HomeMy WebLinkAboutD-283707co
� I
t1i \ \ !
A� s
\ !. ! MODULAR ,BLOCK LL Ci_._
\ SEE 3 n,
t
uooUlaR \ , , ! (AS IGNED)
WALL (AS -BUILD `•\ a.... _ •� ! !I 20 10 0 20 40..1 6C
„I
NOTE HOME DOWNSPOUTS (LOC UNKNOWN)
I, NOTE 8" TIMBERS
N P ;` "PIPE
1 : �, I
AND, REPLACE AF ! iil TIED INTO EX_ 121 0
BERS ALONG SH ULD
REMOVE, SAYE, Ir DO NOT. ABANDON. PIPE CONNECTION TO CB$1. SCALE IN FEET
+, WORK IS COMPLETED., I
TOE of wntl_ Cf"Y OF RENTON
�If�CONTROL; NETWORK
wv N 37:.g VERTICAL CONTROL DATUM,:.
:»
\ INV I 3RD ORDER, 1st CLASS
\ \ s¶ 48 \ BCTT 35.sz : \ NAVD 1988
RDA 4,
\ ` ! HORIZONTAL CONTROL DATUM
INV E 399
F_ 2ND ORDER, 1st CLASS
B \ ! ;
_ vS38.22 -_-
\ \ B�o7i 3G21 CT q 4 ? SAVE AND PRESERVE PLANTS_
REMOVE PLANTER AND TIMBER AS NEEDED NAVD 1983/1991
REBUILD DRIVEWAY, PLANTER, AND REPLANT
\ '
\ NrD AFTER NEW c6 S INSTALLED. LEGEND
'41 "EVVER f\ 3 y
WM 0 WATER METER
FH 0 FIRE HYDRANT
✓ � \ ` �` n � _ _.. WV e WATER VALVE
CT /
J O \ \ \\ r• yr *�riaM ri W WATER LINE
%V GV 0 GAS VALVE
[� \
4 CB'E a as �aauc 1\ 12 "CONC SID STORM` DRAIN LINE
.
L3 \ IM 1EO .,. r.. CB CATCH,, BASIN
_ - _ E'; �• 4 4 \_. INV -S• 3853 ,':L _,` ~ \��w "' -
- _ SS SANITARY., SEWER !LINE
w 32.e6 SSMH SANITARY SEWER MANHOLE
I V E 39 OB
_o_�_ � � r o GAS LINE
�\\ r r MB o MAIL BOX
�s
X x— FENCE
POW VLT E7 POWER VAULT
UGT UNDERGROUND TELEPHONE
UGP UNDERGROUND POWER
,✓ \, .' .—o STREET LIGHT
MIC MONUMENT IN CASE
c 1 S SIGN
:• '' .:, ,'fi._ -I 1 TJB TELEPHONE JUNCTION BOX
I
NOTE 3-
z _ I
I MEASUREMENTS
..; � EDGE
OF CONCRETE BASED 0
N SURVEYOR'S MEASURE E
1 ,
DURING LAKE (WASHINGTON BLVD. REBUILDING .`PROJECT
BY CITY OF RENTON TRANSPORTATION: DIVISION 1996
I
n I I
I
• "' : -. - : 1. All Type 2 CBs Shall Have Solid Locking :Lids.
NOTE _
_ -
PLAN VIEW — 1 " =20* SURVEYED S OVERLAYED DIFFERENT .DULY 2001. 3_ All CB Grates Shall Be Set Pipe:Lines.
20. CB RIM EL'S MAY BEDIFFERENT THAN -
. - .:-- ...... ......_..- ... -__ Adjacent Ground Level. e
t 0.1 Feet Below
Field Adjust Type 1 CB's To Locate At Low Points,
ow _
" _. .. _
r� CB# 1 TYPE248 - -
CB;� 3 TYPE 248 � C6;�2 TYPE 2 48 � I c-r.
In Fl Lines, And To Clear Existing Utilities.
40
35- ;
IE EXISTING SANITARY SEWI LINE = -
JOB No_ CR00004
STA
RINGEL & ASSOCIATES cRc
N.
LE _ I CERTIFICATION
RLS P.O. BOX 742 I HEREBY CERTIFY THAT THE HORIZONTAL AND
VERTICAL LOCATIONS OF THE TOPOGRAPHIC
ID. #986 CASCADE, IDAHO FEATURES SHOWN HEREON ARE THE RESULT OF
WA. #23613 83611 A SURVEY MADE BY ME OR UNDER MY DIRECTIO
MT. #7917 +.., (208) 382 -4230 F.D. RINGEL L.S. 23613 DATE:5 /25/00
swp,*7- 7