Loading...
HomeMy WebLinkAboutR-276503STO ORMWATER DRRE ANY AINAGE PM� AC1. TIVITY OCCURS. A PRECONSTRUCTION ®JlRADIN-t-wJ AND STORM ®C.Y', DRAINAGE PLAN MEETING MUST BE HELD WITH THE CITY OF RENTON DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER. A PORTION OF SOUTHWEST 1/4 CITY SOUTHWEST 1/4, SECTION 3, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. 2. ALL CONSTRUCTION SHALL DE IN ACCORDANCE PAL THE RUCTI STANDARD CI 1 OF RELATION, KING COUNTY, WASHINGTON . �r'cCiFK:A710NS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION' PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATIONS (APWA), AS AMENDED BY THE CITY OF RENTON DEPARTMENT OF PUBLIC WORKS. 3. THE STORM DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS WHICH ARE ON FILE IN THE DEPARTMENT OF PUBLIC WORKS. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER OR STORM WATER UTILITY. 4, A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 5. DATUM SHALL BE U.S.G.S UNLESS OTHERWISE APPROVED BY CITY OF RENTON DEPARTMENT OF PUBLIC WORKS. REFERENCE BENCHMARK AND ELEVATION ARE NOTED ON THE PLANS. 6. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND THEY MUST BE SATISFACTORILY MAINTAINED; UNIIL CONSTRUCTION IS COMPLETED AND THE POT04W FOR ON -SITE EROSION HAS PASSED. 7. ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS, STORM WATER UTILITY. 8. GRASS SEED MAY BE APPLIED BY HYDROSEEDING. THE GRASS SEED MIXTURE, OTHER THAN CITY OF RENTON APPROVED STANDARD MIXES, SHALL BE SUBMITTED BY A LANDSCAPE ARCHITECT AND APPROVED BY THE DEPARTMENT OF PUBLIC WORKS, STORM WATER UTILITY. 9. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARE FOUNDATION IN ACCORDANCE WITH SECTION 7-02.3(1) OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION REQUIRED BEDDING MATERIAL MATERIAL AS WELL AS PLACEMENT AND COMPACTION OF RE Q TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS "C; WITH THE EXCEPTION OF PVC PIPE ALL TRENCH BACKFILL SHALL BE COMPACTED TO MINIMUM 95 PERCENT FOR PAVEMENT AND STRUCTURAL FILL AND 90 PERCENT OTHERWISE PER ASTM D-1557-70. PFA GRAVEL BEDDING SHALL BE 6 INCHES AND OVER AND UNDER PVC PIPE 10. GALVANIZED STEEL PIPE AND ALUMINIZED STEEL PIPE FOR ALL DRAINAGE FACILITIES SHALL HAVE ASPHALT TREATMENT /1 OR BETTER INSIDE AND OUTSIDE 11. STRUCTURES SHALL NOT BE PERMITTED WITHIN 10 FEET OF THE SPRING LINE OF ANY STORM DRAINAGE PIPE, OR 15 FEET FROM THE TOP OF ANY CHANNEL BANK. 12. ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FELT BELOW PAVEMENT LEVEL 13. OPEN CUT ROAD CROSSINGS AND EXISTING PUBLIC RIGHT-OF-WAY WILL NOT BE ALLOWED UNLESS SPEaRCA LY APPROVED BY CITY OF RENTON DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER. 14. