HomeMy WebLinkAboutS-289401SEC. 5, T . 23N., RGE. 5E., WM.
o qu \� o '
04 65
-7
T---- STA. Af55 RT. 25' ✓ so
10 i I
a
SURFACE GRADE
I i I ! \\
1-2LF 6' 01
1-5)(-UkV F.H. ASSY eo
60 1 1
I ......... .... .............................. ........... CONIC. SLOCCING ✓
77 . ..... . ............
LLJ
0
STA. 1*1j RT 25'
QI-
LLJ as
bS`ZECr Ag REO&YRED
MAX. V&LhU TO HE
82
C. BLOCKING 55 !
--- --------------------------
Q M41hV
STA. 0*20, Rr. 25'
V) < LJ in cv, -
LLj t: 0 z 0, Mq YU 5
<
o 50 b"
< < .... ..... ...... .......... ........... .....
t:2
LLj
_L VC 8' 5 ed
1- 121 STORM -\
2r < 0 Lj
0 74
4F 5' 0.1
0 Lq
_j 8
�2
Ld 1-5j(, MVO F.H. FH. ASSY
7
. ..... 6 <
O [Z 0 CCYVC. BLOCKING 4
Uri 5
0 0 EA
Ld (WA 7ERLINE TO CL R UNDER STORM BY 12" MIN.)
L) LTV m
a- bI 66
0
-y
Z 40 STA. 0*J8 RT 25' 'Y OF
.. .........
I - 10' HA U MF0? 64
a7/RfACE &?AOF 2-1jf'PRV
N
1 -1' IA'RlrA 770,V METER PffLEC
2-DalbZf CNSCK VAL kE ASSY Mf
mult fly
A
< 45 45 6
6
q., N p
- 77�_
T6 FM
T.-
-7 7LF cri Lc
40 1 40: 60
. . ....... .
L L
60
58
J5 J5
56 . .... . .......
0
P0598LE fmvc L
ZE FIRE SWNKLER PLANS
54
. . .. ....... FOR A07LIAL LOCA776W
FIRST FF 60.0
GARAGE ff = 50.5
INSTALL U77LITY VAULT OIL/RATER 55PARA700? UNIT 577-SA'
52
OR EQUAL. CONNECT TO GARAGE fZOX DRAN AND SANITARY
TL AND AS REWIR0.
SCALE: 1 20' z
HORIZ SCALE- 1'�-20'
pRot
0 10 20 40
VERT SCALE 1" 5' pw 5q C C r-
01� j
CITY OWNED
AND MAINTAINED PRIVATELY OWNED AND MAINTAINED VER77CAL DA TUY: CITY OF R611TON NAD 88 48
MAXIMUM PIPE LENGTH FROM PROPERTY LINE BUILDING WALL 10 V_ I
-T F6 MIN.
TO DDCVA MUST NOT EXCEED 50 F;:i� sy 5
CD 7,,, PERIMETERS N07E- WA MiLINE SCREDED HAS BLOV 0
OF MINIMUM CLEARANCES TO BE 2
O \—SANITARY.9DE
!, x PAINTED ON FLOOR IN WHITE ENAMEL
INSTALLED &TOO?f 1-22-01.
4 CONCRETE BOLLARDS
04 STRIPE, WITH 2 INCH STENCILED BLACK LETTERS SFJffR C06NEcC77OY
03 TO SAY: "DO NOT BLOCK ACCESS' ti
5
DDCVA MUST BE INSTALLED IMMEDIATELY AFTER
A
Fr. MAX. PIPE PENETRATION THROUGH BUILDING FLOOR SLAB. • Z 7
ROOM IN WHICH DDCVA IS LOCATED SAALL:
9 A. HAVE FLOOR DRAIN CONNECTED TO THE SANITARY SEWER SYSTEM.
_j Of - - -
< B. HAVE A HEATING SYSTEM (40- F MIN. TEMP.) NO 'HEAT TAPE
L)
Cd ai < C. NOT BE USED FOR STORAGE AROUND THE DDCVA J'± 8" SPOOL
w z a 44
D. HAVE CLEARLY DELINEATED ACCESS WAYS TO DDCVA AND PIVs. 70 f1T 874.15'
im
3c 0
0 A RIGHT-OF-ENTRY AGREEMENT MUST BE GRANTED TO THE 1814
If 11 1 3050 �081 CONC. MON. IN CASE
z m CITY OF RENTON FOR INSPECTION OF THE DDCVA
Ld AND METER. L3 STA 19+81.26
Lj _),F 3" BRASS DISK
0
0 z SEPARATE FIRE SPRINKLER PLANS INCLUDING INSTALLATION OF DDCVA
< <
L
d
Uj MUST BE SUBMITTED TO RENTON FIRE PREVENTION DEPARTMENT FOR ✓
Uj A SEPARATE FIRE SPRINKLER PER 13.00
'MIST IS REQUIRED.
/24 INC I (on 48 INCH J
9 / 0 REVIEW AND APPROVAL.
0 CD /
z SEE DETAIL BELOW .5 0
STA 28f5531 (LK MASH. BLVD.))
SM. 28*6&,T1 (IX. WASH. &W.)
LOCKING (L
::3
(WATER MAIN LOCATED IN EASEMENT ON PRIVATE PROPERTY '0�
cn FE @ @ 1 28* STA 0+00
> (C 1R. LINE fSV'T RD.)
