HomeMy WebLinkAboutD-28620B6 vc ii V v v as V E ..s c V 0 r n� v 10 v> ,c c E V 0 r c 0 c 0 v E 0 ,c u r 0 c v 0 c v u 0 N r c D V cr of u a v t U c v 0 N rn Q 3 r u c v v V v ,c V .E 0 4a 0 0 v� 0 r° 0 1 i ACRONYMS AND ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT Al ANALOG INPUT AL ALUMINUM ALT ALTERNATOR AO ANALOG OUTPUT ASL ALARM SWITCH LOW AWG AMERICAN WIRE GAUGE BATT BATTERY BKR BREAKER C CONDUIT CA CHLORINE ANALYZER CT CURRENT TRANSFORMER CU COPPER DC DIRECT CURRENT DI DISCRETE INPUT DIST DISTRIBUTION DO DISCRETE OUTPUT ENCL ENCLOSURE EX ROOF EXHAUSTER EXIST EXISTING FAH FLOW ALARM HIGH FAL FLOW ALARM LOW FT 2 SQUARE FOOT FE FLOW ELEMENT FI FLOW INDICATOR FIC FLOW INDICATING CONTROLLER FIQ FLOW INDICATING TOTALIZER FQ FLOW TOTALIZER FIR FLOW INDICATING RECORDER FIT FLOW INDICATING TRANSMITTER FSL FLOW SWITCH LOW FT FLOW TRANSMITTER FU FUSE FVNR FULL VOLTAGE NON REVERSING FVR FULL VOLTAGE REVERSING FY FLOW COMPUTATION G GROUNDING CONDUCTOR GND GROUND GRS GALVANIZED RIGID STEEL HC HAND CONTROL HP HORSE POWER IC INTERRUPTING CAPACITY KA KILO AMPERES KAIC KILOAMPERES- INTERRUPTING CAPACITY KCM THOUSAND CIRCULAR MILLS KV KILOVOLT KVA KILOVOLT -- AMPERE KVAH KILOVOLT- AMPERE HOUR KVAR KILOVAR (REACTIVE KILOVOLT AMPERE) KVARH KILOVAR -HOUR KW KILOWATT KWH KILOWATT -HOUR LINE POWER LINE /POWER BLOCK LAH LEVEL ALARM HIGH LAL LEVEL ALARM LOW LI LEVEL INDICATOR LSH LEVEL SWITCH HIGH LSHH LEVEL SWITCH HIGH HIGH LSL LEVEL SWITCH LOW LSLL LEVEL SWITCH LOW LOW LT LEVEL TRANSMITTER LY LEVEL COMPUTATION LPU LINE PROTECTION UNIT M MAGNETIC CONTACTOR MA MILLIAMPERES MAX MAXIMUM MCM MILLION CIRCULAR MILLS MCP MOTOR CIRCUIT PROTECTION MEG MEGAOHM MF MAGNETIC FORWARD CONTACTOR MIN MINIMUM MR MAGNETIC REVERSE CONTACTOR MTS MANUAL TRANSFER SWATCH (ELECTRICALLY OPERATED) MV MILLIVOLT MW MEGAWATT MWH MEGAWATT -HOUR N NEUTRAL CONDUCTOR NEC NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRIC MANUFACTURERS ASSOC. NESC NATIONAL ELECTRICAL SAFETY CODE OL OVERLOAD P POLE PAL PRESSURE ALARM LOW PE PRESSURE ELEMENT PF POWER FACTOR PH or 0 PHASE PI PRESSURE INDICATION PLC PROGRAMMABLE LOGIC CONTROL PRV PRESSURE REDUCING VALVE PS POWER SUPPLY PSI POUNDS PER SQUARE INCH R CIRCULAR CHART RECORDER RPM REVOLUTIONS PER MINUTE S MONITORING STREAMING CURRENT SEC SECOND SHL'D SHIELDED STD STANDARDS SUSS SUITABLE FOR USE AS A SERVICE ENTRANCE TB TERMINAL BLOCK TEFC TOTALLY ENCLOSED FAN COOLED TSP TWISTED SHIELDED PAIR UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT �- - VA VOLT AMPERE VMR VOLTAGE MONITORING RELAY W WATT LN WH WATT HOUR WP WEATHER PROOF XFMR POWER TRANSFORMER ZIC POSITION INDICATING RECORDER ZLL POSITION LIGHT LOW ZLH POSITION LIGHT HIGH ZSH POSITION SWITCH HIGH ZSL POSITION SWATCH LOW ZT POSITION TRANSMITTER ONE LINE DIAGRAM SYMBOL SCHEDULE SYMBOL DESCRIPTION DEVICE OR EQUIPMENT TERMINAL BUSSING CONNECTION BUS HARING WIRING CONNECTED /SPLICED — — — EQUIPMENT /DEVICE ENCLOSURE .