HomeMy WebLinkAboutT-2211123 ° i ° w u, i ao N aD /i �<° 0 a�tim a ..Zz m Soot PHASING SEQUENCE SIGNAL HEAD DISPLAY LEGEND 12" O RED 12- O YELLOW 12" O RED 12" � YELLOW 12" e RED 12" Q YELLOW 1 1 12 EXIST. PROPOSED - 10 VEHICLE MOVEMENT ( CONDUIT AND WIRING SCHEDULE (SEE GENERAL NOTE 4) 18 17 16 15 14 ® ® SIGNAL CONTROLLER ► PEDESTRIAN MOVEMENT 12" 9 GREEN O INSTALL TYPE III SERVICE CABINET AND ASSOCIATED EQUIPMENT ON NEW FOUNDATION. D RELOCATE EXISTING LUMINAIRE POLE ON NEW FOUNDATION AT SAME STATION 60.5' LT. ® INTERCEPT EXISTING CONDUIT ® APPROXIMATELY STA. 16 +28 AND EXTEND CONDUIT INTO NEW JUNCTION BOX. SPLICE NEW WIRING TO EXISTING ® ® SERVICE CABINET ao RUN NO RACEWAY 1 DET EMPT SIG HD ® ® JUNCTION BOX - TYPE 1 ILL F#2 OWER 21,22,23 PAIRS 2CS m O JUNCTION BOX - TYPE 2 16 6PRCC #8 I �7 �8 m 0 JUNCTION BOX - TYPE 3 02 06 1 !- �u -�'�p SIGNAL POLE WAUMINAIRE ARM EMERGENCY I +X LUMINAIRE POLE VEHICLE PREMPTION l- co- PEDESTRIAN POLE CHANNEL A = 02 1 03 04 _)E xi­ EMERGENCY PREEMPTION DETECTOR CHANNEL B = 06 CHANNEL C = 04 +07 °"- �*'- PEDESTRIAN SIGNAL HEAD CHANNEL D = 03 +08 VEHICLE SIGNAL HEAD GENERAL NOTES DRAWING NO. DATE APPROVED: SHEET: 18 OF: 28 VEHICLE SIGNAL HEAD 1. ALL VEHICLE HEADS SHALL BE CONVENTIONAL HEADS BY SIGN ON MAST ARM WITH TUNNEL VISORS AND SQUARE DOORS. 1-1 F841 6' X 6' INDUCTION LOOP 2. ALL PEDESTRIAN HEADS SHALL BE FIBER OPTIC HEADS _ _ — CONDUIT AND WIRE WITH TYPE E MOUNTIING HARDWARE. 3. SEE SHEET 6 FOR SIGNAL REMOVAL ITEMS. ®1 POLE NUMBER 4. ALL CONDUITS UNDER TRAVELED ROADWAYS SHALL BE Ot CONSTRUCTION NOTE SCHEDULE 80 PVC. ALL OTHER CONDUITS MAY BE SCHEDULE 40 PVC. f 11 WIRE NOTE Q 5. SEE SHEET 22 FOR SIGN DETAILS O SIGN INSTALLATION NOTE .1 m b ° ($EE SHT. 22) 12 "D e, 10kq.� 1� I ISR900 13 +8.93 P,O.C. R _ I K 13 +87.92 P.O.T, I i R /6 ( ¢ I14 SR900 13 +68.55 P.T, I( TYP. 1 �z' 10 . I D m `� MUM-0011"11119 5-7900 11 +54.62 P.C. K 13 +97.18 P.C. -------------------- - - - - -- ----- - - - - -- I ----------- - - - - -- 96SUNSET BLVD. N. 154' °0 TYP. co 10 W m N 0 IN 16 SIGNAL HEAD DISPLAY ��v- sro -z2a 12" O RED 12- O YELLOW 12" O RED 12" � YELLOW 12" e RED 12" Q YELLOW 1 1 12 I d Al, I I I I I I I A CONDUIT AND WIRING SCHEDULE (SEE GENERAL NOTE 4) 18 17 16 15 14 #12 10 9 8 7 6 PRE— 12" 9 GREEN O INSTALL TYPE III SERVICE CABINET AND ASSOCIATED