Loading...
HomeMy WebLinkAboutS-29001BINDICATE TYPI BY INSTRUMENT METER LETTER :;a� R. a w ' ELECTRICAL SYMBOLS LEGEND LINE TYPE LEGEND THERMAL MAGNETIC BREAKER �XL OC MOTOR OPERATION COUNTER OHP EXISTING OVERHEAD POWER u �\ `—° —O ST THERMAL OVERLOAD MAGNETIC BREAKER ONLY CIRCUIT BREAKER CIRCUIT BREAKER WITH CURRENT LIMITING FUSE FUSE SWITCH FUSE CUTOUT SHUNT TRIP EMERGENCY LIGHT WITH SELF CONTAINED BATTERY SINGLE RECEPTACLE, 120V SINGLE RECEPTACLE, 208V DUPLEX WALL RECEPTACLE , 120V WP = WEATHERPROOF G = GROUNDED IG = ISOLATED GROUND GF = GROUND FAULT INTERRUPTER DUPLEX FLOOR RECEPTACLE, 120V SSRVS 1�1 M SSRVS - SOLID STATE REDUCED VOLTAGE STARTER VARIABLE FREQUENCY DRIVE POWER TRANSFORMERJnlypy CONTROL POWER TRANSFORMER P -- , -- -- — FA SIGNAL — — EXISTING UNDERGROUND POWER EXISTING TELEPHONE PROPOSED TELEPHONE FIRE ALARM CONDUIT EXISTING SIGNALFUSED 120/240 VOLT WIRING 480 VOLT WIRING SIGNAL WIRING UNDERGROUND DIRECT BURIAL CABLE WIRING CONNECTED 18727 yyolareae °� �OIYAL �' EXPIRES e a o. SIGNED- ff /26/01 —(V F-- \J AM A - AMMETER VAR - VARMETER AH - AMPERE -HOUR VARH - VARHOUR METER PF - POWER FACTOR W - WATTMETER V - VOLTMETER WH - WATTHOUR METER VA - VOLT AMMETER L AgAG '� x22780 0' yot ea` 6XPiRES a la zoo4 SIGNED, 11126101 ABBREVIATIONS SPOT - SINGLE POLE, DOUBLE THROW SPST - SINGLE POLE, SINGLE THROW DPST - DOUBLE POLE, SINGLE THROW WP - WEATHER -PROOF GFI - GROUND FAULT INTERRUPT P - POWER C - CONTROL '. .'. SWITCH UNIT SUBSTATION, SWITCHGEAR, MOTOR CONTROL CENTER SURFACE MOUNTED PANELBOARD RATING IL WALL RECEPTACLE, AS NOTED J CEILING JUNCTION BOX O WAIL JUNCTION BOX TRANSFORMER CURRENT TRANSFORMER J - INSTRUMENTATION PC -POWER &CONTROL CJ - CCNTROL & INSTRUMENTATION , _ — _ — — — BUS CONDUIT CONCEALED BELOW GRADE, IN SLAB OR WALL. LINE TYPE COLOR WILL VARY DE ON VOLTAGE CONDUIT NDUIT AND WIRE EXPOSED OR SURFACE MOUNTED UNLESS OTHERWISE NOTED. LINE TYPE COLOR ELL VARY DEPENDING ON VOLTAGE NOTES GENERAL NOTE 1. THIS IS STANDARD LEGEND. NOT ALL OF THE INFORMATION SHOWN ON THIS PAGE MALI APPEAR IN THIS SET OF PLANS, �J VOLTAGE TRANSFORMER � � — V - -- - GROUND FLUSHED MOUNTED PANELBOARD CONDUIT RUN UP THROUGH DEVICE OR FLOOR. � FLOOR JUNCTION BOX THESE DRAWINGS ARE DIAGRAMMATIC ONLY, EXACT LOCATIONS OF ELECTRICAL EQUIPMENT n 0 LINE TYPE AND COLOR WILL VARY DEPENDING —O— M CONTROL STATION EQUIPMENT MOUNTING STAND SINGLE PHASE MOTOR.+ HORSEPOWER AS NOTED WALL TELEPHONE OUTLET ( +12 ") WALL TELEPHONE OUTLET ( +60 ") FLOOR TELEPHONE OUTLET ❑ 75WATTS �N/ P— l HEATER &— HEATER, WATTAGE NOTED UTILITY POLE AND GUY WIRE SH2. ALL BE DETERMINED IN THE FIELD BY THE ENGINEER, THE INSTALLATION OF ALL EQUIPMENT SHOWN ON THESE DRAWINGS OR DESCRIBED IN THE SPECIFICATIONS SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE LATEST EDITIONS OF ALL APPLICABLE CODES AND UTILITY COMPANY STANDARDS. CONTACT THE UTILITY COMPANY REPRESENTATIVES AND VERIFY THEIR REQUIREMENTS. 