HomeMy WebLinkAboutS-277701I
�- DATER AND SANITARY SEWER EXTENSION PLAN
N ° INSTALL:
IX. FIRE RE HYDRANT AND 1 -12' TAPPING TEE (MJxFL) p
VALVE TO BE REMOVED
-401 1 -12" GATE VALVE (FLzMJ) p
Yi INSTALL
� 1 6° BLIND FLANGE CONC. BLOCKING
IL CONTRACTOR TO FIELD VERIFY II ( Q
iY O EX HYDRANT TEE VERTICAL AND HORIZONTAL p
W' LOCATION OF IX. WATERMAIN II w CJ�
°Ca -IN+ BY CITY FORCES EX. SDMH#14155
Lu Z 1 -12" CROSS (MJxFL) ON EX. 12" W
co Z O 2 -12" GATE VALVE (FLxMJ)
1 -12" GATE VALVE �MJ) IF =1,.1d E (5a" CMP) C'7
1 -12" NIPPLE IL- =10.09 N (in" 1'MF) -..� r7"
< EL Z _ I C01N1RACTL0, TO FIELD VERIFY 5 LF 12' D.I. 5 LF 12" D.I. dl ; R 2SM2 A74154 Q
Z Z = �..._. _._.. _ 'I a a ?_ ;; _ �i . y __C__ .. .__ .__._�__._ _ _ _ _ _ _- _ _ r ._ -p. .. ..___ -.._ r _ _ _. IE =1.76 N O
....._ .. ..... 1
O co EX. WATER VALVE LOCATION OF IX. WATERMAIN ' IE =1.76 S Z
POWER VAULT CC
(a IX. FIRE HYDRANT S8T30'52 "E 1341.10' 1 -12A GATE VALVE MJ 1-12- GATE VALVE MJ R.P,. BLDG Q
Z IW- Z I o
LX Q 76 LF 72° D.I. I .. .. I EASEMENT TYP. ROW i POPLAR TREES �I n EX. WATER O
LC _....__ , 4 •. U
r - -- 7 7 1 .1. - a MANHOLE
MIRF Lui 385 LF 12' D.I. 1 1 3
Q 12 W Z
3 • x Y1 I c IG I 'q I C�
vfm _j
�N INSTALL I INSTALL., I I J
;f O STa 29 +81.00 EXT. I O 5TA. +2 .6
/ + 1- 12'x6" TEE (MJxFL) - ........._ :
INSTALL:
7 -72° PLUG W 2 TAP O STA. 31 +38.66 I 3
' - AND BLOWOFF ASSEMBLY I 2" DOMESTIC METER 1 -6" GATE VALVE (FLxMJ) INSTALL;
. CON,. BLOCKING 1- 12 "x6" TEE (MJxFL) I AND SERVICE LINE 26 LF 6" D.I. a 22+95.
24 L GATE VALVE (FL1cMJ) 1-FIRE HYDRANT ASSEMBLY 1 -12' TEE (MJxFL)
( I._ PER CITY OF RENTONSiDS. 1 -12" GATE VALVE (FLxMJ) i - -_-
24 LF 6 " D.I. I
RIM =25.1 1 -FIRE HYDRANT ASSEMBLY I SEE DETAIL SHEET CONC. BLOCKING
G --- i
IE =14.76 PER CITY OF RENTON STDS. GONG. BLOCKING
a ° 48 LF 6" SEE DETAIL SHEET 15' WATER
o y I PVC O 2.07. CONC. BLOCKING EASEMENT (TYP.)
p pcu1 z m.22 - ' _ SSMH 3
�'- W W SOLID LOCKING LID
w '
3 � RIM =24.15
E"-I ¢ Q IE =13.80 (6" IN) I I 1L
�! - -- IE =13.70 (8° OUT) INSTALL-
(L + _._ ---- Z
�w
id
E- w as I ' I ) O 16 LF 2.07.6" P/C I 1- 12 "x6" TEE (MJxFL) - Q !�
U mo BUILDING A 1 -6' GATE VALVE (FLxMJ) _._.__ I U
e
E RIM =25.1 ! 26 LF 6' D.I. - - -.. -- ! -- a- "'S a
.5 `w _ F.F. 26.0 1 -FlRE HYDRANT ASSEMBLY
5 E � IE =14.12 PER CITY OF RENTON STDS. , I� Z
E w -I _INSTALL i SEE DETAIL SHEET I JAI ._i I w UJ N
rn•- G o GONG. BLOCKING LLM Z
cN 1- 12 "x6" TEE (MJxFL) I ~ r_+y+
1 -6" GATE VALVE (FLxMJ) I U�Hi J. -B ^X _. U) UJ
7 -12' NIPPLE 9+90.27
aCj ) 1 -12' COUPLING I 1 -12" 22.5• BEND (MJ) i 0 I 4. m
_. 23 LF 6" D.I. I BLOCKING --- "
]<nn ] 43 LF 6" 1 -FIRE HYDRANT ASSEMBLY CONC. BL , W a.
ON
PVC O 2.0% PER CITY OF RENTON STDS. 9%20+27.94 w ___.._
' SEE DETAIL SHEET } I V
Qg ? r RMC 25.1 3- BOLLARDS R PROTECTION I METER W/ BACKFLOW (O [vA
1 IRRIGATION i'.• rr -
a IE =13.67 PREVENTION DEVICE PER Y
o CONTRACTOR TO FIELD VERIFY - - -- I w
�< (
VERTICAL AND HORIZONTAL I CITY OF RENTON STDS. _
LOCATION OF EX. INATERMAIN
' SPRINKLER ROOM
NUS O
SSCO
RIM -25.1 ALL UNTE� PIV,: W/ D.D.C.V. ASSE LY
IE =13.02 - - I .