�i. PLUG -IN CONNECTION MAGNETIC ONLY BREAKER 1\1 / THERMAL ONLY BREAKER 1` 1 THERMAL MAGNETIC BREAKER / SWITCH FUSE M POWER TRANSFORMER /V\^ CONTROL POWER TRANSFORMER CURRENT TRANSFORMER THERMAL OVERLOAD J' CONTACTOR T -�- CAPACITOR rD -1- GROUND CONNECTION I TRVOLTAGE RELAY TIMING RELAY CONTROL RELAY F FLOAT SNATCH SV SOLENOID VALVE P PRESSURE SWITCH LEVEL SWITCH T FLOW INDICATING TRANSMITTER a TORQUE SWITCH STATION OOOA CO( C E /RAN q AMMETER QUANTITY 0- 600V--�— (SCALE/RANGE) Oy VOLTAGE METER ;-- QUANTITY 55 -66HZ (SCALE/RANGE) (Di FREQUENCY METER QUANTITY o-�w� (SCALE/RANGE) ONE LINE DIAGRAM SYMBOL SCHEDULE YMBOL DESCRIPTION � WATT HOUR METER �- - -- QUANTITY AQ AMMETER SNATCH VMS VOLTMETER SWITCH [7 G� GENERATOR LN SOLID NEUTRAL 15 MOTOR - NO. =HORSE POWER d o SAFETY DISCONNECT IN NEMA 4X ENCL. UNLESS OTHERWISE NOTED L -- AUXILIARY CONTACT r SEAL OFF ELEMENTARY WIRING DIAGRAMS SYMBOL SCHEDULE SYMBOL DESCRIPTION PANEL OR DEVICE WIRING -BY EQUIPMENT VENDOR FIELD WIRING -BY ELECTRICAL CONTRACTOR - -- - -- EQUIPMENT /DEVICE ENCLOSURE -+- -- WIRING CONNECTED + - - WIRING NOT CONNECTED DEVICE OR EQUIPMENT TERMINAL CONTROL PANEL TERMINAL MCC TERMINAL TRANSFORMER WINDING --{�}- FUSE-BUSSMAN FNM OR -E�I- METAL OXIDE VARISTOR (MOV) DIODE RECTIFIER �- GROUND CONTACT BLOCK OPERATORS ELEMENTARY WIRING DIAGRAMS SYMBOL SCHEDULE N.O. N.C. XXCR XXCR LENS COLOR CODE _4�_ XXTR �o- XXTR 'T -XXTR XXTR _XXTR XXTR �o- (DELAY ON ENERGIZATION -ON DELAY) X OL X OL SURFACE OR PENDENT MOUNTED FIXTURE (1 TR,2TR,ETC.) XXDPS �o- WIRING RUN CONCEALED IN SLAB, UNDER XCR XTXR M ELECTRICAL PLAN DRAWINGS SYM130L SCHEDULE SYMBOL DESCRIPTION RELAY CONTACTS INSTANTANEOUS CONTACT OF RELAY (1LT. LIGHTING FIX RES OA HIGH INTENSITY DISCHARGE (HID) (1CR,2CR,ETC.) LENS COLOR CODE ' FIXTURE - WALL MOUNTED A,B,C, ETC. ARE TIMED DELAY CONTACT OF RELAY GLP A =AMBER B FLUORESCENT FIXTURE - REFER TO TYPE. (DELAY ON ENERGIZATION -ON DELAY) XXFLS XXFLS SURFACE OR PENDENT MOUNTED FIXTURE (1 TR,2TR,ETC.) XXDPS �o- WIRING RUN CONCEALED IN SLAB, UNDER C OUTDOOR LIGHT - SCHEDULE TIMED DELAY CONTACT OF RELAY INCANDESCENT "PUSH -TO -TEST" XXLS G =GREEN WALL MOUNTED �p (DELAY ON DE- ENERGIZATION -OFF DELAY) TEST CIRCUIT TO LINE) �— NEUTRAL CONDUCTOR GROUNDING CONDUCTOR ��B (1TR,2TR,ETC.) OF CONDUCTORS. #12 AWG COPPER CONDUCTO, YARD LIGHT POLE W/ FIXTURE(S) TIME RELAY CONTACT OF RELAY (DELAY