Loading...
HomeMy WebLinkAboutD-275005a� AL�! ELECTRICAL SYMBOLS GENERAL NOTES: SWITCH, PUSH BUTTON, DOUBLE CIRCUIT, MOMENTARY CONTACT Cf CEILING MOUNTED LUMINAIRE (TYPE AND WATTAGE AS NOTED) 1. EXISTING UTILITY AND OTHER SUBSURFACE INFORMATION SHOWN ON -x �x CLAMPED FENCE CONNECTION THESE PLANS IS NOT GUARANTEED TO BE ACCURATE OR COMPLETE. ~ O GROUND ROD f C=cr- 1 LAMP FLUORESCENT LUMINAIRE (TYPE AS NOTED TO SCALE) THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ANY Li Lf) Eo b AUTOMATIC TRANSFER SWITCH - CIRCUIT BREAKER TYPE SUBSURFACE OBJECTS THAT MAY CONFLICT WITH ANY CONSTRUCTION. ry [I -G�— GROUND WIRE WITH EXOTHERMIC WELD CONNECTION nrs Q —G— GROUND WIRE (SIZE AS NOTED) Nc SWITCH, PUSH BUTTON, MUSHROOM HEAD, MOMENTARY CONTACT 2 LAMP FLUORESCENT LUMINAIRE (TYPE AS NOTED TO SCALE) 2. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE W w o Z SWITCHBOARD OR DISTRIBUTION PANELBOA.RD, 277/480V °" NIGHT LIGHT ON EMERGENCY SYSTEM (TYPE AS NOTED TO OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS: °o HAND -OFF- AUTOMATIC SELECTOR SWITCH SCALE) U Z qjS p POWER PANEL, 120/208V °� 120/220 277/480V 45 mm ®� / -°� SWITCH, TEMPERATURE OPERATED NORMALLY OPEN ® EXAMPLE GF A CONTINUOUS ROW OF LUMINAIRES. "A" PHASE (LEFT BUS IN PANEL BLACK BROWN aQN " ,� SPECIAL PANEL OR ENCLOSURE AS NOTED ° "B" PHASE ( CENTER BUS IN PANEL) RED ORANGE Q ` }2 ® (� —I I— CONTACT ® LINEAR FLUORESCENT SUSPENDED FROM CEILING (TYPE AS NOTED "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW o (!) Q ,µ w MOTOR 120V (SIZE AS NOTED) 1 PHASE AND TO SCALE) w Z M NEUTRAL WHITE GRAY $m U 4,sxa MOTOR 480V OR HIGHER (SIZE AS NOTED) 3 PHASE a CONTACT- OVERLOAD, (MOTOR STARTER) BATTERYPACK EMERGENCY EGRESS LIGHTS EQUIPMENT GROUND GREEN GREEN Q V) (2 JUNCTION BOX, FIELD SIZED ISOLATED GROUND GREEN W/ O o � I— CONTACT (RELAY SWITCH, MOTOR OPERATED TIMER, MOTOR YELLOW MOTOR STARTER, MAGNETIC WITH MOTOR CIRCUIT PROTECTOR o Z w J 1°0P STARTER, ETC.) (CR -1 DESIGNATES CONTACT TO BE WITH -u , FLEXIBLE METAL OR LIQUIDTIGHT FLEXIBLE METAL CONDUIT TRACER O Q U ® ENERGY MANAGEMENT CONTROL SYSTEM PANEL 1 4z CONTROL RELAY NO. 1). USE T FOR TIMER, M1 FOR MOTOR AS NOTED w 3: ckf STARTER NO. 1, ETC. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE 6 U - w U ®, 3/4;' #10 G HOME RUN-PANEL/CIRCUIT IE. A OBSERVED ON ALL MEDIUM VOLTAGE SYSTEMS: MOTOR STARTER, MAGNETIC WITH FUSED DISCONNECT SWITCH, _ ? w Q J0�20 SWITCH RATING= 30A /20A =FUSE SIZE -�- COIL (RELAY, TIMER, MOTOR STARTER, ETC.) A %2a,4b,6c / ( /2a =PANEL A AND MEDIUM VOLTAGE O w J (CR -1 DESIGNATES CONTROL RELAY NO. 1) USE T FOR CIRCUIT 2a) SLASH MARKS INDICATE QUANTITY OF CONDUCTORS 4 J m? W 01 DISCONNECT SWITCH (UNFUSED) SWITCH RATING 30A TIMER, M1 FOR MOTOR STARTER NO. 1, D FOR DELAY, ETC. (SIZE NOTED). LONGER SLASH INDICATES NEUTRAL WIRE (IF REQ'D). "A" PHASE (LEFT BUS IN PANEL I STRIPE OF VIOLET TAPE '� N REVERSED SLASH INDICATES GROUND WIRE. "B" PHASE ( CENTER BUS IN PANEL) 2 STRIPES OF VIOLET TAPE 1p DISCONNECT SWITCH (FUSED) SWITCH RATING 30A /30A FUSE w RELAY NSI STANDARD NUMBER FOR FUNCTION "C" PHASE (RIGHT BUS IN PANEL) 3 STRIPES OF VIOLET TAPE U u RATING (NOTED LETTER IDENTIFIES SPECIFIC RELAY) - N HH - -- HANDHOLE CONDUIT, UNDERGROUND, DIRECT BURIED. o ® JUNCTION BOX, SPECIAL (SIZE NOTED, 'VP-=WEATHERPROOF) 4. DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, -�I-- CAPACITOR ® PULL BOX (SIZE NOTED, "WP "= WEATHERPROOF) X FIRE SEAL THROUGH THE WALL CONDUITS & CONDUCTORS SWITCHES, ETC. WITH CIRCUIT IDENTIFICATION. c � o a o y OM METER (TYPE AS NOTED) X FIRE SEAL THROUGI THE WALL WIREWAY & CONDUCTORS PHOTO- ELECTRIC CONTROLLER PE t'V oo O z A - AMMETER : CONDUIT TURNING DOWN o E $n. FLOAT SWITCH KW - KILOWATT METER 1 z cco O 3Q -0 CONDUIT TURNING UP KWH - KILOWATT HOUR METER aw _1v_ RESISTOR PF - POWER FACTOR METER I CONDUIT TERMINATED ABOVE CEILING V - VOLTMETER F a F,r ---' ' -L - RELAY COIL VAR - VAR METER CONDUIT EXPOSED (RIGID METAL !MC, EMT OR AS NOTED) \ c a' v E Q THERMOSTAT FR - FREQUENCY — - - — CONCEALED CONDUIT (UNDERGROUND, UNDER FLOOR, IN WALL OR IN CEILING) £ © ® KEY INTERLOCK T TELEPHONE SOLENOID VALVE a �N BATTERY —FA FIRE ALARM CIRCUIT (ADT) a Q PUSH BUTTON STATION (TYPE AS NOTED) I �_ ^9 DUPLEX RECEPTACLE, 120V, 20. TYPICAL (WP= WEATHER PROOF; GFI= /1 � o Q ° = GROUND CONVECTION GROUND FAULT INTERRUPTER m O FEEDER SCHEDULE DESIGNATION (CABLE SCHEDULE DESIGNATOR) ) /I T Z j • TERMINAL BLOCK 4 TERMINALS I�� DUPLEX RECEPTACLE, 120V, 15A. CIRCUIT 3a �i MEDIUM VOLTAGE CABLE TERMINATION, STRESS CONE ® ( ) k DEDICATED RECEPTACLE ON DEDICATED CIRCUIT ° oal- FUSE INDICATOR LIGHT (RED) R =RED, A= AMBER, oEO (SPECIAL RECEPTACLES TO BE NOTED AS TO MFG. & ag o G= GREEN, B =BLUE CATALOG NUMBER) TRANSFORMER (CAPACITY, PHASE AND VOLTAGE NOTED) WIRE CROSSING, NOT SPLICEDzu SINGLE TWISTLOCK RECEPTACLE 120V, 20A lJ �V TRANSFORMER f FGURPLEX RECEPTACLE, 120V, 20A (YYYI WIRE SPLICED �� SINGLE PHASE 208V RECEPTACLE (TYPE AS NOTED) POTENTIAL TRANSFORMER WITH PRIMARY FUSE THREE PHASE RECEPTACLE (TYPE AS NOTED) oe TR TRANSFORMER RELAY U) `` — CURRENT TRANSFORMER RATIO AS NOTED r ko THREE PHASE RECEPTACLE (TYPE AS NOTED) Jb PIGTAIL CONNECTION 49: DUPLEX RECEPTACLE IN FLOOR CIRCUIT BREAKER, MEDIUM VOLTAGE. FIXED EQUIPMENT IDENTIFIER 7 TELEPHONE OUTLET CIRCUIT BREAKER, MEDIUM VOLTAGE DRAW OUT TYPE J X = tJgMF Y = HP KW, OR KVAO TELEPHONE OUTLET IN FLOOR a EQUIPMENT (AIR CIRCUIT BREAKER) pa HORN = IDENTIFIES LUMINAIRE TYPE & `NATTAGE (A =TYPE, 100= YVATTAGE) zd x �E {III j} DRAW OUT POWER FUSE IT] MANUAL FIRE ALARM PULL STATION j rc WALL MOUNTED LUMINAIRE (TYPE AND WATTAGE AS NOTED) ° s SMOKE DETECTION HEAD -Q- CIRCUIT BREAKER MOLDED CASE, LOW VOLTAGE HIGH INTENSITY DISCHARGE LUMINAIRE (TYPE AND WATTAGE s AS NOTED) O°. HEAT DETECTOR -RATE OF RISE CIRCUIT BREAKER, LOW VOLTAGE DRAW OUT TYPE 0-M ROADWAY /PARKING CUTOFF LUMINAIRE (TYPE AND WATTAGE 6 BUZZER CIRCUIT BREAKER WITH SHUNT TRIP DEVICE AS NOTED) Q COMPUTER WALL OUTLET 01 EXIT LUMINAIRE, CEILING MOUNTED, DIRECTION OF EGRESS $ SINGLE POLE TOGGLE SWITCH VOLTMETER SWITCH NOTED m > �0I EXIT LUMINAIRE, WALL MOUNTED, DIRECTION OF EGRESS $, THREE -WAY TOGGLE SWITCH AMMETER SWITCH NOTED ■ MAGNETIC DOOR RELEASE —0- TEST SWITCH - CONDUIT W/ SEAL FITTING (HAZARDOUS AREAS) NON -FUSED DISCONNECT SWITCH Mai MOTOR CONTROL CENTER FUSED DISCONNECT SWITCH 0 0 GANGED SWITCH, DISCONNECT 0 SWITCH, TOGGLE (MOMENTARY CONTACT) 0 o I u� LL °I.w SWITCH, PUSH BUTTON, MOMENTARY CONTACT y 4 04 0 N 0 CT+ StF1" 04 ® ® e ® s ® ® SIFS°• SiS N - - - - -- ����— CONSTRU TION SET1 TONAL' EXPIRES: 70/05/99 1 °o _ , RECOMMENDED ®Y ® a1z► 1 0 ` iFOR APPROVAL ®Y ; DATE: I( Cry r7 - z�toor y IL