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHAH BE OF SOUND QUARRY ROCK PLACED TO A. DEPTH OF 1 FOOT AND MUST MEET THE FOLLOWING SPECIFICATIONS: 4 INCHES TO 8 INCHES/40 PERCENT TO 70 PERCENT PASSING; 2 INCHES TO 4 INCHES ROCK/30 PERCENT TO 40 PERCENT PASSING; AND --2 INCHES ROCK/10 PERCENT TO 20 PERCENT PASSING. 15- ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM UNLESS APPROVED BY THE DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER OR STORMWATER UTILITY. AN ACCURATELY DIMENSIONED CERTIFIED AS -BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY OF RENTON UPON COMPLETION. 16. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMIT BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY OF RENTON DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTU:uCE OF THE SYSTEM PROVIDED DURING CONSTRUCTION. 17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTED EQUIPMENT, FAQ. AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFT, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACT. ANY WORK WITHIN THE TRAVELED RGHT-OF-WAY THAT MAY INTERRUPT NORM& TRAFFIC FLOW SHALL REQUIRE AN APPROVED TRAFFIC CONTROL PLAN BY THE TRAFFIC ENGINEERING DIVISM OF THE DEPARTMENT OF PUBLIC WORKS. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-0723, TRAFFIC CONTROL, SHALL APPLY. I& SPECIAL DRAINAGE MEASURES WILL BE REQUIRED IF THE PRDJECT LOCATION IS WITHIN THE AQUIFER PROTECTION AREA STOMA DRAINAGE PIPE SPECIFICATIONS ALL STORM DRAIN PIPE MAY BE CONSTRUCTED OF ONE OF THE FOLLOWING MATERIALS UNLESS OTHERWISE SPECIFIED IN THE PLANS. ALL PIPE JOINTS MUST BE GASKETED WATERTIGHT AND MUST BE OF THE SAME U47O V- AS THE PIPE. ALL PIPE SHALL HAVE A MINIMUM COVER AS SPECIFIED AND SHALL BE ADEQUATELY PROTECTED DURING CONSTRUCTION (REFER TO THE MANUFACTUREWS RECOMMENDATIONS FOR MINIMUM COVER FOR HEAVY EQUIPMENT LOADINGS). A DUCTILE IRON - 4 POC H THROUGH 14 INCH DIAMETER PIPE SHALL BE CLASS 52 AND 16-INCH THROUGH 24-INCH DIAMETER PIPE SHALL BE CLASS 50. ALL IN ACCORDANCE WITH USA STAND A-21.1 (AWWA C-51)- ALL JOINTS SHALL BE PUSH -ON, MECHANICAL, OR RANGED (6-INCH MINIMUM CDVM). B- CONCRETE - 4 INCH THROUGH 18 INCH DIAMETER PIPE SHALL BE NON -REINFORCED, BELL AND SPIGOT WITH RUBBER GASKET JOINTS, CONFORMING TO ASTM C-4 (CLASS II). 21 INCH THROUGH 36 INCH OWMET€R PPE SPALL BE REINFORCED. BELL AND SPIGOT WITH RUBBER GASKET JOINTS, CONFORMING TO ASTM C-76 (2 FOOT YINMUM COVER). C. PVC - 4 INCH THROUGH 18 RICH DYIYETER PIPE, WITH 24-INCH TO 36-INCH OF COVER SHALL BE IN ACCORDANCE WITH ASIM D3034 SDR 21. 