Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
D-281709
A B C 4 1 3 1 2 T 61 REMAIN, TYPICAL _J ®CEDAR RIVER 8-6, %Q &o1/ri© REMSMS orsci�pnow 1. FOR EXISTING TREE LEGEND SEE PLATE L -1 2. ALL TREES TO BE REMOVED SHALL BE REPLACED AS INDICATED ON LANDSCAPE PLANS. 3. EXISTING TREES EQUAL TO OR LESS THAN 5' CALIPER SHALL BE CAREFULLY REMOVED IN ACCORDANCE WITH SPECIFICATIONS, STOCKPILED, AND RELOCATED AS INDICATED ON LANDSCAPE PLANS AND APPROVED BY THE CONTRACTING OFFICER. 4. REMOVAL OF BLACKBERRY AND KNOTWEED SHALL BE REQUIRED WHERE NOTED ON RIGHT BANK AND ON LEFT BANK BE- TWEEN STA 19 +00 AND LOGAN AVE. EDGE. SEE CLEARING AND GRUBBING SPEC. FOR REMOVAL REQUIREMENTS. FLAGGED NOTES, 1I SAWCUT AND REMOVE EXISTING AC /PCC PAVEMENTS AND CURBS AS SHOWN, TYPICAL OF MANY LOCATIONS. © REMOVE AND REPLACE BOLLARDS IN SAME POSITION IN NEW ROADWAY. MAYBE REUSED IF UNDAMAGED. © REMOVE SECTIONS NECESSARY TO COMPLETE WORK AND REPLACE IN SAME POSITION. REMOVED SECTIONS MAYBE REUSED IF UNDAMAGED. 4f� EXISTING CATCH BASIN — PROTECT. REMOVE EXISTING CATCH BASIN AND PIPING. ® OVERHEAD LIGHT TO BE RELOCATED. REUSE EXISTING FIXTURE, SEE PLATES -33 THROUGFC -39 FOR LOCATIONS. © OVERHEAD LIGHT WITH U/G VAULT TO BE RELOCATED. REUSE EXISTING FIXTURE. ® WOOD AND CONCRETE PARK BENCHES TO BE RELOCATED. PLANKS MAYBE REUSED IF UNDAMAGED AT CONTRACTORS OPTION OR REPLACE WITH SIMILAR. SEE FLATE3_ -2 THREIUGHL -10 FOR NEW LOCATIONS. WOOD AND CONCRETE PICNIC TABLES. PLANKS MAYBE REUSED IF UNDAMAGED AT CONTRACTORS OPTION OR REPLACE WITH SIMILAR. SEE PLATESIL-2 THROUGHL -10 FOR NEW L ❑CATIONS. I � ® EXISTING STORM INTERCEPTOR CATCH BASINS. ® RELOCATE BARBEQUE STANDS TO NEW LOCATIONS Ifs ADJACENT TO NEW PICNIC TABLE LOCATIONS AS i SHOWN ON LANDSCAPE PLANS. NO PARKING SIGNS TO BE REMOVED AND RETURNED TO COR. ® YIELD SIGN TO BE RELOCATED BETWEEN FOOT OF LEVEE AND ROAD. ® LIGHTING VAULT — PROTECT. ® WATER VALVE BOX /CASE — PROTECT. ® FIRE HYDRANT — PROTECT. ®EXISTING TREE TO BE REMOVED, TYP. E _Z C -9 C -1 C -3 C -5 C -7 C —a C -2 C-4 C -6 KEY PLAN "0SCALE AS —BUILT 1._30. 30' 15' 0 30' so' IF SHEET IS LESS THAN 32° X 21° IT IS A REDUCED PRINT, REDUCE SCALE ACCORDINGLY U.S. ARMY ENGINEER DISTRICT, SEATTLE CORPS OF ENGINEERS SEATTLE. WASHINCTON LOWER CEDAR RIVER FLOOD CONTROL LEVELS & FLOODWALLS i i DEMOLITION PLAN I 5' wp - 37 - ltd ROLL 176 Ow.oEo DDa 2 F R 0 019 3 RENTON WASHING I C D B -99- 0017 !; E- 19 -1 -70 98DEC03 C -1 ^k BRB ,x vices 9 SCANNED SEP 13 ZWZ e 0