Loading...
HomeMy WebLinkAboutT-274901ti M1 ZINV N N Z O 1 � a ® 4 U l o I� m 1 Z 0 Z_ rn H U) wZ 0 LJ CL LLI Z F- 0- Q Q _ C' Q J W J J Z LLJ Z <LV N O O OD ao do ow N d O of E-I 3 a 1� n i-- CL o c E \E y �N C O y a� "s s� o = N zg n � ?% m 3 Of CL 0. w G m 0 w 0 3js PART ( O \ / I / _ N_ 1242 "W PUBLIC 8 "0 ® 0.4% VERIFY x X fP��" — �° 11 �'1c S S -_ --- s-'� 317 - ` - - 3199- _x =x I z- -318 � I 1 I / II / Lv \J i } o � \ 777/1 o \ O N \ CHANTELLE APARTMENTS NW 1/4 Or SECTION 16, TOWNSHIP 23N, RANGE 5E, WM NOTE: SEE ARCHITECTUAL DRAWING SHEET "A2" FOR TYPICAL BERM DETAIL AT BUILDINGS. ;p I @- --- \ s �� \\ 1 1/2" PVC CONDUIT.? FH p289 �� / / \ TBM TOP NUT / / EL 320.76 /// p cl EJ All CpNCR V / Cos s / NEW STREET LIGHT (STA- W / (SEE NOTE TE 3A 3A) ) y y I.D. #3231H 4 I I ._. 94 PRE -APP 98 -29 NOTES: 1. COMPLY WITH CITY OF RENTON "GUIDELINES AND STANDARDS FOR STREET LIGHTING DESIGN OF RESIDENTIAL AND .ARTERIAL STREETS ": HEREAFTER, REFERRED TO AS "THE STANDARD" 2, COMPLY LATEST EDITION OF THE NEC AND LOCAL CODES AND ORDINANCES. 3. SCOPE OF WORK: A. PROVIDE ONE (1) STREET LIGHTING STANDARD WITH 40OW HIGH PRESSURE SODIUM COBRAHEAD FIXTURE (G.E. M40OA2 FLAT LENS) ON 35' ANCHOR BASE POLE. (SEE DETAIL SHEET) B. PROVIDE HANDHOLE AT EACH POLE BASE WITH INTEGRAL 4" PAD OVER ANCHOR BASE. C. PROVIDE COMPLETE CONDUIT AND WIRING SYSTEM. 4. BURY ALL CONDUIT A MINIMUM OF 24" BELOW GRADE. ALL CONDUIT SHALL BE 1 1/2" PVC WITH (2) #8 CU THW CONDUCTORS AND (1) #10 CU GROUND. CONDUIT SHALL BE SCHEDULE 40 PVC. ALL NEW CONDUITS SHALL BE BURIED UNDER NEW, EXISTING AND FUTURE SIDEWALK LOCATIONS FOR PROTECTION. 5. INSTALL GROUND RODS AND SPLICES IN J -BOXES AND IN -LINE FUSES IN HANDHOLE AT EACH POLE. 6. LUMINAIRE - G.E. M -400A CUT OFF WITH FLAT LENS FOR 150W AND 40OW HIGH PRESSURE SODIUM LAMP WITH REGULATOR BALLAST RATED FOR 240 VOLT OPERATION. IES PATTERN M -S -11 OR 111. SEE SPECIFICATIONS. 7. COORDINATE INSTALLATION WITH EXISTING UNDERGROUND UTILITIES. THE NEW POLE FOUNDATION ELEVATION MUST BE FLUSH WITH THE BACK OF SIDEWALK. 8. COMPLY WITH THE NATIONAL ELECTRICAL SAFETY CODE CONCERNING REQUIRED CLEARANCES BETWEEN NEW LIGHTING STANDARDS AND PSP &L DISTRIBUTION AND TRANSMISSION LINES. 9. CONSTRUCTION NOTES: A. THE CONTRACTOR SHALL SUBMIT A REQUEST FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE. B. AS -BUILT DRAWINGS WILL BE REQUIRED ON COMPLETION OF ALL PROJECTS. C. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITIES AND THE CITY IMMEDIATELY UPON DAMAGE. LUMINAIR SCHEDULE LUMINAIRE CHANTELLE PLACE 2800 N.E. 3rd STREET C/L OF POLE TO ARM CIRCUIT CIRCUIT NUMBER POLE LOCATION C/L OF ROAD LENGTH NUMBER REMARKS 3232 H STA. 35 +58 39' LT 8' P -1 TYPE M -S -111 DISTRIBUTION RECOMMENDED FOR APPROVAL BY IL-17— BY BY _ Cb: 7 ?o/ �04= DEVELOPER: ANNETTE DEMPS 2308 N.E. 24th STREET RENTON, WA 98056 (425) 226 -6632 SITE ADDRESS: ARCHITECT: CHANTELLE PLACE 2800 N.E. 3rd STREET FALL ARCHITECTURAL RENTON, WA 98056 4115 S.W. 106th STREET SEATTLE, WA 98146 (206) 431 -7960 VERTICAL DATUM CITY OF RENTON ENGINEER: B.M.— MON #1936 ® N.E. 4th ST. & JEFFERSON AVE N.W. JOHAN DYE P.E. 12202 PACIFIC AVE S ELEV.— 99.483M = 326.304 SHEET No. TACOMA, WA 98444 (253) 537 -8128 THIS PLAN SET IS NOT A SURVEY. C._