Loading...
HomeMy WebLinkAboutD-28620FELI c v+ c v c 0 v v V E c E V r a� v 0 c 3 c a> E V O 'r c O c 0 v E 0 c v r 0 c v 0 c 0 v a� 0 N O r v c D 3 U n� a v r U c v 0 0 N rn Q 3 m �3 m V c 0 V v c v V 'c 0 V O 0 v► A v z Cam; CONDUIT SCHEDULE ON. ROUP: CON. RUN: FROM: TO: VIA FOR SIZE: CONDUCTORS: G1 checked UTILITY POWER STATION SERVICE pfo j eng IA. 1 B, 1C 2/20/01 pro j dir 1 A UTILITY TRANSFORMER UTILITY DISCONNECT POWER NOTE 4 2 #3, 1 #3N, 1 B UTILITY DISCONNECT UTILITY METER POWER NOTE 4 2 #3, 1 #3N, 1 C UTILITY METER AUTOMATIC TRANSFER SWITCH POWER NOTE 4 2 #3, 1 #3N, G2 VARIOUS POWER SOURCES VARIOUS POWER DESTINATIONS 2A, 2B, 2C, 2D, 2E, 2F 2 A AUTOMATIC TRANSFER SWITCH SECONDARY DISCONNECT POWER 2 1/2" 2 #3, 1#3N, 1#8G 2 B SECONDARY DISCONNECT POWER DISTRIBUTION BLOCK POWER 2 1/2" 2 #3, 1#3N. 1#8G 2 C POWER DISTRIBUTION BLOCK CONTROL PANEL HIGH VOLTAGE OVERHEAD POWER 2 1/2w 2 #3, 1#3N, 1#8G 2 D POWER DISTRIBUTION BLOCK 480V TO 120/240V XFrmr OVERHEAD POWER 2 1/2" 2 #3, 1#3N, 1#8G 2 E 480V TO 120/240V XFrmr LOAD CENTER /PANEL BOARD UNDERGROUND POWER 2" 9999? ?? ?9999? 2 F LOAD CENTER /PANEL BOARD CONTROL PANEL ENCLOSURE - LOW VOLTAGE UNDERGROUND POWER 1" ? ? ? ? ? ? ? ? ? ? ? ?. G3 CONTROL PANEL ENCLOSURE WET WELL SEAL OFF VAULT 3A, 3B, 3C, 3D, 3E, 3F, 3G, 3H 3 A CONTROL PANEL ENCLOSURE PUMP NO.1 SEAL OFF VAULT PUMP CONTROLS 2 1/2" MANUFACTURE SUPPLIED CABLE LOW VOLTAGE &J-BOX 3 B CONTROL PANEL ENCLOSURE PUMP NO.1 SEAL OFF VAULT PUMP POWER 2 1/2" MANUFACTURE SUPPLIED CABLE HIGH VOLTAGE & J -BOX 3 C CONTROL PANEL ENCLOSURE WET WELL SEAL OFF VAULT FLOAT in 2 #14 LOW VOLTAGE & J -BOX 3 D CONTROL PANEL ENCLOSURE WET WELL SEAL OFF VAULT LEVEL TRANSDUCER 1-1/2* MANUFACTURE SUPPLIED CABLE LOW VOLTAGE & J -BOX 3 E CONTROL PANEL ENCLOSURE PUMP NO.2 SEAL OFF VAULT PUMP CONTROLS 2" MANUFACTURE SUPPLIED CABLE LOW VOLTAGE & J--BOX 3 F CONTROL PANEL ENCLOSURE PUMP NO.2 SEAL OFF VAULT PUMP POWER 2-1/2" MANUFACTURE SUPPLIED CABLE HIGH VOLTAGE & J -BOX 3 G CONTROL PANEL ENCLOSURE WET WELL SEAL OFF VAULT SPARE 2" PULL TWINE, CAP AND MARK LOW VOLTAGE I BOTH ENDS OF CONDUIT 3 H CONTROL PANEL ENCLOSURE WET WELL SEAL OFF VAULT SPARE 2" PULL TWINE, CAP AND MARK HIGH VOLTAGE BOTH ENDS OF CONDUIT 4A, 4B, 4C, 4D, G4 STANDBY GENERATOR VARIOUS LOCATIONS 4E, 4F, 4 A STANDBY GENERATOR MAIN BREAKER AUTOMATIC TRANSFER SWITCH STANDBY POWER 2-1/2" 2 #3, 1#3N, 1#8G 4 B STANDBY GENERATOR CONTROL PANEL AUTOMATIC TRANSFER SWITCH CONTROL in 6 #14, 1 #14G CONTROL PANEL ENCLOSURE in 4 C STANDBY GENERATOR CONTROL PANEL LOW VOLTAr� CONTROL 6 #14, 1#14G D GENERATOR BLOCK HEATER PANELBOARD POWER in 1#10, 1#10N, 1#10G 4 BATTERY CHARGER PULL TWINE, CAP AND MARK 4 E STANDBY GENERATOR CONTROL PANEL EAST CONTROL BUILDING WALL SPARE 2" BOTH ENDS OF CONDUIT PULL TWINE, CAP AND MARK 4 F STANDBY GENERATOR CONTROL PANEL EAST CONTROL BUILDING WALL SPARE 2" BOTH ENDS OF CONDUIT G5 VARIOUS LOCATIONS VARIOUS LOCATIONS 5A, 5B, 5C 4 A YARD LIGHT PANEL BOARD POWER 1" 1#12, 1#12N, 1#12G 4 B TELEMETRY ANTENNA CONTROL PANEL ENCLOSURE - LOW VOLTAGE RADIO in OWNER SUPPLIED CABLE IDIP 2 13 40 2 0'rm Jew _ 1908 I>UBLIC WORKS DEPT. - ENGINEERING - STREETS- WATER - SEWER- PARKS- BUILDING- Loo Sowd on ffed Moy !d 2" a ai aWW 0 hW wlen fie Som 0 W"VJA"P ICAX jowsAs J6- 4IMv 9 Scoff I RESPONSE TO RFI #063 lw v v lw V v V v PLEASE PROVIDE THE FOLLOWING ADDITIONAL PARTS FOR THE PUMP STATION CONTROL BUILDING ANDINSTALL PER THE ENCLOSED REVISED ONE --LINE DIAGRAM. PART DESCRIPTIONS ARE SUGGESTIONS ANDTHE ELECTRICAL CONTRACTOR MAY USE OR -EQUAL SUBSTITUTIONS. PLEASE PROVIDE INVOICE DOCUMENTATION FOR ADDITION PARTS TO BE BILLED USING FORCE ACCOUNT GUIDELINES. -3 -PHASE POWER DISTRIBUTION BLOCK - IN PUMP POWER PANEL. (COULD 63133 195 AMP MINI -POWER BOCK) -480 VOLT 3 -PHASE LIGHTNING ARRESTOR (DITEK DTG- 480 -3CM SURGE ARRERSTOR) -WALL MOUNTED 15 KVA 480 VOLT TO 240 /120 VOLT TRANSFORMER -240 /120 VOLT 1 -PHASE LOAD CENTER W /100 AMP MAIN AND 20 CIRCUITS (SQUARE 0 HOMELINE LOAD CENTER PART #HOM20M100C) WE WOULD ALSO LIKE TO HAVE THE ELECTRICAL SUBCONTRACTOR PROVIDE AND INSTALL A 30 AMP 1 -PHASE CIRCUIT BREAKER (COMPATIBLE WITH THE INTALLED � HARDWARE) IN THE MAIN PANELBOARD AS SHOWN IN THE REVISED ON LINE DIAGRAM. THIS BREAKER WILL BE UTILIZED TO PROTECT AND PROVIDE A DISCONNECT FOR THE 480 TO 240 /120 VOLT TRANSFORMER. THE CITY AGREES TO PAY FOR THE ADDITIONAL TIME NECESSARY TO MOUNT THESE ITEMS ON A FORCE ACCOUNT BASIS. PLEASE GIVE ADVANCED NOTIFICATION FOR THE WORK TO COMMENCE TO ALLOW OUR FIELD STAFF TO TRACK THE PROGRESS AND TIME. REQUIRED ADDITIONS: 1 ADD 480A, 3 PHASE POWER DISTRIBUTION BLOCK. WARE TO SOFT START BREAKERS AND PMR FUSES. 2 ADD 480A, 3 PHASE LIGHTING ARRESTOR TO MAIN PANELBOARD. 3 ADD 30AMP, 1 PHASE CIRCUIT BREAKER TO MAIN PANELBOARD. 4 ADD 15KVA 48OV, 1 PHASE TO 240 /120V, 1 PHASE WALL MOUNT NEMA 1 TRANSFORMER. 5 ADD 120 /24OV, 1 PHASE LOAD CENTER, 100A MAIN, 20 CIRCUITS. field ek no AUXILIARY GENERATOR 25 KW_ 31 KVA PRIMARY POWER PUMP No. 1 PUMP No. 2 LEVEL HIGH 20 HP 20 HP WETWELL SENSOR LEVEL FLOAT n PUMP STATION ONE -LINE DIAGRAM - J SCALE: N.T.S. _ ,. .. .� CONSULTANTS BERGER/AB" E N a N Z A S N L 33301 9TH AVENUE SOUTH FEDERAL WAY, WASHINGTON 98003 -2600 VOICE: (206)431 -2300 FAX: (206)431 -2250 PUMP STATION PROPOSED ONE -LINE DIAGRAM SOUTH 180th STREET GRADE SEPARATION . ROLL 27_0. l F IR 13.2 R A RECORD COPY 5 OA7 ADDENDUM 5- -- - - 1 e/70/* ADDENDUM 1 no dote' revisions ZBc. 2 • ZS ENERGY IDARD KW rER R C41 BB O H U _- she+41 B8f 144 job no A00084 - - - -___ -- wde AS SHOMIN dote 20- Feb -2001 Ej a�- J 4 v: (A U. c U ; lit h r. z N V. s M �N C �N by dote designed MO 2/20 /01 drawn 8JA 2/20 /01 checked GLP 2/20/01 pfo j eng 2/20/01 pro j dir GLP 2/20 /01 field ek no AUXILIARY GENERATOR 25 KW_ 31 KVA PRIMARY POWER PUMP No. 1 PUMP No. 2 LEVEL HIGH 20 HP 20 HP WETWELL SENSOR LEVEL FLOAT n PUMP STATION ONE -LINE DIAGRAM - J SCALE: N.T.S. _ ,. .. .� CONSULTANTS BERGER/AB" E N a N Z A S N L 33301 9TH AVENUE SOUTH FEDERAL WAY, WASHINGTON 98003 -2600 VOICE: (206)431 -2300 FAX: (206)431 -2250 PUMP STATION PROPOSED ONE -LINE DIAGRAM SOUTH 180th STREET GRADE SEPARATION . ROLL 27_0. l F IR 13.2 R A RECORD COPY 5 OA7 ADDENDUM 5- -- - - 1 e/70/* ADDENDUM 1 no dote' revisions ZBc. 2 • ZS ENERGY IDARD KW rER R C41 BB O H U _- she+41 B8f 144 job no A00084 - - - -___ -- wde AS SHOMIN dote 20- Feb -2001 Ej a�- J 4 v: (A U. c U ; lit h r. z N V. s M �N C �N