HomeMy WebLinkAboutS-048802(2) ON SHEET NUMBER G -2 THIS SECTION IDENTIFIED AS:
(1) DETAIL IDENTIFICATION SHOWN ON DRAWING G-1 AS:
q
`—DETAIL LETTER
ABBREVIATIONS,
SECTION NUMBER
G -2
SYMBOLS
GENERAL NOTES:
ABB
ABBREVIATIONS
EA
EACH
SHEET NUMBER ON
LS
LUMP SUM
S
SOUTH, SLOPE
EXISTING STRUCTURE 'A ASPHALT LIMITS
I. COORDINATE SYSTEM FOR EACH STREET IS AN ASSUMED SYSTEM BASED ON THE
ACI
AMERICAN .CONCRETE INSTITUTE
EF
EACH FACE
LT
L:EFi
� 9����
"�
SAN
SANITARY
x FENCE ® PROPOSED SEWER LINE
COORDINATES SHOWN IN THE COORDINATE SUMMARY.
AC
ASPHALTIC CONCRETE
E
EAST
IF THIS BAR DOES
NOT MEASURE
WHICH THE DETAIL
:(-il $1.4 r 43
RY R. C. E. NO. DATE
RS, INC.
SCD
SCREWED
--- -�- --- R/W CE
CONCRETE
2. VERTICAL CONTROL DATUM IS CITY OF RENTON: ELEVATIONS OF CONTROL POINTS ARE
ACP
ASBESTOS CEMENT PIPE
ESMT
EASEMENT
MAX
MAXIMUM
SCH
SCHEDULE
— RIGHT -OF -WAY LINE
SHOWN ON SHEET G-3.
AISC
AMERICAN INSTITUTE OF
ED
EDGE :F OIL
ME
MECHANICAL END
SO
STORM DRAIN
—�r-- EXISTING MANHOLE � TREES
3. UTILITY LOCATIONS SHOWN ARE APPROXIMATE AND BASED ON INFORMATION PROVIDED BY THE
STEEL CONSTRUCTION
ECR
END CURB RETURN
(COLLARED TYPE)
SEC
SECTION
EXISTING UTILITY — PROPERTY LINE
INDIVIDUAL AGENCIES, ACTUAL LOCATION MAY VARY. THE CONTRACTOR SHALL CALL THE 'ONE
ALUM
ANSI
ALUMINUM
AMERICAN NATIONAL
EL
ELEVATION (ELEV.)
MJ
MECHANICAL JOINT
SHT
SHEET
— 18' SD—
C} - -- WATER METER OR
CALL' CENTER AT I- 800 - 424 -5555 FOR UTILITY MARKING 48 HOURS IN ADVANCE OF ANY
EXCAVATION.
STANDARDS INSTITUTE
ED
EQUAL OR EQUATION
MH
MANHOLE
SIM
SIMILAR
CATCH BASIN
4. UTILITY CROSSING LOCATIONS AND ELEVATIONS SHALL BE VERIFIED BY THE CONTRACTOR A
APPROX APPROXIMATE
EW
EACH WAY
MIN
MINIMUM
SL
SLOPE OR SURVEY LINE
MINIMUM OF FIVE (5) PIPE LENGTHS IN ADVANCE OF INSTALLATION OF NEW MAIN.
ASA
AMERICAN STANDARDS
ASSOCIATION (NOW ANSI)
EXIST
EXISTING
MiSC
MISCELLANEOUS
SPECS
SPECIFICATIONS
5. STATIONING SHOWN IS ALONG THE CENTERLINE OF THE SEWER PIPE ALIGNMENT AS DEFINED
MIRK
MARKER
SO
SQUARE
BY THE PLACEMENT OF THE NEW MANHOLES.
ASME
AMERICAN SOCIETY OF
MECHANICAL ENGINEERS
EXPJT
E %T
EXPANSION JOINT
EXTERIOR
ML
MONUMENT LINE
SS
SANITARY SEWER
6. CITY OF RENTON STD, DETAILS ARE LOCATED WITHIN THE BOUND CONTRACT SPECIFICATIONS.
ASPH
ASPHALT
MON
MONUMENT
ST
STREET
ASTM
AMERICAN SOCIETY FOR
TESTING AND MATERIAL
FIN
FINISH
STA
STATION
7. THE HOURS OF WORK IN THE STREET RIGHT -OF -WAY SHALL BE LIMITED TO 7:00 A.M. TO
5:00 P.M. ON WEEKDAYS EXCEPT WITHIN IOO' OF SUNSET BLVD. N.E., WHICH SHALL BE LIMITED
AVE
AVENUE
FD
FLOOR DRAIN
N
NORTH
STD
STANDARD
TO THE HOURS OF 7:00 A.M. TO 2:30 P.M. (UNLESS OTHERWISE APPROVED IN WRITING BY THE
DEPARTMENT OF PUBLIC WORKS AT 235 - 2620). ALL STREET CLOSURES, PARTIAL OR FULL,
AWS
AMERICAN WELDING ASSOCIATION
F TO F
FACE TO FACE
NE
NORTH EAST
STL
STEEL
SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 24 HOURS IN ADVANCE. THE
AWWA
AMERICAN WATER WORKS
FF
FINISH FLOOR
NIC
NOT IN CONTRACT
STN STL
STAINLESS STEEL
POLICE DEPARTMENT. FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE.
