Loading...
HomeMy WebLinkAboutD-205704`rl n TARS TO BE SAME SIZE )ING AS OF. HORQ BARS WALL CORIAM DUAL (FOR USE AT ALL EXPOSED CORNERS UNLESS OTHERWISE INDICATED ON THE DRAWINGS) I N GALV AFTER FABRICATION MODULAR ° MECHANICAL SEAL a AB. / ¢ PIPE PENETRATING OR CONNECTING 1 TO STRUCTURE- 0 o � B.O. / PEA GRAVEL COMPACT o O c a a IN 6" MAX. LAYERS = BOTTOM 4 -#4 (TYP.) CATCH BASIN AASHTO H -20 LOADING. C CONTRACTOR RESPONSIBLE \\ j AS RECOMMENDED REINFORCEMENT CONTINUOUS BY MODULAR = CORRUGATED METAL PIPE MECHANICAL = COUNTERSINK DET. THROUGH JOINT ) = DOUGLAS FIR OA (4) = DIAMETER .1D = DRAWING WATERSTOP TYP. ALL VERTICAL = DOWEL EA = EACH F E = EACH FACE CONSTRUCTION JOINTS AND i EQ. = EQUAL EL WHERE SPECIFIED ON DETAILS E.W. = EACH WAY EXP. FORMED WEDGE. FLL WITH F.D. = FLOOR DRAIN JOINT SEALANT = FAR FACE FIN. JIM FNDN. CONCRETE THRUST BLOCK. 12"4 PIPE TYPICAL THR W BLOCK DEAL NOT TO SCALE 1k OPENING I i 1.3 1d + d2 I I I d1 /EXTRA BARS I I I 1.3 Id ( I r� SAME SIZE AS EXTRA BARS BUT NOT LARGER THAN 08 D FORMED WEDGE DUAL (REINFORCEMENT NOT SHOWN) EMBED SCH 80 PVC OR STD WT STL PIPE SLEEVE INTO STRUCNRE. OPENING ADDL LARNER BAR IF SLAB OR WALL IS OVER 12' THICK 4' (TYP.) PLACE CLOSE TO OPENING EQUAL TO AREA OF THE INTERRUPTED BARS. PLACE HALF ON EACH SEE. USE MINIMUM CLEAR SPACING NOTE 74S STANDARD IS TO BE USED FOR aVO4 -c UMMS THAN 2OX OF THE CLEAR SPAN BUT NOT MORE TWIN 6'-0' E.W. OTHERWISE SEE DRAWINGS, / SEAL MFR. 3/16 1/4x3 PVC OR SEEP RING ° STEEL PL SEEP RING WELDED TO SLEEVE ELEVATION LT 2 SECTION PIPE SLEEVE W/ MODULAR MECHANICAL SEAL TYPICAL F6S.E WALL. PEWTRA710N NOT TO SCALE (PROVIDE FLEXIBLE SEAL AT ALL PIPE CONNECTIONS TO CONCRETE STRUCTURES EXCEPT 42 "4 AND 72'4 RCP) SURFACING 0 -0 ou GALV AFTER FABRICATION MODULAR ° MECHANICAL SEAL a AB. / ¢ PIPE PENETRATING OR CONNECTING 1 TO STRUCTURE- 0 o � B.O. / PEA GRAVEL COMPACT o O c a a IN 6" MAX. LAYERS = BOTTOM 4 -#4 (TYP.) CATCH BASIN AASHTO H -20 LOADING. = CENTER TO CENTER CONTRACTOR RESPONSIBLE \\ j AS RECOMMENDED = CLEAR BY MODULAR = CORRUGATED METAL PIPE MECHANICAL OPENING ADDL LARNER BAR IF SLAB OR WALL IS OVER 12' THICK 4' (TYP.) PLACE CLOSE TO OPENING EQUAL TO AREA OF THE INTERRUPTED BARS. PLACE HALF ON EACH SEE. USE MINIMUM CLEAR SPACING NOTE 74S STANDARD IS TO BE USED FOR aVO4 -c UMMS THAN 2OX OF THE CLEAR SPAN BUT NOT MORE TWIN 6'-0' E.W. OTHERWISE SEE DRAWINGS, / SEAL MFR. 3/16 1/4x3 PVC OR SEEP RING ° STEEL PL SEEP RING WELDED TO SLEEVE ELEVATION LT 2 SECTION PIPE SLEEVE W/ MODULAR MECHANICAL SEAL TYPICAL F6S.E WALL. PEWTRA710N NOT TO SCALE (PROVIDE FLEXIBLE SEAL AT ALL PIPE CONNECTIONS TO CONCRETE STRUCTURES EXCEPT 42 "4 AND 72'4 RCP) SURFACING 0 -0 ou °d` ' AB. = ANCHOR BOLT IMPORTED BACKFIU , COMPACT = ASPHALT CONCRETE PAVEMENT IN 12" LAYERS 0 o � B.O. 0 0 0 O PEA GRAVEL COMPACT o O c a a IN 6" MAX. LAYERS = BOTTOM NOTE: DETAIL WILL SUPPORT CATCH BASIN AASHTO H -20 LOADING. = CENTER TO CENTER CONTRACTOR RESPONSIBLE (� )� FOR PIPE PROTECTION = CLEAR FROM HEAVIER LOADS = CORRUGATED METAL PIPE DURING CONSTRUCTION. MIN. ' ' MIN. ' TYPICAL SNGLE PIPE BEDDNG DEAL NOT TO SCALE (i f 7114 Ailif:r►i��:'.�i 1. ALL REINFORCEMENT PLACEMENT AND DETAILING SHALL CONFORM TO ACI 318 -95, ILEA LNG C0� REIiFORCEMEnITS FOR REINFORCED CONCRETE UNLESS OTHERWISE NOTED. 2. CONCRETE PROTECTION FOR REINFORCEMENT, UNLESS OTHERWISE NOTED ON THE DRAWINGS, SHALL HAVE A MINIMUM CONCRETE COVER AS FOLLOWS: BOTTOM OF FOUNDATION AND FOOTINGS = 3' BACKRLLED SURFACES = 3' SURFACES SUBJECT TO SUBMERGENCE = 3' EXTERIOR WALLS, SLABS, BEAMS AND COLUMNS = 2' INTERIOR WALLS, SLABS, BEAMS AND COLUMNS = 1 -1/2' 3. o-- INDICATES A BAR WITH A BEND TURNED TOWARDS THE OBSERVER. �— INDICATES A BAR WITH A BEND TURNED AWAY FROM THE OBSERVER. INDICATES A LAPPED SPLICE IN THE SAME PLANE, NOT A BEND IN THE BAR. 4. DIMENSIONS ARE TO THE CENTERUNES OF BARS UNLESS OTHERWISE SHOWN. 5. REINFORCEMENT PARALLEL TO EMBEDDED ITEMS SHALL MAINTAIN A MINIMUM CLEAR DISTANCE EQUAL TO 1 -1/2 TIMES THE MAXIMUM SIZE AGGREGATE 6. THE FIRST AND LAST BARS IN THE WALLS AND SLABS SHALL BEGIN AND END A DISTANCE EQUAL TO THE CLEAR COVER FROM EACH END OF THE MEMBER. 7. STIRRUPS IN BEAMS AND TIES IN COLUMNS ARE TO START AND END AT A MAXIMUM DISTANCE OF ONE -HALF OF THE ADJACENT BAR SPACING FROM THE FACES OF THE SUPPORTING MEMBERS UNLESS OTHERWISE NOTED. 8. MECHANICAL SPLICES MAY BE USED UPON APPROVAL OF THE ENGINEER. 9. ALL REINFORCING STEEL SHALL BE ASTM A615, GRADE 60, UNLESS OTHERWISE NOTED. 10. WHERE APPLICABLE SUBSTITUTE Idt OR Idh FOR Id IN ALL REINFORCEMENT DETAILS SHOWN ON THIS DRAWING. by .: ► � : i! ��i�a���l�i►�� O = SPACING CENTER TO CENTER AB. = ANCHOR BOLT A.C.P. = ASPHALT CONCRETE PAVEMENT B.F. = BOTTOM FACE B.O. = BLOCKQUT ELL = BOTTOM LAYER BOT. = BOTTOM C.B. CATCH BASIN C.C. = CENTER TO CENTER CA, = CONSTRUCTION JOINT CLR. = CLEAR