HomeMy WebLinkAboutS-22631DFAN P 6„ a p, o. . v NEW ❑GHT FIXTURES. v v v v v v v v v c v v v v v'. v v 1; v v I� Al \ Al V v, .v ' v HVAC CONTROL PANEL ° ° - -- v ., CONDUITS NOT SHOWN iN THIS VIEW '4 ..n a s a'1 a s 4: 7 DRY WELL VAULT - SECTION A LE2 1" = 2' -0" LIGHTING FIXTURE SCHEDULE MANUFACTURER TYPE DESCRIPTION NAME CATALOG N0, TYPE /SIZE _ - REVISED TO CONFORM TO CONSTRUCTION RECORDS HIGH PRESSURE SODIUM, LARGE WALL LIGHT, 17" SQUARE, NEW HEATING THERMOSTAT 10/24/00 N0. REVISION BY DIE - FORMED ALUMINUM HOUSING, ALUMINUM REFLECTOR, CLEAR DATE EG BUiLDING. HPS Al GLASS LENS, TYPE 2 DISTRIBUTION, DARK BRONZE POLYESTER DAYBRITF WLL20HSMT 150 WATT POWER FINISH, 120 VOLT TO NEW ELECTRICAL HANDHOLE. SCIENTISTS EAST WENATCHEE OFFICE I (INCANDESCENT, INDUSTRIAL, EXPLOSION PROOF, CLASS 1, DIVISION A2 CEILING MOUNTED WITH GLOBE GUARD AND 30' ANGLE CROUSE HINDS EVCX2157 PS -30 200 WATT REFLECTOR. NEW MCC , 11 UTILITY VAULT MODEL 233 -LA WITH GALVANIZED DIAMOND PLATE COVER WITH LOCKING LATCH. OVoVOVOVOVOVQ�,Q 0 0 0 0 0 0 0 I GROUND RODS PER NEC ELECTRICAL CONSTRUCTION NOTES WEATHERPROOF SWITCH FOR WET WELL LIGHT. MOUNT TO ACCESS HATCH IN LOCATION THAT WILL NOT INTERFERE WITH CLOSING OF THE ACCESS HATCH DOORS. WEATHERPROOF DUPLEX GFI RECEPTACLE. MOUNT TO ACCESS HATCH IN LOCATION THA� WILL NOT INTERFERE WITH CLOSING OF THE ACCESS HATCH DOOR. -- 11 1" GRC TELEMETRY CONDUIT 14 GROUND CONDUCTOR - TELEMETRY PANEL - -- - -- RECEPTACLE (TYPI (TYPICAL) WP' 'GF1 Op WET WELL LIGHT SWITCH M e" I � r B � - 1 LE2 - - - LE2 L — — - - - �Z"- - L ACCESS HATCH INTRUSION SWITCH GP-, 0 - i NEW SEWER FORCEMAIN. SEE O 10 _ © M SITE PLAN FOR CONTINUATION. f / J. �T; At L T J ` WP GFI Al NEW ELECTRICAL HEATER REVISED TO CONFORM TO CONSTRUCTION RECORDS MARK MILLER 10/24/00 RH2 ENGINEERING INC. DATE NEW LIGHT FIXTURE--- 1/2" GRC TO BOLLARD FOR HEAT TAPE. 1" = 2' -0" GFI 'HERS. WP J NEW CONDUIT DRAIN PIPE. SEE DWG NO. LE3 FOR DETAILS. T L SYMBOL SCHEDULE DUPLEX OUTLET RECEPTACLE, 120VAC, 20 AMP WITH GROUND PRONG (WATERPROOF WHERE INDICATED WITH WP) - GFI RATFD DEDICATED SINGLE OUTLET GFI RATED RECEPTACLE, 120VAC, 20 AMP WITH GROUND PRONG (FOR SUMP PUMPS AND DEHUMIDIFIER). DUPLEX RECEPTACLES NOT ACCEPTABLE. WEATHERPROOF SWITCH, 120VAC, 20 AMP JUNCTION BOX SIZED PER NEC. SPOT LIMIT SWITCiI THERMOSTAT LIGHT FIXTURE POWER CONDUIT ELECTRICAL NOTES 1. ALL WIRES SHALL BE ROUTED IN RIGID GALVANIZED STEEL CONDUIT UNLESS OTHERWISE NOTED, SIZE AS NOTED ON DRAWING. CONDUIT SHALL BE 1/2" SIZE WHEN NOT NOTED ON PLANS. 2. ALL 240 /120VAC WIRING SHALL BE TYPE THHW INSULATION, INSULATED FOR 600V. SIZE AS NOTED ON DRAWINGS. 3. 480V WIRING SHALL BE ROUTED IN SEPARATE CONDUITS FROM 120V (AND OTHER VOLTAGE) CIRCUITS. 4. ALL WIRE SHALL BE A MINIMUM SIZE #12 UNLESS SHOWN OTHERWISE. LIMPS WITH 5. LOCATION OF CONDUIT ENDS ARE SHOWN APPROXIMATELY. ECEPTACLE FOR CONTRACTOR IS RESPONSIBLE FOR ENDING CONDUITS IN LOCATION EACH PUMP. THAT WILL NOT CONFLICT WITH EQUIPMENT IN THE VAULT. 6. LOCATE ALL LIGHT FIXTURES RECEPTACLES SWITCHES AND DRY WELL VAULT - SECTION DEVICES IN LOCATION SHOWN ON THE PLANS USING ENGINEERING B SCALE UNLESS DIMENSIONED. LE2 = 2' -0" 7. THE MCC SHALL BE MOUNTED ON CONCRETE HOUSEKEEPING PAD AND SECURED BY ANCHOR BOLTS TO PAD AND WALL. 8. LIQUID -TIGHT FLEXIBLE CONDUIT (SAME SIZE AS RIGID CONDUIT) SHALL BE USED AT MOTOR CONNECTIONS IN DRY WELL. ACCESS HATCH OUTLINE SEE DWG NO. LE6 FOR CONTROL LOGIC. NEW IN -LINE EXHAUST FAN DODO VDO CLASS 1 DIVISION 1 AREA UTILITY VAULT MODEL 233 -LA WITH GALVANIZED DIAMOND PLATE COVER WITH LOCKING LATCH. NE TELEMETRY JUNCTION BOX. SEE DWG NO. LE4. ROLL 16,9 Ilk F R 3io)g,, i ! I Al ROUTE FLEXIBLE CONDUIT TO FACILITATE EASE OF MOTOR AND : QUIPMENT MAINTENANCE. 9. CONDUIT ROUTING IS SHOWN DIAGRAMMATIC. CONTRACTOR RESPONSIBLE TO ROUTE CONDUITS IN A NEAT MANNER, PARALLEL OR PERPENDICULAR TO WALLS AND SECURELY ATTACHED TO WALL OR CEILING. NEW EQUIPMENT LEGEND 0 ELECTRICAL WALL HEATER - 1OKW, 240 VOLT, 1 PHASE 34,000 BtuH, ELECTRICAL HEATER WITH UNIVERSAL MOUNTING BRACKET. MOUNT PER MANUFACTURER'S RECOMMENDATION. DAYTON HEAVY -DUTY MODEL OR APPROVED EQUAL. PROVIDE WITH WALL MOUNTED THERMOSTAT ADJUSTABLE BETWEEN 50' TO 807. THERMOSTAT SHALL HAVE A ROOM TEMPERATURE THERMOMETER. SET THERMOSTAT AT 557. © EXHAUST DUCT FAN - 1/4 HP, 115V, 1 PHASE, 2 SPEED MOTOR, INLINE EXHAUST FAN. SEE MECHANICAL PLAN FOR ADDITIONAL DETAILS. SEE DWG NO. LE6 FOR CONTROL AND WIRING DETAILS. CDC COOLING THERMOSTAT - SNAP ACTION, SPST LINE VOLTAGE AIR SWITCH CONTROLLER RATED FOR 1HP MOTOR. RANGE: - 30- 100'F. SET AT 75'F. HONEYWELL MODEL T631CII03 OR APPROVED EQUAL. O SUMP PUMP - 113 HP, 115V, 1 PHASE SUMP PUMP WITH INTEGRAL FLOAT AND DEDICATED PLUG -IN SINGLE RECEPTACLE. (TYPICAL OF 2) I O LOW TEMPERATURE DEHUMIDIFIER - 7.7 AMP, 115V, 1 