Loading...
HomeMy WebLinkAboutD-27220EN ' i n Q I N zz IL z - < - l� <z = N 3` P - ppy1 ° FBI � 3 O 0 SV• fA rf LLJ to z In o6 w `n = z z � Q V uj o�� Q& in � a UI nw m o oN O O W d C E m \E - h Y� o JI °x I i b Hlk 1 4i I 1 II7 - I Asphalt Parking I �L_1 Ila = 1 I I � I CB 923 '•6 3 3 m o`! f I CB CONNECT NEW Tyft 2 i MANHOLE TO DWPING I 1 1 STORM PIPE - 1 I AS -BUILT DRAINING AS RECORDED BY CONTRACTOR FIELD NOTES r AND SURVEY VERIFICATION '���� FROM THE FLUER COMPANY SCALE 1 -14 -2 HOR17. 1" = 20' VERT. 1" = 5' 56 +00 55 +00 54 +00 53 +00 52 +00 51 +00 50 +50 40 J 30 Y 2" E IE = 30.61 (� 12" (W) IF = 31.24 12" (E) IE = 30.0- I�' RECOMMENDED FOR APPROVAL �0 0 '2" (W) IE = 32.35 30 0 30 12' ,W iE = 29:88 Q STORM WATER UPLIi' DATE 2" G.+S , i__ LEW 10" WATER ( i 8" SEWER - '6 L 12" L NEW 10" WATER CPEP @ 1.0% 18 LF 12" 2" GAS TO BE RELOCACTED BY PSEI 18 IF '?" DIP @ 1.0% DIP @ 1.0% NEW 10" VJATFR 25 16 LF 12" CPFP @ 1.0% STORM WATER MAINTENANCE DATE 2" GAS 16 LF 12" CPEP @ 1.0% 8 SP W,' 8" SEWER J7 27 J 2 8 LF 12" CPEP @ 1.0% - SCANNED SEP 1 3 2002 : 6 176 F "D 0 3 CB #25, TYPE 2, 48" DIA. CB #24, TYPE 2, 48" DIA. - CB23, TYPE 2, 48" DIA. R' STA. 54 +82 RT. 1' STA. 53 33.4 RT, V STA 51+86 ' SOLID LOCKING LID SOLID LOCKING LID ! STA 51+79 RT 1.9' .--L _ 35.2e I Rim j SOLID LOCKING LID x i own_ CB #22, TYPE 2. 48" DIA. c:) RIM EL. = 35.16 RIM EL. = 34 +59 I RIM EL_ = 33.44 + _ - (S) IE 38-29 12" (S) IE - 30.56 12" S IE = 30.30 SOLID5LLOCKING LID LJJ 12° N IE 3030 I - _ 12" W) IE = 30.76 12 20 - RIM EL. = 3285 Q 1-2° €) 1,;=- 5Q- 12" (E) IE = 31.21 12" W IE = 30 -40 12 30 -99 icj 3 38-29- 141p it 29_9zi 72" NE IF = 29.93 35 w _ _ _ _ _ _ - - - - - - - - - - - - - - - - - - - - - 12 ES IE = 30.60 GRADE AT CENTER LINT i 2" (4V) iE 29 84 I r,n 12" (SW) IE = 29.93 - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - I 19` (E) IE 29.91 12 N IE = 29.68 148 LF, 12" CPEP SD @ 0.28% 154 LF, 12" CPEP SD @ 0.28% 28 LF, 12" CPEP SD @ 0.28% 30 4 CB #25A, TYPE 1 -- SS J SS SS SS SS "' "+" ET 1 STA. 54+8Z. LT. 18 i �� � CB #25B, TYPE 1 0" WATER CB 2A, TYPE 1 (F-H�) 5T4 -53+ ,rir CB #24B, TYPE 1 C13#23A, TYPE 1 SS SS SS SS L-8" SEWER BI DIRECTIONAL VANED GRATE �- _ STA. 54 +84 RT. 16' _ STA. 54 +82 RT. 16' BI- DIRECTIONAL z34 STA. 53 +34. LT. 17' BI- DIRECTIONAL VANED GRATE - - -- _ - --- STA. 53 +34. RT_ 17' BI- DIRECTIONAL _ VANED GRATE STA. 51 +80 LT. 1J' VA DIRECTIONAL VANED GRATE CB #23B, TYPE 1 I ST 51 +80 RT. 17' BI- DIRECTINAL FIRE HYD_ TEE RIM EL. = 35 64 VANED GRATE - - _ _ - - - -- - - - VANED GRATE 1z=( €, - 02� E) IE - 32 31 RIM €t -3#781 RIM EL = 34 81 - - RIM EL. - 33.86 RIM EL. = 33.82 RIM EL. = 32.74 - 33.58 i RIM EL = 32 88 40 J 30 Y 2" E IE = 30.61 (� 12" (W) IF = 31.24 12" (E) IE = 30.0- I�' RECOMMENDED FOR APPROVAL �0 0 '2" (W) IE = 32.35 30 0 30 12' ,W iE = 29:88 Q STORM WATER UPLIi' DATE 2" G.+S , i__ LEW 10" WATER ( i 8" SEWER - '6 L 12" L NEW 10" WATER CPEP @ 1.0% 18 LF 12" 2" GAS TO BE RELOCACTED BY PSEI 18 IF '?" DIP @ 1.0% DIP @ 1.0% NEW 10" VJATFR 25 16 LF 12" CPFP @ 1.0% STORM WATER MAINTENANCE DATE 2" GAS 16 LF 12" CPEP @ 1.0% 8 SP W,' 8" SEWER J7 27 J 2 8 LF 12" CPEP @ 1.0% - SCANNED SEP 1 3 2002 : 6 176 F "D 0 3