HomeMy WebLinkAboutS-29000f!1L THERMAL MAGNETIC BREAKER L THERMAL OVERLOAD -� MAGNETIC BREAKER ONLY WALL/CEIUNG MOUNTED CIRCUIT BREAKER RILILUMINATED CIRCUIT BREAKER WITH SHADED AA INDICATED CURRENT LIMITING FUSE ® FUSE WALL NTH R MOUNTED BA TERM EMERGENCY LIGHT NTH REMOTE BATTERY FUSED SVWTCH -O FUSE CUTOUT ST SHUNT TRIP SWITCH UNIT SUBSTATION, SWITCHGEAR, MOTOR CONTROL CENTER SURFACE MOUNTED PANELBOARD FLUSHED MOUNTED PANELBOARD CONTROL STATION EQUIPMENT MOUNTING STAND M SINGLE PHASE MOTOR. HORSEPOWER AS NOTED 75 THREE PHASE MOTOR. H'PV HORSEPOWER AS NOTED ' ^` !^I\ L I7 MOTORIZED LOUVER ACTUATOR u I��� /// ��` SAFETY SWITCH COMBINATION MOTOR STARTER AND SAFETY SNITCH O51 S MANUAL MOTOR STARTER OGROUND ROD SIZED PER N.E.C. USE EXOTHERMIC WELD CONNECTION AT THE GROUND ROD. HH MANHOLE OR HANDHOLE MH ODISCONNECT SNITCH ® STANDARD SWITCH, 120VAC, 20 AMP 3 -WAY SWITCH, 120VAC, 20 AMP SWAY 4- POSITION SWITCH, 120VAC, 20 AMP, ® HOA LABEL SNITCH POSITION HAND - OFF -MOTION -PHOTO FLUORESCENT FIXTURE ��� jjj•����(� WALL/CEILING MOUNTED FIXTURE --{ )jjj����( POLE MOUNTED FIXTURE WALL/CEIUNG MOUNTED ® RILILUMINATED 1 I SHADED AA INDICATED VARH - VARHOUR METER FACE WALL TELEPHONE OUTLET ( +12-) WALL NTH R MOUNTED BA TERM EMERGENCY LIGHT NTH REMOTE BATTERY AM wrA- 27 --42910e O CEILING JUNCTION BOX ELECTRICAL SYMBOLS LEGEND CURRENT TRANSFORMER WALL JUNCTION BOX MOTOR OPERATION COUNTER tf EMERGENCY LIGHT WITH SELF Fil FLOOR JUNCTION BOX VARH - VARHOUR METER WALL TELEPHONE OUTLET ( +12-) CONTAINED BATTERY AM VA - VOLT AMMETER SSRVS HEATER, WATTAGE NOTED WALL TELEPHONE OUTLET ( +60') T SINGLE RECEPTACLE, 120V FLOOR TELEPHONE OUTLET () I&— T UTILITY POLE AND GUY WARE SSR'JS - SOL'0 STATE REDUCED VOLTAGE STARTER �T F FIRE ALARM PULL STATION P - POWER OKIRK KEY INTERLOCK J - INSTRUMENTATION CONNECTION POINT, EXOTHERMIC WELD. CADWELD OR FIRE ALARM FLASHING LIGHT F CJ - CONTROL & INSTRUMENTATION APPROVED EQUAL SINGLE RECEPTACLE, 208V MFIRE ALARM HORN F -�- PIGTAIL. BARE COPPER. LENGTH AS REQUIRED. W MINII VARIABLE FREQUENCY DRIVE • DUPLEX WALL RECEPTACLE , 120V BELL ^' CAPACITOR B Lp WP = WEATHERPROOF G = GROUNDED 6 BUZZER /111^ POWER TRANSFORMER OHEAT DETECTOR IG = ISOLATED GROUND ivy CONTROL POWER TRANSFORMER SOLID NEUTRAL GF = GROUND FAULT INTERRUPTER N ® DUPLEX FLOOR RECEPTACLE, 120V END OF UNE