HomeMy WebLinkAboutS-29002EWET WELL WET WELL TRANSDUCER. SEE DRY WELL DETAIL ON DWG NO. JG2. i I f iA PROPOSED ELECTRICAL 3' -8" L x 2' -8" W x 3' -6" H' ELECTRICAL VAULT FOR SPLICING JACKETED j CABLE TO BUILDING WIRE. UTILITY VAULT COMPANY MODEL # 233 —LA OR EQUAL. (TYPICAL). I i ELECTRICAL VAULT EYS CLASS 1 DIVISION 1 AREA 30VE GRADE LIMIT SWITCH TO TURN ON WITH OPEN ELECTRICAL ENCLOSURE DOORS. ZS4 o ZS5 OF 0 ELECTRICAL ENCLOSURE TELEMETRY ANTENNA. TO BE INTRUSION LIMIT SWITCH LOCATED IN THE FIELD DURING (TYPICAL EACH DOOR) CONSTRUCTION. ZS4 9 600 AMP BUS 480 VOLT 60Hz 30 3 WIRE 42,000 AIC TELEMETRY PANEL A8 - - 3P -30A ; 3P -30A 20A �______ I (PROVIDED BY CITY) C 480V ! 480V t r20A r1 i 142 KAIC 42 KAIC µ s NEUTRAL! 20A _ _ _,_ __._ L } RA POWER I _ { i j _____ METER _ 20A I(' j I ! 20A ( "� I i I 7 I� M2 -CPT I j — ' M1 —CPT '— 20A I I 3P -30A j I. NOTE 2 — ! NOTE 2 ( ( �� 20A �'� 480V K 42 KAIC E i I 2P -125A— 480V ` 104AT KAIC 42 ; �'I _ I � � i 125AF M2 —OL - ' M1 —OL , 1 _ — `' M K 1 480V — 5KVA j ©� 240/120V 10 i i -144AT }` '>-5 125AF Y, POWER RACEWAY SCHEDULE RACEWAY DESCRIPTION ORIGINATION TERMINATION Q 1 -1/4" GRC, 4 — #3 SERVICE DISCONNECT UTILITY METER 0 1 -1/4" GRC, 4 — #3 UTILITY METER MANUAL TRANSFER SWITCH Q 1 -1/4" GRC, 4 — #3 zj� PAD —MOUNT TRANSFORMER SERVICE DISCONNECT 0 1 -1/4" GRC, 4 — #3 MANUAL TRANSFER SWITCH GENERATOR CONNECTION RECEPTACLE A NOT USED — — A NOT USED — — Q NOT USED — — _8 2 — #12, 1 — #12 G TELEMETRY PANEL BREAKER Q 1/2" GRC, 2 — #12, 1 — #12G ELECTRICAL ENCLOSURE LIGHT BREAKER 0 1/2" GRC, 2 — #12, 1 — #12G WET WELL LIGHT BREAKER A 1/2" GRC, 2 — #12, 1 — #12G VALVE VAULT RECEPTACLE BREAKER Q 1/2" GRC, 2 — #12, 1 — #12G SUMP PUMP BREAKER A 1" GRC, 3 — #10, 4 — #14, 1 — #10G MOTOR N0. 1 MOTOR STARTER 0 1" GRC, 3 — #10, 4 — #14, 1 — #10G MOTOR NO. 2 MOTOR STARTER 0 2" GRC, PUMP 1 JACKETED CABLE MOTOR NO. 1 MOTOR STARTER 2" GRC, PUMP 1 JACKETED CABLE MOTOR NO. 2 MOTOR STARTER A 1" GRC, 6 — #14 FLOAT SWITCHES TELEMETRY PANEL A 1 -1/2" GRC, JACKETED CABLE LEVEL TRANSDUCER TELEMETRY PANEL Q 2" GRC, 3 —FLOAT CABLES FLOATS TELEMETRY PANEL A 1" GRC, 5 — #14, 1 — #12G VALVE VAULT DEVICES TELEMETRY PANEL 0 NOT USED — — Q ANTENNA CABLE TELEMETRY RADIO ANTENNA Q j 1/2" GRC, 2 - #14, 1 — #14G INTRUSION ALARM SWITCH TELEMETRY PANEL A71/2' GRC, 2 — #12, 1 — #12G GFI RECEPTACLE BREAKER ELECTRICAL EQUIPMENT LEGEND OA UTILITY METER ENCLOSURE — AS APPROVED B PUGET SOUND ENERGY. © GENERATOR CONNECTION RECEPTACLE — OUTDOOR RATED, 600V, 100A, 4 —POLE, 3 —WIRE, THREADED CAP, WEATHERPROOF. GROUSE HINDS MODEL NO. AREA10486 OR EQUAL THAT MATCHES CITY'S EXISTING PLUG. © TELEMETRY PANEL — PROVIDED BY CITY, INSTALLED THIS CONTRACT. PROGRAMMING AND CONNECTION TO MASTER BY OTHERS. CONNECT TO PROPOSED SENSORS, ALARMS, AND DEVICES. pO WALL MOUNTED INCANDESCENT FIXTURE — EXPLOSION PROOF, 120 VOLT, 150 WATT RATED. FURNISH WITH 150 WATT EXTENDED SERVICE LIGHT BULB. APPLETON PART NOS. AALB -75 (BRACKET), AAU -15N (FIXTURE UNIT), AAGU -1 (ALUMINUM GUARD) OR EQUALS. FURNISH ALL NECESSARY CONDUIT AND SEALS TO MEET EXPLOSION PROOF CRITERIA. MOUNT AS HIGH AS POSSIBLE ON WALL. O ELECTRICAL EQUIPMENT PANEL LIGHT FIXTURE — INCANDESCENT, 120 VOLT, 150 WATT RATED. FURNISH WITH 150 WATT EXTENDED LIFE BULB. HUBBELL MODEL VX -151 OR EQUAL. 0 LIMIT SWITCH FOR ACTIVATING PANEL LIGHT. SQUARE D HEAVY DUTY TYPE C, CLASS 9007 OR EQUAL. CONTRACTOR SHALL SELECT ACTUATOR LEVER ALARM BEST SUITED FOR MOUNTING CONFIGURATION. © INTRUSION ALARM SWITCH — SQUARE D HEAVY DUTY TYPE C, CLASS 9007 OR EQUAL. USE LIQUID TIGHT FLEXIBLE CONDUIT BETWEEN JUNCTION BOX AND LIMIT SWITCH. CONTRACTOR SHALL SELECT ACTUATOR LEVER ALARM BEST SUITED FOR MOUNTING CONFIGURATION. 0 CHECK VALVE POSITION LIMIT SWITCH — SQUARE D HEAVY DUTY TYPE C, CLASS 9007 OR EQUAL. USE LIQUID TIGHT FLEXIBLE CONDUIT BETWEEN JUNCTION BOX AND LIMIT SWITCH. SEE DETAIL ON DWG NO. G2. 0 FLOOD SWITCH — OMEGA MODEL LV -10 OR EQUAL. MOUNT TO END OF 1/4" PVC PIPE AND SECURE TO WALL WITH MINIMUM OF TWO STAINLESS STEEL PIPE CLAMPS. SWITCH SHALL TRIP AT 1/2- OF WATER LEVEL IN VAULT. © WET WELL LIGHT SWITCH — AC QUIET TYPE 20 AMP SINGLE POLE. ® TRANSIENT VOLTAGE SURGE SUPPRESSER — 6 "x6 "x6" NEMA 4 ENCLOSURE, ORION MODEL ORN -3Y 277/480V. NO SUBSTITUTION. 0 22780 �gGIST8g�9 EXPIRES 3M7200,1 SIGNED. 11126/( t E ... 1 16727 GrsT�';V IoN AL p _ EXPIRES 8/2/0' SIGNED. 11/26/'1 GENERATOR CONNECTION RECEPTACLE #6 BARE COPPER GROUND J ELECTRODE CONDUCTORS TO GROUND ELECTRODE PER N.E.C. 3/4"x8' LONG COPPER GROUND ROD (TYPICAL ONE ROD EACH E► SIDE OF ELECTRICAL �.�.. Als ENCLOSURE) h, w A2 :50 ::� %w KWH 0 ' Q H LL LLI ® --� LL 100 AMP FUSED SERVICE ENTRANCE SWITCH. Q 700 E y� MP z M /� O PAD —MOUNT TRANSFORMER N �, SECONDARY 48OV, 3— PHASE, 4W. W Z 0 2,. ctiil f� a ISA SYMBOL LEGEND LEVEL SWITCH LEVEL SWITCH SPDT LIMIT SWITCH LT LEVEL TRANSMITTER S-29003 REVISED TO CONFORM TO CONSTRUCTION RECORDS MARK MILLER JAN 24, 2003 RH2 ENGINEERING INC. DATE AS— BUILTS NO. REVISION r RH2 ENGINEERING INC. BELLINGHAM OFFI :E BOTHELL OFFICE EAST WENATCHEE OFFICE PORT ORCHARD O 'FILE SCALE: SHON d 0 1 2 DRAWING IS NOT TC SCALE IF BAR IS NOT 2" LONG PLOT: 24 DWG NO. ENGINEER: DMB E-2 REVIEWED: MM DATE: JAN 27, 2003 sHEE6o. CLIENT: PAG DJB MM 1/24/03 JOB NO.: 101.082 i0 BY REVIEW DATE FILENAME: KCC —E2 c