Loading...
HomeMy WebLinkAboutS-2987061QQA 3P J NEW SERVICE ENTRANCE DISCONNECT LOCATED ON BACKSIDE OF SHELTER. =f_v EXISTING MANUAL TRANSFER SWITCH ,100 PANEL A, 120/240. B PHASE IS THE HIGH LEG. NOTE: CONTRACTOR SHALL REMOVE EXISTING PUMP CONTROL PANEL AND RETURN TO CITY SHOPS. CONTRACTOR SHALL VERIFY SPACE REQUIREMENTS PRIOR TO ORDERING (PROPOSED PUMP CONTROL PANEL. 200 b) 60 A NEW UTILITY IV METER LOCATED 200 ON BACKSIDE OF •' - ^ r-, SHELTER, 20 AMP, 120 VOLT, GFCI. , 0 L}. _ _-o M 200 0 120 VOLT, 20 AMP RATED HOA LIGHT _ } 100 SWITCH. LOCATE SWITCH IN ELECTRICAL --'� ,.� 200 �1 E' BUILDING (TYPICAL). SEE LIGHTING �, T 00 CIRCUIT DETAIL THIS SHEET. 'J 0 200 00 ��. oo EXISTING SURGE PROTECTIVE ^ - EF DEVICE. CONTRACTOR TO „ RECONNECT AS SHOWN. NEW THREE PHASE 120/240 ( 1 VOLT SERVICE WITH 208 EXISTING EMERGENCY POWER GENERATOR 200 241 221 - - VOLTS AVAILABLE FROM RECEPTACLE. CONTRACTOR SHALL RELOCATE ABOVE GRADE PHASE C TO NEUTRAL. ON OUTSIDE OF ELECTRICAL ENCLOSURE. ENE -LINE DIAGRAMI TO UTILITY POWER. NO SCALE L j REVISED TO CONFORM TO CONSTRUCTION RECORDS MARK MILLER, P.E. 1/24,/06 RH2 ENGINEERING INC. DATE ELECTRICAL EQUIPMENT LEGEND Ao OUTSIDE AREA LIGHT - 10OW METAL HALIDE, 120 VOLT BALLAST, STONCO MODEL NO. PM A 250 MA 8, WITH 12 FOOT SQUARE ALUMINUM POLE, VALMOUNT MODEL NO. 1200 -40 40 4 N 4 Dl DDB. PROVIDE MOTION SENSOR WITH POTOCELL FEATURE AND ALL MOUNTING HARDWARE AND BASE PER MANUFACTURER'S RECOMMENDATION. ORIENTATE TO ILLUMINATE DRY WELL HATCH. SEE LIGHTING CIRCUIT DETAIL THIS SHEET FOR MORE INFORMATION. B FLOW METER - SEE SPECIFICATIONS FOR DETAILS. C WET WELL LEVEL TRANSMITTER - SEE SPECIFICATIONS FOR DETAILS. FLOOD SWITCH - SEE SPECIFICATIONS FOR DETAILS. Eo SHELTER LIGHT - 120 VAC, LITHONIA CATALOG NO. DM 2 32WT8 AR 120 GEB, OR EQUAL. ATTACH TO CEILING INSIDE SHELTER. F PRESSURE TRANSMITTER - SEE SPECIFICATIONS FOR MORE INFORMATION. G EXHAUST FAN - 120 VAC, 1 PHASE, & HP H WALL - MOUNTED COOLING THERMOSTAT - SNAP ACTION, SPST LINE VOLTAGE AIR SWITCH CONTROLLER RATED FOR Y HP MOTOR. RANGE: - 30• -100T SET AT 757, HONEYWELL MODEL NO. T631 C1103 OR EQUAL. LOCATION AS APPROVED BY ENGINEER. K FLOAT SWITCH - NORMALLY CLOSED. NEW PUMP CONTROL PANEL. • A TELEMETRY PANEL. • w K�c -rrn ruw-rni i j• � � • LSO �JaJ TRANSIENT VOLTAGE SURGE 60 AMP LOAD PANEL. PROTECTOR. NEW ELECTRICAL ENCLOSURE NO SCALE NEMA 3R JUNCTION BOX, SIZE PER NEC (TYPICAL). L YFT PT DI'1'WEILVAULT 0 ■ m EXISTING TELEMETRY CONTROL PANEL. 