PHASE, 0.7 PINTS PER HOUR @ 807 RELATIVE HUMIDITY AND 557 TEMPERATURE. EBCO OASIS MODEL OD 3800HG OR APPROVED EQUAL. PROVIDE WITH MOUNTING FIBERGLASS SHELVE MOUNTED TO WALL FOR SUPPORTING THE DEHUMIDIFIER. PROVIDE WITH RUBBER DRAIN HOSE AND FITTINGS TO SUMP PIT. NEW WETWELL LIGHT FIXTURE. MOUNT _ - REVISED TO CONFORM TO CONSTRUCTION RECORDS L� NEW HEATING THERMOSTAT 10/24/00 N0. REVISION BY 1" TELEMETRY CONDUIT FROM DATE EG BUiLDING. LIGHT TOWARDS THE MIDDLE OF THE WETWELL. RH2 ENGtNEERING. INC. �� H X `A NEW 4" PVC CONDUIT FOR g SERVICE FEEDERS. PLANNERS TO NEW ELECTRICAL HANDHOLE. SCIENTISTS EAST WENATCHEE OFFICE SEE DWG NO. LC2. ucxxx`,x1IONU DRAWING $ NOT TO SCALE �'XX�4Cxl — �7cSCR7cAI IF BAR IS NOT 2" LONG O I.. 91S:1.h.X'I" J —s s� f ifu of Renton - Devil's Elbow Sewer and Roadway Improvements - Schedule A LIFT STATION POWER PLAN REVISED TO CONFORM TO CONSTRUCTION RECORDS MARK MILLER 10/24/00 RH2 ENGINEERING INC. DATE NEW LIGHT FIXTURE--- 1/2" GRC TO BOLLARD FOR HEAT TAPE. 1" = 2' -0" GFI 'HERS. WP J NEW CONDUIT DRAIN PIPE. SEE DWG NO. LE3 FOR DETAILS. T L SYMBOL SCHEDULE DUPLEX OUTLET RECEPTACLE, 120VAC, 20 AMP WITH GROUND PRONG (WATERPROOF WHERE INDICATED WITH WP) - GFI RATFD DEDICATED SINGLE OUTLET GFI RATED RECEPTACLE, 120VAC, 20 AMP WITH GROUND PRONG (FOR SUMP PUMPS AND DEHUMIDIFIER). DUPLEX RECEPTACLES NOT ACCEPTABLE. WEATHERPROOF SWITCH, 120VAC, 20 AMP JUNCTION BOX SIZED PER NEC. SPOT LIMIT SWITCiI THERMOSTAT LIGHT FIXTURE POWER CONDUIT ELECTRICAL NOTES 1. ALL WIRES SHALL BE ROUTED IN RIGID GALVANIZED STEEL CONDUIT UNLESS OTHERWISE NOTED, SIZE AS NOTED ON DRAWING. CONDUIT SHALL BE 1/2" SIZE WHEN NOT NOTED ON PLANS. 2. ALL 240 /120VAC WIRING SHALL BE TYPE THHW INSULATION, INSULATED FOR 600V. SIZE AS NOTED ON DRAWINGS. 3. 480V WIRING SHALL BE ROUTED IN SEPARATE CONDUITS FROM 120V (AND OTHER VOLTAGE) CIRCUITS. 4. ALL WIRE SHALL BE A MINIMUM SIZE #12 UNLESS SHOWN OTHERWISE. LIMPS WITH 5. LOCATION OF CONDUIT ENDS ARE SHOWN APPROXIMATELY. ECEPTACLE FOR CONTRACTOR IS RESPONSIBLE FOR ENDING CONDUITS IN LOCATION EACH PUMP. THAT WILL NOT CONFLICT WITH EQUIPMENT IN THE VAULT. 