Loading...
HomeMy WebLinkAboutD-269033�I v / / v v END OF EXIST 1 NG REMOVE EXISTING BOX CULV EDT RETAINING WALL PROP05EO DETAINING WALL UNREI NFOKCEO 31_0, 4' -11" / CONCRETE 5EAL W / // EX15T I NG PZ -27 CLASS 4000W / / SHEET PILE . / TO REMAIN - -- ------ - --- -- --- --� - -- 47 p � j . 7 Fr ° EXISTING , RETAINING _ WALL STEM REMOVE EXISTING SHEET PILES TO EL. 6.40 - - - - - -- `---------------- - - - - -J � EXIST I NG RETAINING WALL FOOTING \ TO REMAIN EXIST 1 NG 24110 ABUTMENT PI LE5 a FILE NAME TIME DATE PLOTTED BY DESIGNED BY ENTERED BY CHECKED BY PROD. ENGR. REGIONAL ADM. WALL CONTROL LINE REMOVE EXISTING BOX CULVERT -, 4, -0„ 100 YR. FLOOD CLR. 1 - -EL. 17.30 77 - -� i � I LIGHT ' LOOSE RIPRAP 2 REL ELEV. 0.00 41-1011 EXISTING 5HEET PILE WALL TO REMAIN i► C ftWorkiProjectV 3:14:33 PM 8/19/2010 dlo J. MENARD D. TELLERS R. BHARIL L.HODGSON D. DYE PLAN TOP OF RETAINING WALL M ASHLAR STONE FIN13H W/ PIGMENTED SEALER COLOR "MT. ST. HELENS" ELEV. 17.50 CV N 10:1 PLACE TWO LAYE95 , 15 L5. TAR PAPER FOR BOND BREAKER IF CAST AGAI N5T SHEET. PILING * 5EE NOTE - v v v a / REMOVE EX15T1NG BOX CULVERTS END OF EXISTING RETAINING WALL PROPOSED RETAINING WALL —UNREINFORCEO EXISTING PZ -27 4' -11" 3' -011 CONCRETE 5EAL SHEET PILE / CLA53 400OW a TO REMAIN -7- _7 -- r a EXISTING ' RETAINING jjjjj WALL7 LPROPOSED RETAINING EXIST I NG 24 ".� WALL FTG. ABUTMENT PILES REMOVE EXISTING ABUTMENT TO TOP OF BARRIER TOP OF FINISH GRADE NEW CAP, 5EE SHEET RW -4 FOR PET AI L5 EXISTING � � 1 BARRIER 21-011 I I I I I �sl I 101-011 , 1 1 - 0„ SECTION A BOTTOM OF 5LA8 VARIES 2' -6" TO 4' -0" 4 5T REAMBEO COBBLES EXIST 1 NG 24 "0 CONCRETE SHAFT TO REMAIN END CONNECTION DETAIL iBTJV00021dms022691BT 405- AB.dpn "llk REGION STATE NO. 10 WASI JOB NUMBER AS -BUILT 716/10 MS CONTRACT NO. NDC 9 - P1 WALL 718/09 RB C -7295 REVISION DATE BY ' e e e e REMOVE EXISTING I ° r SHEET PILE5 TO EL. 6.40 e ---- r - - - - - i e — ---- J{ - - - - - J / r EX15T I NG RETAINING WALL FOOTING TO 4 ►_6„ REMAIN I BRIDGE NO. 405/13 ! r I COLUMN & SHAFT COL. 13 r r13 COL. C P/ A /\/ FIELD FIT PROP05EO WALL FROM EXIST 1 NG SHEET PI LE5 7-0 ABUT EX137- I NG ABUTMENT ELEV. 17.50 PI LEO., VERIFY OI MEN51ON5, MAINTAIN MIN. !- 1' -3" STEM WALL THICKNESS. I i it APPROXIMATE OI MEN510N, FIELD TO ADJUST T O I I MATCH END OF EXISTING RETAINING WALL I ! M EX15T1 NG 5HEET PILE WALL PROPOSED WALL. I i (REMOVE TO EL. 6.40) PER PLAN VERIFY . LOCATIONS AND ELEVATIONS OF I E391 00E NO. 405113 SHAFTS. FEI LO AOJU57' I I i ! WALL TO MAINTAIN 3" MINIMUM CLEARANCE ELEV 6.90 ) ! BETWEEN BRIDGE SHAFT 5 AND RET AI NG WALL ! ! ELEV. 6.40 SHEET PILE TO REMAI N J CONCRETE CLA55 4000W m~ 4 .0 ®_' ELEV. 0.50 i EXI ST I NG 5HEET PILE WALL TO REMAIN—, 5ECT10N rb'N� D- 269033 �z l4rill] :i ir � i SHEET OF SHEETS