225 New rutip CONTpol- �15A 3P M1 --CPT j___— TM OC �. ESTOP CPlL_� SFIL OTIL HLIL 120V HAND SWITCH OFF AUTO r MOTION DETECTOR PHOTO CELL OUTDOOR LIGHTING CIRCUIT DETAIL BELOW GRADE NO SCALE s - 2 OG STANDARD CABLE/CONDUIT SCHEDULE MARK CONDUCTORS GROUND CONDUIT MARK CONDUCTORS GROUND CONDUIT MARK CONDUCTORS CONDUIT 100 (3) - #3 (1) - #3 1 1/2 220 (2) - #14 (1) - #14 1/2- 240 (1) -2- CONDUCTOR SHIELDED CABLE 3/4" a 221 (4) - #14 (1) - #14 1/2" 241 (2) -2- CONDUCTOR SHIELDED CABLE 3/4" 222 (6) - #14 (1) - #14 1/2" 242 (3)- 2- CONDUCTOR SHIELDED CABLE 3/4" 200 (2) - #12 (1) - #12 1/2" 223 (8) - #14 (1) - #14 3/4" 243 (4)- 2- CONDUCTOR SHIELDED CABLE 3/4" 201 (3) - #12 (1) - #12 1/2" 224 (10) - #14 (1) - 114 3/4" 244 (5) -2- CONDUCTOR SHIELDED CABLE 1" 202 (2) -- #10 (1) - #10 112" 225 (12) - #14 (1) - 114 3/4" 245 (6) -2- CONDUCTOR SHIELDED CABLE 1 1/4- 203 (3) - 110 (1) - #10 3/4" 226 (14) - #14 (1) - #14 1" 246 (7)- 2- CONDUCTOR SHIELDED CABLE 1 1/2 204 (2) - 18 (1) - #10 3/4" 227 (16) - #14 (1) - 114 1" 247 (8) -2- CONDUCTOR SHIELDED CABLE 1 1/2" 205 (3) - 18 (1) - 110 3/4" 228 (18) - #14 (1) - 114 1" 248 (9) -2- CONDUCTOR SHIELDED CABLE 2" 206 (2) -16 (1) - #10 1" 229 (20) - #14 (1) - 114 1" 249 (10)- 2- CONDUCTOR SHIELDED CABLE 2" 207 (3) -16 (1) - #10 In 230 (24) - #14 (1) - 114 1 1/4" 250 (1) -3- CONDUCTOR SHIELDED CABLE 1" 208 (2) -16 (1) - 18 1" 231 (25) - #14 (1) - 114 1 1/4" 251 (1) -4- CONDUCTOR SHIELDED CABLE 1" 209 (3) -#6 (1) - #8 1" 232 (30) - #14 (1) - #14 1 1/4" 252 MANUFACTURER'S CABLE 112" 210 (3) - #4 (1) — #8 1 1/4" 233 (32) - #14 (1) - #14 1 1/4" 253 TELEPHONE CABLE (1 -PAIR) 112" 211 (3) - #3 (1) - #8 1 1/4" 234 (36) -#14 (1) - 114 1 1/4" 254 TELEPHONE CABLE (2 -PAIR) 1/2" 212 (3) - 12 (1) -#6 1 1/2" 235 (40) - #14 (42) - #14 (1) - 114 (1) - 114 1 1/4" 1 112" 255 256 TELEPHONE CABLE (4 PAIR) TELEPHONE CABLE (6 -PAIR) 3/4" 1" 213 (3) - #1 (1) -#6 1 1/2" 236 214 (2) - #8 1/2" 237 (4$) - 114 (1) - #14 1 112" 257 NETWORK CABLE 1" 2XX 2XX DENOTES COMMON CONDUIT (INCREASE CONDUIT SIZE IF REWIRED). ROLL 2 01+1'2 L1 > o-i�o-! L2 I � L3 t i CIRCUIT BREAKER CL 0 i W PUMP CONTROL DIAGRAM LINE REACTORS ,-- VFD 240 VAC TO 120 VAC TR1 VFD- CONTROL MODULE CALL CR1 �.a OL T1 XT2 y� T3 SEE 0 &M MANUAL FOR CONTROL LOGIC AS- BUILTS FROM PANEL MANUFACTURER. r, w �c CPR 100/1, FAN CR1 0 FRTm�- '= OC — 120VAC 1-11 I FNM 1/2 24VAC FNM 1/2 2 10 o- RESET 6 7 CONTROL POWER ON ---CPR POIAER FAIL TO* TELEMETRY I - - _ _ - - - --i M7- 17B COOLING FANS AS REQUIRED. VFD RUN CR1 I - -� -- TELM- TB I PUMP RUN TO TELEMETRY i - - - - -- TAM -TB VFD FAIL CR2 I I PUMP FAIL TO TELEMETRY I I - - - - -- -TEL ELAPSED TIME METER OPERATION COUNTER El( WS 3 SIGN19 10192104 sierra 10142ib4 • t \NTO� ' DorD­ SENSORT2 MOTOR - _ - CR3 - - - TEEM TB -•" r Tl OUTPUT 5 ;.