Loading...
HomeMy WebLinkAboutD-205707a � s• x T.O. WALL EL 415cff FENCE AND HANDRAIL NOT MOWN FOR CLARITY 3"0 PIPE i 8' GATE °M S JTEEL PIPE INSERT, WITH SEEP RINGREINF. AROUND OPENING PER FLEXIBLE WALL PENETRATION DETAIL, SHEET 4 EL 108.67 PVC BASIN LINER —/ USE 'REINFORCEMENT ARRANGEMENT AROUND OFENINGS' DETAILS PER SHEET 4 FOR TRIM BARS AROUND PIPE, TYP. INLET AND OUTLET STRUCTURES L —L 3wp- s7 -j6s7 i GRATING - W6 SPILLWAY I r4" 41267 #5 O 9 E.F. a 109.62 +E:6�rFr} 'T- I I t L. 106.52 0 _ 16012- \ I 1 EL VARIES CHAIN INK FENCE / -1 1/4• PIPE 'I m PIPE a ,C/o SID PIPE CE POSTS (OR HANDRAILS) INTO SLEEVE USING NON - SHRINK GROUT. ISPILLWAY HANDRAIL NOT SHOWN V -0" S-6" I 1 o. (,2 #4 OWLS 0 12 E.F. #6 0 12 E.F. GEOTEXTILE FABRIC EL 193ir7 #4 O 12 E.F. E.W. GATE / / , AND ? °p SUBDRAW PIPE HEAD LOOSE RIPRAP PVC LINER SEE CONCRETE ATTACHMENT DETAIL, SHEET 5, FOR WALL CONNECTION, FIELD FIT BELOW SUBDRAIN 102.40 #6 OWL O 12 E.F. i i #5012EF. L #5 012 ' -- - - - - -- - - - -- ------------ - -- HEAVY LOOSE RIPRAP — G - G GEOTEXTILE FABRIC H - H (SHEET 6) (SHEET 6) NOTE REINFORCEMENT FOR 27 -0" LONG WALLS IS TYPICAL 3, -0" GATE SEE NOTE 1 NOTE SET FENCE POSTS EITHER SIDE OF GATE OPENING TO ACC0,110DATE N -0" CLEAR GATE OPENING. FENCE ELEVATION (LOOKING UPSTREAM) NOT TO SCALE 1.E 16=4.7 101.41 EL �93.F7 #5 0 12 E.F. E.W. 4" PVC GATE VALVE, RYAN HERCO #5450 -040 FLANGED WITH S -6" LONG OPERATOR OR EQUAL., SEE NOTE 3 4"0 X 6" LG. GALV STEEL PIPE WITH MALE THREADS ON SCREEN END AND STD. FLG. ON VALVE END. SET PIPE INVERT AT EL 109.2 (VERIFY INVERT WITH CITY AFTER FIELD LOCATION OF EXISTING PIPE) - 4• PIPE INTAKE SCREEN, McMASTER CARR ITEM #4413K4, CAT. #100 OR EQUAL 10"1.10!0 r, O 12 it.W., E.F. i0 EL 101.17 V #4 0 12 E.W., E.F. #5 0 12, CONTINUOUS #4 0 12 EXTEND J INTO SECTION E -E SLAB i.4TO UPPER WALL- #5 0 12, CONTINUOUS FOR CUTOFF WALL (SHEET 6) 4 "0 PVC PIPE W/ FLG. AT VALVE END, SEE NOTE 2 (4) #4 BARS o 1-0 m i0 #5 0 12 E.W., E.F. (4) #4 EQ. SPC. E.F. (4) #4 BARS K (SHEET 6) GENERAL NOTES FOR MISC. METALS 1. ALL METALS SHALL BE GALVANIZED STEEL UNLESS NOTED OTHERWISE. 0 2. ALL STEEL PIPE HANDRAILS SHALL BE GALVANIZED AND SHALL CONFORM io TO OSHA STANDARDS. 3. STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 AND STEEL PIPE HANDRAILS TO ASTM A53 SCH. 40. (2) GALV. PIPE SUPPORT BRACKETS, NOTES' ITT GRINNELL FIG. 194.1, W/ GALV. PIPE 1. FENCE GATE REQUIRED WITH LATCH, LOCK AND CHAIN. CLAMP FIG. 104 AND 5/8.0 THREADED ROD FIG. 140. ATTACH BRACKETS TO WALL WITH 5/8.0 S.S. EXP. ANCHORS 2. 4 "0 PVC IRRIGATION PIPE, EXTEND DOWNSTREAM THRU BASIN LINER TO DETAIL 1 MATCH EXISTING PIPE AS SHOWN ON SHEET 2, MAINTAIN CONSTANT SLOPE FOR GRAVITY FLOW. CONFIRM EXISTING PIPE INVERT WITH CITY PRIOR (SHEET 6) TO CONNECTION. SCALE 0 1 FOOT 3. 2I40VIDE A GALVANIZED SLEEVE FOR VALVE OPERATOR LATERAL SUPPORT. I , , , I ATTACH TO WALL FOR RIGID CONNECTION. 3/4* 1'-0" 0 t RFCn' "kIF,NT)ED Q of 0o � FOR NORTHWEST. INC. a �� CITY OF RENTON Engineers and Scientists BY Bellevue, Washington {y 25792 E, DEPARTMENT OF PUBLIC WORKS BY 2353 -130TH AVE NE, SUITE 200 X35,t37'EQ' $ FBEUEw QB)ASHIN � 99005 StONAL G, MAPLEWOOD CREEK SEDIMENTATION BASIN TEL- t2�1 W -2455 RECONSTRUCTION AND IMPROVEMENT PROJECT E%PIRES 12 -21 -97 _j SPILLWAY SECTIONS AND DETAILS SCALE 0 3 6 FEET I , , I DESIGNED: R.S.P, HNW DATE: 7 -15 -96 FILE NAME: SHEET 3/8• m 1, —Q,. DRAWN: C.L.C. HNW EXCEPT AS NOTED A AS-BUILT NOTES ADDED Dw la 5 -11 -98 CHECKED: D.E.P„ HNW SCALE: AS NOTED nELO e�oR: PACE: NO. REVISION BY �PPR. DATE APPROVED: SHEET: 7 OF: 10 Aft Rm. T^ 0 0 b� s wa � z N o 0 v II 9 5 v