HomeMy WebLinkAboutS-206301CITY OF RENTON
SCHEDULE A= COTTONWOOD LIFT STATION REPLACEMENT, WASTEWATER PROJECT NO. WWP -33 -0510
SCHEDULE B: LAKE WASHINGTON #2 LIFT STATION REPLACEMENT, WASTEWATER PROJECT NO. WWP -11 -2063
Designed By: RH2 ENGINEERING
VICINITY MAP
VICINITY MAP
DRAWING INDEX
z 1 z z
3rd ST
Fi
SCHEDULE A DRAWINGS ONLY SCHEDULE B DRAWINGS ONLY
SHEET NO. DWG N0. DESCRIPTION FILENAME SHEET N0. DWG NO. DESCRIPTION FILENAME
J -E
d � ` J��
U N�
�a>Z a
2Dd ST
s o� WAY N o MT. OLIVET
fa j
1
2
3
_ GENERAL INFORMATION CTNWD08 11 C11 EXISTING SITE PLAN & TESCP LKWSH02
C01 EXISTING SITE PLAN & TESCP CTNWD07 12 C12 PROPOSED SITE PLAN LKWSH03
CO2 PROPOSED SITE PLAN CTNWDO2 13 C13 STRUCTURAL PLAN AND DETAILS LKWSH10
�`
�
N 40th ST
N
-1
s� �5 CEMETERY
Q ¢ LIBERTY oz 5
_J w PARK REVER
a \ PARK
4
6
7
U01 SEWER PROFILE & MANHOLE DETAILS CTNWD03 14 C14 STRUCTURAL DETAILS LKWSH07
CO3 STRUCTURAL PLAN CTNWD09 15 M71 MECHANICAL PLAN & DETAILS LKWSH06
C04 STRUCTURAL DETAILS C-INWDI2 16 E13 ONE LINE DIAGRAM LKWSHO8
M01 17 E14 ELECTRICAL EQUIPMENT PLAN LKWSH09
N 38th $T ¢
N 37th o
Q
LLJ
n zo
z0 J SE 86th
�j
MECHANICAL PLAN &DETAILS CTNWDII
NE 2n
36th ST
8
9
UO3 FIBERGLASS TANK DETAILS CTNWD06
E01 ONE LINE DIAGRAM CTNWD14
N 36th ST
0
CEDAR
10
E02 ELECTRICAL EQUIPMENT PLAN CTNWD10
N 34th ST N 34th ST
¢ d
N
J
rl �3p
N 33rd PL
N 33rd ST
NE 33rd ST
C)
Q � �_
N 32nd ST N 32nd
Q
NE 31st
0
C-)
H
SCHEDULE A&B DRAWINGS
N 31st ST
N 30th ST N 30th ST
ST MAY CREEK
SHEET NO. DWG NO DESCRIPTION FILENAME
N 29th ST
RR
V
18 UO2 MISCELLANEOUS DETAILS CTNWD05
N 28th PL
MAY CREEK PARK
POy
v�
19 E15 ELECTRICAL CONTROLS CTNWD04
N 28th ST
NE 28th ST
CITY OF RENTON
20 E16 TELEMETRY SYSTEM GTNWDI3
CITY
OF RENTON
COTTONWOOD LIFT STATION LOCATION
0 LAKE WASHINGTON
#2 LIFT STATION LOCATION
GENERAL NOTES
METRO CONNECTION NOTES
CONTACT PERSONNEL
1.) THE CONTRACTOR SHALL TAKE ALL NECESSARY SAFETY PRECAUTIONS TO PROTECT THE PUBLIC AND PREVENT NUISANCES WHILE PERFORMING
CONSTRUCTION WORK ON THIS PROJECT.
1.) CONTRACTOR SHALL NOTIFY MR. RICH PUTNEY (684 -1291) AT LEAST TWO WORKING DAYS PRIOR TO CONSTRUCTION IN THE VICINITY OF THE
METRO .INTERCEPTOR.
2.) THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING, PROVIDE FOR NORMAL OPERATION, AND ALLOW ACCESS TO THE EXISTING LIFT STATIONS
2.) DURING CONSTRUCTION, NO DEBRIS SHALL BE ALLOWED TO ENTER METRO'S MANHOLE R10 -16 OR SEWER SYSTEM.
CITY OF RENTON
MIKE BENOIT 277 -6206
UNTIL THE NEW LIFT STATIONS ARE OPERATIONAL AND HAVE BEEN APPROVED BY THE ENGINEER.
CITY OF RENTON
DAVE CHRISTENSEN 277 -6212
3.) THE METRO MANHOLE (R10 -16) SHALL BE UNLOADED ALL .AROUND OR STRUCTURALLY SUPPORTED DURING CONSTRUCTION TO AVOID UNBALANCED
CITY OF RENTON
GARY MORRISON 235 -2585
3.) ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION SHALL CONFORM TO THE CONSTRUCTION DRAWINGS, TECHNICAL SPECIFICATIONS, U.B.C.
SOILS LOADING.
