HomeMy WebLinkAboutS-22631ENEW EQUIPMENT LEGEND OWET WELL FLOAT SWITCHES - ANCHOR SCIENTIFIC, INC ROTO -FLOAT TYPE S OR APPROVED EQUAL. PROVIDE SUFFICIENT CABLE LENGTH TO EXTEND FROM 3LTTOM OF WET WELL TO JUNCTION BOX PLUS 5' OF LOOPED SLACK FOR ADJUSTMENT. © WET WELL LEVEL TRANSMITTER - Krr ^Si MODEL 720 - 140 - 0005 -009 WITH CABLE HANGER OR APPROVED EQUAL. 0 -5 PSIG, 4 -20mA, 9 -30 VDC EXCITATION VOLTAGE. PROVIDE WITH SUFFICIENT CABLE LENGTH FROM B^TTOM Gr WET WELL TO TELEMETRY PANEL WITH MINIMUM OF 5 FEET OF SLACK. INSTALL TRANSDUCER AS DETAIL ON DWG NO. LM3. C INTRUSION ^I.. =P3 SWIT(H - SQUARE D HEAVY DUTY TYPE C, CLASS 9007 OR APPROVLU EQUAL. USE - IQI!ID TIGHT FLEXIBLE CONDUT BETWEEN JUNCTION BOX AND LIMIT SWITCH. CONTRACTOR TO SELECT ACTUATOR LEVER ,ARM BEST SUITED FOR MOUNTING CCN IGURHTION. C CHECK VALVE POSITION LIMIT SWITCH - SQUARE D HEAVY DUTY TYPE C, CLASS 9007 OR APPROVED EQUAL. USE LIQUID TIGHT FLEXIBLE CONDUIT BETWEEN JUNCTION BOX AND LIMIT SWITCH. CONTRACTOR TO SELECT ACTUATOR LEVER ARM BEST SUITED FOR MOUNTING CONFIGURATION. PHOTO ELECTRIC SMOKE DETECTOR - 24VDC POWERED WITH CONTACTS FOR REMOTE REMOTE ANNUNCIATION THROUGH TWO WIRE CONNECTION TO THE TELEMETRY PANEL. ELECTRO SIGNAL COMPANY MODEL ES- 611UT. NO SUBSTITUTION. v FLOOD SWITCH - OMEGA MODEL NO. LV -10 OR APPROVED EQUAI -. '.FOUNT TO END OF 1 /4" PVC PIPE & SECURE TO WALL WITH MINIMUM OF TWO STAINLESS STEEL PIPE CLAMPS. SWITCH SHALL TRIP AT 112" OF WATER LEVEL. I I PANIC BUTTON - SQUARE D HEAVY DUTY TYPE, CLASS 9001, MODEL NO. KR5RH5 OR APPROVED EQUAL. FURNISH PERMANENTLY MOUNTED "PANIC ALARM - PUSH TO ALARM" SIGN ABOVE BUTTON. SIGN TO BE RED WITH 1/4" HIGH WHITE LETTERING. NEW POWER AND TELEMETRY HANDHOLE. SEE DWG NO. LE2. UTILITY VAULT MODEL 233 -LA WITH GALVANIZED IAMOND PLATE COVER WITH 3 LOCKING LATCH. I---- . �v °v °v °v °v °v °v0 0000000. ACCESS HATCH OUTLINE NEW SEWER FORCEMAIN. SEE SITE PLAN FOR CONTINUATION 4" POWER CONDUIT NEW MCC NEW CONDUIT SCHEDULE I� DESCRIPTION 21 2" PVC COATED GRC, LEVEL TRANSDUCER CABLE 22 2" PVC COATED GRC, (2) JACKETED FLOAT CABLE 23 2" GRC, 8 - #14 24 2" GRC, TRANSDUCER JACKETED CABLE 25 112" GRC, 2 - #14 + 1 - #14 GRD 26 1/2" GRC, 4 -#14 + 1 - #14 GRD 27 1/2" GRC, 2 - #14 + 1 - #14 GRD 28 3/4" GRC, 4- CONDUCTOR TWISTED SHIELDED 29 1 112" GRC, 18 - #14, (2) - 