HomeMy WebLinkAboutS-281404R�
n
r
VJ f
W
N ati
a�
Fz
O > o
m o �
� of
� o
9 �
Ln
W
zy
°V
Li 0 in
Q� J
J
0_ F-- Lii
r
H D
0 O LL1
= O J
U) Q
i af g-
Q LLj I
(n ry
Ld
Ld
J
cr)
ry
ry
z
Q
+% O
o�
u1 0
O Q 0E
E 3¢
� LJ
E- a a
w �
_mo
E
E
� E
o �
aCD
o
o ��o
II w B °yamy
MORTAR
FILLET
MANHOLE FRAME AND COVER
W /LOCKING LID
SEE DRAWING BR29
ADJUSTMENT (4" MIN.)
RUBBER GASKETED JOINTS
IN ACCORDANCE WITH ASTM C -443
STEPS - 3/4" DEFORMED BAR
STEPS SHALL BE INCLUDED
CONCRETE RISER BY PIPE INC.,
OR APPROVED EQUAL.
MAX. PIPE SIZE - 21" I.D.
LADDER STD. ALUMINUM
OR GALVANIZED STEEL
CONCRETE SHELF
PRECAST BASE SECTICH
OR CAST IN SHELF.
6" MIN. I _
i- ---- -{ , 6" MIN. (TYP)
SANITARY MANHOLE TYPICAL DETAIL
NOT TO SCALE
NOTES:
1. STEPS TO BE 3/4" 0 DEFORMED BAR GALVANIZED SAFETY
STEPS OR EQUAL.
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS
ARE INSTALLED.
3. CASTING TO BE PER DRAWING BR29.
420 4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST
CONCRETE.
5. ALL JOINTS SHALL BE GROUTED.
6. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR
SURFACES, INCLUDING CHANNELING, COATED (SEALED)
WITH A HIGH SOLIDS URETHANE COATINC;
WASSER MC- CONSEAL OR APPROVED EQUAL;
COLOR OF COATING SHALL BE WHITE.
7. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE
WITH ASTM C -443.
8. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE
DIAMETER OF THE LARGEST PIPE.
9. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK
ADAPTOR, KOR -N -SEAL BOOTS OR APPROVED EQUAL.
60" ALLOWABLE MAX.
FOR CAST IRON PIPE
OR DUCTILE IRON PIPE.
1:3:5 MIX p5
CONCRETE }
BLOCKING �1-2% oL 6 "' SIDE OUTLET TEE MIN SLOPE
' SEWER MAIN
6" MIN. HORIZONTAL
CONCRETE BLOCKING AN /J
OF TEE AT MAIN OVER 25 � SEWER MAIN
ELEVATON
- -- 410 TYPI A CIDE SEWER FVA710N
STANDARD SIDE SEWER INSTAL! eTON Z
T
d
d
z
0
6" BUILDING SEWER PIPE
w L' nE
no
6e WAS;! /�;` ?T�
V.F C
o U) O R 11332
``-- OA'41 LANOS
EXPIRES It 3 W
cSL ?,ANS ARE. "AS- BUILT'
vNC 111E INFORMATION SHOWN
4CCURATE! Y REFLECTS EXISTING
MELD CONDITIONS, AS OF THIS
DATE 12fo .�`(
-1 LL LIAM�OLMB ? RG °LS' 133: .
o w`vO Z7 - 281¢
SANITARY SEWER NOTES AND SPECIFICATIONS
1, ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE
STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON AND THE
LATEST EDITION OF THE WSDOT /APWA STANDARDS AND
SPECIFICATIONS.
2, THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE
LIMITED TO 8:30 AM TO 3:.30 PM ON WEEKDAYS UNLESS OTHERWISE
APPROVED IN WRITING BY THE TRANSPORTATION DIVISION AT 277-
6222. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE
APPROVED BY THE TRANSPORTATION DIVISION 24 HOURS IN ADVANCE.
THE POLICE DEPARTMENT, FIRE DEPARTMENT AND 911 SHALL BE
NOTIFIED 24 HOURS IN ADVANCE.
3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH "STANDARD
SPECIFICATIONS FOR MUNICIPAL PUBLIC WORKS CONSTRUCTION"
PREPARED BY WASHINGTON STATE CHAPTER AMERICAN FPUBLIC WORKS
ASSOCIATION, LATEST EDITION (APWA) AND THE CITY OF RENTON
STANDARD SPECIFICATIONS.
4, ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE
AND IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY THE
FRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR
DISTURBANCE.
5. A PRE - CONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL
BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION, IT SHALL BE
THE CONTRACTORS RESPONSIBILITY TO SECURE ALL NECESSARY
PERMITS PRIOR TO STARTING CONSTRUCTION (INSPECTION WILL BE
ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON). IT
SHALL BE THE CONTRACTORS RESPONSIBILITY TO NOTIFY THE CITY
INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL
CONSTRUCTION.