RH2 ENGINEERING
DAN ERVIN 869 -1488
(1988 EDITION), CITY OF RENTON STANDARD PLANS & SPECIFICATIONS, AND THE APWA /DOT STANDARDS SPECIFICATIONS (1991 EDITION).
RH2 ENGINEERING
TONY PARDI 869 -1488
4.) PLANS FOR DEWATERING ADJACENT TO METRO FACILITES SHALL BE SUBMITTED TO MR. RICH PUTNEY FOR METRO REVIEW AND APPROVAL AT
- RH2 ENGINEERING
DAVE DELLA 869 -1488
4.) ALL EXISTING UTILITY LOCATIONS SHOWN ARE APPROXIMATE. THE CONTRACTOR SHALL VERIFY THE TRUE AND CORRECT LOCATION OF EXISTING
LEAST FIVE WORKING DAYS PRIOR TO CONSTRUCTION.
RH2 ENGINEERING
MARK MILLER 869 -1488
UTILITIES TO AVOID DAMAGE OR DISTURBANCE. THE CONTRACTOR SHALL REPAIR ANY DAMAGED UTILITIES IMMEDIATELY.
5.) THE CONNECTION TO THE METRO MANHOLE (R10 -16) SHALL NOT BE BACKFILLED UNTIL IT HAS BEEN INSPECTED AND APPROVED BY METRO.
RENTON POLICE
REVISED TO CONFORM RENTON FIRE DEPT.
344 -4080
235 -2643
5.) A PRE - CONSTRUCTION CONFERENCE AND TWENTY -FOUR HOUR NOTICE WILL BE REQUIRED PRIOR TO STARTING CONSTRUCTION.
TO CONSTRUCTION RECORDS RENTON BUILDING DEPT.
JIM CHANDLER 235 -2540
6.) THE CONTRACTOR SHALL SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION, AND OBTAIN ALL BUILDING DEPARTMENT
6.) FIELD VERIFICATION OF THE LOCATION, DIAMETER, OR INVERT ELEVATION IS RECOMMENDED PRIOR TO CONSTRUCTION.
FIRST AID
%�} ...�'`:a f °:','F PUGET POWER
911
SAM DI RE 235 -2947
INSPECTIONS DURING CONSTRUCTION. SOME OF THE INSPECTION WILL BE PERFORMED BY A REPRESENTATIVE OF THE CITY OF RENTON.
7.) THE NEW CONNECTION TO THE METRO MANHOLE (R10 -16) SHALL BE MADE BY CORE DRILLING INTO THE EXISTING MANHOLE AND USE OF A
RH2 EN61NEERING P.S. (DATE PACIFIC N.W. BELL
345 -8972
THE CONTRACTOR SHALL NOTIFY THE REPRESENTATIVE 24 HOURS IN ADVANCE OF ANY BACKFILLING OF CONSTRUCTION.
"KOR -N- SEAL" BOOT AS DISTRIBUTED BY P.I.P.E., INC.
WA. NATURAL GAS
DEPT. OF ECOLOGY
TOM LING 235 -2464
649
7.) THE EXISTING LIFT STATIONA SHALL NOT HE TAKEN OUT OF SERVICE UNTIL THE NEW LIFT STATIONS HAVE BEEN COMPLETED, TESTED, AND APPROVED
BY THE ENGINEER AND THE CITY OF RENTON.
8.) THE CONNECTION TO THE METRO MANHOLE (R10 -16) SHALL BE PLUGGED AND NOT PUT INTO SERVICE UNTIL THE TRIBUTARY SYSTEM HAS BEEN
CLEANED, INSPECTED, TESTED, AND APPROVED BY THE CITY OF RENTON REPRESENTATIVE.
�� DEPT. OF HEALTH
g� x T.C.I.
-7000
STEVE DEEM 464 -7963
PHIL FISK 433 -3434
° +sg`�7i'�
.� U.S. WEST
JOE DAILY 235 -5857
8.) THE CONTRACTOR SHALL DETERMINE THE SCOPE, TYPE, SIZE, QUANTITY, METHOD OF INSTALLATION, OPERATION, AND REMOVAL OF THE
DEWATERING SYSTEM NECESSARY TO KEEP THE EXCAVATION SITE DEWATERED TO STABILIZE THE SOILS FOR CONSTRUCTION.
9.) A COPY OF THESE CONDITIONS SHALL BE KEPT ON THE JOB SITE FOR USE BY THE CONTRACTOR.
%Pe METRO
- ONE -CALL
RICH PUTNEY 684 -1291
1 -800- 424 -5555
9.) THE CONTRACTOR SHALL DISCHARGE OF WATER FROM THE DEWATERING SYSTEM IN ACCORDANCE WITH THE REQUIREMENTS OF STATE AND
LOCAL REGULATIONS. SILT LADEN WATER SHALL NOT BE DISCHARGED FROM THE SITE INTO STREAMS, RIVERS, OR LAKES AT ANY TIME
.;p 16727
°�rsrse6 °` SIGNED:
S-2063
A
I'IIWP- // -2063
07/28/94
EXPIRES 8/2/94