOTTOM VIEW RIM = t422.84 , H16" MAX. O (3) BLT SOC. (ALLEN HEAD) 5/8"-11 x 1.5 SS RUBBER WASHER O 7 min EON BOLTING DETAIL I I I o 1 1/16" 1/8" R1/8" GASKET GROOVE DETAIL NOTES: 1. ALL COVERS SHALL BE LOCKING LID PER EJ No. 3717C1 OR APPROVED EQUAL. STORM ROUND FRAME AND COVER 28" MAX. "O" RING 12" s•• 48-,54-,60"' 8",54",60", 72", 84 96", 120" OR 144" UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (N DS STD. PLAN - 204.50 PPggVep:Z 9/28/2018 1 o,esa nmme,ma„ DATE 1,, Works Adm.,,tritar CATCH BASIN FRAME AND VANED GRATE PER STD. PLAN 204.00 RECTANGULAR OR CIRCULAR ADJUSTMENT SECTION (TWO SECT ONS MAX.) - MORTAR, (TYP.), SEE NOTE 5 FLAT SLAB TOP STEPS OR LADDER 12" (TYP.) 1" MINiNTEGR.ALBAS IN24" 2.5" MAORCING STEEL, (TYP.) f. MIN. GRAVEL BACKFILL FOR PIPE ZONE BEDDING PER WSDOT STD. SPECIFICATION SECTION 9-03.12(3) SEPARATE BASE PRECAST PRECAST WITH RISER SEE NOTE 6, TYP. NOTES: 1. NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS. 2. THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE SLOPED TO FACILITATE CLEANING. 3. THE RECTANGULAR FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION. 4. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 5. ALL GRADE RINGS, RISERS, AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 6. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL), WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 7. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 8. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 9. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. • PUBLIC WORKS �I� DEPARTMENT r � Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER MIN. WALL THICKNESS MIN. BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS 48" 4" 6" 36" 8" 54" 4.5" B. 42" 8" 60" 5" 8" 48" 8" 72" 6" 8" 60" 12" 84" 8" 12" 72" 12" 96" 8" 12" 84" 12" 120" 10.. 12" 96" 12" 144" 12" 12" 1081• 12" PIPE ALLOWANCES CATCH BASIN PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER DIAMETER CONCRETE ALL METAL CPSSP, SOLID WALL pVC z PROFILE WALL PVC, 48" 24" 30" 24" 30" 30" 54' 30" 36" 30" 36" 36" 60" 36" 42" 36" 42" 42" 72" 42" 1 54" 1 42" 1 48" 1 48" 84" 54" 60" 54" 48" 1 48" 96" 60" 1 72" 60" 48" 48" 120" 66" 1 84" 1 60" 1 48" 48" 144" 78" 1 96" 1 60" 1 48" 1 48" ' CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-05.20) Z STD. SPEC. 9-05.12(1) a STD. SPEC. 9-05.12(2) CATCH BASIN TYPE 2 UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NT STD. PLAN - 201.00 PRO GAZ 9/28/2018 1 P„err Work. Aamm -l., DATE L. PI EIjIS of WASH 1 C w 53232 _ �SSIDNAL b�p•lg ZA 20" 5 S• 2", 4", 6", 12", OR 24" ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 RECTANGULAR ADJUSTMENT SECTION 6 gEENO�� SF��OT 26 FS / #3 BAR EA #3 E PRECAST BASE SECTION #3 BAR HOOP #3 BAR EACH CORNER 18" MIN. SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION PUBLIC WORKS [;R DEPARTMENT D.R. STRONG CONSUL TING ENGINEERS ENGINEERS PLANNERS SURVEYORS 620 - 7th AVENUE KIRKLAND, WA 98033 O 425 827 3063 F 425 827 2423 PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR PLAIN CONCRETE 12" ALL METAL PIPE 15" CPSSP`, STD. SPEC. 9-05.20 12" SOLID WALL PVC, STD. SPEC. 9-05.12(1) 15" PROFILE WALL PVC, STD. SPEC. 9-05.12(2) 15" ` CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES: 1. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. 