Loading...
HomeMy WebLinkAboutD-207001N184,200 4 \I 1 \ \ � 1 CB O Z Z m a REMOVE ALL PRODUCT, STEAM. p DRAIN, AND CONDENSATE LINES INSIDE DIKE CONTAINMENT WALLS, CAP LINES AT WALLS DR; WHERE NOT REMOVED OUTSIDE DEBEl TAC1K CONTAINMENT. 0 BLDG 4 -89 (STEAM PLANT) PRODUCT. STEAM, AND CONDENSATE LINES Z TO BE ABANDONED AND PLUGGED. O N184,10� \F " +� Imo + CLEAN AND REMOVE STEEL TANK 4(\ ARE -129 OCT Lzz o. SEE NOTE 7 Yl� N 186075.958 1 E 1660356 .71 718 \` � BM 54 tip m^�l Gft V ELEV =23 62 ry4 CB \ N \ TOP 2222 A P INV SW 20.82 CA REMOVE EXISTING y M° 50 \ 3 REMOVE 2-1/2"0 FIRE GAS SUMP AND VALVE � \2 D ASPHALT BOX LINE FROM THIS B S CB 2 11 6 SD POINT TO THE TANK TOP 2101 Ay INV W 2016 19.9 \ v> o INV 5 19 96 \ BLOW DOWN SUMP DIKE CONTAINMENT HOT CONDENSATE WATER v\, AREA WALLS NEW ASPHALT N FUEL TANKS PLAN - DEMOLITION ' RETE \ ro> REMOVED CONIC m \ ASPHALT Z 2' UTILIDOR r n * m HOSE PLATFORM y r 11 WJGR I f ` F m 1 CONCRETE 4Jy C04 PAD v. SLOG 4 -89 xp es pftPlN as > \.. p1E5EL TPNK o CO \ e \N 2.. WV. HW ry> NN I CATHODIC N 1843918.204 8 FUEL PORT N CABLE E 1650436.2f9 HATCH I BM 53 DIKE CONTAINMENT ELEV 2476 AREA WALLS CLEAN AND REMOVE STEEL TANK `\ TANK TOP El = EL= 526 NGP ARE -129 PIV N183.900 } _ M1> W / } >r sQ + WV / mNr 6 Hx� ro� GRAVEL QCs x a x' ' PI% xi ' CONCRETE A CONTAINMENT WALL �xi SECTION �x � NOT TO SCALE Ci Ci "994 '. CONCRETE GONEREO WPLKx i PLAN EXISTING CONDITIONS AS PpL J. UH w SYM REVISION BY PPRDVE DATE SYM REVISION BY PPRDVE DATE ACCEPTABILITY REVISIONS PER BOEING REVIEW COMMENTS OF ❑ AUBURN, WA 98002 E fI� THIS DESIGN AND /OR 01 JUN 9 A HA R WS R FINAL REVIEW JD /JH MJB 04 JUN ❑ EVERETT, WA. 98201 �(l i:,�, PEC IFICATION IS APPROVI o � ❑ KENT, WA. 98031 an° r��aUV� El PORTLAND, OR. 97226 �O .APPROVED BY IllT..jj DAT ■ RENTON, WA. 98055 2Z'1,NAL.ENo FACILITIES DEPARTMENT ',Y ❑ SEATTLE, WA. 98124 Etrwes a /I-- -� D A REMOVE AND SEGREGATE ALL OILED SAND (3 THICKNESS ANTICIPATED) OVER LINER /r REMOVE FILL ABOVE LINER / INSIDE DIKE CONTAINMENT NOTES 1. UNDERGROUND UTILITIES SHOWN HAVE BEEN PLOTTED FROM A COMBINATION OF FIELD - LOCATED SURFACE FEATURES AND RECORD DATA AS FOUND ON SCHEMATIC DRAWINGS. OTHER UTILITIES, NOT SHOWN, MAY ALSO BE PRESENT. CONTRACTOR SHALL VERIFY LOCATIONS BEFORE DIGGING, PROTECT EXISTING UTILITIES AND REPAIR ANY DAMAGES. 2, CUTS' DF CONTAINMENT WAIL, TRIPLE RINSE PRODUCT LINES, AND THEN REMOVE OR GROUT AND ABANDON IN PLACE. 3. DISPOSITION OF DEMOLITION MATERIALS AND NON- HAZARDOUS WASTE SHALL BE APPROVED BY THE OWNER. 4. A COPY OF THE PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 5. CONTRACTOR TO SAVE AND REINSTALL EXISTING SUCTION HEATER AND FOAM MAKER ON NEW TANK. _ 6. SOURCE OF BASE MAP IS FROM P SURVEY CONDUCTED BY PERMIT ENGINEERING, INC. UTILITY LOCATING WAS PERFORMED BY LOCATING INC. 7. CONTRACTOR MAY BREACH EXISTING CONTAINMENT. WALL TO PROVIDE CONSTRUCTION ACCESS FOR INSTALLATION OF UTILIDOR - ONLY. OTHER BREACHES IN CONCRETE CONTAINMENT DIKE SHALL BE MADE ONLY UPON WRITTEN APPROVAL OF OWNER'S REPRESENTATIVE. SAWCUT ENDS OF REMAINING WALLS TO PROVIDE SMOOTH VERTICAL SURFACES AND REMOVE ALL DEBRIS. CONTAINMENT WALL RESTORATION NOT REQUIRED. 8. SOURCE OF INFORMATION ON EXISTING DIKE CONTAINMENT WALLS AND TANK ARE TAKEN FROM EXISTING BOEING DRAWINGS. (250,000. GALLON FUEL OIL STORAGE FACILITY - RENTON, 1973) REMOVE LINER INSIDE w DIKE CONTAINMENT Hi�Quv �J.yq,�OG�P Ca�r> n,�.tPo. No D4070 N RECOMMENDED ` 4FAR OVA 0 20 40 BAfY SCALE. IN FEET RECOMMENDED s FOR APPROVAL Y BY �a VGr.Y HARKNOVISM ?44,V R&V /SW 10-23'92 AW DA TT E 93 SUBILE LRSi REVISION SYM DATE CJC EXISTING CONDITIONS AND DEMOLITION PLAN TITLE FUEL .STORAGE REPLACEMENT FOR ARE -129 RENTON FACILITY BLDG 4 -89 RENTON CyDF 6 J, C,NE. 305355 FU - ➢OMPWGk D. 304 - 089 -1002