2 CONDUCTOR TWISTED SHIELDED 30 112" GRC, 4 - #14 + 1 -#14 GRID 31 1/2" GRC, 4 - #14 32 1/2" GRC, 2 -#14 33 11" PVC, (1) - 12 - #18 CONDUCTOR SHIELDED CABLE CONDUIT FROM FIELD EQUIPMENT ti I NOTE: 1-1 AEI CONDUIT ENTERING FROM THE OUTSIDE INTO THE VAULT SHALL BE INSTALLED PER THIS DETAIL ELECTRICAL GRC TEE 2.) PROVIDE ALL NECESSARY PIPE, 'CONDUIT, FITTINGS, WITH BUSHING TO 1" ON WALL CLAMPS, CEMENT, ETC. TO COMPLETE THE BRANCH. CONDUIT DRAIN SYSTEM. GRC LB FITTING. SIZE TO MATCH CONDUIT SIZE CALLED OUT ON USE GROUSE -HINDS LINK -SEAL FOR PLANS. I ALL CONDUIT PENETRATIONS INTO VAULT. PENETRATIONS SHALL BE WATERTIGHT. NEW DRY WELL VAULT �! - 1" PVC SCHEDULE 40 PIPE (� (TYPICAL) PLAN VIEW MOTOR CONTROL CENTER ELECTRICAL GRC TEE FITTING GRC LB FITTING. ELECTRICAL GRC NIPPLE 3RC e R _ �fi TT1NG. WITH 1" BUSHED TAP TO 1" � CONNECTED TO MCC. PIPE. NEW MOTOR — ' DRAIN PIPE CONTROL CENTER ELECTRICAL GRC NIPPLE CONNECTED TO MCC. DRAIN PIPE CONNECTED TO ALL CONNECTIONS TO ELECTRICAL NEW MOTOR \4 EQUIPMENT. CONTROL CENTER ,A\ \. ATTACH DRAIN PIPE SECURELY TO WALL � AT 4 FOOT SPACING WITH STAINLESS STEEL PIPE SUPPORTS. CONDUIT DRAIN DETAIL = V -0' ACCESS HATCH OUTLINE NEW CONDUIT. CONNECT TO EXISTING HANDHOLE LOCATED NEAR TOE OF SLOPE. HANDHOLE MAY BE LOCATED UNDER DIRT COVER. CONTRACTOR SHALL LOCATE AND EXPOSE HANDHOLE AS PART OF THIS CONTRACT. NEW LIGHT FIXTURE NEW DRY WELL VAULT REVISED TO CONFORM TO CONSTRUCTION RECORDS MARK MILLER 10/24/00 RH2 ENGINEERING INC. DATE NEW SIGNAL PLAN 1" = 2' -0'• NEW WET WELL SYMBOL SCHEDULE 5 NEW POWER HANDHOLE. SEE FT FLOW TRANSMITTER DWG NO. LE2. LEVEL TRANSMITTER TELEMETRY NOTES: LEVEL SWITCH (FLOATS) 0 0 O 0 TELEMETRY PANEL WILL BE PROVIDES N-Pi THE CLASS 1 DIVISION 1 AREA REQUIRED INTRINSICALLY SAFE' BARRIER EQUIPMENT FOR NEW TELEMETRY PANEL UTILITY VAULT MODEL CONNECTIONS TO THE FLOATS AND LEVEL 'TRANSDUCER. PROVIDED BY OTHERS. 233 -LA WITH GALVANIZED INSTALLED BY CONTRACTOR DIAMOND PLATE COVER WITH THIS CONTRACT. LOCKING LATCH. f °0° CONDUIT DRAIN DETAIL = V -0' ACCESS HATCH OUTLINE NEW CONDUIT. CONNECT TO EXISTING HANDHOLE LOCATED NEAR TOE OF SLOPE. HANDHOLE MAY BE LOCATED UNDER DIRT COVER. CONTRACTOR SHALL LOCATE AND EXPOSE HANDHOLE AS PART OF THIS CONTRACT. NEW LIGHT FIXTURE NEW DRY WELL VAULT REVISED TO CONFORM TO CONSTRUCTION RECORDS MARK MILLER 10/24/00 RH2 ENGINEERING INC. DATE NEW SIGNAL PLAN 1" = 2' -0'• NEW WET WELL SYMBOL SCHEDULE 5 SMOKE DETECTOR FT FLOW TRANSMITTER LT LEVEL TRANSMITTER L5 LEVEL SWITCH (FLOATS) Z5 EVENT SWITCH (PANIC BUTTON) J JUNCTION BOX SIZED PER NEC. SPOT LIMIT SWITCH -.- .- SIGNAL CONDUIT ELECTRICAL NOTES 1. ALL WIRES SHALL BE ROUTED IN RIGID GALVANIZED STEEL CONDUIT UNLESS OTHERWISE NOTED, SIZE AS NOTED ON DRAWING. CONDUIT SHALL BE 1/2" SIZE WHEN NOT NOTED ON PLANS. 2. ALL WIRING SHALL BE TYPE THHW INSULATION, INSULATED FOR 600V. SIZE AS NOTED ON DRAWINGS. 3. ALL SIGNAL WIRE SHALL BE A MINIMUM SIZE #14 UNLESS SHOWN OTHERWISE. 4. LOCATION OF CONDUIT ENDS ARE SHOWN APPROXIMATELY. CONTRACTOR IS RESPONSIBLE FOR ENDING CONDUITS IN LOCATION THAT WILL NOT CC- ` -"1JCT 'NTH EQUIPMENT IN THE VAULT. 5. CONDUIT ROUTING IS SHOWN DIAGRAMMATIC. CONTRACTOR RESPONSIBLE TO ROUTE CONDUITS IN A NEAT MANNER, PARALLEL OR PERPENDICULAR TO WALLS AND SECURELY ATTACHED TO WALLS AND COILING. 6. CONTRACTOR SHALL PROVIDE AND INSTALL ALL CONDUIT, CONDUCTORS, AND CABLES FROM THE FIELD DEVICES TO THE TELEMETRY PANEL. THE TELEMETRY INTEGRATOR WILL INSTALL THE PANEL ALL WIRES AND CABLES SHALL BE CLEARLY IDENTIFIED TO THE THE DEVICE THEY CONNECT. PROVIDE SUFFICIENT CABLE LENGTH FROM FIELD DEVICE TO TELEMETRY PANEL PLUS A MINIMUM OF 4 FEET OF EXTRA LENGTH LOOPED IN TELEMETRY PANEL. TELEMETRY INTEGRATOR WITH CONNECT WIRING TO THE TERMINAL BLOCKS. 5mb226vVE SIGNAL CONNECTIONS FROM TELEMETRY TO MCC (TYPICAL BOTH PUMPS) 1.) PUMP RUN 2.) VFD FAIL 3.) PUMP CALL 4.) SEAL FAIL 5.) HIGH MOTOR TEMPERATURE 64 DEFAULT -SPEED 7.) SPEED REFERENCE (ANALOG) PHASE FAILURE CONNECTION TO POWER MONITORING DEVICE.' _ I � i 1 15 LT ` REVISED TO CONFORM TO CONSTRUCTION RECORDS DJB MLM 10/24/00 NO. REVISION BY REVIEW DATE -.� RH2 ENGINEERING. INC.. H i O�DOO l J I 21 ENGINEERS BoTHELE OFFICE UTILITY VAULT 24 -- PLANNERS MODEL 233 -LA / SCIENTISTS EAST WENATCHEE OFFICE 16727 \ -- WITH GALVANIZED f P.013T� SIGNED: em DIAMOND PLATE _ tONA 4 COVER WITH DRAWING IS NOT TO SCALE ` 06/12/98 LOCKING LATCH. IF HAR IS NOT 2° LONG exalRES a /z /o1 O 2„ V V V V V °o °,e of Pity of Renton - Devil's Elbow NEW TELEMETRY HANDHOLE. Sewer and Roadway Improvements - Schedule S LIFT STATION SIGNAL PLAN I%nLL 16�9--- F R 30:9 DEC 07, 2000 SHOWN