C.M.P. = CORRUGATED METAL PIPE C.S. = COUNTERSINK DET. = DETAIL D.F. = DOUGLAS FIR OA (4) = DIAMETER DWG = DRAWING OWL = DOWEL EA = EACH F E = EACH FACE EL = ELEVATION (OR ELEV.) EQ. = EQUAL EL = EACH LAYER E.W. = EACH WAY EXP. = EXPANSION F.D. = FLOOR DRAIN F.F. = FAR FACE FIN. = FINISHED FNDN. = FOUNDATION GALV. = GALVANIZED GRTG. = GRATING HORIZ. = HORIZONTAL H.P. = HIGH POINT H.R. = HANDRAIL I.D. = INSIDE DIAMETER UNLESS OTHERWISE NOTED INSIDE FACE I.L. = INSIDE LAYER INV. = INVERT LB. (LBS.) = POUND(S) L.P. = LOW POINT MAX. = MAXIMUM MFR. = MANUFACTURER 6' 3/8' PVC WATERUCIP RECOMMENDED FOR APPROVAL BY— - -- -- B V' MIN. = MINIMUM M.L. = MIDDLE LAYER N.F. = NEAR FACE N.I.C. = NOT IN CONTRACT NO. = NUMBER NOS. = NUMBERS N.T.S. = NOT TO SCALE O.C. = ON CENTER O.D. = OUTSIDE DIAMETER O.F. = OUTSIDE FACE O.L. = OUTSIDE LAYER 0-0 = OUT M OUT OPNG. = OPENING OPP, = OPPOSITE P.C. = POINT OF CURVATURE P.C.C. = POINT OF COMPOUND CURVATURE P.I. = POINT OF INTERSECTION PL = PLATE P.T. = POINT OF TANGENCY 37 OR PRESSURE TREATED R = RADIUS REF. = REFER OR REFERENCE REINF. = REINFORCEMENT OR REINFORCING REQ'D = REQUIRED R.O. = ROUGH OPENING SIM. = SIMILAR SPA. = SPACE(S) SPECS = CONTRACT SPECIFICATIONS SS. = STAINLESS STEEL STD. = STANDARD STL = STEEL SYM. = SYMMETRY OR SYMMETRICAL T = TANGENT LENGTH T & 8 = TOP AND BOTTOM T.O.C. = TOP OF CONCRETE TYP. = TYPICAL U.O.N. = UNLESS OTHERWISE NOTED VERT. = VERTICAL W/ = WITH W/0 = WITHOUT WP = WORK POINT WS = WATERSTOP I 1 A E3? NORTHWEST, INC. Engineers and Scientists Bellevue, Washington 2353 -130TH AVE NE, SUITE 200 F206)ASO� 98005 TEL- (206) 882 -2455 1. BEFORE PLACING CONCRETE, SEE ALL unAWINGia, INCLUDING 'MANUFACTURERS' DRAWINGS, FOR ALL EMBEDDED ITEMS WHICH ARE REQUIRED IN THE PLACEMENT. 2. THICKNESSES SHOWN FOR WALLS AND SLABS ADJACENT TO UNDISTURBED SOIL OR R= ARE MINIMUM DIMENSIONS. 3. BEFORE PLACING CONCRETE, CARE SHALL BE TAKEN THAT ALL EMBEDDED ITEMS ARE IN POSITION AND SECURELY FASTENED IN PLACE 4. THE MINIMUM CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS SHALL BE fc =4,000 PSI, UNLESS OTHERWISE NOTED ON THE DRAWINGS OR IN THE SPECS. 