Loading...
HomeMy WebLinkAboutS-223904GRAVEL BACKFILL FOR WALL ROCKS FOR RETAINING FINISH - CAMLOCK MANHOLE RING WALL -MIN. 2500 LB. GRADE AND COVER. SEE STANDARD PLAN B -25 TOP EL =42.5- / FINISH GRADE MAIN STREET WALL LADDER SEE DETAIL 18 IN. DIA. UT17 1 1 _6w 7%MIN. ✓ � 4' 3' 6 s 36 IN. DIA. CASING 10 ELECTRICAL CONDUIT D. IN. DIA. CHANNEL FROM #S2 D.1. SEWER 10" 45' BEND 54 m 20' 50 BIRD SCREEN z z 2 GROUND UNE io e 46 tO 42 VSQ. CONC. iz SL— OPE 1" 90' LONG ELL MAX 38 10" EXHAUST DUCT I FLEXIBLE 1 I M r COUPLING _.z NOTE: DUCT TO BE CONSTRUCTED OF STL.• 34 10 "0 SCHEDULE 40 PIPE AND WELDING FITTINGS. GALVANIZE AFTER FABRICATION. EXHAUST DUCT DETAIL NTS 30 EXISTING WALL REMOVE AND REPLACE EXISTING WALL TO REMAIN J_ EXISTING WALL PANELS _I_ TO REMAIN 10" EXHAUST DUCT — SEE DETAIL LIGHTING AND FAN CONTROL SWITCH THIS SHEET (INSTALL 240 VOLT SWITCH W/ GROUND. USE NEMA 413 BOX W/ LOCK. SWITCH TO CONTROL LIGHTS AND FANS IN #S2 AND #S3 SIMULTANEOUSLY) UT8 23 ®rte 7 5 4 GROUT ,z Dim. MANHOLE #S3 ELECTRICAL CONDUIT FROM #S2 10 " -90' ELL '`� ROCKS FOR RETAINING CATCH BASIN III WALL MIN. 2500 LB. I III REMOVE AND 0 o o° o °o °o 00 °00 00° o I ° °�� I O 0 � BACKFILL I n 1''v '�0 I FOR Wq NOTE: CASING PIPE LUMP SUM PRICE BID FOR SPECIAL UT8 23 I I I STRUCTURE #S3 INCLUDE: ALL WORK EXCEPT 10 IN. DIAM. D.I. SEWER; KID" D.I. SEWER I SEE SHEET UT8 & UT14 18 IN. DIAM. D.I. SEWER ITEMS AND CASING PIPE 36 IN. DIAM., TUNNELED, JACKED, OR AUGURED. NOTE: T D TOP OF MANHOLE NOT SHOWN Z SITE PLAN 0 F J o W N.T.S. w o o! w z w Z a I FILENAME: UT18 ° ° z w PLOT DATE: 8/29/90 z_ W IN ° DRAWN G.O. Y I 10/92 AS —BUILT PLANS ONLY �oOf na� o�tt, o w w CHECK.EO DNP �%� 9a I x w °n a x PROJ. ENGR. J.E. JOHNSON 9/4/90 REVISED OUTFALL DETAIL J N U U N U) DIST. ADM. R.Q. ANDERSON F/30/901 REVISED OUTFALL DETAIL w 2Z 3, 4� 21 20 19 18 17 18 15 14 13 12 11 Nea STATE FED. AID PROJ. NO. N0. . 10 WASH ACI- 405 - 3(780) JOB NUMBER 90W069 CONTRACT NUMBER 39S-Y I Y I 1 .I I I 10 9 8 7 6 f FLEXIBLE COUPLING SIDE OF MANHOLE NON— SHRINK 5 4 GROUT LL 10 " -90' ELL '`� EXHAUST FAN 800 CFM PER VENTILATION CATCH BASIN SYSTEM IN SPECIAL PROVISIONS REMOVE AND -10" TEE W/ n 1''v BIRD SCREEN EA. OPENING in GROUTED 3" PLASTIC SLEEVE JOINTS FOR WEEP HOLE EXISTING BETWEEN 1 CATCH BASIN WALL REMOVE AND PANELS (TYP.) \ REPLACE WALL PANELS d \ 0 e 3' 4' 3' 10' NOTE: WALL TO BE REMOVED IN COMPLETE SECTIONS TOP OF RIVER BANK TRENCH UMITS GUY POLE SECTION B —B NTS 0 o I o o a 1L\ 1 1 APPROXIMATE LIMIT OF 36" CASING OF EXCAVATION FOR JACKING /BORING PIT ELEVATION — WALL ON MAIN STREET N.T.S. STORM SEWER PIPE TRENCH BOTTOM WILLOW BOUGHS tlV IAMU. CLL NOTE: DETAIL PROVIDED BY WASHINGTON STATE DEPARTMENT OF TRANSPORTATION HAS NO FIELD VERIFICATION HAS BEEN PERFORMED. � �* % 9 � SOUTH RIVER BANK�> WILLOW BO UGHS(TYP.) MATCH EXISTING BANK FILTER FABRIC "z BUDS "(TYP.) 3'xt'x6' 3'xl'x6' NORMAL WATER LEVEL GABIONS RIVER BOTTOM GABION BASKETS l— RIVER BOTTOM � I �I o: } 6, N , 6 SOUTH BANK SECTION STORM SEWER OUTFALL ELEVATION OUTFALL CONSTRUCTION N.T.S. UT10,UT12 HIGHWAY DIVISION w,22 39 APPROVED MICROBOX R147 r � �NAUgF M At WashlVon State SR aoa TUKWILA TO SUNSET BLVD U T18 Department of Transportation CEDAR RIVER PIPELINES- RELOCATION SHEET 115 OF SRS RoseWafer Engineering, Inc SPECIAL STRUCTURE #S3 DETAILS 317 SHEETS I i 1 I I lit I I I I$ 1 6 7 8 9 10 11 12 13 14 SRyos /3/ 15 16 17 18 19