EQUIPMENT ON NEW FOUNDATION. D RELOCATE EXISTING LUMINAIRE POLE ON NEW FOUNDATION AT SAME STATION 60.5' LT. ® INTERCEPT EXISTING CONDUIT ® APPROXIMATELY STA. 16 +28 AND EXTEND CONDUIT INTO NEW JUNCTION BOX. SPLICE NEW WIRING TO EXISTING TER— VEHICLE VEHICLE ao RUN NO RACEWAY TWISTED DET EMPT SIG HD POWER C ILL F#2 OWER 21,22,23 PAIRS 2CS 3CS 5C 16 6PRCC #8 SIGNAL &ILLUMINATION PLAN 16 `.� - L . 0 a a a 0 e ^�� ,,f�I.c� t 1 �► /5\ A8 - / O /. m It ' SIGNAL HEAD DISPLAY ��v- sro -z2a 12" O RED 12- O YELLOW 12" O RED 12" � YELLOW 12" e RED 12" Q YELLOW 1 1 12 I d Al, I I I I I I I A 9 18 17 16 15 14 13 12 11 10 9 8 7 6 `.� - L . 0 a a a 0 e ^�� ,,f�I.c� t 1 �► /5\ A8 - / O /. m It ' "4. 16+00 NSE 13 N. SR9 — — SIGNAL HEAD DISPLAY � 12" O RED 12- O YELLOW 12" O RED 12" � YELLOW 12" e RED 12" Q YELLOW 1 1 12 O P 12" O GREEN 12" GREEN 12" ® GREEN a 20 0 20 40 1"=20' MMENIM011 SCALE FEET 22 23 B 12" 9 GREEN O INSTALL TYPE III SERVICE CABINET AND ASSOCIATED EQUIPMENT ON NEW FOUNDATION. D RELOCATE EXISTING LUMINAIRE POLE ON NEW FOUNDATION AT SAME STATION 60.5' LT. ® INTERCEPT EXISTING CONDUIT ® APPROXIMATELY STA. 16 +28 AND EXTEND CONDUIT INTO NEW JUNCTION BOX. SPLICE NEW WIRING TO EXISTING 10 TYP. VEHICLE VEHICLE VEHICLE PEDESTRIAN SIGNAL HEADS SIGNAL HEADS SIGNAL HEADS SIGNAL HEADS 1,4,5,6,8,11,12,13,14 2,9 3,7,10,15 16,17,18,19,20, 15 NEW CONDUIT, SPLICE. 16 SEE SHEET 21 FOR CONTINUATION OF CONDUIT RUN. 17 DISCONNECT EXISTING LOOP DETECTOR. 21,22,23 "4. 16+00 NSE 13 N. SR9 — — Y I I A I I IA I I I IA I I I I l Zi I'm R0 OX 6 7 8 .9 10 11 12 13 14 15 16 17 18 19 4 - L7 1 � I PLANTER 1 1 12 P 1T`R 2 11 L a �r�x x� —a o 0. ° a 20 0 20 40 1"=20' MMENIM011 SCALE FEET 22 23 B i 11 ACP 2 12 CONSTRUCTION NOTES INSTALL TYPE III SIGNAL POLE COMPLETE WITH LUMINAIRE ARM AND 250 WATT HPS 240 VAC TYPE III MED. CUTOFF FIXTURE 9 MOUNTED AT 35 FEET. INSTALL 42 FOOT MAST ARM WITH FOUR VEHICLE HEADS USING TYPE "L' MOUNTING AND ONE EMERGENCY O INSTALL TYPE III SERVICE CABINET AND ASSOCIATED EQUIPMENT ON NEW FOUNDATION. D RELOCATE EXISTING LUMINAIRE POLE ON NEW FOUNDATION AT SAME STATION 60.5' LT. ® INTERCEPT EXISTING CONDUIT ® APPROXIMATELY STA. 16 +28 AND EXTEND CONDUIT INTO NEW JUNCTION BOX. SPLICE NEW WIRING TO EXISTING 10 TYP. PREEMPTION DETECTOR . INSTALL TWO PEDESTRAIN HEADS AND TWO PEDESTRIAN PUSHBUTTON ASSEMBLIES. INSTALL ONE VEHICLE HEAD ON SIGNAL POLE USING TYPE K MOUNTING AND ONE TERMINAL CABINET. TO MAINTAIN CIRCUIT CONTINUITY. O RELOCATE EXISTING SIGNAL POLE AND EMERGENCY PREEMPTION DETECTOR AT SAME STATION. INSTALL NEW FOUNDATION. 