1 M& fY d MGV 1 Lev O IYIW AND LAP SPLICE LENGTHS (UNL"� OTHERWISE INDICATED ON THE DRAWINGS) f'r. = 4.nnn PSI fu = Rn nm PSI TABLE NOTES (1.) ALL TABLE VALUES ARE IN INCHES. (2.) UNLESS OTHERWISE INDICATED ON THE DRAWINGS, ALL BARS ARE TENSION BARS. (3.) TENSION BARS GIVEN IN TABLE ARE FOR BARS SPACED AT LEAST 6 Id O.C. AND CONCRETE COVER IS GREATER THAN db. (4.) FOR OTHER CONDITIONS THE FOLLOWING MULTIPLIER SHALL BE USED: A. TENSION BARS SPACED LESS THAN 6 Id O.C. = 1.25 x TABLE VALUE B. 3- BAR - BUNDLES IN TENSION OR COMPRESSION = 1.50 x TABLE VALUE (5.) FOR OTHER CONDITIONS NOT INDICATED IN TABLE REFER TO ACI 318 -89. F2EINFC7RCING BAR ABE?FREVIATIONS Id = DEVELOPMENT LENGTH Idh = DEVELOPMENT LENGTH FOR HOOKED BARS Idt = DEVELOPMENT LENGTH FOR TOP BARS db = BAR DIAMETER REINFORCING BAR BILLING Sc IDENTIFYING A. TYPICAL BAR BIWNG IN PLANS SECTIONS AND ELEVATIONS: #6 O 6 N.F., LL WHERE BAR LENGTH AND NUMBER REQUIRED IS NOT GIVEN, THE CONTRACTOR SHALL DETERMINE SAME FROM BAR SPACING, LOCATION AND DIMENSIONS OF STRUCTURE B. TYPICAL BAR IDENTIFICATION: - - -#6 O 12 #8 (TYP.) C. TYPICAL DETAILW BAR BILLING: 8 #6 0 8 X 4' -6' E.F. SAMPLE BILLING: LOCATION OF END BAR IN A6 O 10 I #6 O 10 BILLING S DIMENSION "S" (IN INCHES) SHALL ALWAYS BE EQUAL TO THE SPACING OF ADJACENT REINFORCEMENT. 40 4 C rn o °o x p� Wm � a z °z a 0 DEVELOPMENT LENGTH LAP SPLICE LENGTH BAR SIZE TOP BARS OTHER BARS TOP BARS OTHER BARS 3 14 12 18 16 4 19 15 24 19 5 23 18 30 23 6 28 22 36 28 7 33 25 42 33 8 37 29 48 37 TABLE NOTES (1.) ALL TABLE VALUES ARE IN INCHES. (2.) UNLESS OTHERWISE INDICATED ON THE DRAWINGS, ALL BARS ARE TENSION BARS. (3.) TENSION BARS GIVEN IN TABLE ARE FOR BARS SPACED AT LEAST 6 Id O.C. AND CONCRETE COVER IS GREATER THAN db. (4.) FOR OTHER CONDITIONS THE FOLLOWING MULTIPLIER SHALL BE USED: A. TENSION BARS SPACED LESS THAN 6 Id O.C. = 1.25 x TABLE VALUE B. 3- BAR - BUNDLES IN TENSION OR COMPRESSION = 1.50 x TABLE VALUE (5.) FOR OTHER CONDITIONS NOT INDICATED IN TABLE REFER TO ACI 318 -89. F2EINFC7RCING BAR ABE?FREVIATIONS Id = DEVELOPMENT LENGTH Idh = DEVELOPMENT LENGTH FOR HOOKED BARS Idt = DEVELOPMENT LENGTH FOR TOP BARS db = BAR DIAMETER REINFORCING BAR BILLING Sc IDENTIFYING A. TYPICAL BAR BIWNG IN PLANS SECTIONS AND ELEVATIONS: #6 O 6 N.F., LL WHERE BAR LENGTH AND NUMBER REQUIRED IS NOT GIVEN, THE CONTRACTOR SHALL DETERMINE SAME FROM BAR SPACING, LOCATION AND DIMENSIONS OF STRUCTURE B. TYPICAL BAR IDENTIFICATION: - - -#6 O 12 #8 (TYP.) C. TYPICAL DETAILW BAR BILLING: 8 #6 0 8 X 4' -6' E.F. SAMPLE BILLING: LOCATION OF END BAR IN A6 O 10 I #6 O 10 BILLING S DIMENSION "S" (IN INCHES) SHALL ALWAYS BE EQUAL TO THE SPACING OF ADJACENT REINFORCEMENT. 40 4 C rn o °o x p� Wm � a z °z a 0