6. LOCATE ALL LIGHT FIXTURES RECEPTACLES SWITCHES AND DRY WELL VAULT - SECTION DEVICES IN LOCATION SHOWN ON THE PLANS USING ENGINEERING B SCALE UNLESS DIMENSIONED. LE2 = 2' -0" 7. THE MCC SHALL BE MOUNTED ON CONCRETE HOUSEKEEPING PAD AND SECURED BY ANCHOR BOLTS TO PAD AND WALL. 8. LIQUID -TIGHT FLEXIBLE CONDUIT (SAME SIZE AS RIGID CONDUIT) SHALL BE USED AT MOTOR CONNECTIONS IN DRY WELL. ACCESS HATCH OUTLINE SEE DWG NO. LE6 FOR CONTROL LOGIC. NEW IN -LINE EXHAUST FAN DODO VDO CLASS 1 DIVISION 1 AREA UTILITY VAULT MODEL 233 -LA WITH GALVANIZED DIAMOND PLATE COVER WITH LOCKING LATCH. NE TELEMETRY JUNCTION BOX. SEE DWG NO. LE4. ROLL 16,9 Ilk F R 3io)g,, i ! I Al ROUTE FLEXIBLE CONDUIT TO FACILITATE EASE OF MOTOR AND : QUIPMENT MAINTENANCE. 9. CONDUIT ROUTING IS SHOWN DIAGRAMMATIC. CONTRACTOR RESPONSIBLE TO ROUTE CONDUITS IN A NEAT MANNER, PARALLEL OR PERPENDICULAR TO WALLS AND SECURELY ATTACHED TO WALL OR CEILING. NEW EQUIPMENT LEGEND 0 ELECTRICAL WALL HEATER - 1OKW, 240 VOLT, 1 PHASE 34,000 BtuH, ELECTRICAL HEATER WITH UNIVERSAL MOUNTING BRACKET. MOUNT PER MANUFACTURER'S RECOMMENDATION. DAYTON HEAVY -DUTY MODEL OR APPROVED EQUAL. PROVIDE WITH WALL MOUNTED THERMOSTAT ADJUSTABLE BETWEEN 50' TO 807. THERMOSTAT SHALL HAVE A ROOM TEMPERATURE THERMOMETER. SET THERMOSTAT AT 557. © EXHAUST DUCT FAN - 1/4 HP, 115V, 1 PHASE, 2 SPEED MOTOR, INLINE EXHAUST FAN. SEE MECHANICAL PLAN FOR ADDITIONAL DETAILS. SEE DWG NO. LE6 FOR CONTROL AND WIRING DETAILS. CDC COOLING THERMOSTAT - SNAP ACTION, SPST LINE VOLTAGE AIR SWITCH CONTROLLER RATED FOR 1HP MOTOR. RANGE: - 30- 100'F. SET AT 75'F. HONEYWELL MODEL T631CII03 OR APPROVED EQUAL. O SUMP PUMP - 113 HP, 115V, 1 PHASE SUMP PUMP WITH INTEGRAL FLOAT AND DEDICATED PLUG -IN SINGLE RECEPTACLE. (TYPICAL OF 2) I O LOW TEMPERATURE DEHUMIDIFIER - 7.7 AMP, 115V, 1 PHASE, 0.7 PINTS PER HOUR @ 807 RELATIVE HUMIDITY AND 557 TEMPERATURE. EBCO OASIS MODEL OD 3800HG OR APPROVED EQUAL. PROVIDE WITH MOUNTING FIBERGLASS SHELVE MOUNTED TO WALL FOR SUPPORTING THE DEHUMIDIFIER. PROVIDE WITH RUBBER DRAIN HOSE AND FITTINGS TO SUMP PIT. NEW WETWELL LIGHT FIXTURE. MOUNT _ - REVISED TO CONFORM TO CONSTRUCTION RECORDS DJB MLM 10/24/00 N0. REVISION BY REVIEW DATE REFLECTOR TO DIRECT LIGHT TOWARDS THE MIDDLE OF THE WETWELL. RH2 ENGtNEERING. INC. �� H X `A ENGINEERS PCTHEI_L OFFICE PLANNERS SCIENTISTS EAST WENATCHEE OFFICE 16727 R6CISTSST�t SIGNED: 06112, 198 EXPIRES 8/2/01 ucxxx`,x1IONU DRAWING $ NOT TO SCALE �'XX�4Cxl — �7cSCR7cAI IF BAR IS NOT 2" LONG O I.. 91S:1.h.X'I" J —s s� f ifu of Renton - Devil's Elbow Sewer and Roadway Improvements - Schedule A LIFT STATION POWER PLAN /2 . . 5 z?"Z" /t3 ORE I DEC 07, 2000 1 SHOWN 1 (v W