HomeMy WebLinkAboutD-201401NEW MH a NEW ELEC. VAULT SEE SHEET C8 MODIFY EXIST. GATES SO THEY SWING IN-T EROSION CONTROL NOTES I. SEE CID FOR GENERAL NOTES A 2. PROVIDE SILT FENCE AT EXISTING FENCE LOCATION PER Ca CIO 3. PROVIDE INTERIM STORM DRAINAGE EQUIPMENT TO BE RELOCATED PROTECTION PER DETAILS TO OLD SUBSTATION 2 SEE SHT C5 AT ALL STRUCTURES WITHIN Ca CID Ca c10 100' OF CONSTRUCTION 4. EXISTING GRAVEL MAY BE USED FOR CONSTRUCTION ENTRANCE Ca CIO — NEW AL ` )----- - - - - -- T 21 SEE SHT C8T ASPHALT, TYP. NEW CB _/ G.,_ R EARTH COLUMN NORTH i EXISTING EXIStING _ / GALLERY GALLERY TO REMAIN TO BE REMOVED / c BANK 4 BANK A SWITCHGEAR G mR REMOVE EXIST DUCT BANK BETWEEN NEW 0 �1 ELEC VAULL AND GALLERY. 100 22 NEW CMU _ _ _ 21 < SLS� NEW DUCT AFTER 'IN REPLACE WITH WALL SEE 6 t/ E REPLACE SHT C9 3 3 STOCKPILE COPPER SEE SHT C6 FOR DETAILS — — f r NOT PROJECT ENGINEER TO LOCATION . j G'DIRECj p `CUT U BANK "B SWITCHGEAR ttt L TO DgMgGE EOUIPMENL RCISE CARE LINE 10 - NEW / �' _. - 10 _.. _ -= Ci = __ -B o __ ABANDON EXIST 36' ',578 (SD) y I -' �""' - 36" RCP STORM SE o O ° SEE SHT C8 -- Y � Tr_ T I -- - -- 14 21 LEGEND 6 '411 y�Gji; s / SYMBOLS DESCRIPTION ` T L 6 DUCT BANK TO 10-58 BLDG - - - G GROUND WIRE >. #6 22 LL TO REMAIN (DO NOT DISTURB) EXISTING EXOTHERMIC WELD. X10 P P/ • NEW EXOTHERMIC WELD R,' 21 SPARE EXIST I4 o EXISTING GROUND ROD (3/4" X ID ) T TRANSFORMER CUT LINE. SEE C5A FOR RELOCATION e5 o EXISTING. FENCE POST 2 13�� / Io o 0 o EXISTING FENCE POST 000 a 0ooa a'. 1 �T- DETAI L 'R T T T [CG 49... __..`l. REFERENCE DESCRIPTION - .- Ut A CONNECTION TO STEEL COLUMNS T B CONNECTION TO STEEL COLUMNS AND 21 / EXIST FENCE LIGHTING ARRESTER 23 G•. - -/ /. TOREMAIN- C TRANSFORMER CONNECTION EXISTING EXIST. GATE / EXIST GATE .SECURITY FENCE TOREMAIN .;�. TO REMAIN D SWITCHGEAR CONNECTION TO REMAIN. - CONSTRUCTION I E FENCE DETAIL ENTRANCE SEE..ca CIO P FENCE CONNECTION p. PP SPECIAL FENCE CONNECTION DEMOL I TI.ON PLAN — SUBSTATION I R GROUND ROD CONNECTION 1" - 10 -0' T TEE CONNECTION X CROSS CONNECTION S CABLE .TO STRUCTURE '. RECOMMENDED FOR APPROVAL BY'D a �I,yq�yrffm N-3-a1 s— ioKMWAT6R rjKL-Y COLUMN7 EXIST. FENCE TO REMAIN R P ash \J 22 \\ G T REMOVE FENCE TO PROVIDE ` EX�SIN SDI FOR 20' SLIDING GATE S 48�5� (,50 R p SEE SHT C9 �W S C6 21 SEE J 4 RCP Si OP �E� STORM SEWER MANHOLE / CUT J I LINE R - g 21 ---- -IF i T SEE SHT C8 FO �p RELOCATION PL EXIST FENCE TO REMAIN aE 2 SSS 0y y Cort}S'i'RUdeJ --A. A5- $Legit Available, �mm�= CITY' OF RENTON DEPARTMENT OF PUBLIC WORKS SUBSTATION 1 - DEMOLITION PLAN RENTON 115 KV CONVERSION p T.ROSLING .— 03.01.91 1 — L.V%LWRMV5E 8.0UNLAP 011101114 V 00.22.8 1/12.20 D E M O L I T I O N N O T E S No, D E S C R I P T 1 0 N STOCKPILE TO LOCATION AS DIRECTED BY PROJECT ENGINEER EXERCISE O CARE NOT TO DAMAGE EXISTING STEEL STRUCTURE, FUSES, DISCONNECT SWITCHES, BREAKERS, INSULATORS, WIRE, AND MISCELLANEOUS HARDWARE STOCKPILE TO LOCATION AS DIRECTED BY PROJECT ENGINEER, EXERCISE O CARE NOT TO DAMAGE EXISTING TRANSFORMERS, ASSOCIATED WIRING AND INSULATORS STOCKPILE TO LOCATION AS DIRECTED BY PROJECT ENGINEER, EXERCISE 0 CARE NOT TO DAMAGE EXISTING SWITCHGEAR AND ASSOCIATED CABINETS, 3 WIRING AND HARDWARE PULL WIRES AND ABANDON CONDUIT 18 INCHES BELOW GRADE. PLUG CONDUIT WITH 12" NON - SHRINK GROUT. © REMOVE AND DISPOSE OF CONCRETE FOUNDATION 10 BACKFILL IN 8 LIFTS WITH STRUCTURAL FILL TO 95% COMPACTION PER ASTM D1557. 13 ABANDON EXISTING STORM SEWER PIPE IN PLACE, PLUG EXPOSED PIPE SECTIONS W1 NON- SHRINK GROUT, REMOVE AND DISPOSE OF EXISTING STORM SEWER LINE, PLUG REMAINING 14 PIPE W/ NON- SHRINK GROUT.. I5 REMOVE AND DISPOSE OF EXISTING STORM MANHOLE. RELOCATE EXISTING CAST IRON FRAME 3 GRATE, GRID GROUND SYSTEM TO REMAIN. WHERE NECESSARY TO CUT GROUND STRAP 21 FOR REMOVAL OF FOUNDATIONS OR EQUIPMENT, RECONNECT WITH APPROVED EXOTHERMIC WELDING TO MAINTAIN CONTINUITY OF GROUND SYSTEM, 22 MAINTAIN EXISTING LIGHT STANDARDS, FOUNDATION, AND GROUNDING SYSTEM: 23 SEPARATE'AND ELECTRICALLY ISOLATE SUBSTATION FENCE FROM THE REST OF THE FENCING. SEE DWG. 11.0 -109 -2100 E9. Cort}S'i'RUdeJ --A. A5- $Legit Available, �mm�= CITY' OF RENTON DEPARTMENT OF PUBLIC WORKS SUBSTATION 1 - DEMOLITION PLAN RENTON 115 KV CONVERSION p T.ROSLING .— 03.01.91 1 — L.V%LWRMV5E 8.0UNLAP 011101114 V 00.22.8 1/12.20