HomeMy WebLinkAboutS-273202z
0
U)
Z
420
Ld
>
<
:D FINISHED GRADE AT
307 PROPERTY LINE!
z r .
400 -------
13 Q 0.0477 - -- - --
0 01 @ S=0.0319
D I CL. 5
212 LF 8"
I oPOSED ROOF 6�t
'LoJ ice- MH I --
8A
RIM-394.32
INV!IN=388.57 (ICTR)
380
54 DIA SHALLOW TYPE B
RIM=391.36 391.20
INV 114=387.86 387.95 (CTR)
INV OUT=387.76
RlWi=391.2
IE 8"E=386.6 d Co
OP
IE 8"S=385.6
0+00 1+00
AT DRIVEWAY
- - - - --- - - - - - -
2+00
420
z
m,
WATER LIINE_._
PROPOSED
400
54" DIA SHALLOW TYPE B
cla
76.0.96'
)D.vu
ILL]
<
m
m
O)
0
TAV
TAV 1 ".T '--
/LOT 1 LO T 2
Cn
co
<
MfN. FF --,"400.0' MIN FF 401.0
C�
CD 0
r)
LIJ
Lj I
0)
CO
0
LJ
I
00
00
n
Le f
LLJ
> 00
< d)
z
0 Q
m
--6- li!- 397-5
EXIST MH 67
:D z
U)
PROPOSED
PROPOSED DRIVEWAY 94-65'
00
p
RIM- 391.25
0 N 8 '26" VV
0 4
to
IE 8"N=387.70
IE 8"W=387.70
C-4
LD Ln
X X
40' EASEMENT FOR ROADS &
ROADS
S&
IDE�ALKS_NDER REC_ NO.
EASEMENT FOR INGRESS, ffi
& U11LITIES UNDER 2: S;'88'G2'26" E 66-0
IE 8"S=387.70 NEW
UJ: W
5130776E
--REC. NO. 0000000000. 2f
V) EASEMENT FOR INGRESS
(RE-CHANNEL MH)
04
S W11919W, �> EGRESS i U IES UNDER
/ / _.REC_ NO- 0000000000.
p ro
EXIST MH 66
80-00,
Cf), 3
i 0
I-
t o
RIM=111
IE 8" �286.15
E
00
LOT
J_ 00 MIN FF 401.0
j p
4L
0,
IE 8"S=385.6
6" IE 39�7_4
0
Pr
s _E
11LF 8"PVC @S=0.005
Ld
Fr� 1
I
C) 81E
MH 68 54" DIA SHALLOW
TYPE B
0
Cl)
E_ <
STA 0+27.5, 0.5' RT.
EASEMENT FOR
�e z
S > �ip
E-
I PROPOSED_,WATER LINE
- - - - - - - - -
PUBLIC UTILITIES
T 3 E) C
STA 0+00
R!
77
- - - - 1�
UNDER REC. NO.
8707281848.
z
co E
SSMH 68 -A
Z,)r
RIM 394.32
40,
4 0o Z
38&57
11' EASEMENT FOR _00TILI`�11___ ':nMH 69
UNDER REC. NO. 0000000000. RIM = 400-74
NN
13 LF-8"D.I.
V = 395.34
11' SANITARY SEWER ESMT
S = 0.048
9 J.
STATIONING IS ALONG SOUTH PROPERTY
71
LINE FROM INTERSECTION OF UNION AVENUEi
_0
C11
B. `-P 1_586.'D
z
0
U)
Z
420
Ld
>
<
:D FINISHED GRADE AT
307 PROPERTY LINE!
z r .
400 -------
13 Q 0.0477 - -- - --
0 01 @ S=0.0319
D I CL. 5
212 LF 8"
I oPOSED ROOF 6�t
'LoJ ice- MH I --
8A
RIM-394.32
INV!IN=388.57 (ICTR)
380
54 DIA SHALLOW TYPE B
RIM=391.36 391.20
INV 114=387.86 387.95 (CTR)
INV OUT=387.76
RlWi=391.2
IE 8"E=386.6 d Co
OP
IE 8"S=385.6
0+00 1+00
AT DRIVEWAY
- - - - --- - - - - - -
2+00
Z_
I
GRAPHIC SCALE
0 1. 20 b 8D
IN FEET
I inch = 20 ft
1 EXPIRES 2/18/01J
ASBUIL PLANS
S- ?73?O?
420
400
GROUND AT
RIM=400.50 400.74 1 MH 68
INV OUT=396.&3 �395-34 EXIST MH 67,-'
380 RIM=a91z3& 391 201
1" = 20' HORIZONTAL
1" = 10' VERTICAL I
3+00
wwww'U'uno
420
z
m,
WATER LIINE_._
PROPOSED
400
54" DIA SHALLOW TYPE B
Z_
I
GRAPHIC SCALE
0 1. 20 b 8D
IN FEET
I inch = 20 ft
1 EXPIRES 2/18/01J
ASBUIL PLANS
S- ?73?O?
420
400
GROUND AT
RIM=400.50 400.74 1 MH 68
INV OUT=396.&3 �395-34 EXIST MH 67,-'
380 RIM=a91z3& 391 201
1" = 20' HORIZONTAL
1" = 10' VERTICAL I
3+00
wwww'U'uno
m,
INV IN=387.70 'INV ==m 307.�5
3 80 INV OUT=387.60 INV OUT=387.76
1 L1LF 8"PVC @S=0.005
Horton Dennis & Associates, Inc.
E- Ell Consulting Engineers, Planners, and Surveyors
320 SECOND AVENUE SOUTH
WD" KIRKLAND, WASHINGTON 98033-6687
7 PHONE (425) 822-2525 FAX (425) 822-8758
-EXPIRES A I IN 11K [IN !11\ 11 A I P
SCANNED Ll
CT - 81999
.24 N