DATUM ELEV.=
370.0
a
D
s
O 3
E_
U
9
� NWN a
-o
m
_y' C
v 1 0
2
4-
Q
�3 p
.n s�
E
Z SANITARY SEWER SYSTEM NOTES:
J 1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND
SPECIFICATIONS OF THE CITY OF RENTON UTILITY DEPARTMENT AND THE LATEST EDITION
L OF THE WSDOT /APWA STANDARDS AND SPECIFICATIONS.
F-
2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE LIMITED TO &30 A -M. TO
3:30 P.M. ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE
PLANNING /BUILDING /PUBLIC WORKS DEPARTMENT AT 235 -2620. ALL STREET CLOSURES,
PARTIAL OR FULL, SHALL BE APPROVED BY THE PLANNING /BUILDING /PUBLIC WORKS
DEPARTMENT 72 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911
SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ANY WORK IN THE RIGHT OF WAY.
3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH "STANDARD SPECIFICATIONS FOR
MUNICIPAL PUBLIC WORKS CONSTRUCTION" PREPARED BY WASHINGTON STATE CHAPTER
AMERICAN PUBLIC WORKS ASSOCIATION, LATEST EDITION (APWA) AND CITY OF RENTON
STANDARD SPECIFICATIONS.
4. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO
AVOID DAMAGE OR DISTURBANCE.
5. A PRECONSTRUCTION CONFERENCE AND A24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO
STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL
BE ACCOMPLISHED. BY A REPRESENTATIVE OF THE CITY OF RENTON -) IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE
OF BACKFILLING ALL CONSTRUCTION.
6. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE
MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND
OTHERS ON THE CONSTRUCTION SITE.
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY
OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION.
8. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT, SHALL TAKE
PRECEDENCE OVER ALL OTHER PLANS.
9. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION
IS IN PROGRESS.
10. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF
THE SANITARY SEWER SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED
PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR.
11. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A
LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING
EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND
FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH:
MATERIALS TO COMPLETE THE FILL OVER PIPE. SHALL BE THE SAME AS DESCRIBED.
12. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAY
SHALL BE BACKFILLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED.. CUTS INTO THE
ituu EXISTING ASPHALT SHALL BE NEATLINE CUT WITH SAW IN CONTINUOUS LINE. A
TEMPORARY MIX PATCH MUST BE PLACED IMMEDIATELY AFTER BACKFILL AND COMPACTION. A
PERMANENT HOT MIX PATCH SHALL BE PLACED WITHIN 10 DAYS AND SHALL. BE PER CITY OF
RENTON CURRENT STANDARDS.
13. DATUM SHALL BE CITY OF RENTON, U.S.C. AND G.S.
14. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED. TO
THE SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION AFTER
THE COMPLETION OF CONSTRUCTION.
15. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION
IN ACCORDANCE WITH SECTION 7- 02.3(1) OF THE CURRENT STATE OF WASHINGTON STANDARD
SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION.. THIS SHALL INCLUDE' NECESSARY
LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL AS WELL AS
PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT
THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE UNYIELDING
BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6" ABOVE AND BELOW THE PIPE.
16. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D
3034, SDR 35, OR DUCTILE IRON CLASS 50.
17. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCH AND MAXIMUM '18 INCH
ABOVE FINISHED GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO
MATCH PAVING.
408 - ..- ___— ___.__ ..__ __.._T___. _. _ __..______...408
404 — ___ �_ - -_ __— 40
4 _...
fT__ .__ __ . __.
3 Nid- [OJE2
430- .__`.._ _____. .. ------- _ __._� _..__ —. ____._.____._:. 400
Ov6(1. W C1i1L� 1i1�i
396
392
388
0 +00 1 +00 2 +00 3 +00 4 +00 S +UU o +uu
N.E. 6th STREET'
SCALE: HORIZ. 1 " =40'
VERT. 1 " =10'
W
Z
U
Q
7 +00 8 +00 9 +00 10 +00
VASHON AVE. N.E.
SCALE: HORIZ. 1 " =40'
VERT. 1 " =10'
z
American Engineers • Planners Surveyors
Engineering 4032 148th Ave. N.E.
Corporation Redmond, WA 98052 P
O PHONE .(425) 881 -7430 Fox (425) 881 - 7731_. --
178
396
392
388
S.,W.2956o4
387.97'
ro
0 +00 1 +00 2 +00 r� /0\
11 +00 12 +00 (V\
SANITARY SEWER CONNECTION �ti� �yoe�WA C/
SCALE: HORIZ. 1 " =40'
VERT. 1 " =10' ?Q s
0
cl _
R 33190 =4�
FSSFOISTER�'`V� -
IONAL E
RECOMMENDED FOR APPROVAL EXPIRES 05 -07 -2003
BENCHMARK —DATUM
BY: DATE:
CITY. OF RENTON #1937- SCRIBED "X" IN BACK OF CONC.
WLK MARKED "ESM 1411 NORTH SIDE, OF N.E. 4TH ST BY: DATE: SANITARY SEWER PROFILES
AT WEST BOUNDARY OF WINDSOR APTS.
ELEVATION= 403.72 / AND NOTES
A5 D BY. 5.��125i�5tL�DATE:, /J /� o� SHEET 10 of 15
t NAND 88 (CITY OF RENTON) 1 (� pQZZ9{�
' T CONTOUR INTERVAL =2 FEET BY: 11�AW QK�/ .DATE: Jqn. Z11007i AEC : #9UJC:
V �
LUA0029
SCAN NtU MAN G O Lwr,�p
SCANNED FEB 15 2002
;II
— - -- 1-30 -L
" -PVG SS-SWPE=
II
y — ___..;�L
SSM1F #6_48-W
-
.00 LT
CONNECT_TO _.
SSMH-
RIM 39677
--EX. TN "UT(S)_=38 837
EXIST: SSMH NOT CHANNELS
STA: 0 +33.57,
___RIM=39SU0
OUT= 389.0
_!NV
_ _
_
_-- CONSIRUC'F- CHANNEL —._
.___I__PER_CTY_OF_-RENTON.____ -_
j (SEE DETAIL SHEET 10)
M
h
396
392
388
S.,W.2956o4
387.97'
ro
0 +00 1 +00 2 +00 r� /0\
11 +00 12 +00 (V\
SANITARY SEWER CONNECTION �ti� �yoe�WA C/
SCALE: HORIZ. 1 " =40'
VERT. 1 " =10' ?Q s
0
cl _
R 33190 =4�
FSSFOISTER�'`V� -
IONAL E
RECOMMENDED FOR APPROVAL EXPIRES 05 -07 -2003
BENCHMARK —DATUM
BY: DATE:
CITY. OF RENTON #1937- SCRIBED "X" IN BACK OF CONC.
WLK MARKED "ESM 1411 NORTH SIDE, OF N.E. 4TH ST BY: DATE: SANITARY SEWER PROFILES
AT WEST BOUNDARY OF WINDSOR APTS.
ELEVATION= 403.72 / AND NOTES
A5 D BY. 5.��125i�5tL�DATE:, /J /� o� SHEET 10 of 15
t NAND 88 (CITY OF RENTON) 1 (� pQZZ9{�
' T CONTOUR INTERVAL =2 FEET BY: 11�AW QK�/ .DATE: Jqn. Z11007i AEC : #9UJC: