Loading...
HomeMy WebLinkAboutD-283707co � I t1i \ \ ! A� s \ !. ! MODULAR ,BLOCK LL Ci_._ \ SEE 3 n, t uooUlaR \ , , ! (AS IGNED) WALL (AS -BUILD `•\ a.... _ •� ! !I 20 10 0 20 40..1 6C „I NOTE HOME DOWNSPOUTS (LOC UNKNOWN) I, NOTE 8" TIMBERS N P ;` "PIPE 1 : �, I AND, REPLACE AF ! iil TIED INTO EX_ 121 0 BERS ALONG SH ULD REMOVE, SAYE, Ir DO NOT. ABANDON. PIPE CONNECTION TO CB$1. SCALE IN FEET +, WORK IS COMPLETED., I TOE of wntl_ Cf"Y OF RENTON �If�CONTROL; NETWORK wv N 37:.g VERTICAL CONTROL DATUM,:. :» \ INV I 3RD ORDER, 1st CLASS \ \ s¶ 48 \ BCTT 35.sz : \ NAVD 1988 RDA 4, \ ` ! HORIZONTAL CONTROL DATUM INV E 399 F_ 2ND ORDER, 1st CLASS B \ ! ; _ vS38.22 -_- \ \ B�o7i 3G21 CT q 4 ? SAVE AND PRESERVE PLANTS_ REMOVE PLANTER AND TIMBER AS NEEDED NAVD 1983/1991 REBUILD DRIVEWAY, PLANTER, AND REPLANT \ ' \ NrD AFTER NEW c6 S INSTALLED. LEGEND '41 "EVVER f\ 3 y WM 0 WATER METER FH 0 FIRE HYDRANT ✓ � \ ` �` n � _ _.. WV e WATER VALVE CT / J O \ \ \\ r• yr *�riaM ri W WATER LINE %V GV 0 GAS VALVE [� \ 4 CB'E a as �aauc 1\ 12 "CONC SID STORM` DRAIN LINE . L3 \ IM 1EO .,. r.. CB CATCH,, BASIN _ - _ E'; �• 4 4 \_. INV -S• 3853 ,':L _,` ~ \��w "' - - _ SS SANITARY., SEWER !LINE w 32.e6 SSMH SANITARY SEWER MANHOLE I V E 39 OB _o_�_ � � r o GAS LINE �\\ r r MB o MAIL BOX �s X x— FENCE POW VLT E7 POWER VAULT UGT UNDERGROUND TELEPHONE UGP UNDERGROUND POWER ,✓ \, .' .—o STREET LIGHT MIC MONUMENT IN CASE c 1 S SIGN :• '' .:, ,'fi._ -I 1 TJB TELEPHONE JUNCTION BOX I NOTE 3- z _ I I MEASUREMENTS ..; � EDGE OF CONCRETE BASED 0 N SURVEYOR'S MEASURE E 1 , DURING LAKE (WASHINGTON BLVD. REBUILDING .`PROJECT BY CITY OF RENTON TRANSPORTATION: DIVISION 1996 I n I I I • "' : -. - : 1. All Type 2 CBs Shall Have Solid Locking :Lids. NOTE _ _ - PLAN VIEW — 1 " =20* SURVEYED S OVERLAYED DIFFERENT .DULY 2001. 3_ All CB Grates Shall Be Set Pipe:Lines. 20. CB RIM EL'S MAY BEDIFFERENT THAN - . - .:-- ...... ......_..- ... -__ Adjacent Ground Level. e t 0.1 Feet Below Field Adjust Type 1 CB's To Locate At Low Points, ow _ " _. .. _ r� CB# 1 TYPE248 - - CB;� 3 TYPE 248 � C6;�2 TYPE 2 48 � I c-r. In Fl Lines, And To Clear Existing Utilities. 40 35- ; IE EXISTING SANITARY SEWI LINE = - JOB No_ CR00004 STA RINGEL & ASSOCIATES cRc N. LE _ I CERTIFICATION RLS P.O. BOX 742 I HEREBY CERTIFY THAT THE HORIZONTAL AND VERTICAL LOCATIONS OF THE TOPOGRAPHIC ID. #986 CASCADE, IDAHO FEATURES SHOWN HEREON ARE THE RESULT OF WA. #23613 83611 A SURVEY MADE BY ME OR UNDER MY DIRECTIO MT. #7917 +.., (208) 382 -4230 F.D. RINGEL L.S. 23613 DATE:5 /25/00 swp,*7- 7