HomeMy WebLinkAboutS-283203li -7 /2' x 13 -1 /2" CONCRETE TE METER �I'�IN UNIMPROVED RIGHT OF WAY, BIIX WITH 3/16' STEEL DIAMOND PLATE IN METER BOX AT COVER COUAL. TO FOG TITE METER vI PROPERTY' LINE. t SEAL CO ID METER BI1X. SIDEWALK WATER METER TO BE SUPPLIED BY THE CITY mr r TYPE 'K' SOFT � -- COPPER TUBING _ FORD COPPERSCTTEF, VH 132 -15W (FOR 5l8' x 3/4' METER) CAST IRON OR VH 174 -ISW tFOR 1• M':TER) , DUCTILE IRON / LOOP DOWN TO CENTERLINE BOTH INLET ADD OUTLET WITH PACK JOINT WITH GRIPPER. vATERMAIN pF WATER MAIN TO PROVIDE ON PADLSCV GUTL WINGS ON KEY VALVE SINGLE CHECK VALVE / SLACK IN COPPER SERVICE ON OUTLET. JJ /J LINE TO METER ALL PACK -JOINT FITTINGS SHALL BE WITH GRIPPER CORPORATUON STOP. FORD TAPERED IF SERVICE LINE TO HOUSE 1S TO BE THREAT' (CC). PACK JOINT (3/4' F3000) INSTALLED IN THE FUTURE INSTALL (1" Fi0001 FORD C14 -33 OR 44 1I0T u COMPRESSION COUPLING 3/4' OR I' GALVANIZED PLUG ,3/4"2 1" WATER SERl, ICE NO SCALE FLOE HYDRANT SHALL BE COREY -TYPE EQUAL TO IDwA F -5110 OR COUPRF-R9OM TYPE SUCH AS CLOW MEDALLION: M ✓r H 929 pun ue=CEM SUPER CENTU...,,.. GW Will 6- MECIiANICAL =NT INIET NTH LUGS 5-1/4' MAIN VALVE OPENING_ TWO 2 -1/2- HOSE.CONNECTIWNS NATIONAL STANDARD THREADS 4- PUMPER CONNECTION CITY OF SEATTLE THREADS MATH A STORTZ ADAPTOR, 4- SEATTLE THREAD X S. STORTZ, ATTACHED VAIN 1/8- STAINLESS STEEL CABLE, 1 -1/47 PENTAGON OPERATING NUT, FIRE HYDRANT TO BE — TO 20' PAINTED VAIN TWO COATS OF PAINT, PRESERVATIVE OR 12- BEHIND BACK OF SIDEWALK THAT IS ADJACENT TO CURB PAINT Nn 43-655 SAFETY YELLOW OR APPROVED EQUAL PUMPER CONNECTION TO FACE ROADWAY ASSEMBLY FOR 4 -1/2- TRENCH, MAX 4'-1 • FIRE HYDRANT EXTENTION TO BE USED IF REQUIRED. MIN 2 -� RAISED PAVEMENT MARKER TYPE 88 AB STIMSONITE TWO -WAY BLUE" TWO -PIECE CAST IRON VALVE BOX. EQUAL TO OLYMIC FOUNDRY CO. STANDARD B' TOP SECTION WITH REGULAR CONCRETE BLOCKING BASE SECTION LENGTH TO FIT. Q =s CONCRETE BLOCKING LCAST IRON TEE. WITH 6' FLANGE SIDE OUTLET. 6- GATE VALVE (FL X MJ) EQUAL TO MUELLER CD. A- 2380 -16 —6' DUCTILE IRON PIPE, CLASS 52 CEMENT LINED, LENGTH TO FIT TWO 3/4- 16' x 8" x 4" MINIMUM STEEL TIE RODS. SEE STD DETAIL FOR TIE RODS CONCRETE BLOCK 7 CU. FT. MINIMUM WASHED GRAVEL PASSING 1 -1/2- AND RETAINED ON 1/4" MESH FOR DRAIN. FIRE HYCIR�. IT I FTAIL NO SC.ALL r WATER MAIN / IF ADDITIONAL ADJUSTMENT IS REQUIRED, INSTALL 2 -2' CLOSE NIPPLE AND 2 -2' 90' BEND, SCREWED AT THIS POINT. FIELD LOCATE 2' CLOSE NIPPLE F - - y�CONCRETE METER BOX I I 2" CLOSE NIPPLE 2' 90°ELBOW '2' 90 ° ELBOW dal a 2' GALVANIZED PIPE AS REQUIRED CONCRETE BLOCKING PLAN TWO PIECE CAST IRON VALVE EOU:.L TO OLYMPIC FOUNDRY CO. STANDARDS* TOP SECTION, WITH /- GROUND LINE //- CONCRETE SIDEWALK REGULAR BASE SECTION LENGTH / TO FIT- i PROPERTY LINE T-F T -D•' niN. 6• -0'• -1 FUTURE 6" BUILDING SEVER PIPE I BUILDING SEWER ? 2"x 4" STUD SERVICE MARKER PAINT UPPER TEE WITH 6" SIDE OUTLET PORTION WHITE ANS STENCIL ON SIDE „ WO0RDING 'SEWER' WITH 3" HIGH BLACK LETTERS. 6" SIDE SEWER AND BUILDING SEWER AND 16 WIRE WRAPPED AROUND THE STUD AND o I EXTENDED TO THE TOP OF THE STUD. a UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS WHEN CONNECTING NEW SIDE SEWERS TO EXISTING MAIN. 60" ALLOWABLE MAX. VITRIFIED CLAY, PLAIN AND REINFORCED CONCRETE. DI PIPE AND Cl FOR CAST IRON PIPE PIPE SEWER MAINS ARE TO BE CORE DRILLED OR DUCTILE IRON PIPE. lo.s nix /p / Yt K�JG BLOCKING Ha zs �Y,p'1"•G0.ESf` co`4 zz nm garc HORIZONTAL 6" SIDE WTLET TEE B.. nIN -SEWER MAIN SEWER MAIN (Q CRE:FE BLOCKING ANGLE DF'TEL AT MAIN OVER 25 TYPICAL SIDE SEWER ELEVATION ELEVATION NOTES, UNLESS, OTHERWISE SHOWN ON PLAN, SIDE SEVER, SHALL HAVE A MINIMUM 5' COVER AT PROPERTY LINE OR -3 -5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. TYPICAL SIDE SEWER INSTALLATION °�• - - -G I 2 -1/2" NST (HOSE) ?" GATE VALVE, SCREVED BLOW -UFF HYDRANT EQUAL TO 2" GALVANIZED 478 KUPFERLE FOJNDRY CO PIPE 12" LONG 2".2'x2' TEE 2" CLOSE NIPPLE BETTEEN 2" CLOSE NIPPLE TEE AND 90'ELBOW. BETWEEN CAP OR PLUG ` AND 2" 90 2" 9L ELBO90"L BOW INSTALL 4 MIL POLYETHYLENE 2' GALVANIZED PIPE PLASTIC COVER OVER WASHED - o - - °8 18" LONG GRAVEL. CUT HOLE FOR PIPE _ o o° - o9popo °oo 2' CAP WITH 1/8' 10 CU FT. WASHED GRAVEL PASSING °o x-`°o °-0�4 TAP FOR DRAIN I -1/2' AND RETAINED ON 114' MESH s o� FOP DRAIN ELEVATION PERMAP,W N T 2 Bf_r�, r (= [Vi BI_, NO SCALE q/1ol'660'! AS BUILT 7'6:0 -4YO -28dZ ® - - - NO SCALE � ST \ - LOT LOT Z All � \ LQT 4 j LOT 3 S VICINITY PLAN NO SCi;LE -- �1 yl� j t�I II-z i' I 31 f 3i PROJECT DATA APPLICANT/ DEVELOPER SURVEYOR ENGINEER TOTALAREA NUMBER OF LOTS J & J CONSTRUCTION 2509 Aberdeen Ave NE Renton, WA 98056 (425) 255 -2362 CONTACT- JIM JACQUES JAMES CRONES JAMES E. HAYNES, P -E- 37234 22ND AVE SO FEDERAL WAY, WA 98003 (206) 661 -6794 0,75 ACRES 4 AO%l *Am 240 A ww+ LOCATION DESCRIPTION A ?'m � "MW *1#45 4? Olvil THE WEST 130' OF THE WEST OF THE EAST % OF THE WEST % SOUTHEAST Y. OF SECT 3-23 -5 F JAMES E HAYNES PE 37234 22" AVENUE SOUT4 FEDERAL WAY, WA 98V03 (253) 661 -6794 O Z 6� z CJ ggN e PT F9 I t2i f4 Zy Z' +, n _z r n Z C V7 rTl_ O S ::E D X D m D F- (1) SCANNED MAR 3 0 2000 /-I 1 R - ac;ANNED SEP 13 2002 I A 0 y -c d 3d O ?'- N W N u V