6. CONTRACTOR IS SOLELY RESPONSIBLE FOR THEM MEANS, METHODS
AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS
AND OTHERS ON THE CONSTRUCTION SITE
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO
OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY
CONSTRUCTION.
8. PLANS APPROVED BY THE CITY OF RENTON, DEVELOPMENT
SERVICES DIVISION, SHALL TAKE PRECEDENCE OVER ALL OTHER
PLANS.
9. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE
WHENEVER CONSTRUCTION IS IN PROGRESS.
10./ THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON 14TH AN
AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM WHICH HAS BEEN
STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR
LICENSED PROFESSIONAL SURVEYOR.
11. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE
PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES,
MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER, TO
95% OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND
FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE
SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE:
SHALL BE THE SAME AS DESCRIBED.
12. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING
TRAVELED ROADWAY SHALL BE BACKFILLED WITH CRUSHED ROCK AND
MECHANICALLY COMPACTED. CUTS INTO THE EXISTING ASPHALT SHALL
BE NEATLINE CUT WITH SAW IN A CONTINUOUS LINE, A TEMPORARY
MIX PATCH MUST BE PLACED IMMEDIATELY AFTER BACKFILL AND
COMPACTION. A PERMANENT HOT MIX PATCH SHALL BE PLACED WITHIN
10 DAYS AND SHALL BE PER CITY OF RENTON CURRENT STANDARDS.
134. DATUM SHALL BE CITY OF RENTON U.S.C. AND G.S.
14, ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR
OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT
FOR THE PREVENTION OF ONSITE EROSION AFTER THE COMPLETION 0-
CONSTRUCTION.
15 ALL PIPE AND APPURTENANCES SHALL BE LAID ON !- PROPERLY
PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 02.3(1) OF
THE CURRENT STATE OF WASHINGTON STANDARD SPECIF,CATIONS FOR
ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY
STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD AND
BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING
OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL
AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING
MATERIAL TO UNIFORM GARDE SO THAT THE ENTIRE LENGTH OF THE
PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE.
PIPE BEDDING SHALL BE PEA GRAVEL 6" ABOVE AND BELOW THE
PIPE.
16. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC)
RUBBER GASKETED ASTM 3034, SDR 35, OR DUCTILE !RON CLASS 50.
17, IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES
AND MAXIMUM 18 INCH ABOVE FINISHED GRADE. IN PAVED AREA,
COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING,
PROPERTY LINE 4S qk 2146A S
FUTURE
BUILDING SEWER
DATUM ELEV
405.00
2 "x 4" STUD SERVICE MARKER PAINT UPPER
TEE WITH 6" SIDE OUTLET PORTION WHITE ANS STENCIL ON SIDE
WORDING "SEWER" WITH 3" HIGH BLACK LETTERS.
AND $6 WIRE WRAPPED AROUND THE STUD AND
TO THE TOP OF THE STUD.
EXTENDED
6" SIDE SEWER AND BUILDING SEWER
S�jUPE
UNLESS
OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST
e.�, pF WASk7
IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS
WHEN DONNE TING NEW SIDE SEWERS TO EXISTING MAIN.
VITRIFIED CLAY, PLAIN AND REINFORCED CONCRETE, DI PIPE AND CI
PIPE SEWER MAINS ARE TO BE CORE DRILLED
NOTE:
'.°p ll332� ,Cy4
O 2
UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY
gtONAL �G1
LINE OR 3 -5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LnWER,
EXPIRES 11/30/00
STANDARD SIDE SEWER INSTALLATION
NOT TO SCALE AVOID CUTTING UNDERGROUND
NOTE:
RECOMMENDED
UTILITY LINES. IT'S COSTLY
EXISTING UTILITY LOCATIONS
SHOWN HEREON ARE APPROXIMATE ONLY
FOR APPROVAL
Call
IT SHALL BE THE CONTRACTOR'S RESPON5IRILITY TO DETERMINE THE
EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER -
BY
ore Ou
before 1 ef 7
GROUND UTILITIES
REPRESENTATION IS
PRIOR TO COMMENCING CONSTRUCTION. NO
MADE THAT ALL EXISTING UTILITIES ARE SHOWN
By
V4 _r.
199 vU�
HEREON THE cnlG!nlErp
NOT SHOWN OR UTILITIES
CALL BEFORE
ASSUI „2S INC) RESPONSIBILITY FOR UTILITIES
NOT SHOWN IN THEIR PROPER LOCATION.
YOU DIG; 1 -800- 424 -5555
BY
UNDERGROUND SERVICE (USA)
281VOa
SCANNED WAR 3 0 200C