I- MAIN LINE TEE (MJ x FL) WITH CONCRETE BLOCKING
CLEANING "POLY-PIG' IN: 85.81
SHALL NOT BE MORE THAN 50 ET TO BUILDING) 24 INCH MINIMUM
2- BRANCH VALVE (FL x MJ) WITH VALVE BOX AND COVER 36 INCH MAXIMUM 3 B'xB* VERTICAL CROSS(MAFL)
in
3- CLASS 52 DUCTILE IRON PIPE (4 INCH MINIMUM) LL FINISH FLOOR LEVEL 2-8- BLIND RANGES (ONE W/2' 3" BRASS DISK
ALL PIPE AND FITTINGS SHALL BE RESTRAINED WITH SHACKLE RODS TAP AND 2' PLUG) MONUMENT
in
AND CONCRETE THRUST BLOCKS PER NFPA AND AWWA STANDARDS. I
1
4- POST-INDICATOR VALVE (MJ) WITH TAMPER SWITCH D ELEVATION VIEW OF DDCVA 1-8- PWG(MJ) W/2-TAP & 2- STA 47+34.62
izi 5- 2-90' SENDS (FL x FLI WITH FLANGED DUCTILE IRON PIPE SPOOL a, BLOW-OFF
0
> TEMP. BLOCK
fi- 18 L (FL PE 0 x ) 1
in ' ONG SPOOL AFTER ALL TESTING, LEGEND
7- FLANGE COUPLING ADAPTOR CL J.
8- APPROVED DDCVA ON MAIN LINE IN HORIZONTAL POSITION ONLY. 1-12'x8' TAPPING TEE (MJxFQ CLEANING AND • P/ v - POST r INDIcA ToR vAL PE pT has
V) (PER LATEST DEPT. OF HEALTH APPROVED LIST OF BACKFLOW PREVENTION DEVICES) 1-8- TAPPING GATE VALVE (FLxMJ) DISINFECTION. REMOVE
< z BOTTOM OF DDCVA SHALL BE A MINIMUM OF 24 INCH ABOVE FLOOR LEVEL AND - PLUG (MJ) NTH f TAP AND 2- TEMP, BLOCK & BLOW- FY - FIRE SPRINKLER VAULT (D!OCYA) (IN BUILDING)
3: 0 NOT HIGHER THAN 3 FEET MAXIMUM. INSTALL 3 CONCRETE PADS OR ADJUSTABLE PIPE 1-8 fDC - FIRE DEPARTMENT CaVNE00W Dodds
OF & CONNECT WITH
5; LA SUPPORT COLUMNS TEMP. BLOWOFF ASSEMBLY 83 #U - WATER METER Consulting
UNDER DDCVA - SLEEVE (MJ) AND
�j 9- ^..S & Y VALVES TO BE RESILIENT SEATED WITH TAMPER SWITCHES. TEMP. CONIC BLOCK 8 1E PRIV-PRESSIllm- :;EDUCING VALVE x 0 of ADD WIRING IN ACCORDANCE WITH L & 1 8' D.I. SPOOLS. Engineers
10- METERED 3/4 INCH BY-PASS DCVA - BY-PASS METER SHALL BE A 3/4 INCH L
SENSUS-ECR" SR POSITIVE DISPLACEMENT METER EQUIPPED WITH A REMOTE N DCVA - DOUBLE CHECK VALVE ASSEMBLY AIR -VAC A SS,-Y& Y .0k
READ SENSOR PLATE MOUNTED ON THE OUTSIDE OF THE BUILDING WALL. EXISTING 12- EXISTING 12 --1 V
0 lt- SWING TYPE GRAVITY CHECK VALVE, FLANGE WITH BALL DRIP .4 VAULT WATERLINE
LAJ _j 12- 4'x 4" x 6" BULL. ELBOW. THREADED INSIDE BUILDING INS TALLA T/ON FOR _J TERLINE WATERLINE _J L
a- "J i3- UL LISTED FIRE DEPT. CONNECTION, UL LISTED BREAK AWAY CAPS, LOCATE WITHIN
0 w 50 FEET MAXIMUM OF A PUBLIC FIRE HYDRANT. 3 INCH AND LARGER TESTING DETAIL FINAL CONNECTION DETAIL RECOMMENDED
AL
U) Q_ UNDERGROUND LOCATOR SERVICE FOR A PROV 4205 148th Ave. N.E.
5; 2 AFTER FIELD INSTALLATION, MAIN DDCVA AND BY-PASS DCVA MUST BE TESTED
Lj 0 SATISFACTORILY BY A DEPARTMENT OF HEALTH CERTIFIED RACKFLOW ASSEMBLY DETECTOR DOUBLE CHECK VAL VE A SSEMBL Y Bellevue, Washington 98007
TESTER. TEST REPORT MUST BE SUBMITTED TO CITY OF RENTON WATER UTILITY 12' MAN 00AINECT101V DETAIL CALL BEFORExYOU DIGI BY, [4
61 .1 -1 25) 861-4928 (425) 885-7963 Fax
ENGINEERING DEPARTMENT PRIOR TO ACTIVATION OF NEW LINE. 1-800-424-5555 BY C INSTALL BRASS PLUGS AT ALL TEST COCKS. NO SCALE
C5 VVii0V_.&;p -.& B 26 owhol
z Y
A.
WE
OILL 16�9 FR ILK