ON ENERGI ZATI ON, DELAY ON INDICATING AM INSTRUMENTS AMMETER RELAY O SW ICH I N G DE- ENERGIZATION, ON DELAY /OFF DELAY) $ SINGLE POLE SWITCH $ FOUR WAY SWITCH OVERLOAD RELAY (10L,20L,ETC.) WALL MOUNTED 4 WALL MOUNTED TWO WAY SWITCH SWITCH WITH $ 2 WALL MOUNTED PILOT LIGHT MAGNETIC COILS $ THREE WAY SWITCH CONTROL RELAY 3 WALL MOUNTED (1CR,2CR,ETC.) RECEPTACLE OUTLETS TIMED DELAY RELAY DUPLEX RECEPTACLE OUTLET - WALL MOUNTED (1 TR,2TR,ETC.) (NEMA 5 -15R UNLESS OTHERWISE SPECIFIED) MAGNETIC MOTOR STARTER ® SPECIAL PURPOSE EQUIPMENT CONNECTION (1M,2M,ETC.) .� SPECIAL PURPOSE RECEPT. OUTLET- WALL MOUNTED SOLENOID (FOR VALVE UNLESS OTHERWISE NOTED.) --0 SPECIAL PURPOSE EQUIP. CONNECTION- WALL MOUNTED (1 SV,2SV,ETC.) PILOT LIGHTS (1LT. 2LT. ETC.) XXFS LENS COLOR CODE ' XXPS NEON TYPE GLP A =AMBER XXTAS A � 2/20% XXFLS XXFLS W =WHITE field bic no XXDPS XXDPS �o- WIRING RUN CONCEALED IN SLAB, UNDER R =RED XXLS .. �2MP INCANDESCENT "PUSH -TO -TEST" XXLS G =GREEN 06o- �p (CONNECT TEST CIRCUIT TO LINE) �— NEUTRAL CONDUCTOR GROUNDING CONDUCTOR ��B CROSSMARKS INDICATE QUANTITY AND USE OF CONDUCTORS. #12 AWG COPPER CONDUCTO, REQUIRED UNLESS OTHERWISE INDICATED OAMMETER INDICATING AM INSTRUMENTS AMMETER RELAY O HOUR METER ELECTRICAL PLAN DRAWINGS SYMBOL SCHEDULE SYMBOL DESCRIPTION POWER DISTRIBU110N AND CONTROL CONTACT "" "- " - -- -" " OPERATORS "" " � -" - SWITCHBOARD/MOTOR CONTROL CENTER (MCC) N.O. N.C. � FLOOR MOUNTED DISTRIBUTION /CONTROL EQUIPMENT -0 PUSHBUTTON (1P8,2PB,ETC.) DISTRIBUTION/CONTROL EQUI MENT ��o- MUSHROOM HEAD PUSHBUTTON SWITCH (SAFETY OR DISCONNECT (1 P6,2PB,ETC.) Ol � MECHANICALLY HELD PUSHBUTTON OPERATOR � M(1TAD STARTER (uecurnC) "OFF -ON" -0 P SC —i SS OFF HAND AUTO ko I I N.O. N.C. -o o- _< _c N.O. N.C. XXFS XXFS 0� -o-r�- O XXPS XXPS �o— GLP XXTAS XXTAS CCW 2/20% XXFLS XXFLS �o- field bic no XXDPS XXDPS �o- WIRING RUN CONCEALED IN SLAB, UNDER XXLS XXLS .. �2MP ARROWHEAD INDICATES HOMERUN TO PANEL XXLS XXLS 06o- �p `1�W' - A A. n TJ1BT__.Jl[c: W(Dall<s 1E) EI3'T. c;. _ I — ENGINEERING — STREETS — WATER — SEWER— PARKS— BUILDING- ; z *1908* iost So.rd a► OW Ar l8 ,i4Z W Gib GPI/ by Nwdlofi id* Some a MAID IAG"4 ItAX IdaW 1, - ki as q Scar* 1 (% MOTOR STARTER (MANUAL W /OVERLOAD) TWO POSITION SELECTOR SWITCH (1 SS, 2SS, ETC...) 1 MOTOR (NUMBER = HORSEPOWER) THREE POSITION SELECTOR SWITCH (1SS, 2SS, ETC..) "X" = CLOSED IN THIS POSITION I LS CONTACTS SINGLE BREAK CONTACTS PS DOUBLE BREAK CONTACTS (CONTACT BLOCK) PT MECHANICALLY ACTUATED SWTCHES FLOAT SWITCH SV (1 FS, 2FS,ETC.) PRESSURE SWITCH LI (1PS,2PS,ETC.) LS TEMPERATURE ACTUATED SWITCH (THERMOSTAT) (ITAS,2TAS,ETC.) LSH FLOW SW TCH (1 FLS,2FLS,ETC.) PI