Loading...
HomeMy WebLinkAboutD-20700330'0 NEW DOUBLE -WALL STEEL TANK TO RE ERECTED ON SAME CENTER POINT AS REMOVED TANK CB SEE NOTE 8 A SEE NOTE 7 ME// 2' - I o X SEE I S \ NOTE 5 x CB � I DIESEL TANK PLUG AND SEAL `ST CAST NE - IRO EXISTING 4 "0 DRAIN i STORM LI � LINE. SEE NOTE CAST IRON STORM LINE / `SAW CUT CONCRETE AS REQ'D DRKN TO INSTALL STORM LINE. CONCRETE FUELING PAD AND DN STORM LINE FUEL CONTAINMENT AREA 8 "0 CAST IRON STORM LINE 8 "0 CAST IRON STORM LINE ❑ VALVE BOX • 6'0 SHUT -OFF VALVE NEW CURB—/ CB UTILITY VAULT 3030 -LA I�60 . OR APPROVED EQUAL - EW CURB 15' �'i 0 EL 25.7 FEET - - HOSE • 6 "0 GATE VALVE CAP AND SEAL PLATFORM v • PLUG AND SEAL `ST CAST NE - IRO EXISTING 4 "0 DRAIN i STORM LI � LINE. SEE NOTE CAST IRON STORM LINE / `SAW CUT CONCRETE AS REQ'D DRKN TO INSTALL STORM LINE. CONCRETE FUELING PAD AND DN STORM LINE FUEL CONTAINMENT AREA 8 "0 CAST IRON STORM LINE 8 "0 CAST IRON STORM LINE ❑ REVISION SEE NOTE 2 16.0 140 PROFILE - STORM DRAIN AND CATCH BASINS �F� C3 C3 REVISION, ❑ AUBURN, WA, 98002 ❑ EVERETT, WA. 98201 El KENT WA. 9031 Cl PORTLAND, DR. 98220 ® RENTON, WA. 98055 FACILITIES DEPARTMENT ❑ SEATTLE, WA. 98124 NEW RAMP SEE DETAIL L ON DRAWING C5 K C3 CS M. k- 11' 2" ICB NEW CURB—/ CB j I�60 TO EL. 25.7 FEET 15' 15' �'i x 1 BM 53T SEE NOTE 3 x F C3 C3 CONTRACTOR SHALL EXPOSE AND VERIFY GRADE x O BLACK STEEL LINE / C O AND CONDITION OF EXISTING UTILIDOR. CONTRACTOR TO DESIGN CONNECTION BETWEEN NEW AND EXISTING , UTILIOORS AND SUBMIT TO OWNER FOR APPROVAL x NEW CONDENSATE PRIOR TOCONSTRUCTION... COOLER NEW CONCRETE x 0 2 "m BLACK STEEL DQ N>_ x N 0 10 20 SCALE IN FEET E %ISTING CONCRETE UTILIDOR BLDG 4 -89 STEAM PLANT- _ UTILITY PLAN - _ SCALE 1" -10'. 1 260 METAL FRAME AND GRATE STD PLAN B -2 OF WSOOT. (TYP.) i 24'. OF 6'0 CAST IRON STORM LINE CATCH BASIN TYPE I 24.0 MEETING STD. PLAN B -1 OF WSOOT. (TYP.) 30 x34 "x60 "H MAX.) 22.0 0 70' OF 8'0 _ SLOPE 0.008 CAST IRON. STORM .LINE O SLOPE = 0.005 20.0 CATCH BASIN -TYPE I CATCH BASIN - TYPE TOP EL. 23.9 TOP EL. 23.9. CATCH BASIN - TYPE I. 6" INV. N 21.04 8" INV. N 20.87 18.0 .BOTTOM 20.0± IN 6" V. S 20.69 - TOP EL. 24.7 SEE NOTE 2 6" INV. W 20.90 BOTTOM EL. 19.9*- 8° INV. W20.52 8" INV. S 20.54 SEE NOTE 2 - BOTTOM 19:5± REVISION SEE NOTE 2 16.0 140 PROFILE - STORM DRAIN AND CATCH BASINS �F� C3 C3 REVISION, ❑ AUBURN, WA, 98002 ❑ EVERETT, WA. 98201 El KENT WA. 9031 Cl PORTLAND, DR. 98220 ® RENTON, WA. 98055 FACILITIES DEPARTMENT ❑ SEATTLE, WA. 98124 NEW RAMP SEE DETAIL L ON DRAWING C5 K C3 CS M. k- 11' 2" 12" SQUARE COVERS 24" SQUARE COVER PLAN - OIL /WATER SEPARATOR -(9) C3 "H NOTES: 1. OIL /WATER SEPARATOR SHALL BE PIPE INC. MODEL NO. 5106 -5 MODIFIED OR APRROVED EQUAL. SECTION - OIL /WATER SEPARATOR (b C3 C3 NOTES: L GROUNDWATER AT THIS SITE FLUCTUATES BETWEEN ELEVATION 19 AND 17 FEET. CONTRACTOR MAY HAVE TO DEWATER SOME EXCAVATIONS DURING. CONSTRUCTION. 2. FINISHED GRADE OF CATCH BASINS AND INLETS SHALL BE ADJUSTED TO POSITIVELY DRAIN THE PAVEMENT AREAS. 3, BENCHMARK 53, TOP OF ASPHALT SURFACE AT SOUTHEAST CORNER OF PROJECT SITE. EL. = 24.76 FEET. 1� 4. INSTALL NEW 6" DRAIN WITH REMOVABLE GRATING IN CONCRETE FUEL CONTAINMENT AREA, DRAIN TO COMPLY WITH STD. PLAN 8 -4 OF WSOOT, OR APPROVED EQUAL. 5. PLACE AND COMPACT HOT ASPHALTIC CONCRETE IN THIS AREA TO FACILITATE DRAINAGE OF STORM WATER RUNOFF TO CATCH BASIN. 1� 6. ALL CAST IRON PIPE STORM LINES SHALL HAVE MINIMUM WALL THICKNESS PER A.W.W.A. CLASS 22, 7. REMOVED PORTION OF CONCRETE DIKE CONTAINMENT WALL SHALL NOT BE RECONSTRUCTED AT CONCLUSION OF PROJECT. V 8. SLOPE GROUND SURFACE INSIDE EXISTING CONTAINMET TO DRAIN AT 19 TYPICAL TOWARDS CATCH BASIN. NEW CATCH BASIN ELEVATION 23.6 FEET, PIPE INVERT ELEVATION 21.05 FEET, BOTTOM OF CATCH BASIN AT 20.0 FEET. Ce.�s lvz+cir°d- N Lir -� ./� �va• /�� RECOMMENDED FOR APPROVAL BY D -2070 •2Cwc� wA'/�'R RECOMMENDED � FOR APPROVAL BY /7a—_ H&RTOWRIM PL,+� Ravin /a -z3 -9Z 5/19/92 1BILITY DRAWN Y DATE SUBTITLE r LAST REVISION I SYM I DATE N AND/BR CHECKED "C '/7 9s UTILITY PLAN AND DETAILS SHEET IS APPROVED JAH 5 ] 92 /1 OF 3 DEPT, DATE JAH 5/7/92 TITLE CHECKED FUEL STORAGE REPLACEMENT APPROVED SLG s T ez FOR ARE Loe ND. 305355 FUPDWG# RENTON FACILITY DWG, NO, APPROVED BLDG 4 -89 RENTON 304- 089 -1002