RESISTOR LIGHTING ARRESTOR FACP FIRE ALARM CONTROL PANEL TRANSFORMER SPECIAL PURPOSE WALL RECEPTACLE, -O 0--1II SURGE ARRESTER EOL INSTRUMENT RATING AS NOTED METAL PIPE GROUND O CEILING JUNCTION BOX INSTRUMENT METER CURRENT TRANSFORMER WALL JUNCTION BOX A - AMMETER VAR - VARMETER VOLTAGE TRANSFORMER Fil FLOOR JUNCTION BOX VARH - VARHOUR METER WALL TELEPHONE OUTLET ( +12-) 75WATTS AM VA - VOLT AMMETER HEATER, WATTAGE NOTED WALL TELEPHONE OUTLET ( +60') HEATER FLOOR TELEPHONE OUTLET () I&— T UTILITY POLE AND GUY WARE © POWER VAULT F FIRE ALARM PULL STATION P - POWER OKIRK KEY INTERLOCK J - INSTRUMENTATION CONNECTION POINT, EXOTHERMIC WELD. CADWELD OR FIRE ALARM FLASHING LIGHT F CJ - CONTROL & INSTRUMENTATION APPROVED EQUAL PLUG -IN CONNECTION MFIRE ALARM HORN F L L•J ` PIGTAIL. BARE COPPER. LENGTH AS REQUIRED. W MINII • CONNECTION POINT, MECHANICAL, COMPRESSION TYPE. BELL T CAPACITOR B ENGINE GENERATOR 6 BUZZER ® GENERATOR CONNECTION RECEPTACLE OHEAT DETECTOR SOLID NEUTRAL O SMOKE DETECTOR N FT.] TERMINAL BLOCK END OF UNE RESISTOR LIGHTING ARRESTOR FACP FIRE ALARM CONTROL PANEL -O 0--1II SURGE ARRESTER EOL INSTRUMENT METAL PIPE GROUND GE ELECTRICAL PLUG LIMIT SWITCH LIMIT SNITCH -SQUARE D HEAVY DUTY TYPE C, CLASS MOTION DETECTOR 04,_O 9007 OR APPROVED EQUAL SELECT ACTUATOR LEVER MD ARM BEST SUITED FG MOUNTING ON ACCESS HATCH. PC PHOTO CONTROL CELL - GROUND EYS EXPLOSION PROOF CONDUIT SEAL FITTING CONTACTOR T VACUUM BREAK SNITCH RTM MOTOR RUN TIME METER INDICATE TYPE BY INSTRUMENT METER LETTER A - AMMETER VAR - VARMETER U AH - AMPERE -HOUR VARH - VARHOUR METER PF - POWER FACTOR V - VOLTMETER W - WATTMETER VI H - WATTHOUR METER AM VA - VOLT AMMETER ABBREVIATIONS SPDT - SINGLE POLE, DOUBLE THROW SPST - SINGLE POLE, SINGLE THROW DPST - DOUBLE POLE, SINGLE THROW WP - WEATHER -PROOF GFl - GROUND FAULT INTERRUPT P - POWER C - CONTROL J - INSTRUMENTATION PC - POWER & CONTROL CJ - CONTROL & INSTRUMENTATION GENERAL NOTES 1. THIS IS A STANDARD LEGEND. NOT ALL OF THE INFORMATION SHOWN GN THIS PACE WILL APPEAR IN THIS SET OF PLANS. I THESE DRAWINGS ARE DIAGRAMMATIC ONLY-. EXACT LOCATIONS OF ELECTRICAL EQUIPMENT SHALL BE DETERMINED IN THE FIELD BY THE ENGINEER. THE INSTALLATION OF ALL EQUIPMENT SHOWN ON THESE DRAWINGS OR DESCRIBED IN THE SPECIFICATIONS SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE LATEST EDITIONS OF ALL APPLICABLE CODES AND UTILITY COMPANY STANDARDS. CONTACT THE UTILITY COMPANY REPRESENTATIVES AND VERIFY THEIR REQUIREMENTS. 