DECLARATION OF COVENANT
FOR MAINTENANCE AND INSPECTION OF FLOW CONTROL BMPS
Grantor: 1 ! Orr T7^"i1A Awe', twc..
Grantee:City of Renton
Legal Description: IOC t•ttzr14 -zoo fret'(- Ai5 r' oot -r- •,T&f
► 1. rt. - - ice TfT -DF
112Aer ' 4;314544- (.DAM 'tt A<1 c TrAerS f V �OLUM12
Additional Legal(s)on:Fsb6E OI p c(JAMS 144#4 4 CA. ' / tA/Aftfilielt0
Assessor's Tax Parcel ID#: 0047/0 ` 004'
IN CONSIDERATION of the approved City of Renton(check one of the following) residential
building permit,O commercial building permit,O clearing and grading permit,❑ subdivision permit,or
Cl short subdivision permit for Application File No.LUA/SWP relating to the
real property("Property")described above,the Grantor(s),the owner(s)in fee of that Property,hereby
covenants(covenant)with City or Renton,a political subdivision of the state of Washington,that
he/she(they)will observe,consent to,and abide by the conditions and obligations set forth and described
in Paragraphs 1 through 8 below with regard to the Property. Grantor(s)hereby grants(grant),
covenants(covenant),and agrees(agree)as follows:
1. Grantor(s)or his/her(their)successors in interest and assigns("Owners")shall retain,uphold,
and protect the stormwater management devices,features,pathways,limits,and restrictions,known as
flow control best management practices("BMPs"),shown on the approved Flow Control BMP Site Plan
for the Property attached hereto and incorporated herein as Exhibit A.
2. The Owners shall at their own cost,operate,maintain,and keep in good repair,the Property's
BMPs as described in the approved Design and Maintenance Details for each BMP attached hereto and
incorporated herein as Exhibit B.
3. City or Renton shall provide at least 30 days written notice to the Owners that entry on the
Property is planned for the inspection of the BMPs. After the 30 days,the Owners shall allow the City of
Renton to enter for the sole purpose of inspecting the BMPs. In lieu of inspection by the City,the
Owners may elect to engage a licensed civil engineer registered in the state of Washington who has
expertise in drainage to inspect the BMPs and provide a written report describing their condition. If the
engineer option is chosen,the Owners shall provide written notice to the City of Renton within fifteen
days of receiving the City's notice of inspection. Within 30 days of giving this notice,the Owners,or the
engineer on behalf of the Owners,shall provide the engineer's report to the City of Renton. If the report
is not provided in a timely manner as specified above,the County may inspect the BMPs without further
notice.
4. If the City determines from its inspection,or from an engineer's report provided in accordance
with Paragraph 3,that maintenance,repair,restoration,and/or mitigation work is required for the BMPs,
The City shall notify the Owners of the specific maintenance,repair,restoration,and/or mitigation work
(Work)required under RMC 4-6-030. The City shall also set a reasonable deadline for completing the
Work or providing an engineer's report that verifies completion of the Work. After the deadline has
C1)004a — 20F b
passed,the Owners shall allow the City access to re-inspect the BMPs unless an engineer's report has
been provided verifying completion of the Work. If the work is not completed properly within the time
frame set by the City,the City may initiate an enforcement action. Failure to properly maintain the BMPs
is a violation of RMC 4-6-030 and may subject the Owners to enforcement under the RMC 1-3,including
fines and penalties.
5. Apart from performing routine landscape maintenance,the Owners are hereby required to
obtain written approval from the City or Renton before performing any alterations or modifications to the
BMPs.
6. Any notice or approval required to be given by one party to the other under the provisions of
this Declaration of Covenant shall be effective upon personal delivery to the other party,or after three(3)
days from the date that the notice or approval is mailed with delivery confirmation to the current address
on record with each Party. The parties shall notify each other of any change to their addresses.
7. This Declaration of Covenant is intended to promote the efficient and effective management of
surface water drainage on the Property,and it shall inure to the benefit of all the citizens of the City of
Renton and its successors and assigns. This Declaration of Covenant shall run with the land and be
binding upon Grantor(s),and Grantor's(s')successors in interest and assigns.
8. This Declaration of Covenant may be terminated by execution of a written agreement by the
Owners and the City of Renton that is recorded by King County in its real property records.
CAZU4AJT
•
U TEXT OF INSTRUCTIONS
Your property contains a stormwater management flow control BMP(best management practice)called a
"perforated pipe connection,"which was installed to reduce the stormwater runoff impacts of some or all of
the impervious surface on your property. A perforated pipe connection is a length of drainage conveyance
pipe with holes in the bottom,designed to"leak"runoff,conveyed by the pipe,into a gravel filled trench
where it can be soaked into the surrounding soil. The connection is intended to provide opportunity for
infiltration of any runoff that is being conveyed from an impervious surface(usually a roof)to a local
drainage system such as a ditch or roadway pipe system.
The size and composition of the perforated pipe connection as depicted by the flow control BMP site plan
and design details must be maintained and may not be changed without written approval either from the
King County Water and Land Resources Division or through a future development permit from King
County. The soil overtop of the perforated portion of the system must not be compacted or covered with
impervious materials.
FIGURE C.2.11.A PERFORATED PIPE CONNECTION FOR A SINGLE FAMILY RESIDENCE
random fill
6- /j//j���\\�< filter fabric
v o 4 o f 6 pert pipe
18"min o a°o ,Gia°av0
° v v /oo ° 0 11/2"-3/4"washed rock
n
a oa a oa as pd
°9° o ° a o
oc,
Q 00 v
AA c'° Dila OoP
O ° Q ° q 11 ° 4 ° D
141---24"min
TRENCH X-SECTION
NTS
slope —►
—II-to road
drainage system
2'X 10'
/level trench
w/perf pipe
PLAN VIEW OF ROOF
NTS aj S or
Exhibit B
Your property contains a stormwater management flow control BMP(best management practice)called
"full infiltration,"which was installed to mitigate the stormwater quantity and quality impacts of some
or all of the impervious surfaces on your property. Full infiltration is a method of soaking runoff from
impervious area (such as paved areas and roofs) into the ground. If properly installed and maintained,
full infiltration can manage runoff so that a majority of precipitation events are absorbed. Infiltration
devices,such as gravel filled trenches, drywells, and ground surface depressions,facilitate this process
by putting runoff in direct contact with the soil and holding the runoff long enough to soak most of it
into the ground. To be successful,the soil condition around the infiltration device must be reliably able
to soak water into the ground for a reasonable number of years.
The infiltration devices used on your property include the following as indicated on the flow control
BMP site plan:gravel filled trenches,drywells,ground surface depressions. The size, placement,and
composition of these devices as depicted by the flow control BMP site plan and design details must be
maintained and may not be changed without written approval either from the King County Water and
Land Resources Division or through a future development permit from King County.
Infiltration devices must be inspected annually and after major storm events to identify and repair any
physical defects. Maintenance and operation of the system should focus on ensuring the system's
viability by preventing sediment-laden flows from entering the device. Excessive sedimentation will
result in a plugged or non-functioning facility. If the infiltration device has a catch basin, sediment
accumulation must be removed on a yearly basis or more frequently if necessary. Prolonged ponding
around or atop a device may indicate a plugged facility. If the device becomes plugged, it must be
replaced. Keeping the areas that drain to infiltration devices well swept and clean will enhance the
longevity of these devices. For roofs,frequent cleaning of gutters will reduce sediment loads to these
devices