Loading...
HomeMy WebLinkAboutS-279602i T 1 G D T L� 0 41( Q W J -j U 1 IZ Q Z Z = LLJ -J W w = cn ci i C 1 4 C 0. cc � p C TAJ N T�pppp� r O R HIGH POINT ELEV - 407.49 HIGH POINT STA = 0 +44.27 PVi STA - 0 +5 I E G PVLEV = 408.02 A.D. _ -8.95 0 +00 1 +00 2 +00 3 +00 PROPERTY LINE ° FUTURE 6'" BUILDING SEWER PIPE BUILDING SEWER ? 2 "x 4 " STUD SERVICE MARKER PAINT UPPER -TEE WITH 6" SIDE OUTLET J I PORTION WHITE ANS STENCIL ON SIDE WORDING "SEWER" WITH 3" HIGH BLACK LETTERS. w AND #6 WIRE SEVER WRAPPED AROUND THE STUD AND W'• _ anc cc R un w n a o EXTENDED TO THE TOP OF THE STUD. K UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS WHEN CONNECTING NEW SIDE SEWERS TO EXISTING MAIN. VTRIFIED CLAY, PLAIN AND REINFORCED CONCRETE, D1 PIPE AND C1 PIPE SEWER MAINS ARE TO BE CORE DRILLED 60" ALLOWABLE MAX. FOR CAST IRON PIPE OR DUCTILE IRON PIPE. t 1:3:5 MIX khSY��NG CONCRETE BLLOCKING OVOC� 2% MIN SLOPE HORIZONTAL 6" SIDE OUTLET TEE SEWER MAIN 6'" MIN. SEWER MAIN f= ONCRETr O(8[IND N J G OF TEE AT PAIN OVER 25 ]YYP,IP, I al0 cr R FVATION �� STANDARD SIDE SEWER INSTALLATION NOTE: UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3 -5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. STANDARD SIDE SEWER INSTALLATION NOT TO SCALE m MORTA FILLET MANHOLE FRAME AND COVER SEE DRAWING BR29 ADJUSTMENT (4" MIN.) CONE RUBBER GASKETED JOINTS IN ACCORDANCE WITH ASTM C -443 STEPS - 3/4" DEFORMED BAR STEPS SHALL BE INCLUDED CONCRETE RISER BY PIPE INC., OR APPROVED EQUAL. MAX. PIPE SIZE - 21" I.D. LADDER -STD. ALUMINUM OR GALVANIZED STEEL CONCRETE SHELF PRECAST BASE SECTION OR CAST IN SHELF. SANITARY MANHOLE TYPICAL DETAIL NOT TO SCALE SgliPE,' Oy ILA NOTES: 1. STEPS TO BE 3/4" 0 DEFORMED BAR GALVANIZED SAFETY a vi ° STEPS OR EQUAL. L� t1� 2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED. 11332 3. CASTING TO BE PER DRAWING BR29. 1 gryg491 4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST S70NAL CONCRETE. 5. ALL JOINTS SHALL BE GROUTED. �- F5 6. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR rEmu 11/30/00 SURFACES, INCLUDING CHANNELING, COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC- CONSEAL OR APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE. 7, RUBBER GASKETED JnINTS SHALL BE IN CONFORMANCE WITH ASTM C -443. RECOMMENDED B. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE FOR APPROVAL DIAMETER OF THE LARGEST PIPE. 'I 9. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK BY K�1kVl[�� �/Z1199 ADAPTOR, KOR -N -SEAL BOOTS OR APPROVED EQUAL. BY BY AVOID CUTTING UNDERGROUND UTILITY LINES. IT'S COSTLY NOTE: � NOTE: Cal EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY. bbefore SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE efore y ®u EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER- GROUND GROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO il. REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN ®4 HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES 1- 800 - 424 -5555 NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION. UNDERGROUND SERVICE (USA) CALL BEFORE YOU DIG: 1k800- 424 -5555 �- 279602- SCANNED OCT - B 1995 S 1 I .2 4