Loading...
HomeMy WebLinkAboutD-200409ENERGY DISSIPATOR a OUTLET STRUCTURE PLAN 160 y — r-A.P STA.7 + 53 8 %60 11ON_ENERGY DISSIPATOR —/ f' i NOTES- 1 TEMPORARY DIVERSION & SITE - CLEARING _ INCLUDING.- DEBRIS HAULING _ -- -SHALL BE- P_RO.VIDED- AT- :NO. EXTRA -COST. - 2 :G.R-UU.T- IIC.SIDE.WACLS &- PAD —OF — 3RIMARY CELL -OF- ENERGY - DISSIPATOR - -- IGABION ENERGY DISSIPATOR SUMMARY OF QUANTITIES CODE DIMENSION NO. OF UNIT A 6'. 3'. 3' 2 B 9"x3'x3, 13 C 12x3x3 15 E 9'x3'x1.5' 4 F 12'x 3'x 1.5' 2 G 6x3 xl 14 R 12`x6'x0.5' 14 MJM APPROVED: / /&0 SEC. 6,T.22N., R.5E., W.M. IMPERVIOUS LININGS POLYESTER REINFORCED HYPALON 45 MIL. GABION - ENERGY _- DISSIPATOR & OUTLET DETAILS QUANTITY TABULATION 1. STRUCTURE EXCAVATION -GLASS E5 2. IMPERVIOUS LINING MATERIAL 3. GABION CRIBBING 4. Z8 H.D.P.E. -SDR26 EXPANSION SLEEVE 5. 14 H.D.P.E. -SDR32 EXPANSION SLEEVE 6. EXPANSION SLEEVE - FASTENER 28 DIA. 7. .EXPANSION: -- :SLEEVE.._ FASTENER 14 DIA 24- H.D.P.E - -SDR26 3/8.THICKx9 WIDE x 5'LONG STEEL-W.ELDED TO RING.USE 3° LONG STEEL WELDED FOR 12 "DIAM. RING. REMOVE NATIVE MATERIAL AND PLACE AT FRONT OF GABION ENERGY DISSIPATOR FOR LOW FLOW(TYP) q CONSTRUCTION BASE LINE (SURVEY LINE ) 5'I EL. 171.50 24 170 EL.- 167.0 165 - - - - -- -- --- - - -- I.E. 162.0_ EXPANSION SLEEVE O 1160 6 THICK GABION MAT I MPERVI.00S::::LEN]VG- OLYESTER SECTION A -A REINFORCED_HYPALON - 45.- MIL. _(TYP.) I3 I 18 I 3 EL. 161.0 - SECTION B -B 3 IB 3 5:I EL. 168.50 165 EL.= 162.50 ' -- -- - - -- -- -- -- - -- �— EL. 161.0 160 —3 /;THICK- 3'WIDE GALVANIZED SECTION C -C STEEL BAND 1%8 HOLE W/ I DIA. GALVANIZED \ 3 L 18 T L BOLT AND WASHER 2 SETS / RING f EL. 167.0 EL.= 165.0 5:1 165 -* 28'. FOR -28" EXPANSION - SLEEVE I ------ 0 _ 14' FOR 14 EXPANSION SLEEVE I - EL. 161.0 12° FOR 12" EXPANSION SLEEVE 160 L SCALE 1 :10 SECTION D -D • FILL BOTH SIDES OF GABION ENERGY DISSIPATOR EXPANSION SLEEVE FASTENER DETAILS WALLS WITH NATIVE MATERIAL SCALE 1 = 5 150 C.Y. 85 SQ.YD. 146 C.Y. 10 L. F. 10 L. F. -2 - FA. 2 -EA-. 20002000 - 93(9 DM2004 DATE REVISION BY CITY OF RENTON 1, DEPARTMENT OF PUBLIC WORKS " °o?• NORTH FORK SPRINGBROOK CREEK __ - REGIONAL BYPASS PIPELINE s'o sF s,,. <v, FF ASTER Eo c ss /ONAL E`G DRAINAGE DETAILS DESIGNED TUKUDOM DATE JUNE 1992 FILE 10. 047032 MODIFIED ENERGY DISSIPATOR /ADDED 12�� H. D.P. E. W/ MJM APPROVED: DRAWN MERCIER SCALE AS SHOWN 87 -I 3 FIELD BOOK �_ LARRY GIBBONS, P.E. CHECKED CHIN PAGE NO. CL -10 CONTROL SLIDE GATE RECOMMENDED: DOUG CHIN KING COUNTY APPROVED DIRECTOR OF PUBLIC WORKS SHEET OF I2 REVISION BY 20002000 - 93(9