Loading...
HomeMy WebLinkAboutS-284712PUMP # 1 PUMP # 2 j 10 a� HP 1W'1g>l w CONDUIT PENETRATIONS TO VAULT AND WET WELL. PROVIDE INSULATED PLASTIC BUSHING. THOMAS AND BETTIS #226 TYPICAL WET WELL, VALVE VAULT AND HAND HOLES. PROPOSED ELECTRICAL S -8" L x 2' -8" W x S -6" H' ELECTRICAL VAULT FOR SPLICING JACKETED CABLE TO BUILDING WIRE. UTILITY VAULT COMPANY MODEL # 233 -LA OR EQUAL. (TYPICAL). LS3 LS2" LS1 WET WELL TRANSDUCER. SEE DETAIL ON DWG NO. JG2. A ELECTRICAL VAULT ON EYS CLASS 1 DIVISION 1 AREA FAI M& ZS1 0 ZS2 ``.. DRY WELL CHECK VALVE LIMIT SWITCH (TYPICAL) SUMP PUMP MOTOR ELECTRICAL VAULT WATERPROOF CABLE SPLICE (TYPICAL) CLASS 1 DIVISION 1 AREA ❑iiu POWER ACEWAY SCHEDULE ELECTRICAL EQUIPMENT LEGE ; , RACEWAY DESCRIPTION ORIGINATION TERMINATION Q 1 -1/4" GRC, 4 - #3 SERVICE DISCONNECT UTILITY METER A 1 -1/4" GRC, 4 - #3 UTILITY METER MANUAL TRANSFER SWITCH Q 1 -1/4" GRC, 4 - #3 MANUAL TRANSFER SWITCH DISTRIBUTION BOX 0 1 -1/4" GRC, 4 - #3 MANUAL TRANSFER SWITCH GENERATOR CONNECTION RECEPTACLE CONNECTION TO MASTER BY OTHERS. CONNECT TO PROPOSED SENSORS, ALARMS, AND DEVICES. 1 -1/4" GRC, 4 - #3 DISTRIBUTION BLOCK PUMP CONTROL PANEL 0 1/2" GRC, 2 - #10, 1 - #10G DISTRIBUTION BLOCK TRANSFORMER DISCONNECT WITH 1,50 WATT EXTENDED SERVICE LIGHT BULB. APPLETON PART NOS. AALB -75 (BRACKET), AAU -15N 1 -1/4" GRC 2- #3,1 - #8G TRANSFORMER DISCONNECT 5kVA TRANSFORMER gQ, 3/4" GRC, 3 - #8, 1 - #8G 5kVA TRANSFORMER LOAD PANEL Q 1/2" GRC, 2 - #12, 1 - #12G ELECTRICAL ENCLOSURE LIGHT BREAKER 1/2" GRC, 2 - #12, 1 - #12G WET WELL LIGHT BREAKER 11, 1 2 GRC 2 12 1 12G / # # VALVE V RECEPTACLE L E AULT RECE BREAKER WITH 1;50 WATT EXTENDED LIFE BULB. HUBBELL MODEL VX -151 OR EQUAL. 1/2" GRC, 2 - #12, 1 - #12G SUMP PUMP BREAKER A 1" GRC, 3 - #10, 4 - #14, 1 - #10G MOTOR N0. 1 MOTOR STARTER Q 1" GRC, 3 - #10, 4 - #14, 1 - #10G MOTOR NO. 2 MOTOR STARTER 0 1 -1/2" GRC, PUMP 1 JACKETED CABLE MOTOR NO. 1 MOTOR STARTER A: 1 -1/2" GRC, PUMP 1 JACKETED CABLE MOTOR NO. 2 MOTOR STARTER AAA 1" GRC, 6 - #14 FLOAT SWITCHES TELEMETRY PANEL �, 1 -1/2 GRC, JACKETED CABLE LEVEL TRANSDUCER TELEMETRY PANEL A 2" GRC, 3 -FLOAT CABLES FLOATS TELEMETRY PANEL A 1" GRC, 8 - #12, 4 - #12G VALVE VAULT DEVICES TELEMETRY PANEL A 1" GRC, 14 - #14, 1 - #14G PUMP CONTROL PANEL TELEMETRY PANEL At ANTENNA CABLE TELEMETRY RADIO ANTENNA Q 1/2" GRC, 2 - #14, 1 - #14G INTRUSION ALARM SWITCH TELEMETRY PANEL 0 1/2" GRC, 2 - #12, 1 - #12G GFI RECEPTACLE BREAKER O LS1 O ZS3' EYS WAW FAI LEVEL TRANSMITTER BELLOWS ATTACHED TO SIDE OF VAULT PER MANUFACTURE'S RECOMMENDATIONS 1:14 11,, WET WELL LIGHT SWITCH. MOUNT IN EASY TO ACCESS LOCATION. 