4-INCH THROUGH 18-INCH DIAMETER PIPE, WITH ASTM D3034 SDR 35 SHALL HAVE 36-INCH MINIMUM COVER. ALL JOINTS SHALL BE PUSH -ON WITH RUBBER CASKETS. PVC SFM PPE REQUIRES A.C. COLLARS (I.E.. CATCH BASIN CONNECTION) OR KOR-N-SEAL CONCRETE BOOTS. D. HELMAI- CORRliG1TE PLANT AWYINU M PPE (COP) - 6 INCH THROUGH 18 INCH DIAMETER PIPE SHALL BE 16 GAUGE WITH 2 2/3 INCH X 1/2 MpE CORRIIfAl10NS 21 INCH THROUGH 36 INCH D114 ETER PIPE SHALL BE 14 GAUGE WITH 2 1/3 INCH X 1/2 INCH CORRUGATIONS. REFER TO DETAILS M THESE PLANS FOR ANY PIPES LARGER THAN 36 INCH DIAMETER. ALL ALUMINIZED PIPE SHALL HAVE ASF%4LT TREATMENT 1 COATING (20-FOOT MINIMUM COVER). E HELICAL CORRUGATED STEEL PPE (HCMP) - 6 INCH THROUGH 36 INCH SHALL BE 16 GAUGE WITH 2 2/? ^ 311 X 1/2 RICH CORRUGATIONS. ALL STEEL MATERIALS SHALL BE GALVANIZED AND ASPHALT HffATMENT 1 COATED. REFER TO DETAILS IN THESE PI I :"S FOR ANY PIPES LARGER THAN 36 INCHES IN DIAMETER (2A-FOOT M R4MUM COVER). F. CORRUGATED POLYLTHELE1E_ MEETING THE REQUIREMENTS OF AASHTO M-294, TYPE S. MINIMUM PIPE DIAMETER SHALL BE 8" MAXMINN PPE DVAOM SHALL BE 36" OR THE DIAMETER FOR WHICH THE SUPPLER NVS A JOINT CONFORYNG TO ASTM D 3212, WHICHEVER IS LESS. JOINTS SHALL BE CLASSIFIED AS '111ATERRGHT'. WATERMGHT JOINTS SIW1 BE MADE WITH A SLEEVE OR WITH A BELL SPIGOT AND SHILL CONFORM TO AT,'. D 3212 (10.8 PSI' USING ELASTOMERIC GASKETS CONFORMING TO ASTM IF477. CASIETED JOINTS SHALL BE WBT�CZ D AS RECOMMENDED BY THE PRODUCER DURING INSTALLATION. ^Sg0IGH1' JOINTS SHALL NOT BF PERMITTED. FITTINGS SHALL BE BLOW MOLDED. ROTATIONAL MOLDED. OR FACTORY WELDED, THERMOPLASTIC PIPE FITTINGS SHALL MEET THE REQUREMENTS SET FORTH IN AASHTO M 294. 7E6- it -0 -.ivr I ! i1 F S AT OII 4tX OF SUNSET &V9 T NE A.H. WDM+N LT NF 7 I 'D+OO.OD II 11 li II as aver _ -�I - - - - RIM=393.55 IE-390.17(8" PVC ) fz o I MATCM'E 1E=389.57(8' CONC IV) ..,1 EXIS`L'dG CB-S I H!M=393.55 390,11(6" CONC F) i, tU 11--- EXiSTING MON. WELL-._-._ I T� -- I`` I I XI EXISTING- POWER. VALA T� fill s '( `I-?6 GAIT J-BOX 4 FIRE HYDRANT AN0 WATER VA.-VE I , =XIST2NG C8 D RIM IE 389 C9(,8" CvNC IJJ �E-384.21 \i, !, I I I i ExSTiNG C8 E R:M 39506 339.16(18" CCNC ) : ! \\ !I `✓ RM 395zi _86.4.,ii9CONC tJ \ i . 13 oa IE 3865:(8' CONC S) :E 386.91 (8" PVC W) FOUND BRASS 'SAIL -\ .N W/P uc.H . A 4" .,'vNC MOH. IN CASE (4 EX!ST'NG SSMH C R'M-59:i.43 E 3 6.82(8' CONC ) 386.964'48' SE \ i ,E PVC !E-387.13`8' 'JC SW) 8" CONC N IE=386.53 �� \ � I I II EXISTING -� TELEPHONE MANHOLE II -� EX!ST!NG LIGHT J"-BOX -- AND LUMINAfRE It EXISTING WATER VALVE 1 it EXISTING SDMH-8---.,-_ RIM=395.54 \�\ I I IE=It'.89((((((18" COMC N)) IE=389.99(18" CCNC' S) \ J ' IE=390.44 15" CMP "W) xV: IE:=390.28112" CMP SE) ,-I.;� . , \1y I1EXISTING I ;. CB-F RIM-395.4 .E=390.29(12" CMP 'L) Iazoo �I{ E=389.86h1;" CMP NW) IE=393.86ta- CMP) IE=390.11(12" CMP S) I- EX151ING SSMF-A RIM=395.17 IE=385.6i(8"" CON-, N� IE-385.73 8CONC S, ' SDMH-A XISTI RIMz 394.93 1.. 83.00(18' CONC �) - IE=389.00 18" CONCN) t- EXISTING CB-B r RIAi-33 21 / IC 390.46 24 CIdP NW) IE 343.D18 MP) !E 389 70,8 - CMP S) CB 5 TYPE 1 1 RIM=393.98 57 LF 12' SD ® 1..0% IE=389.82(12") JJf EXIsONG I""3gQ PAVEMENT I ! B T38'55" E I 5 LF 12' SO 0 1.0% CHAIN LINK PENCE WITH TAP- 1E=388.8110E) COILC WALL CHAIN I. K FENCE J MEASURED WITH TAP EASEMENT (PER SHORT SIDEWALK DRIVEWAY OR ALLEY EXPANSION JOINTS SEE NOTE 2 su• A A 318"JOINTS SIDN 2$,klt'IMt SEE NOTE 2 44 " SEE NOTE 1 Ali SIDEWALK N„ s^ MsmMlrlk , Ie- tM�mwE�ac1H. ,n CURB AND GUTTER \ ALTERNATE 1 pR ,,, `-SEE ➢ETAIL "A" SHOWN HOWEVER, OTHER CURBS MAY WHEN THERE IS A PLANTING STRIP ,y EXPANSION JOINT BE USED (SEE SECTION A -A STANDARD PLANS) 3/8" EXPANSION JOINTS SEE NOTE 2 DRIVEWAY OR ALLEY SCORE LINE 3/8" EXPANSION DETAIL A JOINTS SEE 1 gppRGACH WITH SEE NOTE 2 SIDEWALK MGNGLITHIC CURB SEE NOTE 5 as ALTERNATE 2 M„ � WHEN SIDEWALK IS NEXT TO CURB NDTE- CEMENT CONCRETE DRIVEWAY 1. DUMMY JOINTS SHALL BE PLACED NOT TO EXCEED 15'C/CNOR LESS THAN 10' C:C. THEY SHALL OR ALLEY APPROACH NOT BE LESS THAN 3/16" IN THICKNESS AND SHALL EXTEND 2-1/4" DEEP. 2 1/2" THRU JOINTS SMALL BE PLACED AT BACK, SIDES. AND FRONT (BEHIND CURB) OF APPROACH. 3 CEMENT CONCRETE SHALL BE CLASS 3D00 AIR ENTRAINEDp 4 ALL JOINTS SHALL BE CLEANED AND EDGED. 5 APPROACH SHALL NOT BE POURED INTEGRAL WITH CURB AND GUTTER, BUT MAY BE POURED -INNTEGRAL WITH STANDARD CURB (SEE DETAIL "A"). 6. SUBGRA➢E COMPACTION SHALL BE 95% MODIFIED PROCTOR: I'9L°�Iy�s/AI RflnSioN BY R DWG. NAME: FRONN SP PAGE:FOO6 CAST IRON FRAME & CONC. DRIVE SLAB .S INSTALL86 LF.. TRENCH DRAIN PER DETAIL THIS SHEET. _ C / o n � a• • • a aeis➢ .g ..I FLa184 so. uNE C3w D - // 6" PVC (SDR-35) / TO STORM DRAIN v L � 93 LF 6' DIA CMP a ° S v_ DETENTION PIPE SEE SHEET C5ACE SLOPE FLOOR OF . - TRENCH DRAIN ® 0.5% .// Q TO 6" OUTLET - CAST IN P CONC, BASE (3000) P51 MIN.) 2, TYPE 2-54" 1° " v / SEE SHT C5 FOR (4) #4 #4 ® 12" O.C. vk C ° 93M .DETAILS 13 LF 6" DI ® 0.50% 20 LF 12' DI 11 ,.o% FORMED IN PLACE 41 . ' CB 3, TYPE 1 TRENCH DRAIN DETAIL :e4 ! RIM=394.80 IE=391.20(12-) - NOT TO SCALE EXISTING WATER VALVE 28 12" DI 0 1.07 CB 04, TYPE 11,1 �IM=3� 94.30 1 391.48 1 ,\- EXISTING \FXISTING WOOD LAUREL FENCE - FOUND REBAR HEDGE 0.17 S 0.51' E (DISTURBED) EXISTING RAILROAD TIE PLANTER C-\/), N9-276-E`63 TL Iq GOGo 0 z U m< 0, to Ir O U F- Z Z W A Q Q `VR 7 CO IL m a: 0 y z U r 0 a!O MW W n