HomeMy WebLinkAboutD-20700428
28
al
BLDG BLDG 4 -89
26
E1
EL 25.1
26
4' -11"
NOTES:
EST FLOOR E! 25.5
CONTINUOUS 1/4'x2" GALVANIZED
EST EL 24.5
STEEL
1. T POSSIBLE, CONSTRUCT STEAM AND FUEL PIPING TO EXIT VAULT AT
THIS LOCATION IN ORDER TO AVOID CUTTING VAULT LID. IF NECESSARY
ADD VA RISER OBTAIN THE NECESSARY HEIGHT TO ALLOW PIPING
TO EXIT THE SIDE WALL OF THE VAULT INSTEAD OF THE LID /COVER.
WALL
zo 29
EST SUMP EL 23.0
24
_ •.
-
EXISTING UTILIDOR
-
<
a
2. PROTECT STORM DRAIN LINE BY PLACING AT LEAST 3 INCHES OF
STYROFOAM OVER THE PIPE PRIOR TO INSTALLING THE UTILIDOR
V
SECTION. CONTRACTOR TO TAKE THE NECESSARY PRECAUTIONS TO
w
-_ _ - - - -
--
AVOID DAMAGE TO THE 6 INCH DIAMETER CAST IRON PIPE.
- -_
3, THE EX CT ELEVATION THE EXISTING' UTIUDOR, AT THE POINT WHERE
22
22
- •
THE NEW UTILIDOR IS TO BE CONSTRUCTED, IS UNKNOWN. CONTRACTOR
TO MATCH THE NEW UTILIDOR FLOOR ELEVATION TO THE FLOOR
ELEVATION OF THE EXISTING UTILIDOR IF THAT ELEVATION IS GREATER
EST EL 22.0
_
THAN 22.0. OTHERWISE ADJUST SEWER PIPE AND UTILIDOR GRADES AND
SUBMIT TO OWNER'S REPRESENTATIVE FOR REVIEW AND APPROVAL PRIOR
TO CONSTRUCTION.
20
20
2 "x2 "x1/4" L GALVANIZED STEEL
AT TOP OF WALL WITH 1/4'0x4"
'
STUDS ® 12" O.C.
PROFILE
- UTILIDOR
NOT TO SCALE
G2 G4
SECTION — UTILIDOR K—D�
.
NOT TO SCALE C2 C4
i� NOTE: UTILIDOR SHALL BE UTILITY VAULT CO. MODEL NO. 5588 TRENCH
WITH COVER NO 558T, OR APPROVED EQUAL, VAULT AND COVER TO
UI
BE FABRICATED TO WITHSTAND AASHO HS 20 LOADING STANDARDS.
26
26
BE 242
I
EL 245
I
24
24
-
SEE NOTE 3
F
6
NEW UTILIDOR
>.
- - - - - - - - - - - - - - - - - - -
22
—21.5
q. -0..
NEW VAULT
El. 21.7 —20.9
EL 22.0
EL 25.6
/EL
5.1
20
20
6.0 CAST IRON
STORM DRAIN
SEENOTE 2
EL 24.0
SEE NOTE 1
EL 24.1
S' -5'
NEW UTILIDOR
PROFILE
— UTILIDOR
'\
NOT TO SCALE
C2 C4
\��\��
•.•
EL .25.6
�I
' 26
'.
NEW VAULT
26
EL 242
\ \e \\
EL 24.0
EL 24.1
EL 21.6
24
GROUND SURFACE
24
SAWC FABRICATE OPENING
NEW UTILIDOR
-
INTO VAULT . VAULT OUTSIDE
z
DIMENSIONS: 6' -0" L x 4' -0 "W
zz 22
--
_ - -_ - --
22
-_.
."
CAUL O..TO. SEAL, TAR JOINT AND
w
EL 21.6 EL 21.7
EL 19.6
20
20
RECOMMENDED
FOR APPROVAL
EL 19.6
SECTION — VAULT rE
By
1B
18
NOT TO SCALE cz c4
RECOMMENDED
FOR APPROVAL
�. L MODEL NO. 660 -L WITH
NOTE VAULT SHALL BE UTILITY VAULT CO.
PROFILE — UTILIDOR AND VAULT > i
COVER No. 64 -366D, OR APPROVED EQUAL
BY '��• �`
;PA� v/A i✓
,c -z9 -92
NOT TO SCALE
',. C2 C4
Con bwd,'.' M. 4—R-11 /va,''Wl,-
D-zV749
/uI�-s�w��
ItW1IVIY
Ws
5/19/92
REVISION
BY
PPROVE
DgTE
SYM
REVISION
BY
PPROVE
DATE
`
`:
ACCEPTABILITY
DRAWN BY DATE
EJC
5/ / 92
SUBTITLE
LAST REVISION
SYM
DATE
5 PER BOEIN REVIEW COMMENTS OF
JD /JH
MJB.
4JUN92
❑ADBURN,
- D EVERETT,
WA. 98()()2
WA. 98201
�}j'( /�
',�V'
THIS DESIGN AND /OR
PECIF [CATION IS APPROVED
JAH
S T 92
UTILIDOR AND VAULT
SHEET
4
AN FAR R FINAL REVIEW
p D KENT,
WA. 98031
�'r
ziali�
N N
--
TITLE
4
OF
•
���0� O PORTLAND,
OR. 97280
�02,`�_�57m
APPROVED BY
WEPT.
ATE
NECKED
JAH
s 9z
FUEL STORAGE REPLACEMENT
5
■ RENTON,
WA. 98055
SLG
57 92
FOR ARE -129
DEB NO.
COMP NO.
FACILITIES DEPARTMENT D SEATTLE,
WA. 98124
"0"
IXPIB'.S
v
RENTON FACILITY
305355
uwc. No.
FU -DWGq
1 -30-2070
- —
APPROVED
BLDG 4 -89 RENTON
304 -089
-1002 /�� -