3/4 "x8' LONG COPPER GROUND ROD (TYPICAL) GFI . . ' .go TO UTILITY POWER #6 BARE COPPER GROUNDING ELECTRODE CONDUCTORS TO GROUND RODS PER N.E.C. SIGNED. 08131100 vd�, LL.71 J +�j �aCl ST8!�9 I01x3 A' EXPIRES 11/3/01 SIGNED. 08131100 � z W 0 Li c) Oz __j Q W 75 > U Li W rz O O O o� Q Ln J O D • J� REVISED TO CONFORM TO CONSTRUCTION RECORDS CITY OF RENTON REVISION NO. REVISION ht't,) // v4 w.th2'.com nnaC I ox,,5'o,1.u0'1'i ?.80:; . 72,10. 80-52 BELLINCIiAM OFFICE 360.67F)_0836 454. WeSt t;orton Road E OTHEI.,I....OFFICE 12 u pit `+5th Street, Suite 100 EAST NA CHEE OF'F'ICE 509.88 ?x;00 300 Street, Suite 5 PORT ORCHARD OFFICE 360 387 6. 7x)60 600 Kitsiuc, Si ee , Sl; `e 10I SCALE: SHOWN 0 1„ 2„ DRAWING IS NOT TO SCALE IF BAR IS NOT 2" LONG PLOT: 1 DWG NO. ENGINEER: DJB Il E2 REVIEWED: MM DATE: JAN 24, 2007 SNEE 0. NLA MLM 12/1/06 CLIENT: DJB MM 8/24/00 SOS NO.: 14 BY REVIEW DATE FILENAME: JLD -E1 ELECTRICAL EQUIPMENT LEGE ; , A O SERVICE ENTRANCE DISCONNECT SWITCH - NEMA 3R, HEAVY DUTY BREAKER, SERVICE RATED, 100 C) GENERATOR CONNECTION RECEPTACLE - OUTDOOR RATED, 60OV, 100A, 4 -POLE, 3 -WIRE, THREADED AMP 600 VOLT CIRCUIT BREAKER SWITCH. SIEMENS MODEL E3RED63B100 OR EQUAL. SERVICE > ' CAP, WEATHERPROOF. GROUSE HINDS MODEL N0. AREA10486 OR EQUAL THAT MATCHES CITY'S ENTRANCE SWITCH SHALL INCLUDE A SURGE SUPPRESSION UNIT AS IDENTIFIED ON THIS SHEET. EXISTING PLUG. © MANUAL TRANSFER SWITCH - NEMA 3R, DOUBLE THROW, NON -FUSED SAFETY SWITCH, 600 VOLT, 100 CO) TELEMETRY PANEL - PROVIDED BY OTHERS, INSTALLED THIS CONTRACT. PROGRAMMING AND AMP, SIEMENS MODEL NFR353DTK OR EQUAL. (SIZE: 12 "Wx25 "Hx5 "D) CONNECTION TO MASTER BY OTHERS. CONNECT TO PROPOSED SENSORS, ALARMS, AND DEVICES. © 480 VOLT DISTRIBUTION BOX - NEMA 3R, SIZED PER N.E.C. C) WALL MOUNTED INCANDESCENT FIXTURE - EXPLOSION PROOF, 120 VOLT, 150 WATT RATED. FURNISH WITH 1,50 WATT EXTENDED SERVICE LIGHT BULB. APPLETON PART NOS. AALB -75 (BRACKET), AAU -15N OD 240/120V LIGHTING PANELBOARD - NEMA 3R, SINGLE PHASE, 3 WIRE, SOLID NEUTRAL, 16 SPACES. FIXTURE UNIT), AAGU -1 ALUMINUM GUARD OR EQUALS. FURNISH ALL NECESSARY CONDUIT AND SIEMENS MODEL W1624MB1100CU OR EQUAL. PROVIDE BREAKERS AS SHOWN ON ONE -LINE DIAGRAM. SEALS TO MEET EXPLOSION PROOF CRITERIA. MOUNT AS HIGH AS POSSIBLE ON WALL. (SIZE: 14.5 " Wx22 " Hx4.5 " D) C) ELECTRICAL EQUIPMENT PANEL LIGHT FIXTURE - INCANDESCENT, 120 VOLT, 150 WATT RATED. FURNISH EO PUMP CONTROL PANEL - SEE SPECIFICATIONS. WITH 1;50 WATT EXTENDED LIFE BULB. HUBBELL MODEL VX -151 OR EQUAL. 