HomeMy WebLinkAboutS-279306EXISTING YAGI ANTENNA BACKFLOW
i
! PREVENTER
i GFI RECEPTACLE I
% ! FOR RP HEAT TAPE,
WP
GFI
TELEMETRY PANEL
S'
I I
I TELEMETRY PANEL WILL BE PROVIDED BY TS2
OWNER FOR INSTALLATION BY
CONTRACTOR THIS CONTRACT.
ABOVE GRADE I I
ISA SYMBOL LEGEND
LEVEL SWITCH
LEVEL SWITCH
SPDT LIMIT SWITCH
EdLEVEL TRANSMITTER
THERMOSTAT
T'1
NEW ELECTRICAL 6'x3' ELECTRICAL VAULT FOR
SPLICING JACKETED CABLE TO BUILDING WIRE
POWER RACEWAY SCHEDULE
i
RACEWAY DESCRIPTION
DEVICE
TERMINATION
1 1/4" GRC, 4 - #3
SERVICE DISCONNECT
UTILITY METER
Z�
EXISTING CONDUIT, 4 - #3
UTILITY METER
SERVICE DISCONNECT
/s
1 1/4" GRC, 4 - #3
SERVICE DISCONNECT
MANUAL TRANSFER SWITCH
0
1 -#6 BARE COPPER GROUND
SERVICE DISCONNECT
SEWER PIPE BOND
0
1 1/4" GRC, 4 - #3
MANUAL TRANSFER SWITCH
GENERATOR CONNECTION RECEPTACLE
1 /�\
1 1/4" GRC, 4 - 03
MANUAL TRANSFER SWITCH
DISTRIBUTION BLOCK
0
1/2" GRC, 2 - #10, 1 - #10G
DISTRIBUTION BLOCK
DISCONNECT SWITCH
A
3/4" GRC, 3 - #8, 1 - #8G
DISTRIBUTION BLOCK
PUMP CONTROL PANEL
Q
1/2" GRC, 2 -#10, 1 - #10G
DISCONNECT SW! 'CH
480 VOLT HEATER
WEATHERPROOF. CROUSE HINDS MODEL NO.
AREA10486 OR EQUAL
1 1/4" GRC, 2 - #3, 1 - #8C
5 kVA LIGHTING TRANSFORMER
LOAD PANEL
Al
3/4" GRC, 2 - #12, 1 - #12G
TELEMETRY UNIT
BREAKER
A
112" GRC, 2 - #12, 1 - #12G
WET WELL LIGHT
BREAKER
0
1/2" GRC, 2 - #12, 1 - #12G
HVAC CONTROL PANEL
BREAKER
0
1/2" GRC, 2 - #12, 1 - #12G
SUMP PUMP
BREAKER
A
1/2" GRC, 2 - #12, 1 - #12G
VALVE VAULT RECEPTACLE
BREAKER
A
1/2" GRC, 2 - #12, 1 - #12G
VALVE VAULT LIGHTS
BREAKER
A
1/2" GRC, 2 - #12, 1 - #12G
SUMP PUMP
BREAKER
A
1/2" GRC, 2 - #12, 1 - #12G
VALVE VAULT RECEPTACLE
BREAKER
A
1" GRC, 3 - #12, 4 - #14, 1 - #12G
MOTOR NO. 1
MOTOR STARTER
A
1" GRC, 3 - #12, 4 - #14, 1 - #12G
MOTOR NO 2
MOTOR STARTER
A
1 -1/2" GRC, PUMP 1 JACKETED CABLE
MOTOR NO. 1
MOTOR STARTER
A
1-1/2" GRC, PUMP 1 JACKETED CABLE
MOTOR NO. 2
MOTOR STARTER
0
1" GRC, 6 - #14
FLOAT SWITCHES
TELEMETRY PANEL
A
1 -1/2" GRC, JACKETED CABLE
LEVEL TRANSDUCER
TELEMETRY PANEL
SHALL COORDINATE WITH PSE.
1" GRC, 8 - #12, 4 - #12G
VALVE VAULT DEVICES
TELEMETRY PANEL
IA
2" GRC, 3 -FLOAT CABLES
FLOATS
TELEMETRY PANEL
A
ANTENNA CABLE
TELEMETRY RADIO
ANTENNA
1/2" GRC, 2 - #12, 1 - #12G
DEHUMIDIFIER
BREAKER
3/4" GRC, 2 - #12, 1 - #12G
HOTBOX RECEPTACLE
BREAKER
C
1" GRC, 12 - #14, 1 - #12G
PUMP CONTROL PANEL
TELEMETRY PANEL
wW#o -p1` -tpp `
PUMP CONTROL PANEL OE ( AM t vr1
i
- - -
DEVICE OR EQUIPMEN i TERMINAL
I C
- - - -- - -
F EXISTING POWER POLE
15A 15A
3P'.