DB L 2 INSTALL, J t l
A"
n/
r
13 LF n�9(4 g E H 1 (MJxFL)
O 2.O -10" GTE VALVE (FLxMT 4 HANDI TOP SIGN I IX. 25' ESMT. 4
2 NIPPLE 1 h RAMPS N2 COUPLNG
COC. BLOCKING
LD
-TB BE -REMOVED ------------- - - -- -- ----- - - - - ----- --- - -- -_ _ _ _ _ _ - --
PR UN 83 LF 12 "D.I
VERTICAL AND HORIZONTAL -
LOCATION OF EX. WATERMAIN '
IX. WATER MAN 12 W i
--- o ----
______ _____________ ____ ______ ______ _ ___i iE 7Z'CMP= 0.
ADJUST RIM TO _`-- -- 4[. -- -- --- --- - - - -- INSTALL: 7 " _.
OSTa4+ .7
� � m IX. WATER MAN I ._.. EASEMENT (1YP.) 1 -8' 45' BEND (MJ) MP_1 i6� ./J ,��,.: TEL• B0. a 20MH _w
�' I u I GONG. BLOCKING IE 72 "�: j
o ADJUST RIM TO G I INST ^ IF 72" M 1 J IEE pp 6 N _
�N INSTA L• I O STa 41 +87.76 w IE�2.S6j ; ~ c5�
I 1 -12 x10 � TEE MJxFL) IX. 12" WATERMAIN - 156 LF 8" DID- i O z W
53 0 ' NA NE 1- 8'x6" TEE (MJxFL)
p 'E 1 10" GATE VALVE (FLxMJ) TO BE ABANDONED 1 -B" PLUG (MJ) N
1 12" NIPPLE AND ESMT. VACATED /
1 -6" GATE VALVE (FLxMJ) 1� �j5 k'I • W �'
s , 1 -12" COUPLING 10 LF 6' D.I. Q 2 F I - IA c rz
V C CONC. BLOCKING 1-FIRE HYDRANT ASSEMBLY / 9 /� z w
. a• CONTRACTOR TO FIELD VERIFY PER CffY OF RENTON STDS. h 0 I I IX. WATER w N
0 o a I [ VERTICAL AND HORIZONTAL I SEE DETAIL SHEET I �, I +n MANHOLE Q r1 N N p
LOCATION OF EX. WATERMAIN GONG. BLOCKING I / o C WATER o io N co
SPRINK ER ROOM I I / y +o f.• r z ao W
o i W/ D.D C.V. ASSEMBLY
I3 u) to ul
WALL MOUN7�ED IPN® I® I� I® I® I in I® i® I® I® I® I® I® I® I® I I M I M I M I® I I M I® I M I I I ®I 1 +I I `��� �� I' 1 1 ®I I' ( 1 i I- w co O
m W S 2 INSTALL: MATCHLINE SEE SHEET C6 O STA. 19 +0 .07 - sra 40 +00.00, Y v v N 2777oi W SOLID LOCKING LID x xr 0 STAx81 TEE (MJxFL)
RIM =22.5 1 -6" GATE VALVE (FLxMJ)
%IE =12.20 8" IN) 1 -12" NIPPLE p •O
12.10 8" OUT) 24 LF COUPLING 1 -8' CdTE VALVE (FLxMJ)
24 LF 6" D.I.
1-FIRE HYDRANT ASSEMBLY \ CONC. THRUST BLOCKING oKWAS
PER CITY OF RENTON STDS. p� `-5 LF 72' D.I. QP,.4' V l'
SEE DETAIL SHEET N ®TES; ®_L ,0N Q =
GONG. BLOCKING " w
3- BOLLARDS FOR PROTECTION i) THE BACKFLOW PREVENTION DEVICE FOR THE ' 1 -12" GATE VALVE MJ /
CONTRACTOR TO FIELD VERIFY ( ) f
VERTICAL AND HORIZONTAL FIR FLOW LINE NEEDS DE OF THOS TEDL IN E /STER����� �V►
LOCATION OF EX. WATERMAIN '1`SXON CGS br gJ
p 2) INSTALLATION OF NEW WATERMAINS SHALL AL E 0 GOB
Ln REQUIRE INSTALLATION OF POLYETNYUENE WRAP. ra illool FMAPFWVAL EXPIRES
g� Aeo�w
6A -W S"nom CITY OF RENTON
�r FOR APPROVA1.9 /M /fit E>EPAFR-ruera-r ^*= °tJgL_I^ r>o.IKs
BY
o N- s /�s�� WATER AND SANITARY SEWER
EX i ENSSION PLAN
°END __XH oA1e 1 /z1 /9s ENO.
2 REVISED PER CITY REVIEW JGH DKB 1/5/99 H
+" 1 REVISED PER CITY REVIEW JGH DKB 11%/98 AS SCALE 1' =40' FIELD 1
D no�_r'Aae_
4 f Z t yyyy�p s 17i , NO. AEY190N By APPfi. DATE A _C5 -15
h 1e: h': \SUSKYKOJ\ 5911 \LNUINLLKINU \59111WS1.UWU Date /Time: 05/06/1999 0938 Scale: 1 =40 joson Xrefs Z59111S.Z59111T.Z591116, CO. �•�/- 2%1�0� C� -272 ®/ �.n,�® )
SCANNED )CT - B 1999
vr�
"' 01 L L I rim: 66 0
1
L