2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5 FEET. 4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. 5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1 H:24V OR STEEPER. 6. THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2). 8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 9. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 11, ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 200.00 APPR ED: CATCH BASIN TYPE 1 GAZ 9/28/2018 P 1.m Wo, A-....o-auo, DATE 1 CITY COMMENTS 02.19.19 1 CITY COMMENTS 05.03.19 NO. I REVISION STEPS OR LADDER,• EPDXY COA TED STEEL 12" INLET PIPE INVERT = 40750 PER PLANS SHEAR GATE W/ CONTROL ROD FOR CLEANOUT DRAIN (ROD BENT AS REQ D FOR VERTICAL ALIGNMENT W/CO VER) ALUMINUM ALLOY CB 208 - CONTROL STRUCTURE O - 2' MIN 0 2' MIN 0 2' MIN 54 "0 DESIGN W.S. = 419.00 PIPE SUPPOR IS - SEE NOTE 6 4" ELBOW /E = 416.91 ORIFICE 0=1.22" 4" ELBOW IE = 415.47 ORIFICE 0=1.75" 12"0 INLET PIPE FROM VAUL T /E= 407. 50 SHEAR GATE W/ CONTROL ROD FOR CLEANOUT DRAIN (ROD BENT AS REQ D FOR VERTICAL ALIGNMENT W/COVER) ALUMINUM ALLOY 1L w /T/JG(C L W /LG I r/rG IE= 407. 50 1.5 X DIA. PLAN VIEW MIN. SCALE 1" = 2'-0" NO TES.- 12" OUTLET PIPE 1. USE A MINIMUM OF A 54" DIAMETER TYPE TWO CATCH BASIN. INVERT = 407.50 PER PLANS 2. OUTLET CAPACITY: 100-YR DEVELOPED PEAK FLOW 3. METAL PARTS: CORROSION RESISTANT. NON -GALVANIZED PARTS ONLY. - 12"0 ALUMINUM OR ALUMINIZED 4. FRAME AND LADDER OR STEPS OFFSET SO: STEEL CMP RISER A. CLEANOUT GATE IS VISIBLE FROM TOP. B. CLIMB -DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. C. FRAME IS CLEAR OF CURB. 5. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE- OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1/4" RESTRICTOR PLATE 6. PROVIDE AT LEAST ONE 3 X 090 GAUGE SUPPORT BRACKET ANCHORED TO W/ 1.08"0 ORIFICE CONCRETE WALL. (MAXIMUM 3' VERTICAL SPACING) 7. SMOOTH EDGE 4OOT LOCATE ELBOW RESTRICTOR(S) AS NECESSARY TO PROVIDE MINIMUM 50 CLEARANCE AS SHOWN. 8. TEE SHALL BE CONSTRUCTED OF ALUMINUM CMP OR ALUMINIZED STEEL CMP MEETING WSDOT/APWA STANDARDS. 12"0 FROP REMOVABLE WATERTIGHT RISER COUPLING OR FLANGE FROP NO TES: 1. OUTLET CAPACITY: 100-YR PEAK FLOW 2. METAL PARTS: CORROSION RESISTANT. NON -GALVANIZED PARTS PREFERRED. GALVANIZED PIPE PARTS TO HAVE ASPHALT TREATMENT 1. J. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1/4" 4. PROVIDE AT LEAST ONE 3'X.090 GAUGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM 3' VERTICAL SPACING) 6„ 5. LOCATE ELBOW RESTRICTOR(S) AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SHOWN. MAX PLATE WELDED TO ELBOW - WITH ORIFICE AS SPECIFIED ELBOW RESTRICTOR DETAIL N IS N N TS T- T 0 WA �J ( co T C) O C) T I D J .e V ) R-405420 z Z IN COMPLIANCE WITH CITY OF RENTON STANDARDS J 2 DEVELOPMENT ENGINEERING (� bbannwarth 07/01 /2019 _ W SURFACE WATER UTILITY N _ ~ jfarah 07/05/2019 DRD 04.11.19 YLP SURVEYED: JGR SCALE: AS NOTED VERTICAL: NAVD 1966 HORIZONTAL: NAD 1983/1991 • C T Y 0 CEDARS AT THE HIGHLANDS STORM DRAINAGE DETAILS DATE: o� else, 9 Q U) CYW 06.20.19 YLP DESIGNED: YAP FIELDBOOK: , RENTON PAGE: DRAWN: DRAWING N0: C 2 0 GLB ONE INCH DATUM 1�1 • Planning/Building/Public Works Dept. 14120160TH AVENUE S E Q w CHECKED: YLP AT FULL SCALE IF NOT ONE INCH BY DATE APPR SCALE ACCORDINGLY RENTON, WASHINGTON 98059 APPROVED SHEET: OF: 20 DRS PROJECT NO. 16041