Loading...
HomeMy WebLinkAboutS-2847051. CONSTRUCTION STANDARDS ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE CONSTRUCTION DRAWINGS, TECHNICAL SPECIFICATIONS, THE UNIFORM BUILDING CODE (1997 EDITION) AS AMENDED BY CHAPTER 51 -40 OF THE WAC, THE RENTON MUNICIPAL CODE, AND THE CITY OF RENTON STANDARD PLANS & SPECIFICATIONS. 2. CONSTRUCTION SAFETY THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT THE PUBLIC AND PREVENT NUISANCES WHILE PERFORMING CONSTRUCTION WORK ON THIS PROJECT. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. 3. UTILITIES ALL UTILITIES: EXISTING UTILITIES INDICATED ANYWHERE ON THE DRAWINGS HAVE BEEN PLOTTED FROM THE BEST INFORMATION AVAILABLE TO THE ENGINEER AND SURVEYOR. THE SOURCE OF INFORMATION GENERALLY CONSISTS OF CONSTRUCTION RECORDS, UTILITY LOCATES, AND OTHER DATA OBTAINED VERBALLY FROM OFFICIALS ASSOCIATED WITH THE PARTICULAR UTILITY. OWNER AND ENGINEER DO NOT GUARANTEE NOR ASSUME RESPONSIBILITY FOR THE ACCURACY OF THIS INFORMATION. IT IS UNDERSTOOD THAT OTHER ABOVE GROUND AND UNDERGROUND FACILITIES NOT SHOWN ON THE DRAWINGS MAY BE ENCOUNTERED DURING THE COURSE OF THE WORK. THE CONTRACTOR SHALL VERIFY THE TRUE AND CORRECT LOCATION OF EXISTING UTILITIES TO AVOID DAMAGE OR DISTURBANCE. THE CONTRACTOR SHALL REPAIR ALL DAMAGED UTILITIES IMMEDIATELY. 4. PRE — CONSTRUCTION CONFERENCE A PRE — CONSTRUCTION CONFERENCE AND TWENTY —FOUR HOUR NOTICE WILL BE REQUIRED PRIOR TO STARTING CONSTRUCTION. 5. PERMITS AND INSPECTIONS a. PERMITS: THE CONTRACTOR SHALL SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. SEE SPECIFICATIONS FOR FURTHER INFORMATION REGARDING PERMITS. b. INSPECTION: THE CONTRACTOR SHALL OBTAIN ALL BUILDING DEPARTMENT INSPECTIONS DURING CONSTRUCTION. SOME OF THE INSPECTIONS WILL BE PERFORMED BY A REPRESENTATIVE OF THE CITY OF RENTON. THE CONTRACTOR SHALL NOTIFY THE REPRESENTATIVE 24 HOURS IN ADVANCE OF ANY BACKFILLING OR COVERING OF CONSTRUCTION. 6. CONTRACTOR INITIATED CHANGES TO DESIGN CHANGES SHALL BE SUBMITTED IN WRITING TO THE CITY OF RENTON FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY, WILL NOT SATISFY THIS REQUIREMENT. 7. H -20 TRAFFIC RATING ALL STRUCTURES, MANHOLES, VAULTS, HANDHOLES, LIDS, COVERS, AND ACCESS HATCHES INSTALLED THIS PROJECT SHALL BE H -20 TRAFFIC RATED. CONTACT NAME POSITION PHONE CITY OF RENTON DAVE CHRISTENSEN WASTEWATER UTILITY AND TECHNICAL SERVICES SUPERVISOR 425 - 430 -7206 CITY OF RENTON RON SHAFFER SEWER AND STORM OPERATIONS MANAGER 425- 235 -2585 CITY OF RENTON RAY SLED WATER OPERATIONS MANAGER 425- 235 -2646 OWNER JOHN LONG MECHANICAL PLAN AND PROFILE 253 - 606 -9629 RH2 ENGINEERING MARK MILLER PROJECT ENGINEER 425 - 951 -5372 PSE LAWRENCE HIRCH ELECTRICAL & GAS 253- 395 -6915 DRAWING NAME SHEET DRAWING NUMBER COVER AND GENERAL INFORMATION 1 G1 EXISTING SITE PLAN 2 JL1 PROPOSED SITE PLAN 3 JC1 PROPOSED FORCE MAIN ALIGNMENT 4 JC2 PROPOSED STRUCTURAL_ PLAN 5 JS1 MECHANICAL PLAN AND PROFILE 6 JM1 ELECTRICAL LEGEND SHEET 7 JE1 ONE —LINE DIAGRAM 8 JE2 ELECTRICAL SITE PLAN 9 JE3 ELECTRICAL PLAN 10 JE4 LADDER AND GRATING DETAILS 11 JG1 MISCELLANEOUS DETAILS 12 JG2 ELECTRICAL DETAILS 13 E1 TELEMETRY DETAILS 14 E2 .. fir.. t� M.P EXPIRES 3/19/2008 SIGNED. 08131100 ENGINEERS PLANNERS SCIENTISTS B I.LINGHAM OFFICE s6 0.676.083r 454 `Test Norton Road BOTH ELL OFFICE 425.95i.5AC". 12100 ICE 195th Street, Suite 100 EAST WENATCHEE OFFICE ,)09,88E2900 300 Simon Street, Suite 5 PORT ORCHARD OFFICE 360,8 / % 960 600 Kir qo St. ,ct, Suite 100 z O 1 DRAWING • IF •A• IS NOT 2" LONG PLOT: ® W W DATE: 0-0 O IC / ®/ , 9 07- LL z __j Q W 7E > W WC af Q O LL_ w Z z w O° j Q 0 z � Q Z � O W D O V ENGINEERS PLANNERS SCIENTISTS B I.LINGHAM OFFICE s6 0.676.083r 454 `Test Norton Road BOTH ELL OFFICE 425.95i.5AC". 12100 ICE 195th Street, Suite 100 EAST WENATCHEE OFFICE ,)09,88E2900 300 Simon Street, Suite 5 PORT ORCHARD OFFICE 360,8 / % 960 600 Kir qo St. ,ct, Suite 100 1 DRAWING • IF •A• IS NOT 2" LONG PLOT: ® II11 ENGINEER: I JB DATE: 1 IC / ®/ , 9