CONNECTIONS TO TELEMETRY
3P',
15 AMP
480 VOLT WIRING
MR ���, �-j -
I rrR
3F
J - SFTP
MR
TRANSIENT VOLTAGE SURGE
©
SERVICE DISCONNECT SWITCH
C
V,or
T'{
ETOL
I
OLJ
30 AMP FUSE BLOCK SUPPRESSOR - ORION MODEL
ORN -3Y 277/480C.
�- GENERATOR CONNECTION RECEPTACLE - 500V,
GFI
? N,
NEW EQUIPMENT
120VAC, 20 AMP WITH GROUND PRONG (FOR SUMP
- 100A, 4-POLE 3 -WIRE, THREADED CAP,
- ' WP
PUMPS AND DEHUMIDIFIER). DUPLEX RECEPTACLES
LOCATED IN DRYWELL.
\
WEATHERPROOF. CROUSE HINDS MODEL NO.
AREA10486 OR EQUAL
r
SWITCH, 120VAC, 20 AMP
FUSE
L
LIGHT FIXTURE
HEATER LOCATED IN VAULT
HEATER DISCONNECT SWITCH
Sr
UTILITY METER ENCLOSURE AS
APPROVED BY PUGET SOUND ENERGY
N
\I
DISTRIBUTION TRANSFORMER
0
480 VOLT DISTRIBUTION BLOCS( ©
=
I NEW CONDUCTORS IN EXISTING AND
I I� KWH
I a ' \ 100A
-
j
430 VOLT 'y
PFR -
PHASE FAIL RELAY
PROPOSED 1 1/2° CONDUIT. CONTRACTOR
\ N 3P
MR -
MOTOR RUN
NEW 480/277 SERVICE TO
HEATER 0 30A
OL -
MOTOR OVERLOAD
SHALL REMOVE OLD CONDUCTORS.
- _
L 1 Y
SFIL
- SEAL FAIL INDICATOR LIGHT
REPLACE EXISTING 240V, 3
Z 3P
MOIL
- MOTOR OVERTEMP INDICATOR LIGHT
APPROXIMATELY 120 FEET OF CONDUIT IS
EXISTING.
- -` K
Q
_ _
f
PHASE SERVICE CONTRACTOR.
S
OC -
3
1
SHALL COORDINATE WITH PSE.
_
g` MANUAL
STRANSR
([ 2
I
i
PUMP CONTROL PANEL OE ( AM t vr1
i
- - -
DEVICE OR EQUIPMEN i TERMINAL
I C
- - - -- - -
120 VOLT WIRING
15A 15A
3P'.
CONNECTIONS TO TELEMETRY
3P',
15 AMP
480 VOLT WIRING
MR ���, �-j -
I rrR
3F
J - SFTP
MR
SFII ,
yFTP�
I NO
J
3
4 X
V,or
T'{
ETOL
GFI
OLJ
M
HOC
GFI
DEDICATED SINGLE OUTLET GFI RATED RECEPTACLE,
ELECTRICAL VAULT
E fS
CLASS 1 DIVISION
1 AREA
CONDUIT PENETRATIONS
TO VAULT AND WET
WELL PROVIDE
INSULATED PLASTIC
BUSHING. THOMAS AND g
BETTIS #226 TYPICAL f
WET WELL, VALVE VAULT,
AND HAND HOLES �Tr
T•.
s
100A
3P
DISCONNECT SWITCH '
0
i
6! O
F
30A
3P
JJ LIGHT TRANSFORMER 5kVA, 1
PHASE 480V PRI /120 /24OVSEC
LIGHT SWITCH ( 20A 20A 0
20A 2 0A � 20A -
--T 20A 20
- 20A 20A -
EYS
20A o20A -
20A 20A
- LOAD PANEL
ELECTRICAL VAULT
WATERPROOF
CABLE SPLICE J J
(TYPICAL) LEVEL TRANSMITTER BELLOWS
ATTACHED TO SIDE OF VAULT PER
MANUFACTURE'S RECOMMENDATIONS
CLASS 1 DIVISION
1 AREA
ii
T WELL LS3 -.
FLOATS
LS2
LS1
L o '
,HP,,'1/
PUMP # 1 PUMP # 2
EQUIPMENT LOCATED ON
TALBOT ROAD SOUTH.
OWNER TO APPROVE
LOCATION OF EQUIPMENT
O BEFORE INSTALLATION
R
``100A NEW SERVOS
DISCONNECT SWITCH
iGi 1
J 'o-
J
BELOW
GRADE
#6 BARE COPPER GROUNDING ELECTRODE
CONDUCTORS TO GROUND RODS PER N.E.C.
J
u
M1 .� T
=
LS4 LS5
=GFI
' CHECK VALVE LIMIT QT - -T -
I '
I ZS1 SWITCHES. (TYPICAL) O
f -
- I
I � Z52
o
GFI EXHAUST FAN MOTOR I ,,
WIP
--
DEHUMIDIFIER M % M - L -- 6, - -GFI - - -'�
1000 W, 120V ` --
I
_GFI TS1 \.
WIFb
WET WELL TRANSDUCER SUMP PUMP MOTORS (TYPICAL)
NEW HVAC CONTROL PANEL. SEE DWG.
SAR,2793 N0. E1 FOR CONTROL LOGIC
F�R 2 `
SEE LEGEND ON DWG NO. TE3 FOR DESCRIPTIONS I
FLOOD SWITCH (TYPICAL OF 2) 1 R.��
S aF •sg�NQ%i
REVISED TO CONFORM � F r
TO CONSTRUCTION RECORDS
22513
MARK MILLER 07/18/00 acisxs86 °tir� SIGNED:
RH2 ENGINEERING INC. DATE tOu 11/11/99 I
EXPIRES 71/3/01
a '
r
m '
0
y M
r
� I
m Iro
9 e
z
-� c
ELECTRICAL SYMBOL LEGEND
- - -
DEVICE OR EQUIPMEN i TERMINAL
- - - -- - -
120 VOLT WIRING
_
CONNECTIONS TO TELEMETRY
480 VOLT WIRING
- -_ W_P
DUPLEX OUTLET RECEPTACLE, 120VAC, 20
_
AMP WITH GROUND PRONG (WATERPROOF
GFI
WHERE INDICATED WITH WP) - GFI RATED
M
3 PHASE MOTOR
GFI
DEDICATED SINGLE OUTLET GFI RATED RECEPTACLE,
120VAC, 20 AMP WITH GROUND PRONG (FOR SUMP
- ' WP
PUMPS AND DEHUMIDIFIER). DUPLEX RECEPTACLES
NOT ACCEPTABLE.
MAGNETIC BREAKER ONLY
SWITCH, 120VAC, 20 AMP
FUSE
L
LIGHT FIXTURE
Sr
N
SOLID NEUTRAL
M
SINGLE PHASE MOTOR
=
GROUND
®�
EYS EXPLOSON PROOF CONDUIT SEAL FITTING
ABBREVIATIONS LEGEND
PFR -
PHASE FAIL RELAY
TELEMETRY WIRING
MR -
MOTOR RUN
OL -
MOTOR OVERLOAD
EQUIPMENT /DEVICE ENCLOSURE
SFIL
- SEAL FAIL INDICATOR LIGHT
MOIL
- MOTOR OVERTEMP INDICATOR LIGHT
J
JUNCTION BOX SIZED PER NEC
RTM
- RUN TIME METER
OC -
OPERATION COUNTER
J
u
M1 .� T
=
LS4 LS5
=GFI
' CHECK VALVE LIMIT QT - -T -
I '
I ZS1 SWITCHES. (TYPICAL) O
f -
- I
I � Z52
o
GFI EXHAUST FAN MOTOR I ,,
WIP
--
DEHUMIDIFIER M % M - L -- 6, - -GFI - - -'�
1000 W, 120V ` --
I
_GFI TS1 \.
WIFb
WET WELL TRANSDUCER SUMP PUMP MOTORS (TYPICAL)
NEW HVAC CONTROL PANEL. SEE DWG.
SAR,2793 N0. E1 FOR CONTROL LOGIC
F�R 2 `
SEE LEGEND ON DWG NO. TE3 FOR DESCRIPTIONS I
FLOOD SWITCH (TYPICAL OF 2) 1 R.��
S aF •sg�NQ%i
REVISED TO CONFORM � F r
TO CONSTRUCTION RECORDS
22513
MARK MILLER 07/18/00 acisxs86 °tir� SIGNED:
RH2 ENGINEERING INC. DATE tOu 11/11/99 I
EXPIRES 71/3/01
a '
r
m '
0
y M
r
� I
m Iro
9 e
z
-� c