ASSOCIATION
FIN GR
FINISHED GRADE
NO
NUMBER
8. CONTRACTOR TO PROVIDE BYPASS PUMPING WHERE NECESSARY TO MAKE CONNECTIONS AND
STRUCT
STRUCTURAL OR STRUCTURE
CONSTRUCT ALL PIPING AND APPURTENANCES. ALL BYPASS PUMPING METHODS SHALL BE
BK
BACK
FH
FIRE HYDRANT
NTS
NOT TO SCALE
SY
SQUARE YARD
APPROVED BY THE ENGINEER.
BLDG
BUILDING
FL
FLOWLINE / FLANGE
OC
ON CENTER
9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND
BLD FLG
BLIND FLANGE
FLGD
FLANGED
OD
OUTSIDE DIAMETER
T
TELEPHONE
ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION.
FUR
FLOOR
TAN
TANGENT
10. A COPY OF THE APPROVED PLANS AND SPECIFICATIONS MUST BE ON THE JOB SITE WHENEVER
BM
BENCH MARK
FPM
FEET PER MINUTE
ORIG
ORIGINAL
CONSTRUCTION IS IN PROGRESS.
BOT
BOTTOM
TB
TELEPHONE BOX
FPS
FEET PER SECOND
P
POLE OR POWER
TBM
TEMPORARY BENCH MARK
16 IN PAVED AREAS, ALL MANHOLE COVERS MUST SLOPE TO MATCH EXISTING PAVING.
BRG
BEARING
FT
FEET OR FOOT
PC
POINT OF CURVATURE
TEL
TELEPHONE
12. ASSIGNMENT OF THE CONTRACTOR'S RESPONSIBILITIES AND OBLIGATION FOR LOCATING,
B & S BELL AND SPIGOT
FTG
FOOTING
PE
PLAIN END
TEMP
TEMPORARY
PROTECTING AND REPAIRING DAMAGE TO THE EXISTING UNDERGROUND UTILITIES IS SHOWN IN
BV
BUTTERFLY VALVE
PIED
PEDESTAL
TH
THICK OR THICKNESS
SECTION 1 -07.17 OF THE SPECIAL PROVISIONS.
BVC
BEGIN VERTICAL CURVE
G
GAS
PERF
PERFORATED
TJB
TELEPHONE JUNCTION BOX
13. CONTRACTOR SHALL PROTECT FROM DAMAGE EXISTING WATER METER SERVICES OR OTHER
GA
GAGE
PI
POINT OF INTERSECTION
UTILITIES DURING THE INSTALLATION OF NEW SIDE SEWER SERVICE,
CN
CATCH BASIN
GALV
GALVANIZED
PK
PK NAIL
TMH
TELEPHONE MANHOLE
14. INSTALLATION OF 45 DEGREE WYE FITTING FOR SIDE SEWER CONNECTION TO SEWER MAIN SHALL
GC
GENERAL -CIVIL
PL
PROPERTY LINE OR PLACE
TOP
TOP OF PIPE
BE ALLOWED ONLY IF APPROVED BY THE ENGINEER.
CE
CONSTRUCTION EASEMENT
TP
TELEPHONE POLE OR
CF
CUBIC FOOT (FEET)
CIP
GALVANIZED IRON PIPE
POC
POINT ON CURVE
TELEGRAPH POLE
15. CONTRACTOR SHALL RE- POSITION SIDE SEWER ALIGNMENT, IF NECESSARY, TO AVOID DISRUPTION
GPD
GALLONS PER DAY
POT
POINT ON TANGENT
TYP
TYPICAL
OF EXISTING UTILITY SERVICES TO PROPERTY OWNER.
CFH
CUBIC FEET PER HOUR
GPH
GALLONS PER HOUR
PP
POWER POLE
16. NO SIDE SEWER SHALL BE CONNECTED TO THE NEW SEWER MAIN PRIOR TO TESTING
CFM
CFS
CUBIC FEET PER .MINUTE
CUBIC FEET PER SECOND
GPM
GALLONS PER MINUTE
PRESS
PRESSURE
UG
UNDERGROUND
AND FINAL ACCEPTANCE OF MAIN, UNLESS APPROVED BY THE ENGINEER.
CIP
CAST IRON PIPE
GIRD
GRADE OR GROUND
PSF
POUNDS PER SQUARE FOOT
UGC
UNDERGROUND CONDUIT
17. TV INSPECTION OF EXISTING SEWER MAINS SHOW SOME RESIDENTIAL LOTS CONTAINING
SEVERAL SIDE SEWER LATERALS. THE CONTRACTOR SHALL DETERMINE PRIOR TO INSTALLATION
GV
GATE VALVE
PSI
POUNDS PER SQUARE INCH
UGE
UNDERGROUND ELECTRIC
OF NEW SEWER MAIN WHICH SIDE SEWER IS ACTIVE IN ORDER I'D LOCATE NEW SIDE SEWER
CL
CENTER LINE OR CLASS
PT
POINT OF TANGENCY OR POINT
UGT
UNDERGROUND TELEPHONE
CONNECTION TO SEWER MAIN. INACTIVE AND ABANDONED SIDE SEWERS SHALL BE PLUGGED.