DIFFERENTIAL PRESSURE SWITCH (1 DPS,2DPS,ETC.) PSL FREE LIMIT SWATCHES (1 LS,2LS,ETC. ) HELD TS OPERATED VALVE INTRUSION DETECTION LIMIT SWITCH PRESSURE SENSOR PRESSURE TRANSMITTER SOLENOID VALVE LEVEL INDICATOR LEVEL SWITCH LEVEL SWITCH HI PRESSURE INDICATOR PRESSURE SWITCH LOW PULLBOX/HANDHOLE TORQUE SW TCH by a °'• CONSULTANTS designed MD 2/20 /01 PRESSURE SWITCH 0 CONTROL STATION 4000A 83301 9TH AVENUE SOUTH FEDERAL WAY, WASHINGTON BERGER/ABAM 98003-2600 E .: , ' " y VOICE: (206)431 -2300 FAX: (206)431 -2250 mor drawn BJA 2/20/01 checked GLP 2/20/b1 p*oj on CCW 2/20% proj air GLP 2/20 /01 field bic no ROLL 2.01 s 0 HPS 150W 120V FIXTURE TYPE " W/ PHOTOCELL 20' --0" HIGH ALUMINUM POLE YM o CONTROLS FLOAT SWITCH (�] UM I T SW TCH P 0 PRESSURE SWITCH 0 CONTROL STATION SV SOLENOID VALVE OT THERMOSTAT SIGNAL SYSTEMS US SMOKE DETECTOR Kl TELEPHONE - SINGLE UNE SYMBOLS 0 GENERAL WIRING„ JUNCTION BOX WIRING RUN EXPOSED IN BUILDING STRUCTURE UNLESS OTHERWISE NOTED WIRING RUN CONCEALED IN SLAB, UNDER SLAB IN CEILING OR WALL OR BELOW GRADE. .. �2MP ARROWHEAD INDICATES HOMERUN TO PANEL NOTED AT END OF ARROWHEAD. NUMBER INDICATES CIRCUIT WITHIN PANEL NOTED. LINE OR PHASE CONDUCTOR �— NEUTRAL CONDUCTOR GROUNDING CONDUCTOR CROSSMARKS INDICATE QUANTITY AND USE OF CONDUCTORS. #12 AWG COPPER CONDUCTO, REQUIRED UNLESS OTHERWISE INDICATED HAND HOLE WITH COVER W/ FUSES AND QUICK DISCONNECTS GROUT BASEPLATE WITH NON- SHRINK CONTRACTOR TO INSTALL ANTENNA CABLE TO ANTENNA CONNECTION IN TELEMETRY PANEL ANTENNA AND ANTENNA CABLE CALVERT TECHNOLOGIES OR EQUAL TO TELEMETRY PANEL IN CONTROL ROOM. 2" GRS CONDUIT, SECURE TIGHT TO POLE FROM BASE OF CONC. TO BASE OF ANTENNA PER CITY REQUIREMENTS BOLT COVER ANCHOR BOLTS INSTALL PER POLE MANUFACTURER'S STD. GROUT ec SIUI;VNt 3/4" CHAMFER TYP. CAULK AT EDGE GRADE •I- — -�I— I I I I-- — J• = I 6- 5 _ _ _ T _ I--►— BARS i l II} I UI r I I'I -' -j'� EVENLY •I I r i I I _ -_ - — I 1 �I II I I I I — _ � / � — _ I i . � SP ACE D CONDUIT FROM N -- USE COMMERCIA L L PANELBOARD LC " 1 I I GRADE CONCRETE CIRCUIT #5 2012. 112G, 3/4 C _ 1 4 - #4 HOOPS O 8 " O.C. . 8 O.C. TOP, BALANCE O 12" O. C. z Li I 1 Q 1 — A 2 r CLEARANCE ANTENNA CABLE, SIZE PER MOTE: MFG'S RECOMMENDATIONS IN ROUND CONCRETE STRENGTH SHALL BE 3,000 PSI 1" PVC CONDUIT CONCRETE PIER AT 28 DAYS. REINFORCING SHALL BE ASTM A615 DEFORMED, GRADE 60. C38 YARD LIGHT /TELEMETRY SCALE: N.T.S. ELECTRICAL SYMBOLS ABBREVIATIONS AND DETAILS SOUTH 180th STREET GRADE SEPARATION • i 129 DETAIL z0B RECORD COPY-_ no dote , revisions r -v- Za 2 P'1 0 ;> H U C40 shut 40 of 144 job- no A00084 scale AS SHOYM dote 20—Fb -2001 u oc C v 1 Cni N c T ^N z