0 TRANSFORMER DISCONNECT SWITCH - NEMA 3R, HEAVY DUTY, 3 -POLE, 3 -WIRE, 30 AMP, 600 VOLT, C) LIMIT SWITCH FOR ACTIVATING PANEL LIGHT. SQUARE D HEAVY DUTY TYPE C, CLASS 9007 OR EQUAL. FUSED DISCONNECT SWITCH. SIEMENS MODEL FR351 OR EQUAL. (SIZE: 8.5 " Wx15 " Hx4.5 " D) CONTRACTOR SHALL SELECT ACTUATOR LEVER ALARM BEST SUITED FOR MOUNTING CONFIGURATION. © LOW VOLTAGE TRANSFORMER - OUTDOOR RATED, DRY -TYPE, 5 KVA, 240x480- 120/24OV, SINGLE C) INTRUSION ALARM SWITCH - SQUARE D HEAVY DUTY TYPE C, CLASS 9007 OR EQUAL. USE LIQUID PHASE. SIEMENS MODEL 1D1N005ST OR EQUAL. (SIZE: 10 " Wx15 " Hx12 D) TIGHT FLEXIBLE CONDUIT BETWEEN JUNCTION BOX AND LIMIT SWITCH. CONTRACTOR SHALL SELECT ACTUATOR LEVER ALARM BEST SUITED FOR MOUNTING CONFIGURATION. 0 ELECTRICAL CEILING HEATER - 1OKW, 480 VOLT, 3 PHASE 34,100 BtuH, ELECTRICAL HEATER WITH UNIVERSAL MOUNTING BRACKET. MOUNT PER MANUFACTURER'S RECOMMENDATION. DAYTON T C) CHECK :VALVE POSITION LIMIT SWITCH - SQUARE D HEAVY DUTY TYPE C, CLASS 9007 OR EQUAL. USE HEAVY -DUTY MODEL OR APPROVED EQUAL. PROVIDE WITH WALL MOUNTED THERMOSTAT ADJUSTABLE LIQUID TIGHT FLEXIBLE CONDUIT BETWEEN JUNCTION BOX AND LIMIT SWITCH. SEE DETAIL ON DWG N0. BETWEEN 50° TO 807. THERMOSTAT SHALL HAVE A ROOM TEMPERATURE THERMOMETER. SET G2. THERMOSTAT AT 557. C) FLOOD SWITCH - OMEGA MODEL LV -10 OR EQUAL. MOUNT TO END OF 1/4" PVC PIPE AND SECURE TO K ELECTRICAL HEATER DISCONNECT - NEMA 3R HEAVY DUTY 3 -POLE 3- WIRE 30 AMP 600 VOLT WALL WITH MINIMUM OF TWO STAINLESS STEEL PIPE CLAMPS. SWITCH SHALL TRIP AT 1/2" OF WATER FUSED DISCONNECT SWITCH. SIEMENS MODEL FR351 OR EQUAL. (10 "Wx15 "Hx12 "D) LEVEL IN VAULT. © UTILITY METER ENCLOSURE - AS APPROVED BY PUGET SOUND ENERGY. C) WET WELL LIGHT SWITCH - AC QUIET TYPE 20 AMP SINGLE POLE. 30 AMP FUSE BLOCK IN A NEMA 4 6 "x6 "x6" ENCLOSURE. C) TRANSIENT VOLTAGE SURGE SUPPRESSER - 6 "x6 "x6" NEMA 4 ENCLOSURE, ORION MODEL ORN -3Y 277/48OV. NO SUBSTITUTION. GFI . . ' .go TO UTILITY POWER #6 BARE COPPER GROUNDING ELECTRODE CONDUCTORS TO GROUND RODS PER N.E.C. SIGNED. 08131100 vd�, LL.71 J +�j �aCl ST8!�9 I01x3 A' EXPIRES 11/3/01 SIGNED. 08131100 � z W 0 Li c) Oz __j Q W 75 > U Li W rz O O O o� Q Ln J O D • J� REVISED TO CONFORM TO CONSTRUCTION RECORDS CITY OF RENTON REVISION NO. REVISION ht't,) // v4 w.th2'.com nnaC I ox,,5'o,1.u0'1'i ?.80:; . 72,10. 80-52 BELLINCIiAM OFFICE 360.67F)_0836 454. WeSt t;orton Road E OTHEI.,I....OFFICE 12 u pit `+5th Street, Suite 100 EAST NA CHEE OF'F'ICE 509.88 ?x;00 300 Street, Suite 5 PORT ORCHARD OFFICE 360 387 6. 7x)60 600 Kitsiuc, Si ee , Sl; `e 10I SCALE: SHOWN 0 1„ 2„ DRAWING IS NOT TO SCALE IF BAR IS NOT 2" LONG PLOT: 1 DWG NO. ENGINEER: DJB Il E2 REVIEWED: MM DATE: JAN 24, 2007 SNEE 0. NLA MLM 12/1/06 CLIENT: DJB MM 8/24/00 SOS NO.: 14 BY REVIEW DATE FILENAME: JLD -E1