HomeMy WebLinkAboutS-283301n
Cb
9
i
a
M -
N
Al a z
l _ ° >
N x3 0
0
1 aQ A
a W W
m o
m o
� I
c r7
8 co
rn °
W
O Q
Q Q Q_
CL
ry W
O
= O W
CP T (r)
< LLJ
J
Z J Q
W Q
CL
nI0
�i
0
o Zm
CONIC. MON. IN CASE
CITY OF RENTON CONTROL MON.
NO. 1886 - REF. SURVEY IN
VOL. 118, PG 232 (S.W.
CORNER, SECTION 32)
/1& 1
Ww,p- 27 -28??
3�
SITE , 33
N88-50'07"W
Z 20
I
6
33
K N I 2I �Q
N 8'43'45 "W (HELD FOR BASIS OF BEARING N I 3
FOUND CONIC. N88'41'24 "E (NAC 83/97) FOUND CONS.
MON. IN CASE N. 38TH' MOH. IN CASE X33
VISITED 2/8/99 664.08' (MEAS.) VISITED 2/8/99 I
664.15' (V. 118, PG. 232) I
n� i II
ro
N z
CONIC. MOH. IN CASE
S v CITY OF RENTON CONTROL MOH. I
z 1334.24' NO. 266 - REF. SURVEY IN V.
(NAD 83/91) 2633.59' 118, PG. 232 (S. 1/4 CORNER,
SECTION 32) I EX GRAVEL (DRIVE —� 33 cn I oL� s�ioo220
.. r EX GRAVEL DRIVE [yl7d�ro�—
J I SCALE 1° = 20'
� I I
�—_EX 5' WOOD RAIL FENCE it �� % EX. HOUSE
I \ i
7 SIDE WAL1.. RAMP
EXIST. SSMH
JI � _ RIM= 125.67
INV= 118.28 (N)
\ ti INV= 118.34 (S)
LOT 6 /y/ � CEDAR HEDGE F
� MIN. F.F.= '
�9\ I
t \ \ 128.00 INV72276
_ LOT 4 LOT 3 LOT 2
- MIN. F.F.=
127 10 126.50 MIN. F.F.= MIN. F LOT 1
\z 127, 1F, 126.00 725501 01
1
I I
z EX. HOUSE H�
6* SIDE SEWER I EX. CONC. �• -_ �/
O 200% MIN. .p0 DRIVE
t
15' SANIT RY . , .
APPROS. LOCATION OF E'ISRNG
LOT INV 2 +03 — EASE E T SANITARY SEWER SERVICE
r : \ STA. 2 +53 INV 121.1 STA. 1 +53 �� 33
•�� r \ INVa121 42 r I INV- 120.61 CEDAR HEDGE ;
_STA.1ii7.'00 0 5{,T `a_ ,,.._.' t
MIN FF gr — — — �.
72800\ i INV12115 N' - -EX 6 CU — -- — — -- —
INV =121.32'(0 6- IN) i .. E.ND RT - . - . - — _ _ —
INV= n' _ - o° 283 =8 D.I. CL 50 O 0;15SY'°
E izslo
12242 _ -
-
- _-- xi — - SSMH/1
-- — ._ -.,... -.d. .. _ _ RIM - 126.45± (MATCH
7EX. CONSTRUCT �6' SEXIST.)
I 358 27' + I —
WIRE FENCE I CEDAR FENCE ON 26 I INV 119.76 (E)CIST, VERIFY
\\ OR1�WpY PROSES DETAIL' — 7 EX. CON4ETE DRIVEWAY I 3 PRIOR TO COSLT.) SONG. I INV = 119.88 (W NEW)
X I SAWCUT PAVING &
REPLACE PER DETAIL, TYP.
\
NOTE
STENCH AND STREET OVERLAYS SHALL
1. ALL BE PER THE CURRENT CITY OF RENTON TRENCH
RESTORATION AND STREET OVERLAY
REQUIREMENTS.
2 POTHOLE EIOSTING UTILITIES PRIOR TO
CONSTRUCTION TO VERIFY HORIZONTAL AND
VERTICAL LOCATIONS
� 301
I a N I
Uz-
I II y I
I 33 I
I I
I I N I
33 I I gUP
OE w
I I I ti� ^4' d"ca
am z�
33
II 3 11
1
33 I `SIGNAL
`� EXPIRES 11/30/00
I i
AVOID CUTTING UNDERGROUND NOTE;
UTILITY LINES. IT'S COSTLY
RECOMMENDED /� EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY.
FOR APPROVAL ■ _��B IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE
V EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER-
GROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO
BY _ t L before y ®u REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN
.7�� �: a. HEREON. THE ENGINEER. ASSUMES NO RESPONSIBILITY FOR UTILITIES
,_^ _/f /'- / NOT SHOWN OR UTiLI0E5 NOT SHOWN IN THEIR PROPER LOCATION.
BY 401111V SAA-// 311 I CALL BEFORE YOU DIG: 1 -800- 424 -5555
I UNDERGROUND SERVICE (USA)
MAR 3 0 2000 S
,_ I