� I - I HIGH TEMPERATURE TO RUGID 1 HIGH TEMP 3 I _____o I L--- - - - - -- M T9 E N G I N E E R S 4 PLANNERS CR4 SCIENTIST5 11 LEAKAGE g TE M � I RH2 ENGINEERING. INC. I SEAL FAIL TO RUGID 8 �------------ __4TTELM -TB MC MC BELLINGIHAM OFFICE 1 3 11 $ CR3 MOTOR HIGH TEMPERATURE ' r. BOTHELL OFFICE MC 4. 1 4 9 CR4 PUMP MOISTURE EAST WENATCHEE OFFICE PUMP CALL CR3 CR5 PORT ORCHARD OFFICE no- 1 � = 1 .� TR1 INTERPOSE RELAY 100 SET DELAY FOR 10 SECONDS �. CR 5 __ LOW LEVEL FLOAT r - - TEEM -TB -- r-- CR5 I - � � SCALE: SHOWN �4 `a'� '�'? 1 LOW LEVEL TO RUGID wm I _' T -TB 0 CR3 ----- - - - --- �R� km2� " —a-� HIGH TEMPERATURE LIGHT DRAWING IS NOT TO SCALE IF BAR IS NOT 2 "LONG CR4 1 PLOT 1 w N0 ---o- R , SEAL FAIL LIGHT ENOWM CMR E02 CR5 � REWWD MI.M R LOW LEVEL LIGHT iT im »< JAN 31, 2006 SET ;; ual- REN 6 xe w 102 -036 JF8 2 REVISED TO CONFORM TO CONSTRUCTION RECORDS D,� MM 1 /24/06 N0. BY REVIEW DATE Ito~ FLSH -DO5 2 58 7U to SCANNED MAY 0 12006 n a4 a 0 z, k�4 9 0 Z O Q J 0 Q � a �ui o z z o° J ia- W UN Z O um J O O N ' DorD­ SENSORT2 MOTOR - _ - CR3 - - - TEEM TB -•" r Tl OUTPUT 5 ;.� I - I HIGH TEMPERATURE TO RUGID 1 HIGH TEMP 3 I _____o I L--- - - - - -- M T9 E N G I N E E R S 4 PLANNERS CR4 SCIENTIST5 11 LEAKAGE g TE M � I RH2 ENGINEERING. INC. I SEAL FAIL TO RUGID 8 �------------ __4TTELM -TB MC MC BELLINGIHAM OFFICE 1 3 11 $ CR3 MOTOR HIGH TEMPERATURE ' r. BOTHELL OFFICE MC 4. 1 4 9 CR4 PUMP MOISTURE EAST WENATCHEE OFFICE PUMP CALL CR3 CR5 PORT ORCHARD OFFICE no- 1 � = 1 .� TR1 INTERPOSE RELAY 100 SET DELAY FOR 10 SECONDS �. CR 5 __ LOW LEVEL FLOAT r - - TEEM -TB -- r-- CR5 I - � � SCALE: SHOWN �4 `a'� '�'? 1 LOW LEVEL TO RUGID wm I _' T -TB 0 CR3 ----- - - - --- �R� km2� " —a-� HIGH TEMPERATURE LIGHT DRAWING IS NOT TO SCALE IF BAR IS NOT 2 "LONG CR4 1 PLOT 1 w N0 ---o- R , SEAL FAIL LIGHT ENOWM CMR E02 CR5 � REWWD MI.M R LOW LEVEL LIGHT iT im »< JAN 31, 2006 SET ;; ual- REN 6 xe w 102 -036 JF8 2 REVISED TO CONFORM TO CONSTRUCTION RECORDS D,� MM 1 /24/06 N0. BY REVIEW DATE Ito~ FLSH -DO5 2 58 7U to SCANNED MAY 0 12006 n a4 a 0 z, k�4 9 0