CMP
CORRUGATED METAL PIPE
HAP
HORIZONTAL ANGLE POINT
PVC
POLYVINYL CHLORIDE
USGS
UNITED STATES GEOLOGICAL
CID
CLEANOUT
HORIZ
HORIZONTAL
PVMT
PAVEMENT
SURVEY
COB
CLEANOUT BOX
HPI
HORIZONTAL POINT OF
PWR
POWER
COL
COLUMN
INTERSECTION
VAR
VARIABLE
CONC CONCRETE
CTR CENTER
HWY HIGHWAY
HYD HYDRANT
OTY QUANTITY
VC VERTICAL CURVE
VCP VITRIFIED CLAY PIPE
CY
CUBIC YARDS
ID
INSIDE DIAMETER
R
RADIUS
VERT
VERTICAL
CLR
CLEAR
IN
INCH
RC
REINFORCED CONCRETE
VOL
VOLUME
COORD
COORDINATE
IE
INVERT ELEVATION
RCP
REINFORCED CONCRETE PIPE
CONT
CONTINUOUS
I
INSTALLATION OR INSTALL
RD
RED
ROAD
REDUCER OR REDUCING
WM
W
WATER METER / WATER MAIN
WEST OR WATER
COMPT
COMPACT OR COMPACTION
INV
INV
INVERT
WITH
CONST
CONSTRUCTION OR CONSTRUCT
IPS
IRON PIPE SIZE
REF
REFERENCE OR REFER
W/
CTRL
CONTROL
REINF
REINFORCING OR REINFORCED
WT
WEIGHT
L
LENGTH
REOD
REQUIRED
WWM
WELDED WIRE MESH
DET
DETAIL
LAT
LATERAL
RP
RADIUS POINT
W/O
WITHOUT
DI
DUCTILE IRON
LC
LENGTH OF CURVE
RT
RIGHT
WV
WATER VALVE
DIA
DIAMETER
LF
LINEAL FOOT (FEET)
R/W
RIGHT OF WAY
W LAT
WATER LATERAL
DIP
DIST
DUCTILE IRON PIPE
DISTANCE
LP
LIGHT POLE
WWp
WASTEWATER PROJECT
ON
DOWN
LN
LONG
YD
YARD
DWG
DRAWING
SECTION AND DETAIL IDENTIFICATION
SECTION IDENTIFICATION
NOTE DETAIL IDENTIFICATION
M SECTION CUT SHOWN ON DRAWING
G AS:,,,,,—
SECTION NUMBER
DETAIL LETTER - -�„
DRAWING
ON WHICH
DETAIL APPEARS
2
SHEET NUMBER ON WHICH
G -2
THE DRAWING IS
LOCATEDTION
DETAIL IDENTIFICATION
(2) ON SHEET NUMBER G -2 THIS SECTION IDENTIFIED AS:
(1) DETAIL IDENTIFICATION SHOWN ON DRAWING G-1 AS:
q
`—DETAIL LETTER
SECTION NUMBER
G -2
��SHEET NUMBER ON WHICH
SECTION NAME q
THE DETAIL IS LOCATED
G-I
SHEET NUMBER ON
WHICH THE SECTION
(2) ON SHEET NUMBER G -2 THIS DETAIL IDENTIFIED AS:
-
IDENTIFIACTION IS SHOWN
DETAIL LETTER
� 9����
"�
WARNING
0 %z
DETAIL NAME q
! __
R. C.E. NO. OAT
1
'I
I�
G -I
SHEET NUMBER ON
������
Z4 4
IF THIS BAR DOES
NOT MEASURE
WHICH THE DETAIL
:(-il $1.4 r 43
RY R. C. E. NO. DATE
RS, INC.
I•
THEN DRAWING IS
NOT TO SCALE.
IDENTIFIACTION IS SHOWN
CITY OF RENTON
WAs611 DEPARTMENT OF PUBLIC WORKS
HIGHLAND SEWER REPLACEMENT
f W W P- 13 -0488 ABBREVIATIONS. SYMBOLS AND
a �0 Rp° eo ��� GENERAL NOTES STS ess TL1
AL CMG` DESIGNED: C DATE: 3/93 FILE NAME:
DRAWN: CPA
EXPIRES : 12/13/ X60W D140WINA 45 Q(>ILT VCiO JECi ;L/joffC_f_9_jy C
N0. HECKED: SCALE: NONE FIELD BOON: PAFGE:
REVISION BY APPR. DATE SHEET: G -2 OF:
A I r I I I I AL I Alik _ I z I ][ I I I t I I I iY i I i