Loading...
HomeMy WebLinkAboutS-231402I ° z O Qo � w 0 w O � J m ° a W o a i z � w a/ a w � J X U / m 0 X ° X m V � z � N = w � � � w z O X m ° ° O � S � ti c7 Z X 2 = w a yJ O � lei i CLEANOUT CONNECT TO MECH. IE 15.0 FF= 22.0 1OLF 6" SSS 0 2.0% c � �s 9 8 C1SA STORAGE WELL CONTROL PANEL FLECTRICAI CO_ ND. n — VENT TO DEDICATED MECHANICAL RISER IN BUILDING —PUMP STATION. /-45' BEND (MJxMJ) CONCRETE BLOCKING PER CITY OF RENTON SIANDARD 085 OK (TYP.) x--45' BEND (MJxMJ) ..... ___... 4" DIP FORCEMAIN \ /-45' BEND (MJxMJ) STORAGE WELL & PUMP STATION ELEVATION e SCALE 1 " =2' Ci6A WW - xy- 1 .1IT SEE DRAWING C16 FOR CONTINUATION 6" CRUSHED SURFACING BASE COURSE (TYP) PUMP STATION NOTES: 1. DUPLEX PUMPS AND MOTORS AND RAIL ASSEMBLY SHALL BE UL LISPED EXPLOSION PROOF AND LABELED FOR CLASS 1, DIVISION 1, GROUP D SERVICE. PUMPS SHALL BE NON -CLOG SUBMERSIBLE TYPE CAPABLE OF PASSING A 3" SOLID. EACH PUMP SHALL BE CAPABLE OF 80 GPM AT 19 FEET TDH. MOTOR VOLTAGE AND PHASE SHALL BE COMPATIBLE WITH SERVICE FROM BUILDING. RAIL SYSTEM SHALL ALLOW PUMP REMOVAL WITHOUT ENTERING PUMP STATION. 2. CONTROL PANEL SHALL BE DESIGNED BY THE MECHANICAL/ ELECTRICAL DESIGN BUILT CONTRACTOR FOR COMPATIBILITY WITH THE PUMP STATION. THE PANEL SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: • NEMA 3R ENCLOSURE. • UL LISTED FOR ENCLOSED INDUSTRIAL CONTROL PANEL. • HAND /OFF /AUTO SELECTOR SWITCHES, WITH PUMP INDICATING LIGHT. • PUMP ELAPSED TIME METERS. • DUPLEX PUMP SEQUENCING WITH ALTERNATOR. • ALARM SHALL TRIGGER A PANEL MOUNTED ALARM LIGHT AND A REMOTE RED ALARM LIGHT MOUNTED IN A VISIBLE LOCATION. • ALARM SHALL BE MOUNTED TO A 24 HOUR TELEMETRY AUTO- DIALER. • PLUG FOR EMERGENCY POWER GENERATOR 3. ALL MATERIALS OF CONSTRUCTION INSTALLED IN THE STORAGE WELL AND PUMP STATION SHALL BE EXPLOSION PROOF AND COMPATIBLE WITH THE HAZARDOUS LOCATION. 4. FINAL DESIGN (INCLUDING MATERIAL SUBMITTAL) SHALL BE SUBMITTED TO AND REVIEWED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. SUBMITTAL SHALL BE BY LICENSED P. E. IN STATE OF WA. PER CITY REVIEW COMMENTS PER CITY REVIEW COMMENTS NO, REVISION I 44 f 1 1'li 114 U dl )I�i l 9� 7 MANHOLE (84 ") S - 23/402 RECOMIAENDC.D FOR APPROVAL ALL 48 HOURS RIM 21.0 [B!EFORE YOU DIG - 800 - 424 -5555 .