3. NOTIFY THE ENGINEER IMMEDIATELY IF CONFLICTS IN EQUIPMENT LOCATIONS ARE DISCOVERED REASON. NO PAYMENTEW9LL BE MADE FOR CONDITIONS. CHANGES WHICHFHAVE NOT INFORMATION FAVORABLY REVIEWED BY THE ENGINEER. ON THE VOLTAGE AND INSTALLATION REQUIREMENTS. CONDUIT RUN DOWN THROUGH DEVICE OR FLOOR. LINE TYPE AND COLOR WALL VARY REQUIREIMENTTS. THE VOLTAGE AND INSTALLATION CONDUIT STUBBED UP AND CAPPED. LINE TYPE AND COLOR WILL VARY DEPENDING ON THE VOLTAGE AND INSTALLATION REQUIREMENTS. N y ~ A O 1� Grp z N Uj W 75 HP />\\ St THREE PHASE MOTOR. HORSEPOWER AS NOTED MOTORIZED LOUVER ACTUATOR SAFETY SWITCH COMBINATION MOTOR STARTER AND SAFETY SWITCH MANUAL MOTOR STARTER FIRE ALARM PULL STATION FIRE ALARM FLASHING LIGHT r FIRE ALARM HORN r © OK ® --��— /�— `C'l ® POWER VAULT KIRK KEY INTERLOCK CONNECTION POINT, EXOTHERMIC WELD. CADWELD OR APPROVED EQUAL. PLUG -IN CONNECTION PIGTAIL, BARE COPPER, LENGTH AS REQUIRED, 8' MINIMUM CONNECTION POINT, MECHANICAL, COMPRESSION TYPE. CA a O lot CA -� �I,Ir� HOME RUN TO PANELBOARD OR AS INDICATED CONDUIT RUN, BROKEN AND CONTINUED SAME SHEET OR AS NOTED FLEXIBLE CONDUIT CONDUIT WITH SEAL FITTING OOF CONDUIT RUN. MARKS INDICATE NUMBER CONDUCTORS 7-. O ® H rr N' V2 V W "fy O E z go w N z 1;R7;i A of J M M J IWi >4 U �Uj: L Iw" M (j �° Q W V/ OEXOTHERMIC HH MH ® O5 ®3WAY GROUND ROD SIZED PER N.E.C. USE WELD CONNECTION AT THE GROUND ROD. MANHOLE OR HANDHOLE DISCONNECT SWITCH STANDARD SWITCH, 120VAC, 20 AMP 3 -WAY SWITCH, 120VAC, 20 AMP BELL u BUZZER HEAT DETECTOR O S SMOKE DETECTOR S TB CAPACITOR ENGINE GENERATOR GENERATOR CONNECTION RECEPTACLE SOLID NEUTRAL TERMINAL BLOCK O Q� Z d a1 O _c � 7 a Qv° r � GR C 2 - G` 2-#12 — 100 —� O O O —® T INDICATING CONDUIT SIZE, NUMBER A AND SIZE OF WIRE. CALLOUT INDICATING CONDUIT PER SCHEDULE UNDERGROUND DUCT LINE (GONG. ENCASEMENT) UNDERGROUND DIRECT BURIAL CONDUITS E Lj G 1 T V R FS RH2 ENGINEERING, INC. ltoP: *h2(n2.com m aSn oXanz. «n 1.800710.8052 ®HOA 4- POSITION SWITCH, 1 120VAC, 20 AMP, LABEL SWITCH POSITION HAND -OFF- MOTION -PHOTO END OF LINE RESISTOR LA �' C/] NIWO O O O O BELIi0 OFFICE 360.676.08336 6 454 west Horton Ro°e FLUORESCENT FIXTURE /�I-1 ARE ALARM CONTROL PANEL EALI- LIGHTING ARRESTOR � ---I EfC' TWISTED SHIELDED WIRE azOTHELL OFFICE NE 195th SUH Suite 100 —O c)-d II SURGE ARRESTER Z EAST W ENATGHEE OFFICE EA5 509.886.2900 300 5i— st—t, Sub 5 WALL /CEILING MOUNTED FIXTURE EOE INSTRUMENT METAL PIPE GROUND - - - -- - - - - - -- - - -� FORT ORCHARD RD OFFICE 360.876.796.79 60 600 Kitsap Street, Su to 101 M POLE MOUNTED FIXTURE GE ELECTRICAL PLUG MD MOTION DETECTOR LIMIT SWITCH O LIMIT SWITCH - SQUARE D HEAVY DUTY TYPE C, CLASS 9007 OR APPROVED EQUAL. SELECT ACTUATOR LEVER ARM BEST SUITED FOR MOUNTING ON ACCESS HATCH. - SCALE: SHOWN -� � 0 1" 2" WALL /CEILING MOUNTED EXIT LIGHT - D IRECTIONAL ARROW WHERE INDICATED SHADED AREA INDICATED ILLUMINATED FACE WALL /CEILING MOUNTED EMERGENCY LIGHT WITH REMOTE BATTERY rr 2 7 � � PC PHOTO CONTROL CELL O ® EYS EXPLOSION PROOF CONDUIT SEAL FITTING T CONTACTOR RTM MOTOR RUN TIME METER I 1 — GROUND VACUUM BREAK SWITCH SCANNINED Vv/9B ®�i �e CC OCT ® Q y Q 4. REVISED TO TO CONSTRUCTION MARK MILLER R12 ENGINEERING INC. CONFORM RECORDS JAN 24 2003 DATE DRAWING IS NOT TO SCALE IF BAR IS NOT 2" LONG aov 1 pwc xn E -1 unx� De mm. JA o4re JAN 24, 2003 "nGi "n J 10 mar; PAG ",uL- 101.082 RE�+u>EKCC -Et