2 7 / f 7 ¢ X O2 INSTALL TYPE III SIGNAL POLE COMPLETE WITH LUMINAIRE ARM AND 250 WATT HPS 240 VAC. TYPE III MED. CUTOFF FIXTURE MOUNTED AT 35 FEET. INSTALL 32 FOOT MAST ARM WITH THREE VEHICLE HEADS USING TYPE "L" MOUNTING, AND TWO EMERGENCY PREEMPTION DETECTORS. INSTALL TWO PEDESTRIAN HEADS, TWO PEDESTRIAN PUSHBUTTON ASSEMBLIES AND ONE TERMINAL CABINET. 3O INSTALL TYPE Ili SIGNAL POLE COMPLETE WITH LUMINAIRE ARM 410 INSTALL 6'x6' LOOP DETECTOR. 11 BRING RING NEW CONDUIT INTO SPLICE NEW ILLUMININAT EXISTING STING JUNCTION BOX WIRING TO EXISTING TO MAINTAIN CIRCUIT CONTINUITY. 12 COORDINATE WITH PUGET POWER FOR POWER CONNECTION FROM VAULT. 13 REMOVE EXISTING HOME RUN CABLE AND SPLICE a < 15 +19.98 P.T. AND 250 WATT HPS 240 VAC. TYPE III MED. CUTOFF FIXTURE MOUNTED AT 35 FEET. INSTALL 42 FOOT MAST ARM WITH FOUR VEHICLE HEADS USING TYPE "L" MOUNTING AND ONE NEW CABLE TO EXISTING LOOP WIRES. 14 BRING NEW CONDUIT INTO EXISTING JUNCTION BOX. / f coNOV2 Aao ✓ucTroN BOX.W(T,% /!J BOXED AREAS W /LL BB OONE BY OTHERS EMERGENCY PREEMPTION DETECTOR. INSTALL TWO PEDESTRIAN HEADS, TWO PEDESTRIAN PUSHBUTTON ASSEMBLIES, AND ONE TERMINAL CABINET. - O INSTALL TYPE COMPLETE 15 NEW CONDUIT, SPLICE. 16 SEE SHEET 21 FOR CONTINUATION OF CONDUIT RUN. 17 DISCONNECT EXISTING LOOP DETECTOR. WATTIHPS 240 VAC. TYPEIII UTOMFNFIXTURE y�9 Wr e�� 1ca�'Gi MOUNTED AT 35 FEET. INSTALL 35 FOOT MAST ARM WITH THREE VEHICLE HEADS USING TYPE "L" MOUNTING. INSTALL TWO PEDESTRIAN HEADS, TWO PEDESTRIAN PUSHBUTTON CITY OF RENTON DEPARTMENT OF PUBLIC WORKS " °� �z / 4 �6Mo -tom �wti4 � �`VS�ONAL E�Dl ASSEMBLIES AND ONE TERMINAL CABINET. 5 INSTALL TYPE P CONTROLLER CABINET AND ASSOCIATED EQUIPMENT ON NEW FOUNDATION. N.E. 3RD STREET (N.E. 3RD ST. /SUNSET BLVD. — SR900) SIGNAL &ILLUMINATION PLAN 6 E%PIRES 9/t6/96 DESIGNED: CE DATE: 11/18/94 FILE NAME: DRAWN: DJ /6x90 AN ALPHA Engineering Group, Inc. CHECKED: AM SCALE: 1" = 20' DRAWING NO. DATE APPROVED: SHEET: 18 OF: 28 NO. REVISION BY APPR. Y I I A I I IA I I I IA I I I I l Zi I'm R0 OX 6 7 8 .9 10 11 12 13 14 15 16 17 18 19 4 -