�.Y�. HYDRORAIL WITH CHECK HATCH TO BE L101 Third AVerM Sulte 900 Q4 py wasfl� OF, ELECTRICAL CONDUIT PRECAST VALVE VAULT & DISCONNECT OR EQUAL COMPATIBLE WITH CITY OF RENTON Po, mFC24711 '� W4 �aSS'41sT TO CONTROL PANEL SIZE AS REQUIRED SANITARY SEWER PUMP STATION PUMP RAIL SYSTEM HUNTER DOUGLAS, INC. i oesicN�u JBM— DATE, 30MAY97 DRAWN DKR EGR LFN CNECK�D: JDE SCAI -L. AS NOTED Pu.e NnraE: HOUT.DWG JOE MAV 30MAY97 N" r AGC MAV 5/12/97 BY APPN OA TL APPROVI 11 -" SH :C16A- C18 CHECK VALVE VENT TO BUILDING "' SIZE BY MECHANICAL % GATE VALVE IE 18.0 / 1 8" PVC TO STORAGE r /4DUCTILE WELL " 4 GALVANIZED III IRON FORCEMAIN STEEL FORCEMAIN ANCHORED AGAINST THRUST MERCURY FLOAT SWITCHES '- IE 14.8 EL 14.2 ALARM SIDE SEWER FROM BUILDING 7 EL 13.7 PUMP 2 ON I EL 12.2 PUMP 1 ON (2) DUPLEX PUMPS W /RAIL SYSTEM - EL 10.7 PUMP OFF 1 1 1 1 EL 8.7 BOTTOM SLAI1 ° 84' - PUMP STATION ELEVATION B SCALE 1 " =2' C16A PUMP STATION NOTES: 1. DUPLEX PUMPS AND MOTORS AND RAIL ASSEMBLY SHALL BE UL LISPED EXPLOSION PROOF AND LABELED FOR CLASS 1, DIVISION 1, GROUP D SERVICE. PUMPS SHALL BE NON -CLOG SUBMERSIBLE TYPE CAPABLE OF PASSING A 3" SOLID. EACH PUMP SHALL BE CAPABLE OF 80 GPM AT 19 FEET TDH. MOTOR VOLTAGE AND PHASE SHALL BE COMPATIBLE WITH SERVICE FROM BUILDING. RAIL SYSTEM SHALL ALLOW PUMP REMOVAL WITHOUT ENTERING PUMP STATION. 2. CONTROL PANEL SHALL BE DESIGNED BY THE MECHANICAL/ ELECTRICAL DESIGN BUILT CONTRACTOR FOR COMPATIBILITY WITH THE PUMP STATION. THE PANEL SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: • NEMA 3R ENCLOSURE. • UL LISTED FOR ENCLOSED INDUSTRIAL CONTROL PANEL. • HAND /OFF /AUTO SELECTOR SWITCHES, WITH PUMP INDICATING LIGHT. • PUMP ELAPSED TIME METERS. • DUPLEX PUMP SEQUENCING WITH ALTERNATOR. • ALARM SHALL TRIGGER A PANEL MOUNTED ALARM LIGHT AND A REMOTE RED ALARM LIGHT MOUNTED IN A VISIBLE LOCATION. • ALARM SHALL BE MOUNTED TO A 24 HOUR TELEMETRY AUTO- DIALER. • PLUG FOR EMERGENCY POWER GENERATOR 3. ALL MATERIALS OF CONSTRUCTION INSTALLED IN THE STORAGE WELL AND PUMP STATION SHALL BE EXPLOSION PROOF AND COMPATIBLE WITH THE HAZARDOUS LOCATION. 4. FINAL DESIGN (INCLUDING MATERIAL SUBMITTAL) SHALL BE SUBMITTED TO AND REVIEWED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. SUBMITTAL SHALL BE BY LICENSED P. E. IN STATE OF WA. PER CITY REVIEW COMMENTS PER CITY REVIEW COMMENTS NO, REVISION I 44 f 1 1'li 114 U dl )I�i l 9� 7 CO , r- .2 Flao a 1I 1 I ti 24X S - 23/402 RECOMIAENDC.D FOR APPROVAL ALL 48 HOURS [B!EFORE YOU DIG - 800 - 424 -5555 .�.Y�. Carwiting Engln"s A. VF, L101 Third AVerM Sulte 900 Q4 py wasfl� OF, ;,aVttla Washing ton 98101 2061 622-5622 Fax G?061 622-8130 CITY OF RENTON Po, mFC24711 '� W4 �aSS'41sT I,1,A N11 I !�ILNT OF PU131 I< WORI S SANITARY SEWER PUMP STATION EXFIItNS „ /.a /bN HUNTER DOUGLAS, INC. RENTON WASHING 70N oesicN�u JBM— DATE, 30MAY97 DRAWN DKR EGR LFN CNECK�D: JDE SCAI -L. AS NOTED Pu.e NnraE: HOUT.DWG JOE MAV 30MAY97 N" r AGC MAV 5/12/97 BY APPN OA TL APPROVI 11 -" SH :C16A- C18 CO , r- .2 Flao a 1I 1 I ti 24X