3. NOTIFY THE ENGINEER IMMEDIATELY IF CONFLICTS IN EQUIPMENT LOCATIONS ARE DISCOVERED OR IF PROBLEMS ARISE DUE TO FIELD CONDITIONS. LACK OF INFORMATION OR ANY OTHER REASON. NO PAYMENT WILL BE MADE FOR CHANGES WHICH HAVE NOT BEEN FAVORABLY REVIEWED BY THE ENGINEER LINE TYPE LEGEND - OHP EXISTING OVERHEAD POWER P EXISTING UNDERGROUND POWER - TEL EXISTING TELEPHONE PROPOSED TELER*NL FA -- FIRE ALARM CONDUIT S SAL 'EXISTING S,',AAL 120 /240 VOLT WIRING 480 VOLT WIRING SIGNAL WIRING - - UNDERGROUND DIRECT BURIAL CABLE WIRING CONNECTED BUS CONDUIT CONCEALED BELOW GRADE, IN SLAB - — — — — - OR WALL LINE TYPE COLOR WALL VARY DEPENDING ON VOLTAGE CONDUIT AND WARE EXPOSED OR SURFACE MOUNTED UNLESS OTHERWASE NOTED. LINE TYPE COLOR WILL VARY DEPENDING ON VOLTAGE - c GROUND CONDUIT RUN UP THROUGH DEVICE OR FLOOR. LINE TYPE AND COLOR WILL VARY DEPENDING ON THE VOLTAGE AND INSTALLATION REQUIREMENTS CONDUIT RUN DOWN THROUGH DEVICE OR FLOOR. LINE TYPE AND COLOR WALL VARY DEPENDING ON THE VOLTAGE AND INSTALLATION REQUIREMENTS CONDUIT STUBBED UP AND CAPPED. LINE TYPE AND COLOR WILL VARY DEPENDING ON THE VOLTAGE AND INSTALLATION REQUIREMENTS HOME RUN TO PANELBOARD OR AS INDICATED CONDUIT RUN, BROKEN AND CONTINUED SAME SHEET OR AS NOTED n A A FLEXIBLE CONDUIT I CONDUIT WITH SEAL FITTING CONDUIT RUN. HATCH MARKS INDICATE NUMBER OF CONDUCTORS --�— CALLOUT INDICATING CONDUIT SIZE, NUMBER `)r GRC 2-11-2 AND SIZE OF WIRE CALLOUT INDICATING CONDUIT PER SCHEDULE 1W UNDERGROUND DUCT LINE (CONC. ENCASEMENT) O O O O UNDERGROUND DIRECT BURIAL CONDUITS O O O ^O TWISTED SHIELDED WRE W- s9ocoaF REVISED TO CONFORM TO CONSTRUCTION RECORDS p MARK JAK24. 2003 SCANNED OCT 0 v LeeSd R42 ENGINEERING INC. DATE toH� 011I m- 1p—mw ! {., 3 SIGNS& 11126,01 R1Ai. IFOSS � e SIGNBIt 11/26,01 W O H 1"' Z �z ��WRR O V z JJ A vy � v Lu E-4® V W m W ENGINEERS PLANNERS SCi ENTISTS RH2EMINEERINJ, . htWnw o en,h2.- I.6m72118M BELUN HAMOFFICE 36,1678.0576 454 WMt Hatm Rmd BOTHELL OFFICE 425951.5400 12100 1a In" u.as% es. too EASTW TCHEEOFFICE 5M8K2S00 300 T... Strc L SA 5 PORT ORCHARD OFFICE 360676.7960 600 Um St-L Suits 101 SCALE: SHOWN DRAWING IS NOT TO SCALE IF BAR IS NOT 2' LONG E -1